Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

Similar documents
INSTALLATION & MAINTENANCE MODEL mm

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

MAINTENANCE MANUAL. Covering Models: Series (1/4-10 ) S Series (1/4-1 ) Series (3-10 )

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

Colt Series C400, C500

2 ½ 12. Model RP 4A Model RPDA 4A Model RPDA2 4A. Installation, Operation, and Maintenance Manual

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

THIS WARRANTY IS IN LIEU

Series 867 Reduced Pressure Zone Assemblies

2 ½ 12. Installation, Operation, and Maintenance Manual. Reduced Pressure Principle Backflow Preventer. Reduced Pressure Detector Assembly

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

Series 995/995RPDA. Sizes: 3" - 6" Reduced Pressure Zone Backflow Preventer/ Reduced Pressure Detector Assemblies RP/IS-995/995RPDA

DC-501 Double Check Backflow Preventer OPERATIONS, MAINTENANCE AND TROUBLESHOOTING GUIDE

Installation, Maintenance, & Repair Series 919 and LF919

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers

Series 990/990RPDA. Reduced Pressure Zone Backflow Preventer. Sizes: 4", 6", 8" (100mm, 150mm, 200mm)

BFMM DC4A SBF EFFECTIVE AUGUST 1, 2016

Installation, Maintenance, & Repair Series 4000CIV

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

DIMENSIONS (approximate)

Series 009. Reduced Pressure Zone Assemblies. Installation Service Repair Kits Maintenance. Sizes: 8 80mm. 80mm 009LF RP/IS-009-AUS

Installation, Maintenance, & Repair Series 909, LF909, 909RPDA, LF909RPDA Reduced Pressure Zone Assemblies Reduced Pressure Detector Assemblies

Cash-Flo. Operation & Maintenance Manual. BackFLOW PREVENTERS. A Division of the Reliance Worldwide Corporation

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

Digital Print-out Test Kit for Backflow Preventer Assemblies

Maintenance Manual Double Check and Double Check Detector Assemblies Series 850, 856, 870V & 876V 2 1 /2" - 10" (65 250mm)

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

Voltmaster Centrifugal Trash Pumps

50-01 (Full Internal Port) (Reduced Internal Port) Pressure Relief. & Pressure Sustaining Valve MODEL

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

MADE IN THE USA BACKFLOW PREVENTERS

4P-300 4V-500 CONTINUOUS PRESSURE THERMOPLASTIC DUAL. PRINCIPLE (U & Z Flow) DUAL CHECK VALVE. PRINCIPLE (Stn.Steel) REDUCED PRESSURE

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

TECHNICAL DATA. Q= C v P S

FOR TECHNICAL ASSISTANCE

Technical Instructions

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

PRESSURE REDUCING VALVE

LAWN SPRINKLER, IRRIGATION PUMP

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

LEAD FREE * PVS-7000 Engineered Flood Protection Valve Station with SentryPlus Alert

Instructions for Installation, Operation, Care and Maintenance

Single-Valve Powerstation

P239-1 Supply Pumper Instructions

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

Wet pipe low flow foam/water manifold system

Backflow Preventers TABLE OF CONTENTS

CIRCLE SEAL CONTROLS

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features

Operation and Maintenance Manual

4 - Way Control 4 - Way Control 4 - Way Control with lock

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

TECHNICAL DATA 1-1/2 (dn40)

T60 REGULATOR REPAIR KIT INSTRUCTIONS

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

PRESSURE REDUCING CONTROL VALVE

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

MODEL G300 BRAKE BLEEDER

Inverted High Pressure Fluid Filters

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

Type 644 and 645 Differential Pressure Pump Governors

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

DCAP Series 40-4 X X - X X X. Dual Check w/ Atmospheric Port Backflow Preventers

Installation, Operation and Maintenance Manual

Fisher 644 and 645 Differential Pressure Pump Governors

FOR TECHNICAL ASSISTANCE

BACKFLOW PREVENTION CATALOG

Awide choice of devices

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

PRESSURE REDUCING VALVE

MODEL 900 IMPELLER-TYPE FLOW METER

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

Instructions for INSTALLATION -- OPERATION -- MAINTENANCE of the SELAS AIR/GAS BLENDER VALVE. (for PROPANE/AIR, BUTANE/AIR AND OTHER BLENDS)

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

Items # and #

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

Installation Service Repair Kits Maintenance RP/IS-774/774DCDA/774X/774XDCDA

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

Type EZR Relief Valve or Backpressure Regulator

Flow Control Valve IOM 770-U

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

HALLMARK INDUSTRIES INC

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

TYPE E Main Valve Sizes 3 /8 through 12

Instructions for Installation, Operation Care and Maintenance

Air-Assist Service Jack Max. Capacity: 10 Tons

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

Transcription:

Model RPHBM Hydrant Backflow Meter Installation Testing Maintenance Instructions CAUTION: Installation of Backflow Preventers must be performed by qualified, licensed personnel. The installer should be sure the proper device has been selected for the particular installation. Faulty installation could result in an improperly functioning device. The Model RPHBM Hydrant Backflow Meter consists of a 3" Hydrant Meter and integral Reduced Pressure Principle Backflow Preventer for use on water lines where usage must be metered and a health hazard could exist if a backflow situation were to occur. HYDRANT OUTLET SHUT-OFF VALVE (OPTIONAL) VENT HPM FHD AWWA CLASS II 6363782 B1 USA PAT Proper performance is dependent upon following these installation instructions and prevailing governmental and industry standards and codes. Failure to do so, according to Limited Warranty "...releases ZURN WILKINS of any liability that it might otherwise have with respect to that device." Such failure could also result in an improperly functioning device. Damage to the device could result wherever water hammer and/or water thermal expansion could create excessive line pressure. Where this could occur, shock arresters and/or pressure relief valves should be installed downstream of the device. 1. Before installing a Model RPHBM, flush the hydrant thoroughly to remove all debris, chips and other foreign matter. If required, a strainer should be placed upstream of the Hydrant Backflow Meter. 2. The Model RPHBM must be installed in a horizontal position to provide proper operation of the relief valve. Adjust stand height until valve is in horizontal position. For stability, ensure stand is placed on a solid surface. 3. If installation of a Model RPHBM is in a building, provide a suitable drain arrangement to drain off spillage from the relief valve. An air gap at least two times the pipe diameter must be provided between the relief valve and the drain piping to prevent a cross-connection. 4. Install valve at least 12 inches above surrounding flood level. 5. Always consult local codes for installation methods, approvals and guidance. 6. Model RPHBM Hydrant Backflow Meters must be protected against freezing conditions. Exposure to freezing conditions will result in improper function or damage to the device. The installation location must be kept above 32 F. All the basic installation instructions apply. SPECIFICATIONS: RV DISCHARGE PORT DIRECTION OF FLOW TYPICAL INSTALLATION RPHBM Hydrant Backflow Meter Maximum intermittent flow rate 650 GPM Maximum continuous flow rate 450 GPM Minimum flow rate 2-1/2 GPM Maximum working water pressure 175 PSI Maximum working water temperature 0 F Fire Department connection (2-1/2") NSFHT PLACING THE DEVICE IN SERVICE After the installation of a Model RPHBM has been completed, place the unit in service as follows: 1. Start with hydrant closed. Slowly open the hydrant until the RPHBM is completely pressurized. A brief discharge from the relief valve may occur while the device is pressurizing. The discharge should cease by the time the hydrant is fully open. If the discharge does not stop, refer to "MAIN- TENANCE INSTRUCTIONS" for repair procedures. 2. If the RPHBM has been equipped with optional downstream shut-off valve wait until the device has completely pressurized then vent all trapped air from both check valves by slightly opening each of the three test cocks. 3. The Model RPHBM is now in service. 4. If "spitting" or intermittent discharges from the relief valve are noted, it could be a result of pressure fluctuation and/ or a water hammer condition in the system. Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm. In accordance with U.S. Federal Safe Drinking Water Act Lead-Free requirements, as of January 4, 20, this product can only be used in water systems considered non-potable. Please contact your local water utility for further requirements.

Testing Procedures TEST NO. 1 - RELIEF VALVE OPENING POINT The differential pressure relief valve must operate to maintain the zone between the two check valves at least 2 psi less than the supply pressure. Note: It is recommended that testing be conducted in meter shop. 1. Slowly flush water through test cocks #1, #2 and #3 by opening and closing each test cock one at a time. 2. Install appropriate fittings to test cocks. Attach hose from the high side of the differential pressure gauge to the #1 test cock then attach hose from the low side of the gauge to the #2 test cock. Open test cock #2 slowly and then bleed all air from the hose and gauge by opening the low side bleed needle valve. 3. Maintain the low side bleed needle valve in the open position while test cock #1 is opened slowly. Open the high side bleed needle valve to bleed all air from the hose and gauge. Close the high side bleed needle valve, then close the low side bleed needle valve after the gauge reading has reached the upper end of the scale. 4. Close the downstream shut-off valve. 5. Open the high side control needle valve approximately one turn, and then open the low side control needle valve no more than 1/4 turn. Observe the differential pressure reading as it slowly drops to the relief valve opening point. Record this opening point value when the first discharge of water is detected. Close the low side needle valve. OUTLET SHUT-OFF VALVE (OPTIONAL) Note: Due to disc compression, you may need to bleed off water through low side bleed needle valve several times before the gauge reading will settle above relief valve opening point. TEST NO.3 - TIGHTNESS OF #1 CHECK VALVE The static pressure drop across #1 check valve shall be greater than the relief valve opening point (test #1), and at least 5.0 psid. 1. With the vent hose connected to test cock #3 as in step 3 of Test #2, bleed water from the zone through the low side bleed needle valve on the gauge until the reading exceeds the #1 check valve pressure drop. Close the low side bleed needle valve. After the gauge reading settles, the steady state differential pressure reading indicated is the actual static pressure drop across check valve #1 and is to be recorded as such. 2. Close all test cocks, slowly open downstream shutoff valve and remove equipment. TEST COCK #3 METER TEST COCK #2 TEST COCK #1 TEST NO. 2 - TIGHTNESS OF #2 CHECK VALVE The #2 check valve shall be tight against backpressure. 1. Vent all air through the vent hose by opening the vent needle valve. Close the vent needle valve only (The high side control needle valve is to remain open). 2. Attach the vent hose to the #3 test cock, then open the #3 test cock. Bleed water from the zone by opening the low side bleed needle valve. Once the gauge reading reaches a value above the #1 check valve pressure drop, close the low side bleed needle valve. 3. Open the vent needle valve. If the indicated differential pressure reading remains steady then the #2 check valve is reported as "closed tight." If the differential pressure reading falls to the relief valve opening point, bleed water through the low side bleed needle valve until the gauge reading reaches a value above the #1 check valve pressure drop. If the gauge reading settles above the relief valve opening point, record the #2 check valve as "closed tight". 2 HIGH SIDE HOSE VENT HOSE HPM FHD AWWA CLASS II USA PAT 6363782 B1 HGH SIDE BLEED NEEDLE VALVE LOW SIDE BLEED NEEDLE VALVE #1 CHECK VALVE LOW SIDE HOSE

Maintenance Instructions All Model RPHBM Hydrant Backflow Meters must be inspected and maintained at least once a year or more frequently as specified by local codes. Replacement of worn or damaged parts must only be made with genuine "" parts. The Certificate of Limited Warranty provides that failure to do so releases of any liability that it might otherwise have with respect to that device." Such failure could also result in an improperly functioning device. The Model RPHBM Hydrant Backflow Meter should be thoroughly flushed after backflow conditions occur to prevent any type of corrosive deterioration to its components. Failure to do so could result in malfunction of the device. Note: It is recommended that all valve maintenance be completed in meter shop. GENERAL MAINTENANCE 1. Clean all parts thoroughly with water after disassembly. 2. Carefully inspect rubber seal rings, diaphragms and o-rings for damage. 3. Test unit after reassembly for proper operation (see "Testing Procedures"). SERVICING CHECK VALVES 1. Close hydrant and downstream shut-off valve. 2. Open No. 1, No. 2 and No. 3 test cocks to release pressure from valve. 3. Prior to removing the #1 check housing, disconnect the sensing hose. 4. Remove check housings from main body. 5. Remove the checks from the housings. SERVICING RELIEF VALVE 1. Remove relief valve cover bolts and cover. Gently pull on diaphragm to remove the cartridge assembly. 2. Inspect seal ring for cuts and embedded debris. Turn over or replace if required. 3. Disassemble cartridge by unscrewing relief valve retaining screw. 4. Inspect diaphragm and o-rings for damage. Replace required parts and apply a light coat of grease to plunger o-ring. 5. Carefully reassemble cartridge assembly. 6. Inspect relief valve seat for wear on seating surface. If damaged, replace seat and seat o-ring. 7. Insert cartridge assembly into relief valve body. 8. Replace relief valve cover and cover bolts. 9. Place device in service and test per "TESTING PRO- CEDURES". #2 CHECK CHECK #2 METER RELIEF VALVE SENSING HOSE CHECK #1 #1 CHECK Note: Always service the checks one at a time to avoid mixing parts. SEAT ASSEMBLY 6. Start by removing the hardware and o-rings from the back of the check assembly (See Check Valve Assembly illustration). Separate the seal retainer from the assembly to expose the seal ring. 7. Inspect the seal ring for cuts or embedded debris. If the reverse side of the seal is unused, the seal ring can be inverted and used temporarily until a new seal is obtained. Inspect seat o-ring and replace if cut or damaged in any way. 8. Inspect valve cavity and seating areas. Flush with water to remove any debris. 9. Reverse the above procedures to reinstall check valve assembly. COVER BOLTS SEAL RING SEAL RETAINER CHECK VALVE ASSEMBLY DIAPHRAGM RETAINER SCREW SEAL RING SEAT SEAT WASHER NUT Note: Apply a light coating of an appropriate lubricant to the large check o-rings on check #1 and #2. COVER UPPER LOWER WASHER SPRING BODY 10. Close any remaining open test cocks and place valve back in service. RELIEF VALVE ASSEMBLY 3

Troubleshooting When the relief valve discharges intermittently it can be almost always assumed that the device is functioning correctly and that the discharge is caused by systems problem such as inlet pressure fluctuations or water hammer due to quick closing valves. PROBLEM POSSIBLE CAUSES CORRECTIVE ACTION 1. SUDDEN OR RAPID SPITTING 1. Drop in inlet pressure. 2. Sudden increase in downstream pressure due to water hammer from to quickly closing shut-off valve. A. Install an in-line spring loaded check valve upstream of back flow. B. Close downstream shut-off valve slowly 2. LIGHT INTERMITTENT DRIP 1. Slightly fouled #1 check A. Clean #1 check and turn check valve seal ring over or replace. Continuous discharge of the relief valve signifies a failure of some part of the device. To help determine the specific area of failure, close the #2 shut-off valve. If the discharge stops, the #2 check requires service. If the discharge continues, the #1 check requires service. 1. CONTINUOUS DISCHARGE 1. Fouled #1 check. 2. Fouled relief valve seat. 3. Fouled #2 check. A. Clean check valves and turn check valve seal rings over or replace. B. Clean relief valve seat and turn relief valve seal ring over or replace. In summation, the amount of discharge is proportional to degree of fouling. Most problems occur in the #1 check which is where debris enters the backflow preventer first. Repair Kit RELIEF RUBBER ONLY RELIEF COMPLETE CHECKS ONLY RK212-375R RK212-375 RK212-350 PRESSURE LOSS (PSID) 60 50 40 30 20 10 0 MODEL RPHBM, 3" (STANDARD & METRIC) FLOW RATE (l/s) 0.0 3.2 6.3 9.5 12.6.8 18.9 22.1 25.2 28.4 31.5 0 50 100 0 200 250 300 350 400 450 500 FLOW RATE (GPM) 4 276 138 0 PRESSURE LOSS (kpa) Proper performance is dependent upon licensed, qualified personnel performing regular, periodic testing according to ' specifications and prevailing governmental & industry standards and codes and upon following these installation instructions. Failure to do so releases of any liability that it might otherwise have with respect to that device. Such failure could also result in an improperly functioning device. 4

Replacement Parts ITEM DESCRIPTION Wilkins P/N 1A Screw Skt Cap SS M5-0.8 x 16 HBM-11A 1B Screw Skt Cap SS M5-0.8 x 16, drill hole HBM-11B 2 Washer Lock Wave CU M5 x 10 HBM-A 3 Cover Retaining Ring and Lid, Brass HBM-20 4-CF Register, 3" Turbine, Cubic Feet HBM-1CFM 4-CM Register, 3" Turbine, Cubic Meters HBM-1CMM 4-US Register, 3" Turbine, U.S. Gallon HBM-1 5 Magnet Barrier Ring HBM-26 6A Bolt Hex Cap SS 1/2-13 x 1.5 HBM-11C 6B Bolt Hex Cap SS 1/2-13 x 1.5, drilled hole HBM-11D 7 Washer Flat SS.5 ID x.875 OD HBM-B 8 FHM Double Handle, SS HBM-6 9 Screw Slot Pan SS M5-0.8 x 28 HBM-11E 10 FHM Flat Al Cvr Plt, Pwdr. Coat Wilkins Blue HBM-3A 11 Turbine Meter Measuring Element, 3" HBM-25 12 O-Ring for Measuring Element HBM-22A 13 FHD Meter Body, Pwdr. Coat Wilkins Blue HBM-20A Test Cock, 1/4", Brass, w/cap -860FT Bolt Hex Washer Head SS 5/16-18 x 1 HBM-11F 16 FHD Strainer Cvr, Pwdr. Coat Wilkins Blue HBM-3B 17 FHP Strainer Gasket HBM-13A 18 FHD Strainer Screen, SS (Secondary) HBM-41A 19 FHP Strainer Screen (Primary) HBM-41B ITEM DESCRIPTION Wilkins P/N 20 Nipple 2.5"NH x 3"MIP, Brass HBM-19A 21 FHD Rear Housing, Pwdr. Coat Wilkins Blue HBM-20B 22 O-Ring, FHD Housing Front and Rear Seal HBM-22B 23 Valve Check 3" 375 #2 Wilkins 3507-300A 24 Valve Check 3" 375 #1 Wilkins 3707-300 25 FHD Front Housing, Pwdr. Coat Wilkins Blue HBM-20C 26 Swivel 2.5"SW x 3"MIP, Brass, w/ss strainer HBM-19B 27 Swivel Gasket for 2-1/2" FHM Swivel HBM-13B 28 Perf. Hydrant Stand for FHD Meter HBM-55A 29 Washer Flat SS 3/8 x 3/4 HBM-C 30 Bolt Hex Cap SS 3/8-16 x 1 HBM-11G 31 O-Ring, Control Unit, 032N 032N 32 Control Unit 3707-CU 33 Sensing Tube Fitting 5758A-36 34 Fitting, Elbow, 1/4NPT x 3/8 Comp 3707-38B 35 Sensing Tube 3/8 x 3/8 x 9 3710-36 36 Nipple, 1/4-18NPT x 1.5, Brass X1.5-21B Misc Seal, Tamper, Twist-Lock Wire, Copper, 3 Ply x.018 (for tamper seal) Complete FHD Unitized Measuring Elem. Assy, includes items 1,2,3,4,5,9,10,11 and 12 listed above. **=US, CF or CM HBM-90A HBM-90B HBM-ME HBM-MECFM HBM-MECMM 1 2 3 5 4 6 7 8 9 2 16 17 18 10 11 12 13 19 20 21 22 23 24 22 25 26 27 28 29 30 31 32 33 36 34 35 ISRPHBM (REV. 8/) 5