JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

Similar documents
Ex eb IIC Gb Ex ia IIC Ga Ex Tb IIIC Db DRILLING AND ASSEMBLY OF JBEP JUNCTION BOXES AND ENCLOSURES GUIDE

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

Unicode 2 Series Pre-Drilled Control Stations Increased Safety Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

Terminal Boxes in Stainless Steel SLS**.T

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

Junction Boxes & Enclosures JBES Series: Pre-drilled 316L Stainless Steel Junction Boxes Increased Safety

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety

PRE Series 63 Amp Plugs and Sockets Increased Safety

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

ATX DPD Series Distribution Panelboards Flameproof

JBDA and JBDF ECDA and ECDF Series Customized Enclosures Flameproof

PRE Series 125 Amp Plugs and Sockets Increased Safety

Assembly. Trunk IN + - S U, I U, I. Spur 1

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

Terminal Boxes TNCN. Explosion protection Marking

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Glass Reinforced Polyester Enclosures

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

Panelboards & Motor Starters

IECEx Certificate of Conformity

HTSB system System overview

Linear fittings EVDL LED fitting - zones 21, & 22

Terminal Boxes Series 8125

Ex e, ia Junction boxes TNCN. Features

FL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

Plugs & Sockets PRE Series: 16 A Plugs and Sockets Increased Safety

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Operating Instructions

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

Capri ADE 6F - for Armoured Cable

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear fittings EVNL LED fitting - zones 2, & 22

also in ATEX Data Sheet Enclosures Klippon POK Glass Fibre reinforced Polyester Enclosures

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Cubo X Stainless Steel Enclosures

OPERATING INSTRUCTIONS

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

Leading the way in hazardous areas Features EATON

New products Ex Equipment 2015

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

CCAI, CCAIF, CCAIF..H

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Junction boxes for control, monitoring and control panel Ex tb

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Junction box for EKL light

CTB. Ex e. Captive screws B.67. Detail of TIG welding of walls. Earth stud with cable anti-rotation bracket

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Kopex-Ex cable glands offer superior protection in hazardous environments

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

ABG Cable Glands Installation Procedure

Hazardous Area Electrical Equipment. TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22. Index

Linear fluorescent luminaire LED V-CG-S

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

Load disconnect switch Series 8146/5-V11

Ex m Solenoid Operator Type 0519

Floodlight LED Series 6125

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

M-0. M-0... series control, monitoring and signalling devices. Ex e

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

ANNEX to IECEx BAS X Issue No. 0 Date: 15/05/2012

EExe and EExi terminal boxes in polyester and aluminium for Ex areas

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology

The safety you rely on.

DECONTACTOR. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

Spring loaded resistance thermometer

Emergency Luminaire with LED Series EXLUX 6409/1

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Linear Luminaire with LED Series EXLUX 6402/2

CYCLOPS X Purge Controller SM Version

PXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS 10 A TECHNICAL FEATURES

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Emergency Light Fitting for Fluorescent Lamps Series 6009

I Ex-Safety switches I

Terminal Boxes Series 8252/1

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

Products for. Section

I Ex-safety switches I

Certificate of Compliance

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Transcription:

Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes Applications Instrumentation junction boxes are used to run process or remote information to control room. For use in intrinsic safety or non intrinsic safety systems. Designed for Zones 1 or 2 areas, where flammable gases or vapors are present either continuously, often or accidentally such as: Petroleum Chemical Refineries Other industrial process facilities Ideal for indoor/outdoor use with wet or corrosive atmospheres. Designed for use in Zones 21 or 22 areas where flammables dusts (conductive and non conductive) are present either continuously, often or accidentally such as: Food processing Dairy Brewing Other industrial process facilities Designed for Zone 0 and Zone 20 Intrinsically Safe applications when used with rated terminals. Features Available in a wide range of sizes: For armored, unarmored or armored lead sheathed cable For use with a variety of connection and earth terminals Optional external hinged enclosures: Reversible door opening 120. Door with double bar lock. Key locking facility. Terminal blocks on DIN rail. Standard materials Enclosures: Static resistant carbon filled fiberglass reinforced polyester (FRP) Hardware: stainless steel Gasket for other sizes: EPDM (ethylene propylene diene monomer rubber) Options External hinges are available on the following sizes: 500 x 320 x 150 500 x 320 x 230 750 x 320 x 150 750 x 320 x 230 Removable glands plates Nameplates Mounting pan Inside pocket for document Consult factory for custom drilling, assembly requirements and other ambient temperatures. Certifications and Compliances Type : JBEP Ambient Temperatures : -55 C Ta +60 C Gas, Zones 1 and 2: Conforming to ATEX 94/9/EC: II 2G Conforming to IECEx : EPL Gb Protection: Ex eb IIC, Ex eb ia IIC, Ex eb ib IIC, Ex ib IIC T Rating: T6 for Ta +40 C and T5 for Ta +60 C Dusts, Zones 21 and 22: Conforming to ATEX: II 2D Glands are available as an Option. Conforming to IECEx: EPL Db Protection: Ex tb IIIC Surface Temperature : T60 C for Ta +40 C, T90 C for Ta +60 C Gas, Zone 0: Conforming to ATEX 94/9/EC: II 1G Conforming to IECEx : EPL Ga Protection: Ex ia IIC T Rating: T6 for Ta +40 C and T5 for Ta +60 C Dusts, Zones 20: Conforming to ATEX: II 1D Conforming to IECEx: EPL Da Protection: Ex ta IIIC Surface Temperature : T60 C for Ta +40 C, T90 C for Ta +60 C ATEX Certificate : LCIE 12 ATEX 3037X EC Declaration of Conformity : 50291 IECEx Certificate : IECEx LCIE 13.0003X Ingress Protection (solid and liquid) : IP66 Impact Resistance: IK10 Ex Standards: EN/IEC 60079-0; 60079-7; 60079-11; 60079-31 Other Standards: EN/IEC 60529 (IP); 62262 (IK) Type : Bve (plastic close up plug) Ambient Temperatures : -40 C to +55 C Type : 757 (nickel plated close up plug) Ambient Temperatures : -60 C to +100 C Type : EEXe (plastic cable gland) Ambient Temperatures : -20 C to +55 C Type : E1FX, E2FX, E1FW, E2FW, T3, A2F (metal cable gland) Ambient Temperatures : -60 C to +130 C Type : PX, PX2K (metal cable gland) Ambient Temperatures : -60 C to +100 C Type : DBE (drain/breather) Ambient Temperatures : -50 C to +85 C Type : WDU, WFF (terminal) Ambient Temperatures : -50 C to +120 C Type : SAK, AKZ (terminal) Ambient Temperatures : -50 C to +100 C Related Products For a complete offering of cable glands for use with armored and unarmored cable, see Fittings: Glands. The ambient temperature for complete assembly is equal to the lowest ambient temperature of the components used. 508

Illustrated Features Sample of JBEP171709NI01 Description The Numbering Guide is a reference tool to explain the make-up of the catalog number. It is not to be used to create a custom product for ordering. Numbering Guide JBE P 17 17 09 A I 01 D Series: JBE - Junction Box Certified 1 Body Of Polyester Box 170 x 170 x 90 2 Cover Of Polyester Box 170 x 170 x 91 3 Din Rail 4 Copper Bar 10 x 3 5 - WDU 2.5 6 - WPE 2.5 7 Plate - WAP 2.5/10 8 End Bracket 9 Clamp 2.5 mm 2 - Capacity 10 Stainless Steel Rivet 2.5 x 5 11 Serrated Washer 5 12 Label Gravoply - Yellow 13 Nylons Spacer Lg. 10 Mm 14 Label 54 x 68 15 Terminal Marker 16 Screw M6 x 20 x 10 17 Screw M5 x 20 18 Gasket For Polyester Box 170 x 170 x 91 19 G/Y 2.5 mm 2 Material: P - Polyester Dimensions Height mm (in): 17-170 (6.69) 20-200 (7.87) 21-215 (8.47) 25-250 (9.84) 32-320 (12.60) 50-500 (19.69) 75-750 (29.53) Dimensions Width mm (in): 17-170 (6.69) 21-215 (8.47) 25-250 (9.84) 32-320 (12.60) 50-500 (19.69) 75-750 (29.53) Dimensions Depth mm (in): 09-91 (3.58) 15-150 (5.91) 23-230 (9.06) Type: A - Armored N - Non-Armored L - Armored Lead Sheathed Options: I - Instrumentation Suffix: 01 to 99 Assigned at Factory Options: D - Drain Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes 509

Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes Ex eb IIC Factory Drilled JBEP Polyester Junction Boxes Equipped with Terminals for with Unarmored s Fitted with: Horizontal beige terminal block. Copper bar with cable clamps or continuity shields. Yellow laminated plastic label with black lettering. M16 to M32 threaded entries. M40 to M50 clearance holes. glands and plugs ordered separately. U1000 Earth Terminal Copper Bar Clamp RO2V 10 x 3 mm Qty. Unarmored s 07G1.5 7 1 1 5 M20 3 JBEP171709NI01 12G1.5 12 1 1 8 M25 6 JBEP202115NI02 19G1.5 19 1 1 11 M25 9 JBEP253215NI03 24G1.5 24 1 1 14 M32 12 JBEP253215NI04 27G1.5 27 1 1 15 M32 13 JBEP253215NI05 37G1.5 37 1 1 20 M32 18 JBEP253215NI06 07G2.5 7 1 1 5 M20 3 JBEP171709NI07 12G2.5 12 1 1 8 M25 6 JBEP202115NI08 19G2.5 19 1 1 11 M32 9 JBEP253215NI09 24G2.5 24 1 1 14 M32 12 JBEP253215NI10 27G2.5 27 1 1 15 M32 13 JBEP253215NI11 37G2.5 37 1 1 20 M40 18 JBEP253215NI12 M16 Qty. EGSF 07IP05 14 7 M20 7 JBEP202115NI21 07IT05 21 7 M20 7 JBEP202115NI22 12IP05 24 12 M25 12 JBEP253215NI23 12IT05 36 12 M25 12 JBEP253215NI24 19IP05 38 19 M32 19 JBEP253215NI25 27IP05 54 27 M32 27 JBEP325015NI26 07IP09 14 7 M25 7 JBEP202115NI27 07IT09 21 7 M25 7 JBEP202115NI28 12IP09 24 12 M32 12 JBEP253215NI29 12IT09 36 12 M32 12 JBEP253215NI30 19IP09 38 19 M32 19 JBEP253215NI31 27IP09 54 27 M40 27 JBEP325015NI32 M16 Qty. EISF 07IP05 15 8 M25 7 JBEP202115NI41 07IT05 22 8 M32 7 JBEP202115NI42 12IP05 25 13 M32 12 JBEP253215NI43 12IT05 37 13 M32 12 JBEP253215NI44 19IP05 39 20 M40 19 JBEP253215NI45 27IP05 55 28 M40 27 JBEP325015NI46 07IP09 15 8 M32 7 JBEP202115NI47 07IT09 22 8 M32 7 JBEP202115NI48 12IP09 25 13 M40 12 JBEP253215NI49 12IT09 37 13 M40 12 JBEP253215NI50 19IP09 39 20 M50 19 JBEP253215NI51 27IP09 55 28 M50 27 JBEP325015NI52 For JBEP terminal junction box with a drain, add suffix D to the end of the catalog number; example: JBEP171709NI01D. 510

Ex eb IIC Factory Drilled JBEP Polyester Junction Boxes Equipped with Terminals for with Armored s Fitted with: Horizontal beige terminal block. Copper bar with cable clamps or continuity shields. Yellow laminated plastic label with black lettering. Earth continuity brass plate. M8 external earth crossing terminal. M20 to M32 threaded entries. M40 to M50 clearance holes. glands and plugs ordered separately. Armored s U1000 RVFV Earth Terminal Copper Bar 10 x 3 mm Qty. Clamp 07G1.5 7 1 1 5 M20 3 JBEP171709AI01 12G1.5 12 1 1 8 M20 6 JBEP202115AI02 19G1.5 19 1 1 11 M25 9 JBEP253215AI03 24G1.5 24 1 1 14 M25 12 JBEP253215AI04 27G1.5 27 1 1 15 M25 13 JBEP253215AI05 37G1.5 37 1 1 20 M32 18 JBEP253215AI06 07G2.5 7 1 1 5 M20 3 JBEP171709AI07 12G2.5 12 1 1 8 M25 6 JBEP202115AI08 19G2.5 19 1 1 11 M25 9 JBEP253215AI09 24G2.5 24 1 1 14 M32 12 JBEP253215AI10 27G2.5 27 1 1 15 M32 13 JBEP253215AI11 37G2.5 37 1 1 20 M32 18 JBEP253215AI12 EGFA 07IP05 14 7 M20 7 JBEP202115AI21 07IT05 21 7 M20 7 JBEP202115AI22 12IP05 24 12 M25 12 JBEP253215AI23 12IT05 36 12 M25 12 JBEP253215AI24 19IP05 38 19 M25 19 JBEP253215AI25 27IP05 54 27 M32 27 JBEP325015AI26 07IP09 14 7 M25 7 JBEP202115AI27 07IT09 21 7 M25 7 JBEP202115AI28 12IP09 24 12 M25 12 JBEP253215AI29 12IT09 36 12 M32 12 JBEP253215AI30 19IP09 38 19 M32 19 JBEP253215AI31 27IP09 54 27 M40 27 JBEP325015AI32 EIFA 07IP05 15 8 M25 7 JBEP202115AI41 07IT05 22 8 M25 7 JBEP202115AI42 12IP05 25 13 M32 12 JBEP253215AI43 12IT05 37 13 M32 12 JBEP253215AI44 19IP05 39 20 M32 19 JBEP253215AI45 27IP05 55 28 M40 27 JBEP325015AI46 07IP09 15 8 M32 7 JBEP202115AI47 07IT09 22 8 M32 7 JBEP202115AI48 12IP09 25 13 M40 12 JBEP253215AI49 12IT09 37 13 M40 12 JBEP253215AI50 19IP09 39 20 M40 19 JBEP253215AI51 27IP09 55 28 M50 27 JBEP325015AI52 Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes For JBEP terminal junction box with a drain, add suffix D to the end of the catalog number; example: JBEP171709NI01D. 511

Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes Ex eb IIC Factory Drilled JBEP Polyester Junction Boxes Equipped with Terminals for with Lead Sheath Armored s Fitted with: Horizontal beige terminal block. Copper bar with cable clamps or continuity shields. Yellow laminated plastic label with black lettering. Earth continuity brass plate. M8 external earth Armored s crossing terminal. M20 to M32 threaded entries. M40 to M50 clearance holes. glands and With lead sheath plugs ordered separately. U1000 RGPFV Earth Terminal Copper Bar 10 x 3 mm Qty. Clamp 07G1.5 7 1 1 5 M20 3 JBEP171709LI01 12G1.5 12 1 1 8 M25 6 JBEP202115LI02 19G1.5 19 1 1 11 M25 9 JBEP253215LI03 24G1.5 24 1 1 14 M32 12 JBEP253215LI04 27G1.5 27 1 1 15 M32 13 JBEP253215LI05 37G1.5 37 1 1 20 M32 18 JBEP253215LI06 07G2.5 7 1 1 5 M20 3 JBEP171709LI07 12G2.5 12 1 1 8 M25 6 JBEP202115LI08 19G2.5 19 1 1 11 M32 9 JBEP253215LI09 24G2.5 24 1 1 14 M32 12 JBEP253215LI10 27G2.5 27 1 1 15 M32 13 JBEP253215LI11 37G2.5 37 1 1 20 M40 18 JBEP253215LI12 EGPF 07IP05 14 7 M20 7 JBEP202115LI21 07IT05 21 7 M20 7 JBEP202115LI22 12IP05 24 12 M25 12 JBEP253215LI23 12IT05 36 12 M25 12 JBEP253215LI24 19IP05 38 19 M25 19 JBEP253215LI25 27IP05 54 27 M32 27 JBEP325015LI26 07IP09 14 7 M25 7 JBEP202115LI27 07IT09 21 7 M25 7 JBEP202115LI28 12IP09 24 12 M32 12 JBEP253215LI29 12IT09 36 12 M32 12 JBEP253215LI30 19IP09 38 19 M40 19 JBEP253215LI31 27IP09 54 27 M40 27 JBEP325015LI32 EIPF 07IP05 15 8 M25 7 JBEP202115LI41 07IT05 22 8 M32 7 JBEP202115LI42 12IP05 25 13 M32 12 JBEP253215LI43 12IT05 37 13 M32 12 JBEP253215LI44 19IP05 39 20 M40 19 JBEP253215LI45 27IP05 55 28 M50 27 JBEP325015LI46 07IP09 15 8 M32 7 JBEP202115LI47 07IT09 22 8 M32 7 JBEP202115LI48 12IP09 25 13 M40 12 JBEP253215LI49 12IT09 37 13 M40 12 JBEP253215LI50 19IP09 39 20 M50 19 JBEP253215LI51 27IP09 55 28 M50 27 JBEP325015LI52 For JBEP terminal junction box with a drain, add suffix D to the end of the catalog number; example: JBEP171709NI01D. 512

Dimensions in Millimeters (Inches) B J M A G D Y Enclosure Number JBEP1717090 JBEP2021150 JBEP2532150 JBEP3250150 H E F C External Dimension Internal Dimensions Cover Body Wall Fixing A B C D E F G H J Thickness X Y M 170 (6.693) 200 (7.874) 250 (9.843) 320 (12.598) 170 (6.693) 215 (8.465) 320 (12.598) 500 (19.685) 91 (3.583) 145 (5.709) 150 (5.906) 150 (5.906) 158.5 (6.240) 185.8 (7.315) 241 (9.488) 311 (12.244) 158.5 (6.240) 200.8 (7.906) 311 (12.244) 491 (19.331) 72 (2.835) 122.5 (4.823) 133.5 (5.256) 133.5 (5.256) 112.5 (4.429) 114.8 (4.519) 171 (6.732) 267 (10.512) 137 (5.394) 159 (6.260) 267 (10.512) 421 (16.575) 15 (0.591) 20 (0.787) 15 (0.591) 15 (0.591) X 4.5 (0.177) 6.1 (0.240) 5 (0.197) 5 (0.197) 153 (6.024) 189 (7.441) 200 (7.874) 298 (11.732) 131 (5.157) 146 (5.748) 298 (11.732) 447 (17.598) M5 M6 M6 M6 Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes Wall fixing screw diameter 5 mm (0.20 ). Wall fixing screw hole 6 mm (0.24 ). Screw to be used for mounting box. 513