DECOUPLING MODULE. Input to output voltage drop

Similar documents
CS5.241, CS5.241-C1, CS5.241-S1

POWER SUPPLY CS5.241-S1 CS5.244

POWER SUPPLY CS S1 CS10.481

1606-XLE240EN 24V,10A Single Phase Input

1606-XLE240E 24V,10A Single Phase Input

Bulletin 1606 Switched Mode Power Supplies

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

SHORT-FORM DATA MARKINGS

SHORT-FORM DATA MARKINGS

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

UZK12.071, UZO GENERAL DESCRIPTION 2. DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

QS GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS POWER SUPPLY 12V, 15A, SINGLE PHASE INPUT 1/22.

UZK12.071, UZO DATA 1. GENERAL DESCRIPTION 4. MARKINGS 3. ORDER NUMBERS PASSIVE BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

SHORT-FORM DATA MARKINGS

POWER SUPPLY QS QS20.481

SHORT-FORM DATA MARKINGS

POWER SUPPLY SHORT-FORM DATA MAJOR AGENCY APPROVALS

DC/DC CONVERTER. Spring-clamp terminals, Input-low, DC-OK contacts

SHORT-FORM DATA MARKINGS

UZK24.121, UZO GENERAL DESCRIPTION 2. DATA 4. MARKINGS 3. ORDER NUMBERS

Industrial Power Supplies

SHORT-FORM DATA MARKINGS

Safety Standards. Model Number:

SHORT-FORM DATA MARKINGS

SHORT-FORM DATA MARKINGS

QS20.241, QS C1

SHORT-FORM DATA MARKINGS

UB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS DC-UPS CONTROL UNIT 24V, 10A, DC-UPS 1/21.

DC-UPS CONTROL UNIT SHORT-FORM DATA

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Bulletin 1606 Switched Mode Power Supplies

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

CT10.241, CT C1

UZB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY REPLACEMENT BATTERY REPLACEMENT 12V, 12AH 1/6.

DC-UPS CONTROL UNIT SHORT-FORM DATA MARKINGS

Power Supplies. SDN-C Compact DIN Rail Series

UB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS DC-UPS CONTROL UNIT 1/23 PRELIMINARY. UB-Series Related products

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

QUINT-PS/24DC/24DC/ 5/CO

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

QUINT-PS/24DC/24DC/20

QUINT-PS/24DC/48DC/ 5

Features. Description. Table of Contents

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

QUINT-PS/24DC/24DC/10

MINI MCR-SL-UI-UI(-SP)

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A

PEL power supplies. 24 Vdc 18 Vdc 12 Vdc SWITCHED MODE POWER SUPPLIES/ PEL SERIES

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

MINI MCR-SL-UI-UI(-SP)(-NC)

DX³ RCCBs - ID 4P up to 100 A

Dependable innovative. partner. efficiency achieved. global flexible industry Leadership.

MD60 Series 60W DINergy Power Supply

Model Number Structure

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

QUINT-PS/48DC/24DC/5. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A.

D R C- 4 0 s e r i e s

Load (2) Single or Dual

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

GB60S 60W Single Output General Purpose Series

DRB-1 Series Instruction Manual

DIN RAIL POWER SUPPLIES SELECTION GUIDE

TX³ RCCBs 2P up to 100 A

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~300 Vdc

AC/DC Converter MBP250-2A13D13M

Switching Power Supplies

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

DC (on) LED Signal. Multiple output connector for easy wiring

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Glossary/Technical appendix

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8

QUINT-PS/24DC/24DC/10/CO

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

up to 63 A (1 module per pole)

Video & Power Over Coax Kit

Powerware Vdc Extended Battery Cabinet User s Guide.

LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request

DIN Rail Power Supplies

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

Packaging (1) Package

MODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

RP40- _FR/ Package (4) CTRL Logic (3)

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Solid State Relays, 3-phase

EMERGENCY VEHICLE BATTERY MANAGER PS2024

Transcription:

DECOUPLING MODULE Dual input, single output Two diodes (common cathode) Rugged metal housing Width only 32mm Cost effective solution to build redundant systems 1-6V Wide-range input 2A Continuous output current Easy wiring; Distribution terminals for negative pole included Quick-connect spring-clamp terminals 1. GENERAL DESCRIPTION 2. SHORT-FORM DATA The YR2.DIODE is a decoupling module, which can be used for various purposes. The most popular application is to configure a highly reliable and true redundant power supply systems. Another interesting application is the separation of sensitive loads from non-sensitive loads. This avoids the distortion of the power quality for the sensitive loads which can cause controller failures. The YR2.DIODE is the perfect solution to use in a redundant system, if the power supply itself is equipped with a DC-OK signal (e.g.: DIMENSION Q- Series). Alongside with the YR2.DIODE, there exists the YRM2.DIODE which has a monitoring circuitry included. LEDs and relay contacts signal when one of the two DC-input voltages is not in range due to a non-functioning power supply. Input voltage DC 24V Input voltage range 1-6Vdc Input current 2x 12.5A 1+1 Redundancy 2x 1A N+1 Redundancy 1x 2A Single use Output current max. 2A Normal mode max. 25A / shortcircuit Input to output voltage drop typ..85v At 2A output current losses W At no load 17W At 2A output current Unique quick-connect spring-clamp terminals allow a Temperature range -25 C to +7 C Operational safe and fast installation and a large international Derating.5A/ C +6 to +7 C approval package for a variety of applications makes this unit suitable for nearly every situation. Dimensions 32x124x12mm WxHxD 3. ORDER NUMBERS 4. MARKINGS Accessory YR2.DIODE Dual input / single output ZM1.WALL Wall / panel mount bracket ZM11.SIDE Side mount bracket GL IND. CONT. EQ. UL 58 UL 695-1 Class I Div 2 Marine EMC, LVD www.pulspower.com Phone +49 89 9278 Germany 1/16

INDEX PAGE INDEX PAGE 1. General Description...1 2. Short-form Data...1 3. Order Numbers...1 4. Markings...1 5. Input and Output Characteristics...3 6. Losses...4 7. Reliability...4 8. Functional Diagram...5 9. Front Side and User Elements...5 1. Terminals and Wiring...6 11. EMC...6 12. Environment...7 13. Protection Features...8 14. Safety...8 15. Dielectric Strength...8 16. Approvals...9 17. Fulfilled Standards... 9 18. Used Substances... 9 19. Physical Dimensions and Weight... 1 2. Installation and Operation Instructions... 1 21. Accessory... 11 22. Application Notes... 12 22.1. Recommendations for Redundancy... 12 22.2. 1+1 Redundancy up to 1A... 12 22.3. 1+1 Redundancy up to 2A... 13 22.4. N+1 Redundancy, Example with 2A... 13 22.5. Battery Back-up... 14 22.6. Redundancy for Sensitive s... 14 22.7. of Buffered Branches... 15 22.8. Use in a Tightly Sealed Enclosure... 15 22.9. Mounting Orientations... 16 INTENDED USE The decoupling module shall only be installed and put into operation by qualified personnel. This decoupling module is designed for installation in an enclosure and is intended for the general use, such as in industrial control, office, communication, and instrumentation equipment. Do not use this device in aircraft, trains and nuclear equipment, where malfunctioning of the power supply may cause severe personal injury or threaten human life. TERMINOLOGY AND ABREVIATIONS PE and symbol PE is the abbreviation for Protective Earth and has the same meaning as the symbol. Earth, Ground This document uses the term earth which is the same as the U.S. term ground. T.b.d. To be defined, value or description will follow later. DC 24V A figure displayed with the AC or DC before the value represents a nominal voltage with standard tolerances (usually ±2%) included. E.g.: DC 12V describes a 12V battery disregarding whether it is full (13.7V) or flat (1V) 24Vac A figure with the unit (Vac) at the end is a momentary figure without any additional tolerances included. DISCLAIMER The information presented in this document is believed to be accurate and reliable and may change without notice. 2/16

5. INPUT AND PUT CHARACTERISTICS Number of inputs nom. 2 Number of outputs nom. 1 Input voltage nom. DC 24V Input voltage range - 1-6Vdc Voltage drop, input to output typ..85v At 2x1A, see Fig. 5-1 Input current max. 2x 12.5A Continuous, 1+1 Redundancy, see Fig. 5-2 max. 2x 1A Continuous, N+1 Redundancy, see Fig. 5-3 max. 1x 2A Continuous, Single use, see Fig. 5-4 Input current max. 2x 18.5A Up to 5s, 1+1 Redundancy, continuous, see Fig. 5-2 max. 2x 15A Up to 5s, N+1 Redundancy, continuous, see Fig. 5-3 max. 1x 3A Up to 5s, Single use, continuous, see Fig. 5-4 Peak input current max. 15A Max. 1ms, per input Output current max. 2A / 3A Normal mode, continuous / up to 5s max. 25A / 37.5A At overload or short-circuit, continuous / up to 5s Reverse current max. 2mA Per input, -25 C to +6 C Reverse voltage max. 2Vdc Voltage applied to the output, continuously allowed Note: Ensure that the continuous output current does not exceed 25A. Check the short-circuit current of the power sources and if the power source can deliver more than 25A, use an appropriate fuse on the output. Fig. 5-1 Voltage Drop Input to Output Voltage Drop, typ. 1.2V 1..8.6.4.2 Output Current 5 1 15 2 25A Fig. 5-2 1+1 Redundancy AC AC DC DC IN 1 IN 2 + - Fig. 5-3 N+1 Redundancy Fig. 5-4 Single use (redundant) AC AC AC AC AC AC AC AC DC DC DC DC DC DC DC DC IN 1 IN 2 IN 1 IN 2 IN 1 IN 2 IN 1 IN 2 IN 1 IN 2 + - + - 3/16

6. POWER LOSSES losses typ. 3.6W 1-6Vdc, 5A output current, see Fig. 6-1 typ. 7.85W 1-6Vdc, 1A output current, see Fig. 6-1 typ. 17.W 1-6Vdc, 2A output current, see Fig. 6-1 Fig. 6-1 losses vs. output current Losses, typ. 24W 2 16 12 8 4 Output Current 5 1 15 2 25A 7. RELIABILITY DC 24V Lifetime expectancy min. > 25 years 4 C, input: 2x1A, output: 2A, no electrolytic capacitors involved min. > 25 years 4 C, input: 2x5A, output: 1A, no electrolytic capacitors involved min. > 25 years 25 C, input: 2x1A, output: 2A, no electrolytic capacitors involved MTBF SN 295, IEC 6179 46 5 h 4 C, input: 2x1A, output: 2A 7 h 25 C, input: 2x1A, output: 2A MTBF MIL HDBK 217F 36 2 h 4 C, input: 2x1A, output: 2A, Ground Benign GB4 41 1 h 25 C, input: 2x1A, output: 2A, Ground Benign GB25 The Lifetime expectancy shown in the table indicates the operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours. Lifetime expectancy is calculated according to the capacitor s manufacturer specification. The prediction model allows a calculation of up to 15 years from date of shipment. MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a device. It is the statistical representation of the likelihood of the unit to fail and does not necessarily represent the life of a product. 4/16

8. FUNCTIONAL DIAGRAM Fig. 8-1 Functional diagram V IN 1 V IN 2 + - + - + - V Chassis Ground 9. FRONT SIDE AND USER ELEMENTS Input Terminals Quick-connect spring-clamp terminals, no tools required + Positive input - Negative (return) input Fig. 9-1 Front side Output Terminals Quick-connect spring-clamp terminals, no tools required + Positive output - Negative (return) output Chassis ground. Optionally to connect to PE See chapter 1 Terminals and Wiring to choose appropriate wire gauges 5/16

1. TERMINALS AND WIRING Type Bi-stable, quick-connect spring clamp terminals. IP2 Finger safe construction. Suitable for field- and factory installation. Shipped in open position. Solid wire.5-6mm 2 Stranded wire.5-4mm 2 American wire gauge 2-1 AWG Ferrules Allowed, but not required Wire stripping length 1mm /.4inch Pull-out force 1AWG:8N, 12AWG:6N, 14AWG:5N, 16AWG:4N (according to UL486E) Fig. 1-1 Connecting a wire 1. Insert the wire 2. Snap the lever To disconnect wire: same procedure vice versa Instructions: a) Use appropriate copper cables that are designed for an operating temperature of: 6 C for ambient up to 45 C and 75 C for ambient up to 6 C minimum. b) Follow national installation codes and installation regulations! c) Ensure that all strands of a stranded wire enter the terminal connection! d) Up to two stranded wires with the same cross section are permitted in one connection point (except PE wire). e) Do not use the unit without PE connection. 11. EMC The decoupling module is suitable for applications in industrial environment as well as in residential, commercial and light industry environment without any restrictions. CE mark is in conformance with EMC guideline 89/336/EEC and 93/68/EEC and the low-voltage directive (LVD) 73/23/EWG. A detailed EMC Report is available upon request EMC Immunity EN 61-6-1 EN 61-6-2 Generic standards Electrostatic discharge EN 61-4-2 Contact discharge Air discharge 8kV 15kV Criterion A Criterion A Electromagnetic RF field EN 61-4-3 8MHz-1GHz 1V/m Criterion A Fast transients (Burst) EN 61-4-4 Input Output 2kV 2kV Criterion A Criterion A Conducted disturbance EN 61-4-6.15-8MHz 1V Criterion A Criterions: A: Device shows normal operation behavior within the defined limits. EMC Emission EN 61-6-3 and EN 61-6-4 Generic standards Conducted emission EN 5511, EN 5522, FCC Part 15, CISPR 11, CISPR 22 Class B, input lines EN 5522 Class B, output lines Radiated emission EN 5511, EN 5522 Class B This device complies with FCC Part 15 rules. Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 6/16

12. ENVIRONMENT Operational temperature -25 C to +7 C (-13 F to 158 F) Reduce output power above +6 C Output de-rating.5a/ C 6-7 C (14 F to 158 F), see Fig. 12-1 Storage temperature -4 C to +85 C (-4 F to 185 F) Storage and transportation Humidity 5 to 95% r.h. IEC 668-2-3 Do not energize while condensation is present Vibration sinusoidal 2-17.8Hz: ±1.6mm; 17.8-5Hz: 2g 2 hours / axis IEC 668-2-6 Vibration random.5m 2 (s 3 ) IEC 668-2-64 2 hours / axis Shock 3g 6ms, 2g 11ms IEC 668-2-27 3 bumps / direction, 18 bumps in total Altitude to 6m ( to 2 ft) Reduce output power or ambient temperature above 2m sea level. Output de-rating (for altitude) 1.25A/1m or 5 C/1m Above 2m (65ft), see Fig. 12-2 Over-voltage category III EN 5178, (for clearance and creepage distances) Degree of pollution 2 EN 5178, not conductive Fig. 12-1 Output current vs. ambient temp., Allowed Output Current 3A 25 2 15 overload / short circuit normal mode 1 5 Ambient Temperature -25 2 4 6 7 C Fig. 12-2 Output current vs. altitude Allowed Output Current 3A 25 2 15 1 overload / short circuit A... Tamb < 6 C B... Tamb < 5 C C... Tamb < 4 C normal mode A B C 5 Altitude 2 4 6m The ambient temperature is defined as the air temperature 2cm below the unit. 7/16

13. PROTECTION FEATURES Output over-current protection not included Degree of protection IP 2 EN/IEC 6529 Penetration protection > 3.5mm E.g. screws, small parts Over-temperature protection no Input transient protection no Internal input fuse not included Note: In case of a protection event, audible noise may occur. 14. SAFETY Input / output separation 2V Epitaxial diode Class of protection III PE (Protective Earth) connection not mandatory PE resistance <.1Ohm Between housing and PE terminal 15. DIELECTRIC STRENGTH Fig. 15-1 Dielectric strength A Type test 6s 5Vac Factory test 5s 5Vac Field test 5s 5Vac In- / Output Chassis Type tests and factory tests: + A Conducted by the manufacturer. Do not repeat test in field! - Rules for field test: Use appropriate test equipment which applies the voltage with a slow ramp! During testing, connect all output and input poles together. The input and output voltage is floating and has no ohmic connection to ground. 8/16

16. APPROVALS UL 58 IND. CONT. EQ. LISTED E198865 listed for use in U.S.A. (UL 58) and Canada (C22.2 No. 14-95) Industrial Control Equipment UL 695-1 RECOGNIZED E1376 recognized for the use in U.S.A. (UL 695-1) and Canada (C22.2 No. 695) Information Technology Equipment UL 164 RECOGNIZED E246877 recognized for use in U.S.A. (UL 164) and Canada (C22.2 No. 213-M1987) Hazardous Location Class I Div 2 T4 Groups A,B,C,D and Class I Zone 2 Groups IIA, IIB and IIC Marine The unit is suitable for use in Class I Division 2 Groups A, B, C, D locations as well as for Class I Zone 2 Groups IIA, IIB and IIC locations. Substitution of components may impair suitability for Class I Division 2 environment. Do not disconnect equipment unless power has been switched off. Wiring must be in accordance with Class I, Division 2 wiring methods of the National Electrical Code, NFPA 7, and in accordance with other local or national codes. GL ABS GL (Germanischer Lloyd) classified and ABS (American Bureau for Shipping) PDA for marine and offshore applications. Environmental category: C, EMC2 17. FULFILLED STANDARDS EN/IEC 624-1 EN/IEC 61131-2 EN 5178 Safety of Electrical Equipment of Machines Programmable Controllers Electronic Equipment in Installations 18. USED SUBSTANCES The unit does not release any silicone and is suitable for the use in paint shops. Electrolytic capacitors included in this unit do not use electrolytes such as Quaternary Ammonium Salt Systems. Plastic housings and other molded plastic materials are free of halogens, wires and cables are not PVC insulated. The production material within our production does not include following toxic chemicals: Polychlorized Biphenyl (PCB), Polychlorized Terphenyl (PCT), Pentachlorophenol (PCP), Polychlorinated naphthalene (PCN), Polybrom Biphenyll (PBB), Polybrom Bipheny-oxyd (PBO), Polybrominated Diphenylether (PBDE), Polychlorinated Diphenylether (PCDE), Polydibromphenyl Oxyd (PBDO), Cadmium, Asbest, Mercury, Silicia 9/16

19. PHYSICAL DIMENSIONS AND WEIGHT Weight 29g /.64lb DIN-Rail Use 35mm DIN-rails according to EN 6715 or EN 522 with a height of 7.5 or 15mm. The DIN-rail height must be added to the depth (12mm) to calculate the total required installation depth. Electronic files with mechanical data can be downloaded at www.pulspower.com Fig. 19-1 Front view Fig. 19-2 Side view 2. INSTALLATION AND OPERATION INSTRUCTIONS Mounting Orientation: Input terminal must be located on top and output terminal on the bottom. For other orientations see section 22.9 Cooling: Convection cooled, no forced cooling required. Do not cover ventilation grid (e.g. cable conduits) by more than 3%! Installation clearances: 4mm on top, 2mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. Risk of electrical shock, fire, personal injury or death! Turn power off before working on the module. Protect against inadvertent re-powering. Make sure the wiring is correct by following all local and national codes. Do not open, modify or repair the unit. Use caution to prevent any foreign objects from entering into the housing. Do not use in wet locations or in areas where moisture or condensation can be expected. Service parts: The unit does not contain any serviceable parts. 1/16

21. ACCESSORY ZM1.WALL Wall mounting bracket This bracket is used to mount Dimension units onto a flat surface without utilizing a DIN-Rail. The two aluminum brackets and the black plastic slider of the unit have to be detached, so that the two steel brackets can be mounted. Fig. 21-1 ZM1.WALL Wall Mounting Bracket Fig. 21-2 Assembled Wall Mounting Bracket ZM11.SIDE Side mounting bracket This bracket is used to mount Dimension units sideways with or without utilizing a DIN-Rail. The two aluminum brackets and the black plastic slider of the unit have to be detached, so that the steel brackets can be mounted. For sideways DIN-rail mounting, the removed aluminum brackets and the black plastic slider need to be mounted on the steel bracket. Fig. 21-3 ZM11.SIDE Side Mounting Bracket (Picture shows a mounted QS1 power supply) Fig. 21-4 Side Mounting with DIN-rail brackets (Picture shows a mounted QS1 power supply) 11/16

22. APPLICATION NOTES 22.1. RECOMMENDATIONS FOR REDUNDANCY Recommendations for the configuration of redundant power systems: Use separate input fuse for each power supply. It is desirable to set the output voltages of all power supplies to the same value to avoid a false signal of the DC-ok signal. Use Three-phase power supplies to gain functional safety if one phase fails. When Single-phase power supplies are utilized connect them to different phases or mains circuits. Use both inputs in parallel for currents above 1A. 22.2. 1+1 REDUNDANCY UP TO 1A 1+1 Redundancy up to 1A requires two 1A power supplies and one YR2.DIODE decoupling module. Fig. 22-1 Wiring diagram, 1+1 Redundancy, 1A output current Failure Monitor + - 24V/1A Adj QS1.241 + - 24V/1A Adj QS1.241 IN 1 IN 2 YR2.Diode L N PE L N PE L N PE I I optional 1A 12/16

22.3. 1+1 REDUNDANCY UP TO 2A 1+1 Redundancy up to 2A requires two 2A power supplies and two YR2.DIODE decoupling modules. Fig. 22-2 Wiring diagram, 1+1 Redundancy, 2A output current Failure Monitor + - 24V/2A Adj QT2.241 IN 1 IN 2 YR2.Diode + - 24V/2A Adj QT2.241 IN 1 IN 2 YR2.Diode L1 L2 L3 PE L1 L2 L3 PE L1 L2 L3 PE I I I optional I I I optional 2A 22.4. N+1 REDUNDANCY, EXAMPLE WITH 2A N+1 Redundancy with 2A requires three 1A power supplies and two YR2.DIODE decoupling modules. Please note: The DC-ok signal on the DIMENSION Q-Series will only work properly if the adjusted output voltage of each power supply will be reached after turning-on the input power. A power supply operating in current limiting mode will result in a DC-fail condition. Read notes in the individual power supply datasheets. Fig. 22-3 Wiring diagram, N+1 Redundancy, example with 2A load current Failure Monitor + - 24V/1A Adj QS1.241 + - 24V/1A Adj QS1.241 IN 1 IN 2 YR2.Diode + - 24V/1A Adj QS1.241 IN 1 IN 2 YR2.Diode L N PE L N PE L N PE I I I L N PE optional 2A 13/16

22.5. BATTERY BACK-UP A battery back-up with 1A requires one 1A power supply and one YR2.DIODE decoupling module. Please note: Set output voltage of power supply to 26.5Vdc minimum to avoid that the charger current flows to the load instead of charging the battery. Use a fuse between battery and YR2.DIODE! Fig. 22-4 Wiring diagram, 1A Battery back-up I + 24V Battery Battery Charger - + - 24V/1A Adj QS1.241 L N PE IN 1 YR2.Diode IN 2 Failure Monitor L N PE optional 1A 22.6. REDUNDANCY FOR SENSITIVE LOADS Cost effective solution to get redundant power for a PLC or controller system. Standard design: PS1 PS2 PLC Improved approach: PS1 PS2 YR2 PLC Fig. 22-5 Wiring diagram, Redundancy for Sensitive s Failure Monitor Heavy s e.g. Motors + - 24V/2A Adj QT2.241 L1 L2 L3 PE IN 1 YR2.Diode IN 2 + - 24V 5A Adj QS5.241 L N PE L1 L2 L3 N PE I I I I optional Sensitive e.g. Controller 14/16

22.7. DECOUPLING OF BUFFERED BRANCHES Buffer energy supplied from a DC-UPS or buffer module is not wasted in power branches. Please note: Set output voltage of the power supply to a level that the buffer unit or DC-UPS will not start unexpected. Take the voltage drop of the YR2.DIODE into account. Fig. 22-6 Wiring diagram, of Buffered Branches Failure Monitor e.g. Motor L1 L2 L3 PE + - 24V/2A Adj QT2.241 L1 L2 L3 PE I I I IN 1 YR2.Diode optional IN 2 Buffer Buffered e.g. Controller 22.8. USE IN A TIGHTLY SEALED ENCLOSURE When the decoupling module is installed in a tightly sealed enclosure, the temperature inside the enclosure will be higher than outside. The inside temperature defines the ambient temperature for the decoupling module. Results from such an installation: supply is placed in the middle of the box, no other heat producer inside the box Enclosure: Rittal Typ IP66 Box PK 9516 1, plastic, 11x18x165mm : 24V, 16A; (=8%) load is placed outside the box Input: 24Vdc Temperature inside enclosure: 57.8 C (in the middle of the right side of the power supply with a distance of 2cm) Temperature outside enclosure: 24.6 C Temperature rise: 33.2K 15/16

22.9. MOUNTING ORIENTATIONS Mounting orientations other than vertical require a reduction in continuous output current or a limitation in the max. allowed ambient temperature. The amount of reduction influences the lifetime expectancy of the power supply. Therefore, two different derating curves for continuous operation can be found below: Curve A1 Recommended output current. Curve A2 Max allowed output current (results approx. in half the lifetime expectancy of A1). Fig. 22-7 Mounting Orientation A Standard Orientation INPUT PUT Output Current 2A 16 12 8 4 Ambient Temperature 1 2 3 4 5 6 C A1 Fig. 22-8 Mounting Orientation B (Upside down) PUT INPUT Output Current 2A 16 12 8 4 Ambient Temperature 1 2 3 4 5 6 C A1 Fig. 22-9 Mounting Orientation C (Table-top mounting) Output Current 2A 16 12 8 4 Ambient Temperature 1 2 3 4 5 6 C A2 A1 Fig. 22-1 Mounting Orientation D (Horizontal cw) PUT INPUT Output Current 2A 16 12 8 4 Ambient Temperature 1 2 3 4 5 6 C A2 A1 Fig. 22-11 Mounting Orientation E (Horizontal ccw) INPUT PUT Output Current 2A 16 12 8 4 Ambient Temperature 1 2 3 4 5 6 C A2 A1 16/16