Numerical Simulation and Performance Analysis of Rotary Vane Compressors for Automobile Air Conditioner

Similar documents
Theoretical and Experimental Investigation of Compression Loads in Twin Screw Compressor

Study on Performance and Dynamics of Inverter Controlled Rotary Compressors

The Performance Optimization of Rolling Piston Compressors Based on CFD Simulation

CFD Analysis of Oil Discharge Rate in Rotary Compressor

Noise Reduction of Accumulators for R410A Rotary Compressors

Structural Analysis Of Reciprocating Compressor Manifold

Comparison Between Different Arrangements of Bypass Valves in Scroll Compressors

Influence of Cylinder Bore Volume on Pressure Pulsations in a Hermetic Reciprocating Compressor

Effects of Refrigerant Injection on the Scroll Compressor

A Novel Automotive Two-Stage A/C Compressor

Comparing FEM Transfer Matrix Simulated Compressor Plenum Pressure Pulsations to Measured Pressure Pulsations and to CFD Results

Numerical and Experimental Research on Vibration Mechanism of Rotary Compressor

Reduction of Oil Discharge for Rolling Piston Compressor Using CO2 Refrigerant

Research And Development Of Variable-Speed Scroll Compressor

Experimental Study Of The Oil Injection Screw Air Compressor

Developing a Compact Automotive Scroll Compressor

Performance Improvement of a Reciprocating Air Microcompressor

Availability Analysis For Optimizing A Vehicle A/C System

Development of Highly Efficient Compressor Series Driven by IPM Motors

A Study on the Starting Characteristics of a Reciprocating Compressor for a Household Refrigerator

Development of Scroll Compressor for 16HP VRF System

Forces Analysis of Rotary Vane Compressor for Automobile Air Conditioning System

Twin Screw Compressor Performance and Its Relationship with Rotor Cutter Blade Shape and Manufacturing Cost

Study of a Novel Compliant Suspension Mechanism in Low Side Type Scroll Compressor

Development of High Performance 3D Scroll Compressor

The Reduction of the Noise/Vibration Generated by the Discharge Valve System in Hermetic Compressor for Refrigerator

Lubrication Analysis of Journal Bearings in R410A Rotary Compressor

Development of DC Inverter Scroll Compressor used for Marine Container Refrigeration Unit

New Capacity Modulation Algorithm for Linear Compressor

A Two Stage-Double Acting Scroll Air Compressor

Development of High Efficiency Swing Compressor for R32 Refrigerant

A Prototype Oil-Less Compressor for the International Space Station Refrigerated Centrifuge

Numerical Investigation of the Gas Leakage through the Piston-Cylinder Clearance of Reciprocating Compressors

The Digital Simulation Of The Vibration Of Compressor And Pipe System

Dynamic Analysis of Roller and Vane of Inverter Controlled Rotary Compressors

An Experimental Analysis on the Flow Rate in Scroll Compressors

Spool Seal Design and Testing for the Spool Compressor

Optimum Rotor Geometrical Parameters in Refrigeration Helical Twin Screw Compressors

A Low Friction Thrust Bearing for Reciprocating Compressors

Transient Thermal Analysis of Screw Compressors, Part III: Transient Thermal Analysis of a Screw Compressor to Determine Rotor-to-Rotor Clearances

Small Oil Free Piston Type Compressor For CO2

Discharge Characteristics of an Oil Feeder Pump Using Nozzle Type Fluidic Diodes for a Horizontal Compressor Depending onthe Driving Speed

Compressor Noise Control

Design Parameters to Determine Tangential Vibration of Rotary Compressor

Theoretical and Experimental Evaluation of the Friction Torque in Compressors with Straddle Bearings

Development of a New Type Cylinder Head for Piston Compressors

Evaluation of methods to decrease the discharge temperature of R32 scroll compressor

Scroll Expander for Carbon Dioxide Cycle

Extending the Operation Range of Dry Screw Compressors by Cooling Their Rotors

Development and Application of a Software Package for the Design of Twin Screw Compressors

Transmission Error in Screw Compressor Rotors

Reducing the Fuel Consumption by Speed Control of the Air Conditioning Compressor

Investigation of Torque-Fluctuation Reducer Made of Permanent-Magnets for Screw Compressors

Important Parameters for Small, Twin-Screw Refrigeration Compressors

The Characteristics of LGE Linear Oscillating Motor

Development of a Low Noise Rotary Compressor

Reciprocating Air Microcompressor

ABSTRACT 1. INTRODUCTION

Characteristic of a Miniature Linear Compressor

COMPRESSIBLE FLOW ANALYSIS IN A CLUTCH PISTON CHAMBER

Oil Circulation Rate in Rotary Compressor: Its Measurement and Factors Affecting the Rate

Research of the Effectiveness of Use of New Mechanism in Reciprocating Compressors

Twin-Screw Compressor Performance and Suitable Lubricants with HFC-134a

Clearance Loss Analysis in Linear Compressor with CFD Method

Theoretical and Experimental Study of an Oil-Free Scroll Vapor Expander

A Study On The Oil Supply System Of A Horizontal Rotary Compressor With Vane Utilized For Oil Feeding

Dynamic Modeling of a Poppet Valve for use in a Rotating Spool Compressor

Infinitely Variable Capacity Control

Development of Rotary Compressor for Highefficiency CO2 Heat-pump Hot-Water Supply System

The Design Aspects of Metal- Polymer Bushings in Compressor Applications

A Large Modern High Speed Reciprocating Compressor

Developments in Dry Running Seals for Reciprocating Compressors

The Influence of Discharge Ports on Rotor Contact in Screw Compressors

Dynamic Simulation of the Impact Mechanism of Hydraulic Rock Drill Based on AMESim Yin Zhong-jun 1,a, Hu Yi-xin 1,b

Elimination of Instability in Modulating Capacity Reciprocating Compressor

Performance Analysis of a Sliding -Vane Rotary Compressor for a Household Refrigerator/Freezer

Study on Flow Characteristic of Gear Pumps by Gear Tooth Shapes

FEASIBILITY STYDY OF CHAIN DRIVE IN WATER HYDRAULIC ROTARY JOINT

Experimental Investigation of Damping Coefficient for Compressor Reed Valves

Theoretical Study of a Novel Multi Vane Rotary Compressor

Simulation Analysis of a Two Rolling Piston Expander Replacing Throttling Valve in Conventional Refrigerant Heat Pump System

The Built-In Sensor Bearing to Measure The Shaft Motion Of A Small Rotary Compressor For Air- Conditioning

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Influence of Volumetric Displacement and Aspect Ratio on the Performance Metrics of the Rotating Spool Compressor

On the Classification of Compressor,Pump or Engine Designs Using Generalized Linkages

CFD Simulation of a Scroll Compressor Oil Pumping System

Low Capacity Hermetic Type Compressor For Transcritical CO2 Applications

PREDICTION OF PISTON SLAP OF IC ENGINE USING FEA BY VARYING GAS PRESSURE

MARINE FOUR-STROKE DIESEL ENGINE CRANKSHAFT MAIN BEARING OIL FILM LUBRICATION CHARACTERISTIC ANALYSIS

Available online at ScienceDirect. Energy Procedia 110 (2017 )

Transient Modeling of Vapor Compression Refrigeration Systems Using Measured Compressor COP

Stepless Variable Capacity Control

Direct Torque Measurement of Hermetic Rotary Compressors Using Strain Gauge

Parameters Matching and Simulation on a Hybrid Power System for Electric Bulldozer Hong Wang 1, Qiang Song 2,, Feng-Chun SUN 3 and Pu Zeng 4

Noise Reduction in Bus A/C Systems with Screw Compressors Part II

A New Device to Measure Instantaneous Swept Volume of Reciprocating Machines/Compressors

Analysis and Development of a Turbivo Compressor for MVR Applications

Storage, Bulk Transfer, and In-Plant Handling of Zeotropic Refrigerant Blends

Performance Evaluation of Hermetic Refrigeration Compressor Using Torque Measurement Method

2013 THERMAL ENGINEERING-I

Transcription:

Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 24 Numerical Simulation and Performance Analysis of Rotary Vane Compressors for Automobile Air Conditioner Jian Hua Wu Xi'an Jiaotong University Li Zhang Xi'an Jiaotong University Lan Qing Huang Jianshe Automotive Air Conditioner Co. Yong Yu Tang Jianshe Automotive Air Conditioner Co. Follow this and additional works at: http://docs.lib.purdue.edu/icec Wu, Jian Hua; Zhang, Li; Huang, Lan Qing; and Tang, Yong Yu, "Numerical Simulation and Performance Analysis of Rotary Vane Compressors for Automobile Air Conditioner" (24). International Compressor Engineering Conference. Paper 1624. http://docs.lib.purdue.edu/icec/1624 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

C124, Page 1 NUMERICAL SIMULATION AND PERFORMANCE ANALYSIS OF ROTARY VANE COMPRESSORS FOR AUTOMOTIVE AIR CONDITIONER Jianhua Wu 1, Li Zhang 2,Lanqing Huang 3,Yongyu Tang 4 1 Associate Professor, 2 Graduate Student School of Energy and Power Engineering Xi an Jiaotong University, Xi'an 7149, P.R.China Tel: 86-29-8266439, E-Mail: jhwu@mail.xjtu.edu.cn 3 Senior Engnieer, 4 General Manager Jianshe Automotive Air Conditioner Co.,Ltd.,Chongqing City,, P.R.China ABSTRACT In order to improve the efficiency and reliability of the rotary vane compressors used in the automotive air conditioning systems, a comprehensive simulation model is developed. The simulated results are compared with measured data. The variation of pressure in compression chamber and clearance chamber at various rotational speeds and their effect are explained. The cooling capacity, power, COP, various efficiencies, loss and the reed vane behavior are analyzed. The effect of the change of pressure in papilionaceous oil chamber on compressor performance is discussed. This paper also presents some features of a rotary vane compressor for a CO 2 trans-critical cycle. INTRODUCTION The rotary vane compressor used for automotive air conditioner has many advantages, such as simple structure, smaller size, lighter weight, easier to start-up, rotating smoothly etc. But unfortunately there are some disadvantages in this kind of compressor. For example, at lower rotational speed, it has lower cool capacity; at higher rotational speed, it has higher frictional power losses. In order to improve the performance of the rotary vane compressor, a mathematical model of this kind of compressor is developed. In this paper, the control volume, energy equation, valve model, leakage model and dynamic model of vane and rotor are described. The pressure in compression chamber and clearance chamber at various speeds are explained, and the effect of refrigerant expanding in clearance chamber on compressor performance is described. The behavior of reed valve is discussed. The variations of the valve closing angle and velocity of valve impacting on valve seat are shown. The leakage, frictional loss, volumetric efficiency and mechanical efficiency at various speeds are discussed. The effect of the change of pressure in papilionaceous oil chamber on compressor performance is shown. The comparison of simulated results with measured data is given. Carbon dioxide (CO 2 ) is a natural refrigerant and is one candidate of alternatives to HFC refrigerants, so we also discuss the characteristics of a rotary vane compressor for a CO 2 trans-critical cycle using this mathematical model. Control volume MATHEMATICAL MODEL The first step to conduct a compressor simulation is to analyze the working process inside the compressor, to define control volume and to determine the mass exchange between the control volume and its surroundings. Figure 1 shows a schematic view of the rotary vane compressor. As the rotor rotates, the sliding vanes which locate in the slots of the rotor separate the space between rotor and cylinder into several compression chambers. The discharge port and slot transfer constitute the clearance chamber of a rotary vane compressor. When the leading vane of the compression chamber passes the discharge port, the pressure in the clearance chamber is significantly different from

C124, Page 2 that in the compression chamber since the internal compression ratio of a rotary vane compressor is lower. So the refrigerant in the leading chamber and clearance chamber quickly expand to the compression chamber. When the pressure in compression chamber is balanced with that in leading chamber and clearance chamber, the refrigerant in these chambers is compressed together. Considering the feature of rotary vane compressor above mentioned, in this time, the compression chamber, clearance chamber, leading chamber are respectively selected as a control volume. After the discharge process of the compression chamber begins, the pressure in clearance chamber is below that in the compression chamber due to the throttle at the entrance of discharge hole. The compression chamber is separated from the clearance chamber and is taken as a control volume alone. The clearance chamber is treated as a throttling element instead of a control volume, because the flow velocity through the discharge port is so large that the refrigerant kinetic energy is not negligible. And the mass flow rate discharged from the compressor chamber and the gas force acting on the valve is calculated directly by the pressure difference between the compression chamber and discharge plenum. For the above control volume, when the energy balance is studied, the internal energy of oil within the control volume is considered and the mass equation of oil is formulated correspondingly in order to accurately evaluate the heating effect of refrigerant and oil leaked on the refrigerant. However, the volume of oil is negligible. The mass equations and the energy equation are described in the reference [3]. Valve When the discharge valve of a vane rotary compressor opens, the reed valve wraps about its curved backer plate. The free length of reed valve varies with the valve displacement and thus the valve stiffness and effective mass always varies too. In this paper the valve system is treated as a one-freedom degree vibration system with variable stiffness and mass and its differential equation of motion is shown in reference [3]. Leakages In a rotary vane compressor, the leakage flow paths include the radial clearance between rotor and cylinder, rotor end face clearance, vane end face and side face clearance. The vane tip comes into full contact with the cylinder wall so there is no leakage across the vane tip. Figure 2 illustrates the leakage flow paths in this kind of compressor. For the radial clearance, leakage is assumed to be homogeneous oil-refrigerant mixture. The mass ratio of oil to refrigerant is proportional to that in the high pressure chamber. The velocity and mass rate of leakage flows is obtained by the Fanno flow equation. Meantime the indirect refrigerant leakage caused by solubility difference between high pressure chamber and low pressure chamber also is considered. Since the ratio of vane height to clearance height is greatly larger than one, the leakage flow through the vane end face clearance also is assumed as a Fanno flow of refrigerant containing a little oil. The leakage through vane side face clearance is refrigerant-dissolved oil, so it can be treated as a laminar flow of an incompressible Newtonian fluid, of course the indirect refrigerant leakage also is considered. The clearance between rotor end face and side plate also has a great effect on rotary vane compressor performance. In this case a gas leakage flow occurs from a high pressure gas chamber to a low pressure gas chamber which are divided by vanes, while an oil leakage flow occurs from a papilionaceous oil chamber which is located in the center of the side plate to a low pressure gas chambers. Free boundary lines are formed between the two leakages flow. In order to obtain the mass rate of leakage flow, a two-phase flow model is used to analyze this leakage flow. Dynamics The vane tip gas force has a great effect on vanes behavior especially during the discharge process. In order to accurately evaluate this gas force and the inertia force of vane, the closest point between vane tip and cylinder wall

C124, Page 3 is obtained. Before the point, the pressure at vane tip is the leading chamber pressure and after the point, which is the trailing chamber pressure. The papilionaceous oil chamber not only supply oil for the motion parts, but also can produce throttling effect during discharge process which increases the vane back pressure avoiding the vane tip detach from the cylinder wall. The continuity equation and Bernoul equation are used to obtain the vane back pressure. A constant frictional coefficient is used to estimate the vane side frictional forces and a frictional coefficient relationship [6] and a hydrodynamic lubrication model are used to estimate the vane tip frictional force. The pressure distribution on the vane side in the vane slot of the rotor is assumed to be linear from vane back pressure to chamber pressure. The forces acting on the vane, rotating torque and frictional losses at vane and bearing are calculated. In the dynamic analysis, the chamber pressure is calculated by solving the thermodynamic model equations. RESULTS AND DISCUSSIONS Table 1 shows the testing and calculation conditions for the rotary vane compressor. Table 2 shows the comparison of the cooling capacity values, shaft power and COP calculated by the above model with the measured data of a rotary vane compressor with a displacement of 96cc per rotation. The simulated results are consistent with the measured data quite well. Most deviations are less than 3%. Figure 3 shows the variation of pressure in compression chamber and clearance chamber with the rotational angle of rotor when the rotational speed is 2rpm. When the leading vane of compression chamber pass the discharge port of rotational angel about 168 degree, the pressure in clearance is about discharge pressure, while the pressure in compression chamber is about.56mpa since this time the internal compression ratio only reach 1.67, so the refrigerant in clearance chamber and leading chamber quickly expand to compression chamber. Correspondingly the pressure in clearance decreases quickly and the pressure in compression chamber increases quickly. From the P-V diagram, shown in Figure 4, it can be seen that this process of a rotary vane compressor has great effect on indicated power but has a little effect on cooling capacity because at this time the compression chamber has passed the suction port. This feature of the rotary vane compressor is different from the reciprocating piston compressor and other type compressors. Figure 5 shows the variation of volumetric efficiency with rotational speed. Figure 6 shows the variation of leakage loss, suction resistance, and suction heating with the rotational speed. With the rotational speed increases, the volumetric efficiency also increases, but the increasing becomes slowly at high rotational speed due to the suction resistance enhances. And the leakage loss is the main factor affecting the volumetric efficiency. The suction heating has a small effect on the volumetric efficiency and it will decrease slightly at high rotational speed. Figure 7 shows the variation of the cooling capacity loss caused by leakages with rotational speed. It can be seen that the leakage though the rotor radial clearance produces a significant impact on the cooling capacity, while the effect of the leakage through the rotor end face clearance is small as the clearance of tested compressor is small. Since the velocity of vane relative to slot becomes large at high rotational speed, the leakage through the clearance of vane side increases with rotational speed. As shown in Figure 8, the closing angle of reed valve becomes bigger at the high rotational speed and the velocity of the valve impacting on valve seat increases quickly with the rotational speed. Figure 9 shows the main frictional loss in the rotary vane compressor. The frictional loss at vane bottom and vane slot edge is directly proportional to the rotational speed basically. The loss at vane tip where mainly is in boundary frictional condition increases quickly with rotational speed especially at high rotational speed. The frictional loss of oil film resistance and bearing where mainly is in hydrodynamic lubrication condition is small, and they have the same amplitude. Figure 1 shows the variation of total frictional loss, suction and discharge loss. Figure 11 shows the variation of indicated efficiency and mechanical efficiency with rotational speed. The mechanical efficiency decreases slightly with rotational speed since the frictional loss at vane tip shown in Figure 9. The indicated efficiency falls at the high rotational speed due to the discharge loss shown in Figure 1.

C124, Page 4 Figure 12 shows the variation of the cooling capacity, shaft power and COP with the rotational speed. The cooling capacity is proportional to the rotational speed basically. The shaft power at the high speed is relatively large due to the frictional loss and discharge loss. The COP falls at the high rotational speed due to the increase of shaft power. From the above analysis, it can be seen that the mechanical efficiency of the rotary vane compressor is low. The main reason is that the contact force between vane tip and cylinder wall is large, correspondingly the frictional loss becomes large. Reducing the pressure in papilionaceous oil chamber is an effective method to improve the mechanical efficiency. Figure 13, and 14 show the variation of contact force between vane tip and cylinder wall when the pressure in papilionaceous oil chamber is 1.,.6 times of the discharge pressure respectively. With the pressure decreases, the contact force reduces quickly. When the papilionaceous oil chamber pressure is.6 times of the discharge pressure, the contact force becomes zero during discharge process. If the pressure in papilionaceous oil chamber continues to reduce, the leakage will appear between the vane tip and cylinder wall. Figure 15 shows the variation of mechanical efficiency and volumetric efficiency when the papilionaceous oil chamber pressure changes. It can be seen that when the papilionaceous oil chamber pressure is.6 times of the discharge pressure, the mechanical efficiency is improved more than 5% and the volumetric efficiency also is improved slightly since the leakage through rotate end face clearance and vane side face clearance decreases. Based on the mathematical model, we estimate the performance of a rotary vane compressor for a CO 2 trans-critical cycle. The displacement of the CO 2 compressor is 13.5cc, and its suction and discharge port area are assumed to be 1/4 of the R134a compressor, correspondingly the clearances also are reduced. The calculating conditions are shown in Table 1. Figure 16 shows the volumetric efficiency versus rotational speed. The volumetric efficiency increases with rotational speed, since the leakage loss becomes small at high rotational speed while the suction resistance loss is small even at high rotational speed. This feature can make CO 2 compressor run at high rotational speed with high volumetric efficiency. When the number of vanes increases, the volumetric efficiency can be improved obviously, since the pressure difference of two adjacent compression chambers falls, shown in Figure 17. For a CO 2 compressor, the moment per unit length acting on vane side out of the rotor slot caused by gas force of two adjacent compression chambers is a main factor affecting the compressor reliability. By increasing the number of vanes, this moment can be decreased obviously, shown in Figure 18. The maximum value of this moment at a 7 vanes CO 2 compressor is about 2 times of the R134a compressor, if the material of vanes is replaced by alloyed steel at a CO 2 compressor, the strength of vanes should be sufficient. CONCLUSIONS A comprehensive simulation model of a rotary vane compressor is developed. The simulated results agree well with the measured data for the rotary vane compressor. The variation of the pressure in compression chamber and clearance chamber with the rotational speed are discussed. The valve behavior with the rotational speed is also discussed. The velocity of valve impacting on valve seat rises quickly with the rotational speed. The leakage loss is the dominant factor influence the cooling capacity of the rotary vane compressor. The frictional loss between vane tip and cylinder wall is the main factor affecting the mechanical efficiency. Reducing the pressure in papilionaceous oil chamber can obviously improve the mechanical efficiency, further more the volumetric efficiency also will increase slightly. For a rotary vane compressor for a CO 2 trans-critical cycle, increasing the number of vanes can obviously improve the volumetric efficiency and decrease the moment per unit length acting on vane side out of rotor slot. REFERENCES 1. S.Takeshika. Simulation and Modeling of an A/C Rotary Vane Compressor. SAE, 97116. 2. Fukuta M, Yanagisawa T. Mathematical Model of Vane Compressors for Computer Simulation of Automotive Air Conditioning Cycle. JSME (B), 1995, Vol.38, No.2.

3. Wu J, Study on Performance and Dynamic of Inverter Controlled Rotary Compressors, 2 ICECP. C124, Page 5 4. Hagomoto, K., et al. Analysis of Two-phase Flow in the Narrow Clearance Between a Rotor End Face and a Stationary Plate. Mitsubishi Heavy Industries Tech Report (in Japanese), 1986-3, Vol.23, No.2. 5. Fukuta M, Yanagisawa T, Shimizu T. Analysis of Leakage Flow Through Clearance on Rotor Face in Vane Compressors. 1992, ICECP. 6. Kamiya H, Takashi Shimizu T. Frictional Loss on Vanes in Through-vane Compressors. JSME, 93-191. 7. Howard H. Platts. Hydrodynamic Lubrication of Sliding Vanes. 1976, ICECP. 8. A. Picksak and H. Kruse. Mathematical Simulation of Lubrication Conditions in Rotary Vane Compressors. 1986, ICECP. 9. Fukuta M and Radermacher R. Performance of Vane Compressor for CO 2 Cycle. ICECP, Natural Working Fluid at Purdue, 2. Table 1 the testing or calculating conditions Refrigerant Suction pressure Superheat Discharge pressure Subcooling R134a.3Mpa 1 1.57Mpa 5 CO 2 3.48Mpa 1 1.Mpa Table 2 Comparison between the calculated results and the measured data Speed Capacity (w) Power (w) COP (Rpm) Measured Calculated Measured Calculated Measured Calculated 1 237.6 231.9 1122.7 1112. 2.6 2.7 2 4816.9 4849.7 2221.5 2213.4 2.17 2.19 3 725.5 7346.8 3434.1 3423. 2.11 2.15 Fig.1 Sectional view of compressor Fig.2 leakage flow paths

C124, Page 6 1.8 1.8 Pressure in chambers(mpa) 1.6 1.4 1.2 1..8.6 Pressure(Mpa) 1.6 1.4 1.2 1..8.6.4.2 Compression Clearance.4.2 3 6 9 12 15 18 21 24 27 Angle of rotor(degree) Fig.3 Pressure in working chambers at 2rpm 2 4 6 8 1 Volume(cm 3 ) Fig.4 P-V diagram at 2rpm Volume efficiency(%) 82 81 8 79 78 Relative cooling capacity Loss(%) 2 15 1 5 leakage suction heating suction resistance 77 Rotational Speed(rpm) Fig.5 Volumetric efficiency of compressor Fig.6 Cooling capacity loss 15 24 Relative cooling capacity loss(%) 1 5 rotor radial vane end face vane side face rotor end face Closing angle(degree) 238 236 closing angele impacting velocity 2 Impacting velocity(m/s) Fig.7 The leakage losses Fig.8 Closing angle and impacting velocity Frictional loss(w) 5 4 3 2 bearing oil film vane bottom vane slot edge vane tip Power Loss(W) 7 6 5 4 3 2 frictional loss suction and discharge loss 1 1 Fig.9 Main friction losses Fig.1 Frictional loss and discharge loss

C124, Page 7 82 8 Efficiency(%) 8 78 76 74 72 7 mechanical efficiency volume efficiency Cooling capacity, power (KW), COP 7 6 5 4 3 2 1 cooling capacity shaft power COP Fig.11 Volume and mechanical efficiency Fig.12 Cooling capacity power and COP 24 16 22 14 Contact force(n) 2 18 16 14 12 1 1rpm 2rpm 3rpm Contact force(n) 12 1 8 6 4 2 1rpm 2rpm 3rpm 3 6 9 12 15 18 Angle of rotor(degree) 3 6 9 12 15 18 Angle of rotor(degree) Fig.13 The contact force at 1. times p d Fig.14 The contact force at.6 times p d 81.36 1 81.34 volume efficiency mechanical efficiency 86 9 Volume efficiency(%) 81.32 81.3 81.28 84 82 Mechanical efficiency(%) Volumetric efficiency(%) 8 7 6 5 vanes 7 vanes 81.26 8.6.7.8.9 1. The ratio of back pressure to discharge pressure Fig.15 Volumetric and mechanical efficiency 5 Fig.16Volumetric efficiency of CO 2 compressor 5 Pressure(Mpa) 11 1 9 8 7 6 5 5 vanes 7 vanes leading chamber compression chamber Moment of force (N.m/m) 4 3 2 1 5 vanes R134a 5 vanes CO 2 7 vanes CO 2 4 3 3 6 9 12 15 18 Angle of rotor(deg) Fig.17 Chambers pressure of CO 2 compressor 3 6 9 12 15 18 Angle of rotor(deg) Fig.18 The vane side moment of CO 2 compressor