PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Similar documents
STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

DIESEL GENERATOR SET FEATURES

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

PRIME 1360 ekw 1700 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1250 ekw 1562 kva 60 Hz 1800 rpm 480 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1600 ekw 2000 kva 50 Hz 1500 rpm Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 480 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

PRIME 225 ekw 281 kva

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

DIESEL FEATURES GENERATOR SET

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

Voltage 220 to or 1800 RPM

Mission Critical Standby 1800 ekw 2250 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

3412C Generator Set Electric Power. Specifications. Benefits and Features

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

Mission STANDBY Critical Standby 2000 ekw 2500 kva 60 Hz 1800 rpm 480 Volts

Prime 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

Caterpillar 2500 kw 3516C

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

Specifications. 3406C Generator Set Electric Power

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

PRIME 292 ekw 365 kva 50 Hz 1500 rpm 400 Volts

220 to volts. Electronic unit injection

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Specifications. C13 Generator Set Electric Power

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

PRIME 480 ekw 600 kva 50 Hz 1500 rpm 400 Volts

ESP 550 ekw 688 kva 60 Hz 1800 rpm 480 Volts

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

Transcription:

DIESEL GENERATOR SET PRIME 800 ekw 1000 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Image shown may not reflect actual package. FEATURES DESIGN CRITERIA The generator set accepts 100% rated load in one step and meets ISO 8528-5 transient response. FULL RANGE OF ATTACHMENTS Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation SINGLE-SOURCE SUPPLIER Fully prototype tested with certified torsional vibration analysis available WORLDWIDE PRODUCT SUPPORT Caterpillar dealers provide extensive post sale support including maintenance and repair agreements Caterpillar dealers have over 1,600 dealer branch stores operating in 200 countries The Cat S O S SM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products CAT C32 ATAAC DIESEL ENGINE Utilizes ACERT Technology Reliable, rugged, durable design Four-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight Electronic engine control CAT GENERATOR Designed to match the performance and output characteristics of Caterpillar diesel engines Single point access to accessory connections UL 1446 recognized Class H insulation CAT EMCP 3 SERIES CONTROL PANELS Simple user friendly interface and navigation Scalable system to meet a wide range of customer needs Integrated Control System and Communications Gateway

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT System Standard Optional Air Inlet Single element canister type air cleaner Service indicator Dual element air cleaners Air inlet adapters Cooling Radiator with guard (43ºC) Low profile (frontal area) Radiator with 27ºC ambient capability Jacket water heater Low airflow Coolant drain line with valve Fan and belt guards Caterpillar Extended Life Coolant Coolant level sensors Radiator duct flange Exhaust Dry exhaust manifold Flanged faced outlets Stainless steel exhaust flex fittings Elbows, flanges, expanders & Y adapters Fuel Primary fuel filter with water separator Secondary fuel filter Fuel priming pump Flexible fuel lines Fuel cooler Generators Class H insulation Class F temperature (105ºC prime/130ºc standby) Winding temperature detectors (select models) Anti-condensation space heaters Oversize & premium generators Power Termination Bus bar (NEMA and IEC mechanical lug holes) -right side standard Bottom cable entry Governor ADEM A4 Load Share Module Circuit breakers, UL listed, 3 pole with shunt trip,100% rated, choice of trip units, manual or electrically operated (low voltage only) Circuit breakers, IEC compliant, 3 or 4 pole with shunt trip (low voltage only), choice of trip units, manual or electrically operated Shroud cover for bottom cable entry Power terminations can be located on the left and/or rear as an option. Also, multiple circuit breakers can be ordered (up to 2) Top cable entry Control Panels EMCP 3.1 User Interface panel (UIP) - rear mount Emergency Stop Push button Lube Mounting Starting/Charging General Lubricating oil and filter Oil drain line with valves Fumes disposal Gear type lube oil pump Formed steel welded base Anti-vibration mounts (shipped loose) 24 volt starting motor(s) Batteries with rack and cables Battery disconnect Right-hand service Paint - Caterpillar Yellow (except rails and radiators that are gloss black) SAE standard rotation Flywheel and Flywheel housing - SAE No. 0 EMCP 3.2 and EMCP 3.3 Right or left mount UIP Local & remote annunciator modules Discrete I/0 Module Generator temperature monitoring & protection Load share module Deep sump oil pan Battery chargers (10 Amp) 45 amp charging alternator Oversize batteries Ether starting aid UL 2200 CSA certification EU Declaration of Incorporation EEC Declaration of Conformity 2

SPECIFICATIONS CAT GENERATOR SR4B Generator Frame size... 693 Excitation... Permanent Magnet Pitch... 0.7222 Number of poles...4 Number of bearings... 2 Number of Leads... 12 Insulation... UL 1446 Recognized Class H with tropicalization and antiabrasion IP rating...drip Proof IP22 Alignment... Close Coupled Overspeed capability - % of rated... 180 Wave form...003.00 Voltage regulator.3 Phase sensing with selectible volts/hz Voltage regulation...less than +/- 1/2% (steady state) Less than +/- 1% (no load to full load) Telephone Influence Factor... Less than 50 Harmonic distortion... Less than 5% CAT DIESEL ENGINE C32 TA, V-12, 4-stroke watercooled diesel Bore - mm... 145.00 mm (5.71 in) Stroke - mm... 162.00 mm (6.38 in) Displacement - L... 32.10 L (1958.86 in 3 ) Compression ratio... 15.0:1 Aspiration... TA Fuel system...meui Governor type...adem A4 CAT EMCP 3 SERIES CONTROLS EMCP 3.1 (Standard) EMCP 3.2 / EMCP 3.3 (Option) Single location customer connector point True RMS metering, 3-phase Controls - Run / Auto / Stop control - Speed Adjust - Voltage Adjust - Emergency Stop Pushbutton - Engine cycle crank Digital Indication for: - RPM - Operating hours - Oil Pressure - Coolant temperature - System DC volts - L-L volts, L-N volts, phase amps, Hz - ekw, kva, kvar, kw-hr, %kw, PF (EMCP 3.2 / 3.3) Shutdowns with common indicating light for: - Low oil pressure - High coolant temperature - Low coolant level - Overspeed - Emergency Stop - Failure to start (overcrank) Programmable protective relaying functions: (EMCP 3.2 & 3.3) - Under and over voltage - Under and over frequency - Overcurrent (time and inverse time) - Reverse power (EMCP 3.3) MODBUS isolated data link, RS-485 half duplex (EMCP 3.2 & 3.3) Options - Vandal door - Local annunciator module - Remote annunciator module - Input / Output module - RTD / Thermocouple Modules - Monitoring software 3

TECHNICAL DATA Open Generator Set - - 1500 rpm/50 Hz/400 Volts DM9946 Generator Set Package Performance Genset Power rating @ 0.8 pf Genset Power rating with fan 1000 kva 800 ekw Coolant to aftercooler Coolant to aftercooler temp max 49 º C 120 º F Fuel Consumption 100% load with fan 75% load with fan 50% load with fan Cooling System 1 Air flow restriction (system) Air flow (max @ rated speed for radiator arrangement) Engine Coolant capacity with radiator/exp. tank Engine coolant capacity Radiator coolant capacity 224.4 L/hr 59.3 Gal/hr 168.2 L/hr 44.4 Gal/hr 115.2 L/hr 30.4 Gal/hr 0.12 kpa 0.48 in. water 1031 m³/min 36409 cfm 190.0 L 50.2 gal 55.0 L 14.5 gal 135.0 L 35.7 gal Inlet Air Combustion air inlet flow rate 72.0 m³/min 2542.7 cfm Exhaust System Exhaust stack gas temperature Exhaust gas flow rate Exhaust flange size (internal diameter) Exhaust system backpressure (maximum allowable) Heat Rejection Heat rejection to coolant (total) Heat rejection to exhaust (total) Heat rejection to aftercooler Heat rejection to atmosphere from engine Heat rejection to atmosphere from generator Alternator 2 Motor starting capability @ 30% voltage dip Frame Temperature Rise 501.2 º C 934.2 º F 193.9 m³/min 6847.5 cfm 203 mm 8 in 10.0 kpa 40.2 in. water 289 kw 16435 Btu/min 870 kw 49477 Btu/min 224 kw 12739 Btu/min 119 kw 6768 Btu/min 42.1 kw 2394.2 Btu/min 1982 skva 693 105 º C 189 º F Lube System Sump refill with filter 68.0 L 18.0 gal Emissions (Nominal) 3 NOx mg/nm3 CO mg/nm3 HC mg/nm3 PM mg/nm3 1851.0 mg/nm³ 77.2 mg/nm³ 15.1 mg/nm³ 9.8 mg/nm³ 1 For ambient and altitude capabilities consult your Caterpillar dealer. Air flow restriction (system) is added to existing restriction from factory. 2 UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics. Generator temperature rise is based on a 40ºC ambient per NEMA MG1-32. 3 Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D & E and ISO8178-1 for measuring HC, CO, PM, NOx. Data shown is based on steady state operating conditions of 77ºF, 28.42 in HG and number 2 diesel fuel with 35º API and LHV of 18,390 btu/lb. The nominal emissions data shown is subject to instrumentation, measurement, facility and engine to engine variations. Emissions data is based on 100% load and thus cannot be used to compare to EPA regulations which use values based on a weighted cycle. 4

RATING DEFINITIONS AND CONDITIONS Meets or Exceeds International Specifications: AS1359, CSA, IEC60034-1, ISO3046, ISO8528, NEMA MG 1-22, NEMA MG 1-33, UL508A, 72/23/EEC, 98/37/EC, 2004/108/EC Prime - Output available with varying load for an unlimited time. Average power output is 70% of the prime power rating. Typical peak demand is 100% of prime rated ekw with 10% overload capability for emergency use for a maximum of 1 hour in 12. Overload operation cannot exceed 25 hours per year. Prime power in accordance with ISO3046. Prime ambients shown indicate ambient temperature at 100% load which results in a coolant top tank temperature just below the alarm temperature. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions. Fuel rates are based on fuel oil of 35º API [16º C (60º F)] gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C (85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional ratings may be available for specific customer requirements, contact your Caterpillar representative for details. For information regarding Low Sulfur fuel and Biodiesel capability, please consult your Caterpillar dealer. 5

DIMENSIONS Package Dimensions Length 4666.9 mm 183.74 in Width 2044.4 mm 80.49 in Height 2213.0 mm 87.13 in Weight 8256 kg 18,201 lb NOTE: For reference only - do not use for installation design. Please contact your local dealer for exact weight and dimensions. (General Dimension Drawing #2763027). Performance No.: DM9946 Feature Code: C32DE03 Gen. Arr. Number: 2628094 Source: U.S. Sourced September 29 2009 15202982 6 www.cat-electricpower.com 2009 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, SAFETY.CAT.COM their respective logos, "Caterpillar Yellow," and the POWER EDGE trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.