3.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology

4.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology

OPTIMIZING COMMERCIAL SOLAR

PV Vault Yielding safety quickly

PHOTOVOLTAIC SYSTEMS

EXTERIOR BASE MOUNT INSTALLATION (FIG. 2)

City of Manhattan Beach Community Development

RAPID SHUTDOWN COMBINER

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

Solar PV General Introduction Guide for Electricians

EXPANSION JOINT DETAILS DURA-BLOK CONDUIT SUPPORT CONDUIT ATTACHMENT DETAIL SCALE: NOT TO SCALE GROUNDING WIRE DETAIL SCALE: NOT TO SCALE

STREAMLINED SOLAR CHECKLIST Owner Name:

2016 Photovoltaic Solar System Plan Review List

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection

SAMPLE PERMIT APPLICATION PACKAGE

City of Manhattan Beach Community Development

EELE408 Photovoltaics Lecture 22: Grid Tied Systems

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

Price List & Catalog Q1/Q2/Q3 2016

OVERHEAD SERVICE. Items to consider

Microinverters and AC PV modules are becoming. Microinverters and AC PV Modules. Different Beasts. Perspectives on PV.

Photovoltaic Solar Plan Review

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Commercial PV Projects with AEE Solar

Health & Safety Issues Associated with Solar Photovoltaic (PV)

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

SunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE

SunWize SW and OEM Series Solar Modules GENERAL INSTALLATION & USER GUIDE

Solar Electric Installation Requirements

A B C D E F. Tools Required (supplied by others)

Installation Manual. Opal Solar QSA Series

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series:

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Product manual Rapid Shutdown (RSD) system for residential and small commercial

My Reserve 500 Install Guide

Pika Energy Island Made in America

COVER VICINITY MAP SCOPE OF WORK ELECTRICAL NOTES GOVERNING CODES SHEET INDEX

RSDCOM. Installation and Operation Guide. Commercial Rapid Shutdown Combiner. DOCR Published March 2017 Revision C English

Datasheets. Residential On-Grid Photovoltaic System Kits

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

Washoe County PLAN SUBMITTAL

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

CHAPTER 10 ELECTRICAL. Notes:

Components for your PV Solar Electric System

Photovoltaic Installation Portfolio

Micro3 Grid Tied Residential Package

Residential Transition Box. Model RU-1. Specifications. Electrical

33'-10"± ROOF #1 (2) SUNPOWER SPR E C-AC MICROINVERTER MODULES ROOF #2 (13) SUNPOWER SPR E C-AC MICROINVERTER MODULES 78'-9"± 25'-5"

RGS PV-000. Sheet List

Load Side PV Connections

Bulletin Wiring methods for solar photovoltaic systems Rules 2-034, , , , , Tables 11 and 19

CP /240-MC4 User Manual

City of Daly City Department of Economic and Community Development Building Division th Street, Daly City. CA

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

Renogy MTS-TM100. Flat Roof Tilt Mount E Philadelphia St, Ontario, CA Version: 1.1

Residential Photovoltaic (PV) Packet

2.0 RAIL FREE SOLAR ROOF MOUNT. Utilizes EcoFasten Solar s patented technology

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual

Safety and Installation Instructions

XXX RESIDENCE : XXX kw DC GROUND MOUNTED PHOTOVOLTAIC SYSTEM

Solar Power Installation Application

Installation Manual. Polar Bear III HD 5 Degree. Document Number Rev D March panelclaw.com

Solar Photovoltaic (PV) Design Considerations & Issues. By Paul M. Williams, President & CEO

Installation and Operations Manual

Solar PV Standard Electrical Plan

Job Sheet 6 Installing the Combiner Box

ENGINEERING SPECIFICATION

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

2. Fire Department Inspections are required and available by appointment on Tuesdays and Wednesdays. See item number four for fees.

NC PV DG Program SEPA Presentation. December 15, 2011

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

APPROACHING. The Inverter. 92 IAEI NEWS May.June approaching the inverter

NABCEP s Solar PV Installer Exam is notoriously hard. Here are 50 practice questions to help you pass.

Green Building Technology

GET GROUNDED. Renewable Energy System Grounding Basics

Product Manual. Installation Instructions for CHSM-230M Series Solar Module

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

Code Calculations. for an Off-Grid PV System

Technical Summary of Battery Energy Storage Systems

Inspector Training Workshops Module One Photovoltaic Labeling based on 2008 NEC

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

Installation Instructions

SECTION SOLAR ENERGY ELECTRICAL POWER GENERATION SYSTEM

TerraSAS High-Performance 600V PV simulator

THIS PANEL FED FROM INV1. PER NEC 408.4(B) Part No NEC (C) Entrances to rooms or other guarded locations that contain exposed live

INSTALLATION MANUAL. IEC version. TSM_IEC_IM_2012_RevB

Solar Combiner Solutions

Philadelphia Solar Installation and Operation Manual

Switch-disconnectors OTDC and OTDCP

Schletter. Solar Mounting Systems

ROLLER SHADE SPECIFICATIONS

SPEEDFAX TM 2011 Renewable Energy Products Contents

Transcription:

FRONIUS RAPID SHUTDOWN BOX MOUNTING OPTIONS For Rail and Rail-less systems on L-feet, stand-offs, and other attachment types Summary The Fronius Rapid Shutdown Boxes (RSBs), Multi- and Single string versions, are designed for wall and roof-top mounting with 600V maximum rated PV systems. Any mounting design must consider PV source circuit wire runs and PV output circuit conduit runs. Both RSBs include water-tight glands/connectors for PV source circuit inputs (PV Wire, USE-2, etc.) and a pre-drilled hole for the PV output circuit using home-run wiring (THHN, THWN-2, etc.) inside appropriate conduit. To maintain the box s NEMA 4X rating, only water-tight fittings should be used and unused gland fittings should be plugged with included black plugs. The wall mounting is achieved with wood, metal, or masonry fasteners through fabricated holes in the base of the RSB. Roof-top mounting can vary depending on the mounting system and roofing material. In general, the included bracket is attached to the rail of a rail-based system but a different attachment method might be required if using a rail-less system. For ideal aesthetics, the RSB may be installed under the array unless there is insufficient vertical clearance; it should fit between the roof surface and the rear of the module while providing an air gap for each, as determined by the local AHJ. Please review Appendix A for the NEC code regarding installation of an electrical box under a PV module, and access to the provided DC disconnect. Figure 1: Fronius Rapid Shutdown Box installation Wall Mounting If a portion of the array is within 10 feet of a vertical surface (wall, side of dormer, parapet, etc.), it can be mounted onto that surface. In this case, mount the RSB without the included bracket, being mindful of providing room for the conduit run back to the inverter. Four anchors are needed (as illustrated) Roof Mounting Since the RSBs are NEMA 4x rated, they can be placed horizontally, vertically, or tilted on a roof. When mounted to racking via the bracket, the un-affixed end is providing additional stability by the conduit attachment. Figure 2: Wall mounting of RSB Rail-based System The larger mounting bracket is designed for bolting to the top or side of a rail. Most rail systems provide top and side channels for mounting the bracket with bolts also supplied with the mounting system. The most common bolt is a T-bolt and this often is the same bolt for top and side channels. 10/2016 1/7

The top-mounting channel design of the multi-string mounting bracket mimics commonly used microinverter or optimizer (aka, MLPE device) brackets. Thus this bracket will also fasten to most rail top channels just like MLPEs with similar bracketing. However, the RSB is generally taller than MLPEs which may preclude attachment under a module. Figure 3: A generic rail system demonstrates typical top and side channels for mounting bolts Even proprietary rail systems should work if their bolting method also works for MLPE devices, as seen at right in this SnapN Rack rail system. Height Matters The ability to fasten to the top or side of a rail is inconsequential if the RSB doesn t fit under the module or along the side of the array. Most rail-based systems are height-adjustable but that s no guarantee of a fit under the array. Some L-feet are not that tall or adjustable, leaving insufficient room height-wise. This results in the top bracket sitting above the top rail or at least the RSB touching the roof. To avoid this, make sure the dimension from roof face to top of the rail is equal to or greater than the following: RSB Model & Rail Height Single-string: 4.0 (10.2 cm) Multi-string: 4.5 (11.4 cm) Figure 4: SnapN Rack s snap in bolting device works in both its top and side rails. If the height adjustment means provided by the racking system is insufficient, consider third party products: (1) substituting with a third-party L-foot with greater height (e.g., EcoFasten Solar Compression Brackets) (2) or mounting the footing atop a third-party stanchion (e.g., ProSolar FastJack, Quick Mount PV QBase ) will provide greater clearance. 10/2016 2/7

Figure 5: the bracket is in contact with the rail top, but the RSB is touching the roof. Therefore, the RSB needs to be raised by either adjustable attachment to the side rail or by raising the rail itself. Rail-less System While rail-based systems are commonly used, rail-less systems are gaining in popularity. The stanchions used to support and connect adjoining modules often provide a top channel. However, an additional stanchion would likely be required to provide complete support. This necessitates an additional roof penetration. Some manufacturers include hardware for attaching boxes (e.g. stanchion bracket from Equilibrium Solar) but they will likely not fit the RSB footprint or attachment points. So you may need to devise a solid method or just use an attachment method that is independent of the racking system. Figure 6: for rail-less systems without hardware for attaching junction or combiner boxes, consider adding another stanchion; if this is not acceptable, consider mounting the RSB directly to the roof (see below). 10/2016 3/7

Racking Independent Mounting An installer can bypass the hardware limits of their array mounting system if they attach the RSB with a method independent of the array racking. The RSB may be mounted atop certain stanchions (standoffs) or directly to the roof deck with deck screws and approved sealant (or roof flashing). Examples are provided below but other manufacturers may offer similar solutions. Stanchion / Base Mounting e.g. Roof Tech The mounting bracket can be affixed to some stanchions/stand offs/bases. For example, Roof Tech, a rail-less racking manufacturer, provides a mounting base for which they have offered a fast and simple RSB attachment to asphalt shingle or metal roofing (see figure 7). Analogous solutions can be devised using other stanchions or standoffs or bases (see figures 8 & 9). Figure 7: The Roof Tech [E] Mount AIR Base: RSB bracket attached to the top of AIR base plus [E] mount Shims. The standard Roof Tech [E] mount is used as an EMT conduit support. 10/2016 4/7

Figure 8: Example of a stand-off with rail section. Figure 9: S-5! has a variety of raised metal seam attachment solutions with a generic rail 10/2016 5/7

Direct Roof Mounting If none of the prior solutions are available, the local AHJ may approve direct mounting of the RSB box to the roof surface. Consider using stainless deck screws and approved sealant (e.g. butyl tape or flashing sealant) following roofing codes and best practices. Use the same mounting holes as shown in Figure 2. If you have any questions about this or if you want to learn more about our solar solutions, do not hesitate and contact us at (219)734-5500 or PV-Support-USA@Fronius.com. We are happy to help you! 10/2016 6/7

Appendix A NEC 2017 References The Fronius Rapid Shutdown Box (RSB) may be mounted under the array as direct access to the RSB or integrated DC disconnect is not needed as the NEC code states: Section 690.15 Disconnection of Photovoltaic Equipment. Isolating devices shall be provided to isolate PV modules, ac PV modules, fuses, dc-to-dc converters inverters, and charge controllers from all conductors that are not solidly grounded. An equipment disconnecting means or a PV system disconnecting means shall be permitted in place of an isolating device. Where the maximum circuit current is greater than 30 amperes for the output circuit of a dc combiner or the input circuit of a charge controller or inverter, an equipment disconnecting means shall be provided for isolation. Where a charge controller or inverter has multiple input circuits, a single equipment disconnecting means shall be permitted to isolate the equipment from the input circuits. Informational Note: The purpose of these isolating devices are for the safe and convenient replacement or service of specific PV system equipment without exposure to energized conductors. (A) Location. Isolating devices or equipment disconnecting means shall be installed in circuits connected to equipment at a location within the equipment, or within sight and within 3 m (10 ft.) of the equipment. An equipment disconnecting means shall be permitted to be remote from the equipment where the equipment disconnecting means can be remotely operated from within 3 m (10 ft.) of the equipment. Section 690.34 Access to Boxes: Junction, pull, and outlet boxes located behind modules or panels shall be so installed that the wiring contained in them can be rendered accessible directly or by displacement of a module(s) or panel(s) secured by removable fasteners and connected by a flexible wiring system. 10/2016 7/7