ON/OFF zone valves AMZ 112, AMZ 113

Similar documents
ON/OFF zone valves AMZ 112, AMZ 113

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Pressure relief controller AVA (PN 25)

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water

Flow controller (PN 25) AVQ - return and flow mounting

Premounted Midi Shunts

Flow-compensated temperature controller AVTQ DN 15

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

Two- and three way valves VFG.. / VFGS 2 / VFU.. for self-acting thermostats and electrical actuators

Assisted lift operated 2/2-way solenoid valves Type EV251B

Steel butterfly valves SBFV (PN 16/25)

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25)

Extensions to a comprehensive product range

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

ESBE Series 60 Electronic Motor Actuator (Combined with ESBE 3&4-way rotary valves)

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

High Capacity Valve Body, Type RA-G

Valve bodies type RA-N with integrated presetting

BALL VALVE - 10 SERIES Electric actuator - El-O-Matic

Installation Instructions Bus Bar Kit for 6-pulse, 4-drive System VLT Series FC 102, FC 202, and FC 302. Description. Kit Part Number.

ESBE Series 90 Electronic Motor Actuator (Combined with ESBE 3&4-Way Rotary Valves)

3 & 4-Way Rotary Valves

Starting Torque Limiter Type TCI (Soft Start)

SonoSensor 30 Ultrasonic flow sensor

Modulating control valves with magnetic actuators, PN 16

Actuators for modulating control AME 110 NL, AME 120 NL

VALVE WITH UV ACTUATOR

Manual Presetting Valves LENO MSV-B

502 VALVE WITH UM1.5 ELECTRIC ACTUATOR. Model/Ref:

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Let motorized intelligence solve your application challenges

2-position electric actuators with Ball valves VBZ ½...11/4

technical brochure 3-/4-WAY ROTARY MIXING VALVES ARV ProClick ELECTRIC ACTUATORS ARM ProClick

Manual presetting valves LENO MSV-BD

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

502 VALVE WITH UM ELECTRIC ACTUATOR

Installation Guide. DEVIreg 527. Electronic Time Regulator.

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

XS VALVES WITH UM ELECTRIC ACTUATOR

Actuators for small valves

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

Z2 050 Q -J +CQB 24 -SR -L

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

Automatic balancing valves ASV-PV DN (3rd gen.)

VALVES WITH SA03 ELECTRIC ACTUATOR

Modulating control valves with magnetic actuator PN 16

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

Premounted Midi Shunts

Electromotoric actuators

Seated valves (PN 16) VRG 2 2-way valve, external thread VRG 3 3-way valve, external thread

SonoMeter 30 Energy Meters

VALVES WITH NA ELECTRIC ACTUATOR

Electromotoric Actuators

Zone Valves and Parts (Honeywell)

502 VALVE WITH UM ELECTRIC ACTUATOR

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

Reliable season change

Liquid cooled heavy duty converter

VALVES WITH UM ELECTRIC ACTUATOR

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007

2-Port and 3-Port Zone Valves, PN 16 / 20

TA-6-way valve. Standard control valves 6-way valve for change-over systems

The precise step to take

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

ROTARY MOTORIZED VALVES

VALVES WITH UV ELECTRIC ACTUATOR

VALVE WITH UV ELECTRIC ACTUATOR

Electro-hydraulic actuators for valves

Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting

Installation Instructions In-back/Out-back Cooling Kit for D5h/D6h and D7h/D8h Enclosures VLT Series FC 102, FC 202, and FC 302

Configurations: s.64. s.31. s.74 3 way. Flow: Mini 2 way Direct mount. Flow: Full. Flow: Standard 3 way. ISO 5211 F03 Flange

2-Port and 3-Port Zone Valves PN 16

BALL VALVE SERIES Electric actuator - El-O-matic

COMPONENTS FOR SOLAR THERMAL SYSTEMS

G3 (D) 3-way Globe Valve, Bronze Trim

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

Modulating control valve with magnetic actuator PN16

2-port and 3-port valves with T-bypass PN 16

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

ELIMINATOR Hermetic filter drier Types DML and DCL

SonoMeter 30 Energy Meters

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

2-port and 3-port ball valves PN 40

Motorized Butterfly Valve

EL5600 Series Electric Actuators for DN15 to DN100 Valves

Modulating control valves with magnetic actuators, PN 16

3-port seat valves, external thread, PN16

2-Port and 3-Port Zone Valves PN 16

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Transcription:

Data sheet ON/OFF zone valves AMZ 112, AMZ 113 Description The ON/OFF zone valves type AMZ 112 and AMZ 113 are typical used in connection with: Domestic and commercial central heating applications Domestic hot water applications Solar energy plants Priority control of hot water supply and heating (diverting function) Priority control of boiler and solid fuel installations (diverting function). The ON/OFF zone valves can be applied together with most Danfoss Room Thermostats, particulary type RET 230 (single poled switch) and programmable Room Thermostats type RET 1000/2000. Other compatible room thermostats are available, please see www.danfoss.com/heating for details. Features: Indication of actual valve position; LED indication of turning direction; Manual valve turning mode enabled by a permanent clutch; No damage in case of valve blocking; Silent and reliable operation; Maintenance free; Integrated AUXILIARY switch; LED indication of activated AUXILIARY switch. Main Data: Nominal voltage: - 230 V AC, 50/60 Hz - 24 V AC, 50/60 Hz Rotation angle 90 Actuator running speed - AMZ 112 - DN 15-20: 30 sec / 90 - DN 25-50: 60 sec / 90 - AMZ 113 - DN 15: 30 sec / 90 - DN 20-32: 60 sec / 90 Control signal: 2-point Ordering AMZ 112 2-port valve/actuator DN k VS Code No. Connection (m 3 /h) 230 V 24 V 20 28 Cu-Cu 22-082G5427 15 17 R p ½ 082G5406 082G5400 20 28 R p ¾ 082G5407 082G5401 25 39 R p 1 082G5408 082G5402 32 84 R p 1¼ 082G5409 082G5403 40 156 R p 1½ 082G5410 082G5404 50 243 R p 2 082G5411 082G5405 AMZ 113 3-port valve/actuator DN k VS Code No. Connection (m 3 /h) 230 V 24 V 15 4,3 R p ½ 082G5418 082G5412 20 8,3 R p ¾ 082G5419 082G5413 25 13 R p 1 082G5420 082G5414 32 21 R p 1¼ 082G5421 082G5415 Danfoss 2016.02 VD.IR.J5.02 1

Technical data Actuator Power supply V 24 AC or 230 AC Power consumption VA AMZ 112: 2,5 AMZ 113: 3,5 Frequency Hz 50/60 Running speed 1) sec/90 30, 60 Control input 2-point Operating torque Nm 5, 10, 15 Rotation angle 90 Auxiliary switch adjustable 0-90 Auxiliary switch max. load A 6 (24V AC, 230V AC) Max. medium temperature Ambient temperature C 0 50 Storage and transport temperature 10 80 Protection Class II according to EN 60730-1 Grade of enclosure IP42 according to EN 60529 Weight Color / material AMZ 112 728 g AMZ 113 906 - marking in accordance with standards 110 dark grey/pc Low Voltage Directive 2006/95/EC EMC-Directive 2004/108/EC RoHS II: 2011/65/EU Applied standards: EN 60730-1, EN 60730-2-14 1) 5 Nm is 30 sec/90 ; 10, 15 Nm is 60 sec/90 Valve AMZ 112 DN 15 20 25 32 40 50 Nominal pressure PN 40 25 Flow (k VS ) m 3 /h 17 28 39 84 156 243 Medium temperature C 2 130 (Actuator max. 110) Medium Drinking water, water, glycol 50%, air, nonaggressive fluids Max. operating Δp bar 6 Valve neck ISO 5211 Connection Internal thread Rp ISO 7/1 Certifications and standards CE-PED CSA - GOST Materials Body CW 617 N UNI EN 12165 Ball, Stem CW 614 N UNI EN 12164 Antifriction ring PTFE Valve AMZ 113 DN 15 20 25 32 Nominal pressure PN 40 Flow (k VS ) m 3 /h 4,3 8,3 13 21 Medium temperature C 2 130 (Actuator max. 110) Medium Drinking water, water, glycol 50%, air, nonaggressive fluids Max. operating Δp bar 6 Valve neck ISO 5211 Connection Internal thread Rp ISO 7/1 Certifications and standards CE-PED CSA - GOST Materials Body CW 617 N UNI EN 12165 Ball, Stem CW 614 N UNI EN 12164 Antifriction ring PTFE 2 Danfoss 2016.02 VD.IR.J5.02

Application principles DEN-SMT DEN-SMT 82G318.10 ON/OFF control of Radiator -, under floor heating and zone systems (night set back). ON/OFF control of one or more heating/ surfaces. DEN-SMT Priority control of hot water supply and heating - diverting function. Priority control of boiler and solid fuel installations - diverting function. Installation positions Hydraulic installation Recommended installation of the eletric actuated ball valve 1. Ball valve 2. Strainer 3. AMZ VD.IR.J5.02 Danfoss 2016.02 3

Manual override 1 2 Close Open AMZ 112 AMZ 113 LED signalling LED orange (Rotate Left) LED red LED orange (Rotate Right) AMZ 112/113 LED color 2-point orange Rotation Left / Right red AUX switch activation Wiring N L 230V(24V) ~ Under cover 0 1 1 0 Direct/Inverse function Jumper Wiring Open Port 1 2 3 4 5 0 1 DIR L = 2 AB-B 1 2 3 4 5 6 N L L = 2 & 3 AB-A 1 0 INV L = 2 AB-A 2-point+switch L = 2 & 3 AB-B 4 Danfoss 2016.02 VD.IR.J5.02

Dimensions AMZ 112 - Copper connection B L AMZ 112 DN Connection L B N G mm 20 Cu-Cu 22 111,5 33 37 AMZ 112 Connection L B N DN G mm 15 ½ 61 29,4 37 20 ¾ 69,5 33 37 25 1 84,5 37,2 42 32 1¼ 98,5 47,5 42 40 1½ 110 53 42 50 2 130 64 48 VD.IR.J5.02 Danfoss 2016.02 5

Dimensions (continuous) AMZ 113 Connection L B N DN G mm 15 ½ 64,5 38 49,5 20 ¾ 78 42 59,5 25 1 97 46,5 74,5 32 1¼ 118 61,25 95,5 6 Danfoss 2016.02 VD.IR.J5.02

VD.IR.J5.02 Danfoss 2016.02 7

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 8 Danfoss DHS-SRMT/SI 2016.02 VD.IR.J5.02