G2 Portable oxygen concentrator User Manual

Similar documents
USER MANUAL READ THIS MANUAL BEFORE OPERATING THIS DEVICE. SAVE THIS MANUAL FOR FUTURE REFERENCE. DEALER: THIS MANUAL MUST BE GIVEN TO THE END USER.

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

portable ac/dc suction pump USER S MANUAL ITEM # 18605

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Installation and Operation Back-UPS BX550CI-CN

Uninterruptible Power System

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Installation and Operation Manual Back-UPS BX1100CI-CN

General Precautions. Personnel Precautions

SECTION 8 TROUBLESHOOTING GUIDE

PI1500X Power Inverter User s Manual

YSmart Technology Co., Ltd. User Manual. GTI Grid Series. GTI Series Inverters for Grid-connected PV system

USER MANUAL MPS 1-5KW SERIES

UTILITY INPUT MAINS OUTLET

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

400 Watt Backup Power System Owner s Manual

Power Inverter 400 MW Owner s Manual

user s manual Model number

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

BC-9000 OPERATIONS MANUAL BATTERY CHARGER COFKO ELECTRONICS LLC COPYRIGHT 2014 P/N

user manual A OxyGoFit-User-Manual-English-Only-Without-FAA-Without-CE.indb 1 9/12/ :44:04 AM

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

Techcon Systems TS500R-PC Controller For Positive Displacement PC Pump

General safety and installation information.

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

View our SimplyGo Mini Specifications. (add hyperlink to specifications section)

Smart Charger 12-24V 60A, 1600W

230VAC Power Inverter 400W Owner s Manual

Installation and Operation Manual Back-UPS BR800/1100CI-IN

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

OWNER S MANUAL POWER INVERTER

OPERATION & MAINTENANCE

Back-Up Sensor System

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

PAC 600 PAC 800 PAC 800 comfort

Matson Jump Starter Operator s Manual

Hydraulic Immediate Need Power Pack

SCC-MPPT Solar Charge Controller

Eclipse TM with autosat. Personal Ambulatory Oxygen System (PAOS) TM. User Manual

OPERATOR S MANUAL SINGLE PORT UNIVERSAL CAR CHARGER

Sola/Hevi-Duty S3K Series Mini-Tower UPS

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

CX-SERIES ADVANCED BATTERY CHARGER

SBC / 2140 / Stage Battery Charger User Manual

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

JUMP STARTER OPERATOR S MANUAL RA1900

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Eclipse 5 TM with autosat. Eclipse Oxygen System. User Manual

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

PLEASE READ THESE INSTRUCTIONS BEFORE USE

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

SAFETY WARNINGS AND GUIDELINES

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

OPERATION INSTRUCTIONS

AC Anywhere. User Manual. Power Inverter. (Class II product) Please read the installation and operations instructions before using the Power Inverters

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

SCC-MPPT Solar Charge Controller

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Table of Contents. Introduction. How Your Cobra Power Inverter Works. Rechargeable Appliances 1. Quick Checkout 2-3. Operation 4

WARNINGS, CAUTIONS AND NOTES

DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

POWER INVERTER 700 WATT / 1800 WATT PEAK

January 2016 Med Tips

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

User Manual PORTABLE JUMPSTARTER

Go Power! Manual. GP-Smart Charger

GSL Electronics Modified Sine Wave Power Inverters

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

SCC-MPPT Solar Charge Controller

Operating Instructions for Your Cobra 300 Watt POWER INVERTER M ODEL CPI 300. Nothing comes close to a Cobra

Uninterruptible Power Supply

OutdoorXUPS-600AHV-8364

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Solar Charge Controller

ISO9001 DC TO AC POWER INVERTER. DC 12V TO AC Instruction Manual Please read user manual before use. CAUTION

1000 Watt Pure Sine Wave Power Inverter, Users Manual

Powerware Vdc Extended Battery Cabinet User s Guide.

1100W PORTABLE GENERATOR

OWNER S MANUAL Please read this manual before operating your power supply

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

AUTO CHARGE D PUMP PLUS

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

User Manual. equinox TM. Model 4000

Transcription:

G2 Portable oxygen concentrator User Manual Table of contents 1. Introduction......2 2. Important Safety Rules....3 3. Unpack your Lovego... 4 4. User Controls & System Status Indicators... 5 5. Quick Start.....6 6. How to operate........ 7 7. How to operate with battery..........9 8. How to operate with battery.....10 9. Important Safety Rules...........11 10. Maintenance...........13 11. Trouble shooting..... 14 12. Specification.......... 16 Lovego, let s go along with love Do what you want to do 13. Warranty...17 14. Online support...18

Introduction Important Safety Rules Thank you for purchasing LoveGo G2 Portable Oxygen Concentrator! This unit produces oxygen purity range at 90%+5%/-3% with the adjustable flow from 1 to 5 settings. LoveGo G2 can meet the needs of oxygen therapy for 1-5LPM. It can be supplied by home power, car battery and lithium battery. If you have any other questions, we are happy to answer them for you. Make sure reading and understanding all the information contained in this guide before you operate your unit.

Let s Go Along With Love! Lovego Accessories Some parts are optional,some are sent as free gift. Please refer to the accessory list in the website User Con1trols

Let s Go Along With Love! How to Operate Your Lovego POC Quick Start 1 Connect the power code with the machine and wall power. 2 Turn on the power Switch. 4 Purity Indicator A: Green Lights: the concentrator produces oxygen at standard purity. B: Yellow Lights: the concentrator produces oxygen lower than 82%. C: Red Lights: the concentrator produces oxygen lower than 75% 3 Press to start the machine.

Let s Go Along With Love! 5 The humidifier: How to operate with battery and in the car A. make the air flow into the longer tube and out from the shot tube. B. make sure the water filled is pure water or cold boiled water, do not use the mineral water. C. make sure the water filled below Max line. 6 Bubble oxygen tube. A Put the second circle over the head, then set the first circle across the ears. B Adjust the tube to make sure the rectangle pasted on the upper lip. NOTE NOTE Before attempting to start a cold unit, let the unit reach the room temperature for 30 minutes. If you will not use the unit in a period of time, remove the power cord.

Let s Go Along With Love! Important Safety Rules When using electrical products, especially for children, basic safety precautions should always be followed. Read all instructions before using. Important information is highlighted by these terms: DANGER To reduce the risk of serious or fatal injury from electrical shock: 1. Do not use while bathing. 2. Do not place the product where can be splashed liquid or fall into bathtub, water or other liquid. 3. In the event of unit falling into water, do not reach for the machine. Turn off the home power immediately then send it to dealer or our authorized service center for examination and repair. Figure 6 1. Car power: Connecting the adapter (car inverter) with car cigarette lighter, then connected with electric code. 2. Battery Power: Connecting the battery with the Adapter (car inverter), then connected with electric cord. 3. Turn on the machine, it will work. The battery can last 61minutes after the full charge. 4. Don t use the battery when charging. 5. Learn more battery specification in the battery manual. 1. Check the electric rating in the unit label and wall outlet before connecting power cord. 2. Keep all electrical cords away from heated surfaces. 3. Do not operate this unit if it: has been dropped or knocked heavily. has been splashed liquid. has a damaged cord or plug. is not working properly This device produces high levels of oxygen, which promotes rapid burning. Do not allow smoking or open flames within 5 feet of this device and any oxygen delivery accessory. Do not use oil, grease or petroleum-based products on or near the unit. Disconnect the power cord from the electrical outlet before you clean or repair the unit.

If this unit is turned on but not in use, do not leave the Headset under covering or chair cushions. The oxygen will make the material flammable. Set the power switch to the off position when the Oxygen Concentrator is not in use. 1. Disconnect the Oxygen Concentrator Unit from all external power sources. 2. Wipe the cabinet with a clean cloth with any commercial (bacterial-germicidal) disinfectant. Air Intake Filter Change 1. Disconnect the Oxygen Concentrator Unit from all external power sources. 2. Open the Air Intake Cover. 3. Take out the Air Intake Filter. 4. Replace a new Air Intake Filter. 5. The Air Intake Filter should be changed every 3000 hours working. Do not remove cover of the machine! Only your dealer or our authorized technician should remove the cover. Do not use extension cords with this unit. Do not overload wall outlet. CAUTION Do not block the ventilation located on the back of unit. DANGER Electrical shock hazard Do not attempt to open or remove cabinet. If service is required, return unit to a qualified equipment provider or an authorized service center. Opening or tampering with the unit will void warranty. DANGER Electrical shock hazard Turn off the Unit and remove the Power Cord before maintenance. Clean the Cabinet Maintenance

Troubleshooting Problem Possible cause Recommended Solution Your Oxygen Concentrator contains no user-serviceable parts. If you believe your unit is not working properly, BEFORE YOU RETURN IT TO THE DEALER WHERE YOU PURCHASED IT, please take a few minutes to check for these possible causes: Problem Possible cause Recommended Solution The alarm is giving beeps, the green and red light is solid. System Shut Down HOT Concentrator temperature is too high and oxygen production is shutting down. Ensure the bottom outlet vents have clear access. If condition persists, switch to a backup source of oxygen and The alarm is giving beeps, the LCD AC power supply is not connected properly Check power supply connection The yellow light is solid. Oxygen low purity contact your equipment provider. Concentrator is producing oxygen at low level (<82%) Contact your equipment provider display doesn t light on Concentrator does not power on when pressing On/Off button No oxygen DC cable is not connected properly Power switch is turned off Cannula is not connected properly or is kinked or obstructed Check the battery connection at the inverter Check the inverter connection at cigarette lighter Check the power switch at the bottom Check cannula and its connection to concentrator nozzle The red light is solid more than 5 minutes The car inverter produces noise There is water in the capsule of oxygen cannula Oxygen purity low Fan Runs Pour out the water Concentrator is producing oxygen at low level (<72%) Contact your equipment provider The fun of inverter should work for dissipate heat Disconnect the oxygen tube with capsule. Battery run off Recharge battery or use spare battery

Specification Flow Settings 1-5 settings equal to 1-5LPM flow Oxygen Purity 90%+5%/-3% at any settings Outlet Pressure 8.5 PSI Sound Level 40 db (nominal) at flat table, 45dB when travelling. Size 9.1 in x 8.7 in x 12.8 in (23 cm x 22 cm x 32.5 cm) Weight 4.3kgs machine Remote controller Wireless, 10 meters circle through the walls User Interface Push buttons, back-lit liquid crystal display (LCD) Work Temperature 41 to 104 F (5 to 40 C) Relative Humidity 15 to 95% Altitude Up to 12,000 ft (3657m) Storage Temperature -4 to 140 F (-20 to 60 C) unit only Storage Humidity Up to 95%, non condensing Power Consumption 90W~100W AC Power Input 100 to 240 VAC, 50/60 Hz, 1.8 A max AC Power Output 14.8 VDC, 8 A max DC Power Input Input 11. to 16.8 VDC 20 A max DC Power Output 14.8 VDC, 8 A max Chemistry of Battery Lithium Ion 14.8 VDC (nominal) Battery Dimensions 6.1 in x 3.4 in x 2 in(15.5 cm x 8.5 cm x 5 cm) Battery Weight 1.5 lbs (0.7 kg) Battery Charge Time Approximately 4 to 5 hours Battery Duration Two hours at 1-5 any settings, extra battery is optional. O 2 concentration indicator Green Light=Normal, Yellow=Caution <82%, Red with Audible Alarm=Warning <75% Audible Alarm Sound 55 db (nominal) at 39 in (1m) distance Alarm type Loss of power, High temperature, Low Therapeutic O 2 Out Seven year limited warranty Warranty The compressor portion of the Lovego Oxygen Concentrator is warranted to be free from defective workmanship and parts for a period of two year from date of purchase. Any defective part(s) will be repaired or replaced at XXXXX option if the unit has not been tampered with or used improperly during that period. Make certain that any malfunction is not due to inadequate cleaning or failure to follow the instructions. If repair is necessary, contact your Lovego Equipment Provider for instructions. Online Support Any questions when using Lovego G2 portable oxygen concentrator, or feedback, suggestions and complaints. Email: info@oxy-concentrator.com Zendesk: You can submit ticket in our zendesk, we will reply to you within 24 hours Kyslik pro zivot, s.r.o. Pionyru 839, Frydek-Mistek,Czech republic TEL:420604606364