Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

Similar documents
Venturi Flow Meter Installation and Operation Manual

Installation, Operation, and Maintenance Manual

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual

IMO-200EN 09/2010. Trunnion mounted forged ball valves Model FF and GG. Installation, Maintenance and Operating Instructions IMO-200EN 09/2010

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

V500 and V510 VERIS Verabar Installation and Maintenance Manual

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions. Please read these instructions carefully

COMMERCIAL. BV & BVM Series Installation Instructions 06/29/15

V150 VERIS Verabar Installation and Maintenance Manual

CUSTOM COMBINATION AIR VALVE

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

KEYSTONE OPTISEAL F14/16-15/17 AND BREWSEAL BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Butterfly valves Figure 56 Installation & Maintenance Instructions

INSTALLATION & MAINTENANCE MODEL mm

Y690A Series Pressure Reducing Regulators

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

Type MR105 Direct-Operated Pressure Reducing Regulators

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL

Type MR108 Direct-Operated Backpressure Regulator

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

GL Ludemann Y-Strainers

IFOA Integral Flow Orifice Assembly

Purging Air From Divider Block Lubrication Systems

Installation Instructions

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

Type 289P Pilot-Operated Relief Valve

Installation, Operation and Maintenance Manual. TOM WHEATLEY Piston Check Valve TOM WHEATLEY

Val-Matic 3-Way Tapered Plug Valve

582 Series. Instruction Manual. Two-Door Wafer Check Valve N-582 (R-08/2016)

KEYSTONE SERIES GRF RESILIENT SEATED BUTTERFLY VALVES INSTALLATION AND OPERATION MANUAL

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

IOM Manual. IOM Manual. Series 76/77.

INSTALLATION - MAINTENANCE MANUAL Severe Service Series M4 Ball Valve

Fisher V250 Ball Valve

DEMCO Resilient-Seated Butterfly Valve

Type 289P Pilot-Operated Relief Valve

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES

Type 644 and 645 Differential Pressure Pump Governors

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

Industrial Turbo Meters, Sizes 2" through 6"

289 Series Relief Valves

Installation Instructions

TITAN FLOW CONTROL, INC.

EZH and EZHSO Series. Pressure Reducing Regulators. EZH and EZHSO Series. Introduction. Scope of the Manual. Product Description !

FPD201 Single-chamber orifice fitting

740G Double Disc Check. Valve. Operation / Maintenance Manual. General Information 2. Installation/Operation 3

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

Installation, Operation, and Maintenance Manual

161 Series Pilots for Pilot-Operated Pressure Reducing Regulators

CIRCLE SEAL CONTROLS

2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

INSTALLATION, OPERATION AND MAINTENANCE Threaded and Wafer Style Flowmeters

MAINTENANCE MANUAL. Covering Models: Series (1/4-10 ) S Series (1/4-1 ) Series (3-10 )

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

METERING VALVE 2" STEM GUIDED

TITAN FLOW CONTROL, INC.

Pilot-Operated Regulators

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

Flow Control Valve IOM 770-U

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

Type 92S Pilot-Operated Steam Regulators

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

Refrigerating Specialties Division 1. BULLETIN DN23-05B Type A4A-DN, A4AK-DN, A4AE-DN, A4AR-DN. January 2007 Installation and Service Information

type 122a three-way Switching Valve

BLACKMER BYPASS VALVES

Fisher RSS Lined Globe Valve

CLIF MOCK TM. Model 5030 Orifice Fitting. User Manual. Manual No , Rev. B

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

Fisher RSS Lined Globe Valve

Wafer and Globe Style Silent Check Valve. Operation, Maintenance and Installation Manual

TYPE E Main Valve Sizes 3 /8 through 12

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

1/2" AIR DRIVEN DIAPHRAGM PUMP

KP-C Series. Close Coupled End Suction Centrifugal Pumps. Installation, Operation and Maintenance

Installation Operation Maintenance

GT-200 GATE VALVES PN16, Screwed end

Fisher D2T FloPro Control Valve

720A Wafer & 821A Globe Style

CIRCLE SEAL CONTROLS

DEMCO DEMCO RESILIENT SEATED BUTTERFLY VALVE. Installation, Operation and Maintenance Manual D I S T R I B U T E D V A L V E S DEM-RSBV-IOM

T205VB Series Tank Blanketing Vacuum Breakers

Fisher 644 and 645 Differential Pressure Pump Governors

Flow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300)

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Fisher TBX Hydro Plug Fixture

INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION

Series 820 AWWA Butterfly Valves

Type EZR Relief Valve or Backpressure Regulator

Constant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Installation Instructions

Rosemount 485 Annubar Flanged Assembly

Transcription:

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual 354-EN Please read and save these instructions.

Installation Procedures Orifice Flange Union Assembly Installing Orifice Plate: 1. Remove all components from shipping container 2. Install studs in lower half of orifice flanges 3. Place orifice plate and gaskets between flanges ( INLET text faced upstream and if bore is beveled, bevel must face downstream.) 4. Orifice bore must be centered within 3% of inside pipe diameter 5. Install remaining studs around orifice flanges with one nut on each end 6. Inside diameter of gaskets must not protrude beyond inside surface of pipe 7. Orifice plate must be installed flat without distortion 8. Tighten flange bolts evenly to prevent plate buckling 9. Tighten all studs 10. On orifice flanges other than weld neck or corner tap, pressure tap holes must be drilled through the pipe. Holes must be free of burrs or other irregularities. 11. Gas flow taps and liquid taps should be horizontal (on sides) 2 Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com/emech for up-to-date information.

Installation Procedures - continued Orifice Flange Union Assembly Caution: - This is a high quality flow metering assembly. If improperly installed, it must be reinstalled. If damaged, it must be replaced. - For liquid flow and gas flow, assembly should be installed with nameplate on top (0 degrees). High pressure taps and low pressure taps should be horizontal (at 90 degrees and 180 degrees). - Install assembly in pipeline so that the Flow Directional Arrow is orientated in the direction of fluid flow and Inlet stamped on the orifice plate faces towards inlet flange. - Assembly should be handled from the outside only. Do not damage inside. - Flanges must be parallel and properly aligned to prevent cracking. - Center assembly carefully in pipe. - Gaskets must be properly placed and centered on flange bolt circles. Gaskets must not protrude into the flow! Failure to install gaskets properly may adversely affect the accuracy of the meter. - Do not use assembly as a pipe support. Support pipes on either side of assembly. - Do not over torque bolts. - Provide necessary clearances as deemed practical for installation, inspection and maintenance. - See Orifice Flange Union Assembly drawing for more information. Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com/emech for up-to-date information. 3

Start-Up Procedures Determine that the orifice flange union is properly installed. The orifice flange union is a piping component and should be handled accordingly with the same precautions. DO NOT HANDLE ORIFICE FLANGE UNION ASSEMBLY FROM ITS INSIDE. Determine that the pressure connections are properly made and are appropriate for the intended service. Determine that the orifice flange union assembly has been installed in strict conformance with the Installation Directions included in this manual. Do not over-pressurize orifice flange union assembly. Refer to approval drawing for design pressure. Do not subject orifice flange union assembly to shock pressures or water hammer. When filling pipe line, bleed-off air in the proper fashion. Determine that pressure piping to secondary instrumentation is installed correctly. If the orifice flange union appears damaged in any way, contact Armstrong. Shut-Down Procedures If it is necessary to isolate the differential pressure signal from the secondary instrumentation, close the isolation valves (if provided) and disconnect impulse piping. If secondary instrumentation is to be disconnected for an extended period, use pipe plugs appropriate for the line pressure. If the orifice flange union assembly is to be removed from the line for any reason, depressurize and drain the pipe line. Move assembly with slings or strapping appropriate for the weight and geometry of the assembly. 4 Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com/emech for up-to-date information.

Preventive Maintenance 1. Check Flange and Pressure Tap Connections for Leaks 2. Inspect Exterior Finish for Scrapes, Dings, or Blistering Annually Annually By Instrumentation Operator or Mechanical Personnel By Instrumentation Operator or Mechanical Personnel No special tools or skills are necessary for preventive maintenance tasking. No preventive maintenance parts list applicable. Corrective Maintenance In case of loss-of-signal or erratic output, check taps and impulse piping to secondary instrumentation for blockage or debris. Check impulse piping for leaks, trapped condensation (in the case of compressible gas flow), or trapped air (in the case of liquid flow.) In case of blockage, purge lines with air or water (as is appropriate) pressurized to approximately 30 PSI above line pressure. WARNING: IN NO CASE SHOULD FLUSHING PRESSURE EXCEED THE DESIGN PRESSURE OF THE PROCESS OR IMPULSE PIPING. In case of trapped condensate or trapped air, remove by use of bleed valves or plugs, or through the manifold at the flow transmitter. Stop leaks by tightening, resealing, or re-gasketing as necessary. Touch-up exterior finish with the same or a compatible coating system as necessary. There are no test points, adjustments, or user-serviceable parts in the orifice flange union, nor is there any assembly or disassembly. If problems persist, contact Armstrong. Corrective maintenance can be performed by mechanical or plant personnel. No special tools are required for corrective maintenance. Spare Parts The orifice flange union assemblies provided on this project were designed and manufactured specifically for this project. The orifice flange union assembly has no moving or parts. There is no parts list and there is no recommended stocking level. Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com/emech for up-to-date information. 5

Safety Prior to Start-Up: Determine that the orifice flange union assembly is properly installed. The orifice flange union assembly is a piping component and should be handled accordingly with the same precautions. DO NOT HANDLE ORIFICE FLANGE UNION ASSEMBLY FROM ITS INSIDE. Determine that the pressure connections are properly made and are appropriate for the intended service. Determine that the orifice flange union assembly has been installed in strict conformance with the Installation Directions included in this manual. If the flanges or plate appear damaged in any way, contact Armstrong. At the Start-up and After Start-Up: Do not over-pressurize the orifice flange union assembly. Refer to approval drawing for design pressure. Do not subject orifice flange union assembly to shock pressures or water hammer. When filling pipe line, bleed-off air in the proper fashion. Conform to Preventive Maintenance procedures included in this manual. Proper venting and draining is required in pipeline. A pressure relieving device not exceeding 110% MAP should be installed and functional in pipeline. All operational loading is not covered by orifice flange union assembly manufacturer. This would be the responsibility of the owner/user unless noted at time of purchase order and included in approved submittal. 6 Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com/emech for up-to-date information.

Storage Requirements Orifice Flange Union Assembly Indoor Storage: The orifice flange union assembly can be stored indefinitely indoors in a clean, non-corrosive environment. If environment is not clean, meters must be covered. Store orifice flanges and plate away from high traffic areas in order to minimize damage risk. Orifice flanges, orifice plates or assemblies must not be stacked. Orifice flanges may have bare iron or steel flange faces, or lightly primed flange faces as required by the specification. If flanges will be stored in humid or corrosive areas, the flange faces may need to be coated with a suitable rust preventative. Note that any coating or sealant may need to be removed prior to installation; refer to the specification and applicable standards or codes. Prolonged exposure to sunlight or other ultraviolet sources (fluorescent lights, etc.) may discolor, degloss, or chalk the exterior finish, if painted. Temperature and humidity fluctuations should be minimized. If storage is to be long-term, it is recommended that flanges and plates be covered with a tarp or heavy plastic sheeting. Temperature and humidity fluctuations must be minimzed. Outdoor Storage Short Term (less than 3 months): Store away from high traffic areas in order to minimize damage risk. Flanges and plates, or assemblies must not be stacked. If flanges, plates or assemblies will be stored in humid or corrosive areas, the flange faces may need to be coated with a suitable rust preventative appropriate for outdoor exposure. Note that any coating or sealant may need to be removed prior to installation; refer to the specification and applicable standards or codes. The ends are capped to eliminate foreign matter from damaging the internal portions of the meter. These caps must not be removed until installation. The pressure sensing tap connections have pipe plugs to eliminate the possibility of clogging. These caps must not be removed until installation. If the exterior finish gets damaged, it must be touched-up with the same or a compatible coating system. Note that prolonged exposure to sunlight may discolor, de-gloss, or chalk exterior finish. It is recommended that the flanges and plate be covered with a tarp or heavy plastic sheeting. Assembly should not be stored outdoors for long term storage. See Indoor Storage for long term storage requirements. Orifice Flange Union Assembly Transport: Depending on unit and order size, the orifice flanges are strapped or lagged onto pallets or custom skids. Using the skids, the meters can be moved by a forklift of adequate capacity. DO NOT DRIVE THE FORK THROUGH THE FLANGE CAPS OR INTO THE FLANGE INTERIOR. The flanges can be lifted by a crane or forklift in conjunction with an appropriate sling. Avoid scraping or scratching the coated surfaces. Touch-up coatings as needed. Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com/emech for up-to-date information. 7

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com for up-to-date information. Armstrong International North America Latin America India Europe / Middle East / Africa China Pacific Rim armstronginternational.com 354-EN 11-9-2016 2016 Armstrong International, Inc.