CONSOLE MANAGEMENT CONTROLLER

Similar documents
HP Adjustable Depth Fixed Rail Kit Installation

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

HP Modular Cooling System 200/100 Options Installation Guide

Lighting Control Unit Installation Instructions

HP Server Mount Kit AB292A for 19 in. 2-Post Rack Installation Instructions Manufacturing Part Number: AB April 2004

Fiber Splice Panel Rack Mount User Manual

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Universal 8-Bay Charger. for AA/AAA/C/D/9 NiMH & NiCd Rechargeable Batteries. Owner's Manual

4-Hour. Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual

Dispenser Pan Sensors & Containment Sump Sensors

Installation & Programming Manual. Quick Reference

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

TOYOTA TACOMA TVIP V3 (RS3200) Section I - Installation Preparation

Parts and Accessories. Installation Instructions.

Installing the Switch Chassis

SAFETY-- SECURITY-- SIMPLICITY! TM

QuickSpecs. HP 480/277 Volt Solutions. Overview

TOYOTA TUNDRA TVIP V5

When the ACB is CLOSED and in the connected position the draw-out handle cannot be inserted.

Declaration of Conformity

DODGE DAKOTA 3 KIT INSTALLATION INSTRUCTIONS KIT# 60043

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

Installing Power Components

Foreword

Dolphin TM 6110 Mobile Computer. Quick Start Guide

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual

Electrically Held to Mechanically Latched Contactor

Installation Instruction

FuelsManager and Radar Tank Gauging for Overfill Prevention

G72x Series Direct Spark Ignition Controls

DIAGNOSIS AND TESTING

DIAGNOSIS AND TESTING

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

PSU EN54-4 Power Supplies

Dispenser Pan Sensors & Containment Sump Sensors

QuickSpecs. HP Basic Power Distribution Units. Overview

Fisher 2052 Diaphragm Rotary Actuator

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Powerware Vdc Extended Battery Cabinet User s Guide.

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

USER INSTRUCTIONS FOR SLIDING DOORS

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

LED ROLLER LIGHTING. LED Components... 6

Touchstone TB130 DC Output UPS

Operating Instructions

Installation Guide. Thermal Conductivity Detector on a 6850 GC Accessory G2623A

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Micro-Air Corporation Route 526 Allentown, NJ 08501

IMPORTANT SAFEGUARDS

Elmdene International Ltd

Electric Vehicle Charging Station

MOTION-ACTIVATED WALL LANTERN

Liebert GXT MT+ User Manual VA Installer/User Guide

1000 Park Drive Lawrence, PA Fax

Commander 15i Container and Pallet Loader. Property of American Airlines

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview

INSTALLATION MANUAL. Fendt VarioGuide Ready COM 3 Supported Models PN REV A

TOYOTA TACOMA TVIP V5

Installation Guide. Heater Interface Cable for Mass Sensitive Detector Accessory G1590A

Rack Installation Guide (Steelhead Series 3000, 5000, and 6000, and Interceptor Systems)

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

TOYOTA RAV TVIP V5

2016 Wand Handle Repair Instructions & Parts List

SECTION B Supplemental Restraint System

Informer Compact Series

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

AC 2307 Seven-Slot T1 Mini Repeater Apparatus Case

Installation and Operation

TOYOTA TUNDRA 2 & 4WD 3 BODY LIFT KIT INSTALLATION INSTRUCTIONS 2006 KIT# 5623

Rack Mount Power Supplies

STRX-9 100% TAKE CONTROL INSTRUCTION MANUAL READY-TO-RUN. w/ Adult Supervision

PLEASE READ THESE INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

FieldView External Charger. User Guide

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Installation Instructions Central Battery Units

FL2000 Termination/Splice Panels User Manual

NiMH / LiPo Fast Charger. owner s manual

G76x Direct Spark Ignition Controls

Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

Installation Guide Thermal Conductivity Detector Accessory 19232E

END USER TERMS OF USE

INSTALLATION INSTRUCTIONS AM rev. A

Altivar 61/71 Adjustable Speed Drives Plastic Kits and Power Terminal Kit

RANGER 900 POWER STEERING KIT

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

3-way multi-family drawout cable interlock kit - type 32 - RF

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Outdoor Sensor Assembly (Veris) Installation Instructions

Date: Order No.: Supersedes: Group:

Installation instructions

Installation Guide. Purged Packed Inlet, Electronic Pneumatics Control on 6890 GC Accessory G1551A

Model A Turn Signal Kit Installation Guide

Transcription:

CONSOLE MANAGEMENT CONTROLLER Installation Card For Door Lock Kit Read Instructions Completely Before Beginning Installation Procedures NOTICE Printed on recycled paper 00 Compaq Information Technologies Group, L.P. Compaq and the Compaq logo are trademarks of Compaq Information Technologies Group, L.P. Compaq shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided as is without warranty of any kind and is subject to change without notice. The warranties for Compaq products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty. Compaq Console Management Controller Door Lock Kit Installation Instructions Second Edition (December 00) Part Number 088-0 About This Device This document provides instructions to assist qualified personnel with the installation of the Compaq Console Management Controller (CMC) Door Lock Kit. This door lock kit includes the following features: Installs in the 9000 and 0000 series of Compaq racks. Mounts in a 0U configuration. Provides front and rear door locking control for a single rack. Regulatory Compliance Information This CMC Door Lock Kit is listed and certified for use only with the Compaq Console Management Controller Units. This device is not intended for use with nor suitable for connection to facility burglary protection, security, or surveillance systems. Regulatory certification for this product was obtained under agency series number EO009L. The corresponding part number is 009-B. Read Before Installing Product Read the Important Safety Information guide (included with this kit) before installing this product. WARNING: There is a risk of personal injury from electrical shock and hazardous energy levels. The installation of options and routine maintenance and service of this product must be performed by individuals who are knowledgeable about the procedures, precautions, and hazards associated with AC power products. Follow the instructions in this document during installation of the door lock kit. Kit Contents Door lock control unit - Mounting brackets (5766-00) Country-specific power cord Front rack door - Lock assembly - 9XX, 98, and 06XX (5766-00) - Latch assembly - 9XX and 06XX (5766-00) - 98 (5766-00) Rear rack door - Lock assembly - 9XX, 98, and 06XX (5766-00) - Latch assembly - 9XX and 98 (5766-00) - 06XX (5766-00) - Brackets - Standard rack (5766-00) - Standard rack with extension kit (5766-00) Tie wraps Cables - Concealed Door Release cable assembly (57658-00) - CMC lock command cable (95-00) - I C communication cable (56-00) Software - Compaq Intelligent Rack Manager Lite CD - Power Products Documentation CD Mounting hardware - Screws - Cage nuts 088-0

Connecting the Actuator Cable to the Lock Mechanism The actuator cables are attached to the door lock control unit. Use the short cable to connect to the front lock mechanism and the longer cable to connect to the rear lock mechanism. To connect to the front lock mechanism, feed the actuator cable through the gap between the rack rail and frame. Slide the lever and place the actuator cable into the opening, making sure to secure the end of the cable over the slot. Repeat procedure to connect to the rear lock mechanism. CAUTION: The actuator cable should be installed with a bend radius of at least 00 mm to avoid kinking the cable. Do not bend or squeeze the actuator cable. Adjusting the Lock Mechanism Turn the adjusting connector until the edge of the latch on the lock mechanism moves above the edge of the opening. Secure with the locknut. Installing the Door Lock Control Unit Position the control unit between a front and rear rail. Attach the brackets to the door lock control unit, using the M screws Attach the brackets to the rails using self-tapping screws. The control unit can face up or down depending on specific installation requirements. Continued on reverse

Installing the Front Door Lock Mechanism Connect the front door lock assembly to the side of the front frame. 9XX Series Rack with Extension Kit 0000 Series Rack Align the extension brackets (5766-00) on the rear door lock mechanism and secure with the screws. Position the rear door lock assembly as shown, so that the assembly extends towards the rear door. Insert the self-tapping plate screws to secure the rear door lock mechanism to the rack. To accommodate the double doors of a 06XX rack, unbolt the locking mechanism from the crossbar and reposition in the left hole pair as shown. (For the 9000 series rack, use the right hole pair.) Set the address switch to or on the door lock control unit to match the lock port that is connected to the CMC. Align the standard brackets (5766-00) on the rear door lock assembly Insert the self-tapping screws to secure the rear door lock mechanism to the rack. 5 Installing the Front Door Lock Latch Align the latch with the lock mechanism. Insert the screws with the backing plate through the holes in the front door of the rack. On the inside of the door, place the front door lock latch over the screws and secure with the hardware provided with this assembly. For 9XX and 06XX series racks, use latch assembly 5766-00. For the 98 series rack, use latch assembly 5766-00. the Concealed Door 9 Connecting Release Cable 98 Series Rack Attach long spacers to the rear rails using the cage nuts. Insert screws and washers to secure the door lock assembly to the long spacers. 7 Installing the Rear Door Lock Latch Align the latch with the lock mechanism. For 9XX and 98 series racks, use latch assembly (5766-00). For 06XX series racks, use latch assembly 5766-00. Insert the screws with the backing plate through the holes in the rear door of the rack. On the inside of the door, place the rear door lock latch over the screws, securing with the hardware provided in this assembly. The concealed door release button is designed to release the door locks manually if this feature is activated in the Compaq Intelligent Rack Manager Lite software. Connect the concealed door release cable assembly to the door lock control unit unlock port. Route the cable through the rack and locate the push button in a concealed location. (This is a suggested location.) 98 Series Rack - Front and Rear Doors Reversed 6 Installing the Rear Door Lock Mechanism Insert the screws to secure the short spacers and the rear door lock assembly to the front rails as shown, using screws, washers and nuts. 0 Connecting the Power Cord 8 Connecting to the CMC 9XX Series Rack Align the standard brackets (5766-00) on the rear door lock assembly Insert the self-tapping screws to secure the rear door lock mechanism to the rack. Connect the country-specific power cord to the socket on the door lock control unit. Power off the CMC, then connect the IC cable from the CMC to one of the IC ports on the door lock control unit. Connect the cable from the CMC lock port or, to the lock port on the door lock control unit. The cables can be routed through the rack and then attached by using tie wraps. Continued on next page

Installing the Front Door Lock Mechanism Connect the front door lock assembly to the side of the front frame. 9XX Series Rack with Extension Kit 0000 Series Rack Align the extension brackets (5766-00) on the rear door lock mechanism and secure with the screws. Position the rear door lock assembly as shown, so that the assembly extends towards the rear door. Insert the self-tapping plate screws to secure the rear door lock mechanism to the rack. To accommodate the double doors of a 06XX rack, unbolt the locking mechanism from the crossbar and reposition in the left hole pair as shown. (For the 9000 series rack, use the right hole pair.) Set the address switch to or on the door lock control unit to match the lock port that is connected to the CMC. Align the standard brackets (5766-00) on the rear door lock assembly Insert the self-tapping screws to secure the rear door lock mechanism to the rack. 5 Installing the Front Door Lock Latch Align the latch with the lock mechanism. Insert the screws with the backing plate through the holes in the front door of the rack. On the inside of the door, place the front door lock latch over the screws and secure with the hardware provided with this assembly. For 9XX and 06XX series racks, use latch assembly 5766-00. For the 98 series rack, use latch assembly 5766-00. the Concealed Door 9 Connecting Release Cable 98 Series Rack Attach long spacers to the rear rails using the cage nuts. Insert screws and washers to secure the door lock assembly to the long spacers. 7 Installing the Rear Door Lock Latch Align the latch with the lock mechanism. For 9XX and 98 series racks, use latch assembly (5766-00). For 06XX series racks, use latch assembly 5766-00. Insert the screws with the backing plate through the holes in the rear door of the rack. On the inside of the door, place the rear door lock latch over the screws, securing with the hardware provided in this assembly. The concealed door release button is designed to release the door locks manually if this feature is activated in the Compaq Intelligent Rack Manager Lite software. Connect the concealed door release cable assembly to the door lock control unit unlock port. Route the cable through the rack and locate the push button in a concealed location. (This is a suggested location.) 98 Series Rack - Front and Rear Doors Reversed 6 Installing the Rear Door Lock Mechanism Insert the screws to secure the short spacers and the rear door lock assembly to the front rails as shown, using screws, washers and nuts. 0 Connecting the Power Cord 8 Connecting to the CMC 9XX Series Rack Align the standard brackets (5766-00) on the rear door lock assembly Insert the self-tapping screws to secure the rear door lock mechanism to the rack. Connect the country-specific power cord to the socket on the door lock control unit. Power off the CMC, then connect the IC cable from the CMC to one of the IC ports on the door lock control unit. Connect the cable from the CMC lock port or, to the lock port on the door lock control unit. The cables can be routed through the rack and then attached by using tie wraps. Continued on next page

Connecting to an Additional Rack Configuring the Software A single CMC can support up to two door lock kits. Repeat steps through 7 to complete installation of the door lock equipment for the second rack. Connect the second I C cable between the two door lock control units. Connect the cable from the lock port to the open CMC lock port. Set the switch on the door lock control unit to match the lock port used on the CMC. Connect the second concealed door release cable and the AC power cable as detailed in steps 9 and 0. For translated documents, refer to the PPD CD included with the option kit. Configure the door lock control unit using the Compaq Intelligent Rack Manager Lite software (see the Compaq Console Management Controller User Guide). One CMC is able to support up to two door lock kits. DOORS AND SENSORS: For each door lock kit, select the doors that must be closed before the lock should activate. Intrusion sensors must monitor these selected doors. From the Accessory Setup screen of the Compaq Intelligent Rack Manager Lite software, select at least one door for each lock kit. Each door lock control unit locks and unlocks, as a pair, the front door and the rear door of a single rack. For a secure rack, the system should verify that the front and rear doors are closed before the lock activates. The intrusion sensors indicate to the system that the doors are closed and are ready to be locked. PRESETS: From the Accessory Setup screen, preset the lock response to four fault conditions: Power Failure Low Battery Network Failure Communication Failure Hardware installation is complete. LED Configuration The door lock control unit has the following LEDs. Power LED Green - On I C Communication LED/Status LED Green flashing - Communication Traffic Red flashing - System Error or Battery Charging If any of these faults occur, the door lock control unit responds by keeping the doors locked, or by immediately unlocking the doors, or by enabling the Concealed Door Release button, as selected in the software. SETUP EXAMPLE: Power Failure No Low Battery Yes Network Failure Enable Concealed Door Release Communication Failure Enable Concealed Door Release The rack remains locked if the door lock control unit loses AC power. The door lock control unit continues to operate using the backup battery power. NOTE: If the CMC also loses AC power, you will not be able to change any settings. If the AC power is not restored within approximately six hours, the Low Battery alert is triggered and the doors unlock. This alert ensures that sufficient battery power is reserved to unlock the doors. After 0 minutes, the door lock control unit stops functioning. When the AC power is restored, the door lock control unit automatically relocks all the doors and begins recharging the batteries. If the CMC detects a network failure, the doors can be opened by pressing the Concealed Door Release button. The CMC determines a Network Failure has occurred if the CMC fails to communicate with the Compaq Intelligent Rack Manager Lite software for approximately four minutes. NOTE: If you are using management software other than Compaq Intelligent Rack Manager Lite, ensure that the Network Failure condition is selected as No. If the Compaq Intelligent Rack Manager Lite service is not running on the management console, the CMC detects a Network Failure and responds accordingly. If the CMC loses communication with the door lock control unit, a communication failure will be triggered. The doors can then be opened by pressing the Concealed Door Release button.

Maintenance WARNING: To reduce the risk of injury from electric shock, remove the power cord before servicing. When the CMC indicates that the batteries in the door lock control unit require changing, remove the screws, lift the cover off, and replace the six batteries with the same type and capacity (NiMH, size AA, 00mAh). CAUTION: There is a risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries properly. If the fuse has opened, be sure that the condition that caused the fault has been cleared. Remove the fuse cover. Replace the fuse with the exact rating as specified on the unit label. The second fuse is a spare. Contact your Compaq authorized service representative for more details. Repairs to the CMC door lock control unit and lock mechanism must be carried out by Compaq or a Compaq authorized service representative.