BFMM DC4A SBF /2-2 Double Check Valve (DC) Backflow Preventer. Model DC4A Model DCLF4A

Similar documents
BFMM DC4A SBF EFFECTIVE AUGUST 1, 2016

TABLE OF CONTENTS. A110 Series Differential... 9 Pressure Reducing Valve...4-5

butterfly valves Quality, Service A history of and Innovation

Quality, Service. A history of. and Innovation

2 ½ 12. Installation, Operation, and Maintenance Manual. Reduced Pressure Principle Backflow Preventer. Reduced Pressure Detector Assembly

2 ½ 12. Model RP 4A Model RPDA 4A Model RPDA2 4A. Installation, Operation, and Maintenance Manual

MAINTENANCE MANUAL. Covering Models: Series (1/4-10 ) S Series (1/4-1 ) Series (3-10 )

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

JOB LOSSES BY STATE, State Industry US total AK AL AR AZ CA CO CT Agriculture, forestry, fisheries -15, ,

DC-501 Double Check Backflow Preventer OPERATIONS, MAINTENANCE AND TROUBLESHOOTING GUIDE

2013 Migration Patterns traffic flow by state/province

2016 Migration Patterns traffic flow by state/province

INSTALLATION & MAINTENANCE MODEL mm

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

THIS WARRANTY IS IN LIEU

Choose a Sunroof with Style STRUCTURE PLUS. Webasto Aftermarket Sunroofs OE Quality. Featuring

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

FY 2002 AWA INSPECTIONS

Series 867 Reduced Pressure Zone Assemblies

National Routing Number Administration p-ani Activity and Projected Exhaust Report

Colt Series C400, C500

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

All Applicants - By HS GPA Run Date: Thursday, September 06, Applicants GPA Count % of Total

Digital Print-out Test Kit for Backflow Preventer Assemblies

Maintenance Manual Double Check and Double Check Detector Assemblies Series 850, 856, 870V & 876V 2 1 /2" - 10" (65 250mm)

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

IMO -272 ISSUE 6/95 SERIES MBV, METAL-SEATED FLANGED BALL VALVES 3", 4" AND 6" CLASS 150 AND 300 STANDARD BORE, MB AND MC

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

4 - Way Control 4 - Way Control 4 - Way Control with lock

Adjustable Differential Relay A1

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Installation Service Repair Kits Maintenance RP/IS-774/774DCDA/774X/774XDCDA

U.S. Heat Pump Water Heater Market Transformation: Where We ve Been and Where to Go Next

Cash-Flo. Operation & Maintenance Manual. BackFLOW PREVENTERS. A Division of the Reliance Worldwide Corporation

DIMENSIONS (approximate)

EP 724 US RAIL SERVICE ISSUES DATA COLLECTION

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

I & M Mark 708. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & 14M Actuator and Motor Valve

Hydraulic Motors Repair Instructions

Alaska (AK) Passenger vehicles, motorcycles 1959 and newer require a title ATV s, boats and snowmobiles do not require a title

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Reducing deaths, injuries, and loss from motor vehicle crashes

EPA REGULATORY UPDATE PEI Convention at the NACS Show October 8, 2018 Las Vegas, NV

Technical Manual MSI Dart Check Valve

Five Star Dealer INTERNATIONAL.

Five Star Dealer USA.

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

UPDATE OF THE SURVEY OF SULFUR LEVELS IN COMMERCIAL JET FUEL. Final Report. November 2012

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

Green Bus Technology Plan

SERVICE INSTRUCTIONS D TON

EPA Emissions Standards for Switch and Line-Haul Locomotives

BAF Overview. Barry P. Carr Northeast Regional Sales Manager November 2012

NEECO INDUSTRIES INC. INSTRUCTION MANUAL 7 1/16 10K SLAB GATE BODY

Product Manual. S&S V-100 Ball Valves 2 though 8 Inch Designs. Introduction: Installation:

Installation, Maintenance, & Repair Series 919 and LF919

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Series 007. Double Check Valve Assembly. Installation Service Repair Kits Maintenance. Sizes: 1 2" 3" Watts 3 4" 007M3QT RP/IS-007

Semiannual Report Of UST Performance Measures End Of Fiscal Year 2018 (October 1, 2017 September 30, 2018)

CUSTOM COMBINATION AIR VALVE

Product Manual. CVS V-100 Ball Valves 2 though 8 Inch Designs. Introduction: Installation:

DEMCO Resilient Seated Butterfly Valve

TYPE E Main Valve Sizes 3 /8 through 12

DRUG-IMPAIRED DRIVING CHARGES: CANADA, August 10, 2015

SINGLE ACTING ALTITUDE VALVE

1450 Control Valve. General Instructions. Table of Contents

Transport trucks and trailers

Purging Air From Divider Block Lubrication Systems

Diesel Generators in the Data Center: When to Go Big

Double Check Backflow Preventer 314" to 2"

An Overview of Solar Energy and Opportunities for Growth in the Midwest and Kansas

AMERICAN MOBILE POWER VOL.10

PlugShare Quarterly 2015-Q3 Census, US Electric Vehicle Infrastructure Exhibits

UL 1008 ATS Withstand and Close On Ratings

VALVES API 6A Compact Ball Valves

THE LF-690 SERIES. Operating and Service Manual. Series includes all variants of LF-690/691 and 692

CENTRO-MATIC PUMP, MODELS 84050, & 85460

OPERATING AND MAINTENANCE MANUAL

OPERATION AND PARTS MANUAL

Installation, Operation & Maintenance Instructions

PEB & PESB Valve Installation and Operating Instructions Troubleshooting Guide

Val-Matic 3"-24" Butterfly Valve With LSA Actuator and External Stops

Series 990/990RPDA. Reduced Pressure Zone Backflow Preventer. Sizes: 4", 6", 8" (100mm, 150mm, 200mm)

CROSS-CONNECTION CONTROL MANUAL

2/22/2017. Cost!! It s an investment! Take Care of It! TEST KIT: INSTRUMENT SPECIALTIES INC ST. JOHNS PKWY. SANFORD, FL

Owner letters will be mailed based upon part number and production date, starting with earlier production vehicles.

Policy considerations for driving automation technology

EURO BEAD BREAKER MODEL # Instruction Manual Parts Breakdown

IMO-200EN 09/2010. Trunnion mounted forged ball valves Model FF and GG. Installation, Maintenance and Operating Instructions IMO-200EN 09/2010

Backflow Irrigation Control Station BIC-1000

BACKFLOW PREVENTION CATALOG

Series 100 Slam Shut Valve

Backflow Preventers TABLE OF CONTENTS

Thru-The-Wall TTWC-R Series Condensing Unit Catalog 1-1/2 To 2-1/2 Ton Capacity

Installation & Maintenance Manual SPRING ENGAGED FRICTION CLUTCHES THROUGH SHAFT MOUNT - BALL BEARING PILOT REGULAR DUTY

SLOW DOWN AND MOVE OVER

Transcription:

BFMM DC4A SBF 1-2012 1/2-2 Double Check Valve (DC) Backflow Preventer Model DC4A Model DCLF4A

INSTALLATION, OPERATION, & MAINTENANCE MANUAL TABLE OF CONTENTS Double Check Valve Backflow Preventer 1/2 2 Section Page I Description and Operation...3 II Installation...3 III Trouble Shooting Guide...5 IV Maintenance Instructions...5 V Testing Procedures....6-7 Parts List Parts List (1/2-2 )... 8-10 Repair Kits Repair Kits (1/2-2 )... 11 2 www.apollovalves.com Customer Service (704) 841-6000

BFMM DC4A SBF DOUBLE CHECK VALVE BACKFLOW PREVENTER 1/2 2 I. DESCRIPTION AND OPERATION The Double Check Valve (DC) device consists of two independently-acting, spring-loaded check valves. Two resilient seated shutoff valves and four test cocks complete the assembly. Each check is designed to maintain a minimum of 1 psi across the valve during normal operation. If at any time the pressure downstream of the device increases above the supply pressure, both check valves will close to prevent any backflow from occurring. The flowing and no flow conditions are illustrated in figures 1 and 2. To initiate flow, supply pressure must be sufficient to open both checks and overcome friction, normally a minimum of 3 to 5 psi above the downstream pressure. II. INSTALLATION A. The DC must be installed in an accessible location to facilitate periodic field testing and maintenance. B. Flush all upstream piping thoroughly to remove foreign matter prior to installing the device. C. The device should be installed either horizontally or vertical up for ease of maintenance and testing. A clearance between the lower most portion of the device and flood grade or floor should be provided for ease of maintenance. D. When shut-off valves are provided separately, they should be installed with a test cock on the upstream side of the inlet shutoff valve. E. After installing the assembly and with downstream or #2 shut-off valve closed, pressurize the device and bleed ALL air through test cock #4. Then open #2 shut-off valve. Customer Service (704) 841-6000 www.apollovalves.com 3

INSTALLATION, OPERATION, & MAINTENANCE MANUAL Figure 1 (FLOWING CONDITION) Figure 2 (NO FLOW CONDITION) NOTE: Pressures shown are for illustrative purposes only and are not necessarily indicative of any actual valve. 4 www.apollovalves.com Customer Service (704) 841-6000

BFMM DC4A SBF III. TROUBLE SHOOTING SYMPTOM CAUSE CORRECTIVE ACTION 1. Check valve fails to hold a. Shut-off valve not closed 1 psid. completely. b. Check valve fouled with debris. c. Check poppet stem not moving freely in guide. a. Close #2 shut-off valve or inspect for possible through leakage. b. Inspect and clean seat disc and seat. c. Inspect for debris or deposit on poppet stem or guide. IV. MAINTENANCE INSTRUCTIONS 1/2 2 A. Disassembly - Check Valves 1. Close #2 shut-off valve, then close #1 shut-off valve. 2. Bleed pressure from the assembly by opening #2, #3, and #4 test cocks. 3. Unscrew cap using hex head provided. 4. Push down and turn the spring retainer 90 degrees to remove. Remove the spring. Remove the poppet from the check seat. 5. Normally, the check seat need not be removed. If removal is required, rock it back and forth while pulling outward. B. Disassembly - Check Valve Poppet CAUTION: Do not use pliers or other tools, which may damage or scratch the plastic stem. 1. Holding the poppet assembly in one hand, remove screw and retaining washer. 2. Remove the seat disc. 3. All parts should be carefully inspected for any damage or excessive wear and thoroughly rinsed in clean water prior to reassembly. Replace worn parts as necessary. C. Assembly - Check Valve Poppet 1. Install new disc in poppet and secure with washer and screw. D. Assembly - Check Valve 1. If the check seat was removed, install the new o-ring and lubricate with a thin coat of Apollo supplied lubricant, DOW 111 or equal. Line up the seat with the bore and push it firmly into place. 2. Place and center the poppet assembly in the check seat. 3. Install the spring onto the poppet. 4. Install the spring retainer onto the spring by pushing down into the grooves of the check seat and turning 90 degrees. Ensure spring retainer pops up about.1 and locks into the lugs. CAUTION: Ensure the spring retainer orientation matches that in the parts list drawing or the device s flow will be significantly restricted. 5. Apply a thin coat of Apollo supplied lubricant, DOW 111 or equal on cap o-ring. 6. Install cap. Customer Service (704) 841-6000 www.apollovalves.com 5

INSTALLATION, OPERATION, & MAINTENANCE MANUAL V. TESTING PROCEDURES This test is performed with the Differential Pressure Gauge Test Kit. The Differential Pressure Gauge simply measures the pressure drop across the check valve. This pressure drop is normally the same as the strength of the check valve spring. In using the Differential Pressure Gauge to test the Double Check assembly, a minimum of 1.0 psid is required for each check valve in order for that check valve to pass the test. Such a small reading is often difficult to read on most test kits. This is one of the drawbacks of this test. However, since the first shut-off valve is left in the open position for this test, it is possible to use this test when the first shut-off valve is leaking badly. NOTE: This is a three-valve test kit procedure and may or may not be approved in all jurisdictions. Consult your local water purveyor for acceptable test procedures. Test Setup 1. Notify customer that the water service will be off. Identify the make, model, and serial number on the backflow device. Inspect that this is an approved assembly - two check valves, two shut-off valves and four test cocks. Observe the area to make sure there are no leaks. 2. Flush test cocks (1, 2, 3 & 4), then close all test cocks. 3. Install appropriate adapters (if necessary). 4. Close shut-off valve #2. TEST NO. 1 PURPOSE: To test check valve #1 1. Close all valves on test kit. 2. Connect the high side hose to test cock #2 and the low side hose to test cock #3. Open test cock #2 and test cock #3. 3. Open vent valve C and high A on the test kit to bleed air from the high side of the kit. Close high A valve and then open low B valve to bleed the low side. Close low B valve. 4. Record the gauge reading. It must be a minimum of 1.0 psid in order to pass. Close test cock #2 and test cock #3. TEST NO. 2 PURPOSE: To test check valve #2 1. Move the high side hose to test cock #3 and the low side hose to test cock #4. Open test cock #3 and test cock #4. 2. Open vent C valve. Then open high A and bleed air from the high side of the kit. Close high A valve, and then open low B valve and bleed the low side of the kit. Close low B valve. 3. Record the gauge reading. It must be a minimum of 1.0 psid in order to pass. Close test cock #3 and test cock #4. Remove hoses and test kit. Slowly open shut-off valve #2 in order to restore water flow to the facility, placing the DC back into service. 6 www.apollovalves.com Customer Service (704) 841-6000

BFMM DC4A SBF TEST NO. 3 PURPOSE: To test leaking #2 shut-off valve As previously mentioned, the above test is not accurate when the second shut-off valve is leaking. The following test will expose a leaking shut-off valve. 1. Both shut-off valves should be open. Make sure all valves on test kit are closed. Connect the high A hose to test cock #2 and the low B hose to test cock #3. Open test cock #2 and test cock #3. 2. Open the high A valve and vent C valve to bleed air from high side of gauge. Open low B valve to bleed air from low side of gauge. Close valves A, B and C on test kit. 3. Connect the vent hose to test cock #4. Open test cock #4. 4. Close shut-off valve #2. The differential gauge needle should read at least 1.0 psid in order to pass. 5. Open the high A valve and vent C valve. This will put back pressure on check valve #2. 6. Close test cock #2. NOTE: If gauge is steady, then shut-off valve #2 is holding tight. However, if gauge drops to zero psid, then shut-off valve #2 is leaking. NOTE: If the gauge rises then the #2 shut-off valve is still leaking, but is under backpressure from the facility. Figure 3 Customer Service (704) 841-6000 www.apollovalves.com 7

PARTS LIST 1/2 2 INSTALLATION, OPERATION, & MAINTENANCE MANUAL Figure 4 8 www.apollovalves.com Customer Service (704) 841-6000

BFMM DC4A SBF Item # Description Std. or LF DC4A and DCLF4A Parts List Qty. Part Number 1/2 3/4 1 1-1/4 1-1/2 2 1 Body All 1 Consult Factory 2 Label Plate All 1 Consult Factory 3 Label Plate Tacks All 2 I-2614-00 Test Cock M x F (81 metal) Std 78-290-01 (Optional) 78-291-01 (Standard) 4 Test Cock M x F (Lead Free) LF 78LF-290-01 (Optional) 78LF-291-01 (Standard) 4 Test Cock SAE (81 metal) Std 78-292-01 (Standard) 78-293-01 (Optional) 4a Test Cock SAE (Lead Free) LF 78LF-292-01 (Standard) 78LF-293-01 (Optional) 5 Cap (81 metal) Std F-3846-05 F-3822-05 F-3848-05 F-3850-05 F-3854-05 2 Cap (Lead Free) LF F-3847-05 F-3823-05 F-3849-05 F-3851-05 F-3855-05 6 Cap O-Ring All 2 D-4881-00 D-4812-00 D-4884-00 D-4885-00 D-4888-00 7 Check Module O-Ring All 2 D-4880-00 D-4744-00 D-4882-00 D-4884-00 D-4885-00 8 Check S-Assy (see below) All 2 W-9075-05 W-9003-05 W-9074-05 W-9159-05 W-9204-05 Individual parts are only available for bulk sales. Please refer to the appropriate repair kits on pages 11. Item # Description Std. or LF Check Module Sub-Assembly Parts LIst Qty. Part Number 1/2 3/4 1 1-1/4 1-1/2 2 9 Check Seat All 1 L-7815-00 L-7727-00 L-7813-00 L-7979-00 L-7983-00 10 Screw All 1 B-3279-00 B-1750-00 11 Disc Retaining Washer All 1 E-2372-00 E-2841-00 E-2933-00 E-2860-00 E-2876-00 12 Seat Disc All 1 D-4771-00 D-4743-00 D-4770-00 D-4853-00 D-4873-00 13 Poppet All 1 K-4491-00 K-4471-00 K-4483-00 K-4511-00 K-4512-00 14 Spring All 1 A-2505-00 A-2503-00 A-2510-00 A-2511-00 A-2512-00 15 Spring Retainer All 1 L-7814-00 L-7726-00 L-7812-00 L-7980-00 L-7984-00 Individual parts are only available for bulk sales. Please refer to the appropriate repair kits on pages 11. Customer Service (704) 841-6000 www.apollovalves.com 9

INSTALLATION, OPERATION, & MAINTENANCE MANUAL Item # 16 17 Description T2 Inlet NPT Ball Valve w/ T Handle (Standard) T4 Inlet Union Ball Valve w/ T Handle (Option) T2 Inlet NPT Ball Valve w/ Lever Handle (Standard) T4 Inlet Union Ball Valve with Lever Handle (Option) T2 Inlet NPT Ball Valve with Locking T Handle (Option) T4 Inlet Union Ball Valve with Locking T Handle (Option) T2 Inlet NPT Ball Valve with Locking Lever Handle (Option) T4 Inlet Ball Union Valve with Locking Lever Handle (Option) T2 Outlet NPT Ball Valve with T Handle (Standard) T4 Outlet Union Ball Valve with T Handle (Option) T2 Outlet NPT Ball Valve with Lever Handle (Standard) T4 Outlet Union Ball Valve with Lever Handle (Option) T2 Outlet NPT Ball Valve with Locking T Handle (Option) T4 Outlet Union Ball Valve with Locking T Handle (Option) T2 Outlet NPT Ball Valve with Locking Lever Handle (Option) T4 Outlet Union Ball Valve with Locking Lever Handle (Option) Std. or LF Inlet and Outlet Shut-Off Valves Qty. Part Number 1/2 3/4 1 1-1/4 1-1/2 2 77B-103-85 77B-104-83 77B-105-83 LF 77BLF-103-85 77BLF-104-83 77BLF-105-83 77B-303-85 77B-304-83 77B-305-83 LF 77BLF-303-85 77BLF-304-83 77BLF-305-83 77B-106-84 77B-107-84 77B-108-84 LF 77BLF-106-84 77BLF-107-84 77BLF-108-84 77B-306-84 77B-307-84 77B-308-84 LF 77BLF-306-84 77BLF-307-84 77BLF-308-84 1 77B-104-91 77B-105-91 LF 77BLF-104-91 77BLF-105-91 77B-304-91 77B-305-91 LF 77BLF-304-91 77BLF-305-91 77B-106-86 77B-107-86 77B-108-86 LF 77BLF-106-86 77BLF-107-86 77BLF-108-86 77B-306-86 77B-307-86 77B-308-86 LF 77BLF-306-86 77BLF-307-86 77BLF-308-86 77C-103-A4 77C-104-83 77C-105-83 LF 77CLF-103-85 77CLF-104-83 77CLF-105-83 77C-303-85 77C-304-83 77C-305-83 LF 77CLF-303-85 77CLF-304-83 77C-305-83 77C-106-84 77C-107-84 77C-108-84 LF 77CLF-106-84 77CLF-107-84 77CLF-108-84 77C-306-84 77C-307-84 77C-308-84 LF 77CLF-306-84 77CLF-307-84 77CLF-308-84 1 77C-104-91 77C-105-91 LF 77CLF-104-91 77CLF-105-91 77C-304-91 77C-305-91 LF 77CLF-304-91 77CLF-305-91 77C-106-86 77C-107-86 77C-108-86 LF 77CLF-106-86 77CLF-107-86 77CLF-108-86 77C-306-86 77C-307-86 77C-308-86 LF 77CLF-306-86 77CLF-307-86 77CLF-308-86 Replacement Handles for Ball Valve Shut-Off Valves (T2 & T4 options) T Handle W-9732-00 W-9864-00 W-9734-00 Lever Handle W-9366-00 All Locking T W-2394-00 Locking Lever W-9686-00 Stainless steel handles are standard on all Apollo backflow devices. 10 www.apollovalves.com Customer Service (704) 841-6000

BFMM DC4A SBF REPAIR KITS DC4A & DCLF4A 1/2 2 Check Module Rubber Kit (One kit repairs one check) (Universal, for standard & lead free valves) QTY Size 1/2 3/4 1 1-1/4 1-1/2 2 Repair Kit Model Number RK4A12CMR RK4A34CMR RK4A1CMR RK4A112CMR RK4A2CMR Item # Ordering Number 4A-003-01 4A-004-01 4A-005-01 4A-007-01 4A-008-01 not Shown O-Ring Lubricant I-9016-00 11 Check Module Seat Disc 1 D-4771-00 D-4743-00 D-4770-00 D-4853-00 D-4873-00 7 Check Module O-Ring 1 D-4880-00 D-4744-00 D-4882-00 D-4884-00 D-4885-00 6 Cap O-Ring 1 D-4881-00 D-4812-00 D-4884-00 D-4885-00 D-4888-00 DC Checks Complete Kit (One kit repairs one check) (Universal, for standard & lead free valves) QTY Size 1/2 3/4 1 1-1/4 1-1/2 2 Repair Kit Model Number RK4A12CMC RK4A34CMC RK4A1CMC RK4A112CMC RK4A2CMC Item # Ordering Number 4A-003-02 4A-004-02 4A-005-02 4A-007-02 4A-008-02 not Shown O-Ring Lubricant I-9016-00 8 Check Module S-Assy 1 W-9075-05 W-9003-05 W-9074-05 W-9159-05 W-9204-05 7 Check Module O-Ring 1 D-4880-00 D-4744-00 D-4882-00 D-4884-00 D-4885-00 6 Cap O-Ring (for DC/RP) 1 D-4881-00 D-4812-00 D-4884-00 D-4885-00 D-4888-00 extra part(s) Bonnet O-Ring (for PVB) 1 D-4812-00 D-4883-00 D-4887-00 D-4858-00 DC Complete Internals Kit (One kit repairs ONE DC valve) (Universal, for standard & lead free valves) QTY Size 1/2 3/4 1 1-1/4 1-1/2 2 Repair Kit Model Number RK4A12TDC RK4A34TDC RK4A1TDC RK4A112TDC RK4A2TDC Item # Ordering Number 4A-003-08 4A-004-08 4A-005-08 4A-007-08 4A-008-08 not Shown O-Ring Lubricant I-9016-00 8 Check Module S-Assy 2 W-9075-05 W-9003-05 W-9074-05 W-9159-05 W-9204-05 7 Check Module O-Ring 2 D-4880-00 D-4744-00 D-4882-00 D-4884-00 D-4885-00 6 Cap O-Ring 2 D-4881-00 D-4812-00 D-4884-00 D-4885-00 D-4888-00 Customer Service (704) 841-6000 www.apollovalves.com 11

SOUTHEAST REGION SOUTHERN REGION MIDWESTERN REGION WESTERN REGION NORTHEAST REGION IRRIGATION ONLY REPS CANADA SALES & CUSTOMER SERVICE: Phone: (704) 841-6000 Fax: (704) 841-6020 www.apollovalves.com AGENCY AREAS COVERED EMAIL PHONE FAX Mid South Marketing, Inc. VA/MD/Washington, D.C./WV-East midsouth7@aol.com 804-213-3801 804-213-3802 Pro Marketing, Inc. NC/SC/TN-East sales@promarketinginc.net 864-578-4334 864-578-4889 Spirit Group FL (except Panhandle) info@spiritgroupinc.com 407-291-6035 407-299-0378 Tim Morales & Associates, Inc. AL/FL Panhandle sales@timmorales.com 251-602-8333 251-602-8339 White Wolf Group GA info@whitewolfgroupinc.com 800-401-4870 888-908-9372 BWC Inc. LA (Commercial Products) chuck@bwcassoc.com 504-734-0229 504-734-3711 Marathon Flow Control TX, OK, KS except Northeast, LA (Industrial) sales@marathonflowcontrol.com 214-201-0100 214-201-0104 Southern Marketing Group MS/TN-West/AR/Bowie Cty.-TX SMG49@bellsouth.net 901-547-0042 901-547-0035 FourMation Sales MN/ND/SD/WI-West ryan@fourmationsales.com 763-420-6900 763-420-6993 Marshall-Rodeno Heartland NE/IA (Except River Counties) trodeno@marshallrodeno.com 303-575-6701 303-575-6706 Midwest Spec KY/OH/PA-West/WV-West glsales@mwspec.com 330-538-0406 330-538-0410 New Tech Marketing Northern-IL/WI-East/IN/MI-UP/IA-River Counties sales@new-techmarketing.com 630-378-4300 630-378-0343 New Tech Marketing MO/Southern IL/Northeast Kansas ntm112@aol.com 618-394-0329 618-394-0427 V.E. Sales Co., Inc. MI (Except Upper Peninsula) tomv@vesalesinc.com 586-774-7760 586-774-1490 Elmco Duddy CA - South tduddy@elmcoduddy.com 626-333-9942 626-855-4811 Gordon & Associates WA, OR, AK, Northern counties ID laura@gordonandassoc.com 360-566-1470 360-566-1478 HC Fletcher CA - North (AB 1953 compliant product) apollosales@hcfletcher.com 800-432-7047 949-660-9072 Marshall-Rodeno Associated CO/WY/MT/ID-SE/UT/NV-NE/NM/El Paso-TX trodeno@marshallrodeno.com 303-575-6701 303-575-6706 Romatec CA - North PVF (non AB 1953) apollo@romatec.com 877-530-3530 661-588-3534 Southwest Valves CA (Waterworks and Fire Protection) d.burell@southwestvalve.com 559-261-2703 559-261-2711 Southwestern Industrial Sales Co. AZ/Nevada-SW eduardop@sw-ind.com 480-458-5838 480-458-5843 Spec Management Group HI msmarch4@cox.net 949-481-4225 949-487-0990 Conroy & Griese Sales, Inc. NY-East/NJ-North iezzi52@aol.com 856-663-4440 856-663-6644 Keith Engle & Associates OEM accounts keith.engle@verizon.net 610-827-9560 610-827-9561 Layden Company NY-Upstate/PA-East/DE/NJ-South joejr@laydencompany.com 610-363-6657 877-529-3361 Urell, Inc. MA/New England States conbraco@urell.com 617-923-9500 617-926-9414 Active Sales Northwest, Inc. OR, WA, Western ID skactive@aol.com 541-726-0320 541-726-1148 Biz Sales Company OH, KY, MI, IN, parts of PA, WV, WI dzavelson@bizpvf.com 216-595-2888 216-595-2899 Fourmation Sales MN/ND/SD/WI-West dean@fourmationsales.com 763-262-4700 763-262-4740 Hall Marketing AL, LA hallmarketing@bellsouth.net 228-547-4637 228-832-6666 J&J Midwest Sales NE, IA, MO, KS john@jandjmidwestsales.com 314-422-8419 Jim Benton & Associates AL, FL Panhandle jim@bentonandassoc.com 205-664-1221 205-664-1277 John Hart FL jhart@lascofittings.com 772-595-7773 772-489-4305 Larry Perkins TX - Southern lperkins@lascofittings.com 936-443-1096 Marel Enterprises New England, NY, DE, MD, VA, DC, parts of PA & WV marelenterprise@gmail.com 631-271-1718 631-427-8558 Marshall-Rodeno Associated CO/WY/MT/ID-SE/UT/NV-NE trodeno@marshallrodeno.com 303-575-6701 303-575-6706 NSC Marketing Group Inc. OK nsc_tulsa@sbcglobal.net 918-627-5340 918-664-1408 Pro Marketing, Inc. NC/SC/TN-East sales@promarketinginc.net 864-578-4334 864-578-4889 Sherman Dobbs TX - Northern sdobbs@lascofittings.com 469-442-8510 972-417-9733 Southern Marketing Group MS/TN-West/AR/Bowie Cty.-TX SMG49@bellsouth.net 901-547-0042 901-547-0035 Spec Management Group CA-South msmarch4@cox.net 949-481-4225 949-487-0990 VPC Sales AZ chudson@vpcsales.com 661-257-3923 661-257-3928 Agences J. Pierre Sylvain, Inc. Quebec agencespsylvain@golden.net 450-655-9588 450-641-2737 Barclay Sales Ltd. British Columbia bbarclay@barclaysales.com 604-945-1010 604-945-3030 Conbraco Industries, Canada 178 Pennsylvania Ave., Unit 1, Concord, Ontario L4K 4B1 conbraco.canada@conbraco.com 905-761-6161 905-761-6666 D & M Mechanical Sales Ontario/East don@dandmsales.ca 613-384-7084 613-384-3407 Dynamic Agencies, Ltd. Saskatchewan doug.dynamicage@sasktel.net 306-343-1901 306-343-1901 J. Levandier Sales, Inc. Nova Scotia, New Brunswick, Prince Edward Island & Newfoundland service@jlevandiersales 506-858-1615 506-858-1084 Kern Industries, Ltd. Alberta-North kernind@telusplanet.net 780-451-2056 780-454-6687 Kern Industries Calgary, Ltd. Alberta-South marty.yucytus@kernindustries.ca 403-730-7791 403-239-8179 Key to the North Sales Agency, Inc. Ontario-North hmehes@keytothenorth.ca 705-524-6714 705-566-0148 Task Controls, Inc. Ontario infotoronto@taskcontrols.com 416-291-3004 416-754-3481 Tom Beggs Agencies Ltd. Manitoba/NW Ontario tba@mts.net 204-953-1900 204-774-6915 BFMMDC4ASBF 1/12 3,000 CG current rep list as of 1/11/12