Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

Similar documents
Specifications. C13 Generator Set Electric Power

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

Specifications. 3406C Generator Set Electric Power

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

3412C Generator Set Electric Power. Specifications. Benefits and Features

Voltage 220 to or 1800 RPM

220 to volts. Electronic unit injection

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Continuous, Prime, Standby, Mission Critical

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Voltage 220 to or 1800 RPM. Engine Specifications C32 TA, V-12, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in)

400 to 11,000 Volts. Standby, Prime, Continuous

STANDBY 350 ekw kva 60 Hz 1800 rpm 480 Volts

like mission critical Backed by the worldwide l provide the reliabi Mission Critical LEHE1075

C13. STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Generator Set Specifications 100 ekw (125 kva)

including r installations. Backed by the worldwide l provide the reliabi Prime LEHE1073

STANDBY 400 ekw 500 kva

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Generator Set Specifications 60 ekw (75 kva)

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

Aftercooler (Separate Circuit) N/A N/A

PRIME 225 ekw 281 kva

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

Hydraulic electronic unit injection

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

Enclosures. Options Caterpillar yellow or white paint Integral dual wall fuel tank base for total fluid containment (fuel, oil and coolant)

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENERATOR SET FEATURES

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

Generator Set Specifications 480 ekw 600 KVA

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Bore mm 4.0 in Displacement 5.7 L 350 in³ Stroke 88.4 mm 3.48 in Compression Ratio 9.4:1

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Generator Set Specifications 320 ekw (400 kva)

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

DIESEL FEATURES GENERATOR SET

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

STANDBY 350 ekw 438 kva 60 Hz 1800 rpm 480 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

STANDBY 440 ekw 550 kva 50 Hz 1500 rpm 400 Volts

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

3516B Generator Set Electric Power

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 480 ekw 600 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

Transcription:

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications Generator Set Specifications Minimum Rating Maximum Rating Voltage Frequency Speed 320 ekw 400 ekw 380 to 415 Volts 60 Hz 1800 RPM Generator Set Configurations Emissions/Fuel Strategy Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards Engine Specifications Engine Model C13 ATAAC, I-6, 4-Stroke Water-Cooled Diesel Displacement 12.5 L 762.8 in³ Bore 130 mm 5.12 in Stroke 157 mm 6.18 in Compression Ratio 16.3:1 Aspiration Air to Air Aftercooled Governor Type Adem A4 Fuel System MEUI Benefits and Features Cat Diesel Engine Generator Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight SS-8254230-1000029524-001 SS Page 1 of 7 Page: M-1 of M-4

Matched to the performance and output characteristics of Cat engines Industry leading mechanical and electrical design Industry leading motor starting capabilities High Efficiency Cat EMCP Control Panel Design Criteria The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules. The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response. Single-Source Supplier Fully prototype tested with certified torsional vibration analysis available World Wide Product Support Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S O S program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products Standard Equipment Packaged Generator Set Disposable Air filter Service indicator Radiator package mounted Coolant level sight gauge Low coolant level sensor Coolant drain line with valve Fan and belt guards Cat Extended Life Coolant Dry exhaust manifold Stainless steel flex fittings Exhaust flange outlet Integral narrow single wall fuel tank base Primary fuel filter with integral water separator Secondary fuel filters Fuel priming pump Engine fuel transfer pump Fuel cooler integral with cooling system Flexible fuel lines Class H insulation SS-8254230-1000029524-001 SS Page 2 of 7 Page: M-2 of M-4

Self excited (SE) Class H temperature rise IP23 protection R450 voltage regulator with single phase sensing and load adjustment module Power Center houses EMCP controller and power/control terminations (rear mounted) Circuit breaker, IEC compliant, 3-4 pole (100% Rated) Segregated low voltage wiring termination panel Bottom cable entry EMCP 4.1 (Rear-mounted in Power Center) Integral Narrow 8hr tank base Linear vibration isolation 24 volt starting motor 24 volt, 45 amp charging alternator Batteries with rack and cables Paint - Caterpillar Yellow except rails and radiators gloss black (Powder Coated) Flywheel housing - SAE No.1/2 Optional Equipment Packaged Generator Set Options: Note some options are not available in all regions Canister type Air Filter: Single element Dual element Radiator duct flange Stone Guard Low coolant temperature alarm Industrial, Residential, Critical Mufflers Manifold and turbocharger guards Elbows and flange kits Fuel level switch Manual fuel transfer pump Oversize generators Permanent magnet excitation (PMG) Internal excited (IE) Cat digital voltage regulator (Cat DVR) with kvar/pf Anti-condensation space heaters Coastal Insulation Protection (CIP) Reactive droop Three phase sensing SS-8254230-1000029524-001 SS Page 3 of 7 Page: M-3 of M-4

C.B. Shunt trips C.B. Auxiliary contacts EMCP 4.2 Oil temperature sensor Manual sump pump Narrow skid base Integral Dual Wall 8hr tank base (Available only with enclosed units) Jacket water heater Battery disconnect switch Battery charger - 5 amp EU Certificate of Conformance Sound attenuated protective enclosure with integral lifting frame High Ambient enclosure with integral lifting frame The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, ADEM, EUI, S O S, "Caterpillar Yellow" and the "Power Edge" trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. SS-8254230-1000029524-001 SS Page 4 of 7 Page: M-4 of M-4

ELECTRIC POWER - Technical Spec Sheet STANDARD 400 ekw/ 500 kva/ 60 Hz/ 1800 rpm/ 480 V/ 0.8 Power Factor Rating Type: STANDBY Fuel Strategy: LOW FUEL CONSUMPTION 400 ekw/ 500 kva 60 Hz/ 1800 rpm/ 480 V Image shown may not reflect actual configuration Metric English Package Performance Genset Power Rating with Fan @ 0.8 Power Factor 400 ekw Genset Power Rating 500 kva Aftercooler (Separate Circuit) N/A N/A Fuel Consumption 100% Load with Fan 107.7 L/hr 28.4 gal/hr 75% Load with Fan 80.9 L/hr 21.4 gal/hr 50% Load with Fan 56.5 L/hr 14.9 gal/hr 25% Load with Fan 33.7 L/hr 8.9 gal/hr Cooling System¹ Engine Coolant Capacity 14.2 L 3.8 gal Inlet Air Combustion Air Inlet Flow Rate 27.2 m³/min 960.0 cfm Max. Allowable Combustion Air Inlet Temp 50 C 122 F Exhaust System Exhaust Stack Gas Temperature 577.4 C 1071.2 F Exhaust Gas Flow Rate 82.5 m³/min 2911.4 cfm Exhaust System Backpressure (Maximum Allowable) 10.0 kpa 40.0 in. water SS-8254230-1000029524-001 SS Page 5 of 7 TSS-EM0423-04-GS-EPG-8254230.pdf 2016 Caterpillar All Rights Reserved Page 1 of 3

ELECTRIC POWER - Technical Spec Sheet STANDARD 400 ekw/ 500 kva/ 60 Hz/ 1800 rpm/ 480 V/ 0.8 Power Factor Rating Type: STANDBY Fuel Strategy: LOW FUEL CONSUMPTION Heat Rejection Heat Rejection to Jacket Water 158 kw 8981 Btu/min Heat Rejection to Exhaust (Total) 386 kw 21950 Btu/min Heat Rejection to Aftercooler 70 kw 3997 Btu/min Heat Rejection to Atmosphere from Engine 72 kw 4122 Btu/min Heat Rejection to Atmosphere from Generator 29 kw 1661 Btu/min Alternator² Motor Starting Capability @ 30% Voltage Dip Current Frame Size Excitation Temperature Rise 880 skva 601 amps LC6114B SE 150 C Emissions (Nominal)³ NOx 2396.2 mg/nm³ 4.9 g/hp-hr CO 630.8 mg/nm³ 1.3 g/hp-hr HC 5.7 mg/nm³ 0.0 g/hp-hr PM N/A N/A DEFINITIONS AND CONDITIONS 1. For ambient and altitude capabilities consult your Cat dealer. Air flow restriction (system) is added to existing restriction from factory. 2. UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics. Generator temperature rise is based on a 40 C ambient per NEMA MG1-32. 3. Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D & E and ISO8178-1 for measuring HC, CO, PM, NOx. Data shown is based on steady state operating conditions of 77 F, 28.42 in HG and number 2 diesel fuel with 35 API and LHV of 18,390 btu/lb. The nominal emissions data shown is subject to instrumentation, measurement, facility and engine to engine variations. Emissions data is based on 100% load and thus cannot be used to compare to EPA regulations which use values based on a weighted cycle. SS-8254230-1000029524-001 SS Page 6 of 7 TSS-EM0423-04-GS-EPG-8254230.pdf 2016 Caterpillar All Rights Reserved Page 2 of 3

ELECTRIC POWER - Technical Spec Sheet STANDARD 400 ekw/ 500 kva/ 60 Hz/ 1800 rpm/ 480 V/ 0.8 Power Factor Rating Type: STANDBY Fuel Strategy: LOW FUEL CONSUMPTION Applicable Codes and Standards: AS1359, CSA C22.2 No100-04, UL142,UL489, UL869, UL2200, NFPA37, NFPA70, NFPA99, NFPA110, IBC, IEC60034-1, ISO3046, ISO8528, NEMA MG1-22,NEMA MG1-33, 2006/95/EC, 2006/42/EC, 2004/108/EC. Note: Codes may not be available in all model configurations. Please consult your local Cat Dealer representative for availability. STANDBY:Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby power rating. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions Fuel Rates are based on fuel oil of 35º API [16º C (60º F)] gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C (85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional ratings may be available for specific customer requirements, contact your Cat representative for details. For information regarding Low Sulfur fuel and Biodiesel capability, please consult your Cat dealer. www.cat-electricpower.com Performance No.: EM0423-04 Feature Code: C13DE12 Generator Arrangement: 3969606 Date: 12/26/2016 Source Country: U.K. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, ADEM, EUI, S O S, "Caterpillar Yellow" and the "Power Edge" trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. SS-8254230-1000029524-001 SS Page 7 of 7 TSS-EM0423-04-GS-EPG-8254230.pdf 2016 Caterpillar All Rights Reserved Page 3 of 3