Manifold Mounted Miniature Cartridge Valves -Way & 3-Way Direct Acting Miniature Cartridge Valves General Description: The manifold mounted miniature Cartridge Valve is offered in twoand three-way models with a stainless steel body. It offers a space-saving approach, with no manifold orifices to machine or press in, since the orifice is integral to the cartridge valve. Ultimately, less machining means lower manifold costs. These cartridge valves come fully assembled with no loose parts the sleeve, plunger, spring and orifice are pressed together as one unit. Installation Valves can be mounted in any position. The preferred orientation is with the coil vertical and upright. Standard Materials of Construction Please refer to page D8. Compatible Fluids Lubricated Gases, Water, Oil (300 SSU) and additional fluids compatible with materials of construction. Use of non-lubricated gaseous media can affect valve life. Electrical Characteristics: Standard Voltages: AC 4/60 0/60 0/50 40/60 0/50 DC, 4 For other voltages consult factory Coil Classification: Class F standard Class H available AC & DC coils are interchangeable on the same pressure vessel. Agency Approvals: Standard valves with NEMA 4X are C-UL-US Listed or Recognized. For additional details, consult factory. Maximum Ambient Temperature 35 F (AC)/5 F (DC) In absence of moisture, applications at temps as low as -0 F are possible. Please refer to page D8 for details. Applications: Analyzers and diagnostic equipment Medical and dental equipment Beverage dispensing and vending machines Humidification and misting equipment Pneumatic positioning Automatic dispensing equipment Irrigation equipment Instrumentation panels Lubrication equipment Refrigerant reclaim Automotive diagnostics/service 800 85 8305 ( 800 Valve05) D3
-Way Small Direct Acting - Normally Closed - Stainless Steel NPT Orifice in. Flow Factor Operating Differential Min. Gas Water Oil Watt Vessel Number Coil Valve AC TECHNICAL SPECIFICATIONS CONTINUED /8 3/64 0.06 0 950 950 950 8.5 40 FKM 09CL5EV4 9 D /8 /6 0.0 0 65 65 65 8.5 40 FKM 09CL5GV4 9 D /8 5/64 0.5 0 450 450 450 8.5 40 FKM 09CL5JV4 9 D /8 3/3 0. 0 30 30 30 8.5 40 FKM 09CL5LV4 9 D /8 7/64 0.8 0 45 45 45 8.5 40 FKM 09CL5MV4 9 D /8 /8 0.3 0 75 75 75 8.5 40 FKM 09CL5PV4 9 D /8 5/3 0.38 0 00 00 00 8.5 40 FKM 09CL5QV4 9 D DC TECHNICAL SPECIFICATIONS CONTINUED /8 3/64 0.06 0 390 390 390 8 40 FKM 09CL5EV4 9 D /8 /6 0.0 0 55 55 55 8 40 FKM 09CL5GV4 9 D /8 5/64 0.5 0 80 80 80 8 40 FKM 09CL5JV4 9 D /8 3/3 0. 0 30 30 30 8 40 FKM 09CL5LV4 9 D /8 7/64 0.8 0 00 00 00 8 40 FKM 09CL5MV4 9 D /8 /8 0.3 0 60 60 60 8 40 FKM 09CL5PV4 9 D /8 5/3 0.38 0 30 30 30 8 40 FKM 09CL5QV4 9 D -Way Small Direct Acting - Normally Open - Stainless Steel NPT Orifice in. Flow Factor Operating Differential Min. Gas Water Oil Watt Vessel Number Coil Valve AC TECHNICAL SPECIFICATIONS CONTINUED /8 /3 0.0 0 375 375 375 0 40 FKM 09FL5AV4 9 D /8 3/64 0.06 0 30 30 30 0 40 FKM 09FL5EV4 9 D /8 /6 0.0 0 50 50 50 0 40 FKM 09FL5GV4 9 D /8 5/64 0.4 0 05 05 05 0 40 FKM 09FL5JV4 9 D /8 3/3 0.0 0 80 80 80 0 40 FKM 09FL5LV4 9 D DC TECHNICAL SPECIFICATIONS CONTINUED /8 /3 0.0 0 375 375 375 8 40 FKM 09FL5AV4 9 D /8 3/64 0.06 0 30 30 30 8 40 FKM 09FL5EV4 9 D /8 /6 0.0 0 50 50 50 8 40 FKM 09FL5GV4 9 D /8 5/64 0.4 0 05 05 05 8 40 FKM 09FL5JV4 9 D /8 3/3 0.0 0 80 80 80 8 40 FKM 09FL5LV4 9 D D4 800 85 8305 ( 800 Valve05)
3-Way Small Direct Acting - Normally Closed - Stainless Steel Orifice In. Flow Factor NPT In Exh. In Exh. Min. AC TECHNICAL SPECIFICATIONS Operating Differential Gas Water Oil Watt Vessel Number Coil Valve /8 /3 /3 0.0 0.0 0 50 50 50 0 40 FKM 309CL5AV4 9 D /8 3/64 3/64 0.05 0.05 0 00 00 00 0 40 FKM 309CL5EV4 9 D /8 /6 /6 0.09 0.0 0 30 30 30 0 40 FKM 309CL5GV4 9 D /8 5/64 5/64 0.5 0.4 0 90 90 90 0 40 FKM 309CL5JV4 9 D /8 3/3 3/3 0.9 0.0 0 75 75 75 0 40 FKM 309CL5LV4 9 D /8 7/64 3/3 0.5 0.0 0 50 50 50 0 40 FKM 309CL5MV4 9 D /8 /8 3/3 0.3 0.0 0 40 40 40 0 40 FKM 309CL5PV4 9 D /8 5/3 3/3 0.38 0.0 0 5 5 5 0 40 FKM 309CL5QV4 9 D DC TECHNICAL SPECIFICATIONS /8 /3 /3 0.0 0.0 0 50 50 50 8 40 FKM 309CL5AV4 9 D /8 3/64 3/64 0.05 0.05 0 00 00 00 8 40 FKM 309CL5EV4 9 D /8 /6 /6 0.09 0.0 0 30 30 30 8 40 FKM 309CL5GV4 9 D /8 5/64 5/64 0.5 0.4 0 90 90 90 8 40 FKM 309CL5JV4 9 D /8 3/3 3/3 0.9 0.0 0 75 75 75 8 40 FKM 309CL5LV4 9 D /8 7/64 3/3 0.5 0.0 0 50 50 50 8 40 FKM 309CL5MV4 9 D /8 /8 3/3 0.3 0.0 0 40 40 40 8 40 FKM 309CL5PV4 9 D /8 5/3 3/3 0.38 0.0 0 5 5 5 8 40 FKM 309CL5QV4 9 D 3-Way Small Direct Acting - Normally Open - Stainless Steel Orifice In. Flow Factor NPT In Exh. In Exh. Min. AC TECHNICAL SPECIFICATIONS Operating Differential Gas Water Oil Watt Vessel Number Coil Valve /8 /3 /3 0.0 0.0 0 375 375 375 0 40 FKM 309FL5AV4 9 D /8 3/64 3/64 0.05 0.05 0 30 30 30 0 40 FKM 309FL5EV4 9 D /8 /6 /6 0.0 0.09 0 50 50 50 0 40 FKM 309FL5GV4 9 D /8 5/64 5/64 0.4 0.5 0 05 05 05 0 40 FKM 309FL5JV4 9 D /8 3/3 3/3 0.0 0.9 0 80 80 80 0 40 FKM 309FL5LV4 9 D DC TECHNICAL SPECIFICATIONS /8 /3 /3 0.0 0.0 0 375 375 375 8 40 FKM 309FL5AV4 9 D /8 3/64 3/64 0.05 0.05 0 30 30 30 8 40 FKM 309FL5EV4 9 D /8 /6 /6 0.0 0.09 0 50 50 50 8 40 FKM 309FL5GV4 9 D /8 5/64 5/64 0.4 0.5 0 05 05 05 8 40 FKM 309FL5JV4 9 D /8 3/3 3/3 0.0 0.9 0 80 80 80 8 40 FKM 309FL5LV4 9 D 800 85 8305 ( 800 Valve05) D5
3-Way Small Direct Acting - Universal - Stainless Steel Orifice In. Flow Factor NPT In Exh. In Exh. Min. AC TECHNICAL SPECIFICATIONS Operating Differential Gas Water Oil Watt Vessel Number Coil Valve /8 /3 /3 0.00 0.00 0 00 00 00 0 40 FKM 309UL5AV4 9 30 /8 3/64 3/64 0.050 0.050 0 50 50 50 0 40 FKM 309UL5EV4 9 30 /8 /6 /6 0.090 0.00 0 00 00 00 0 40 FKM 309UL5GV4 9 30 /8 5/64 5/64 0.50 0.40 0 70 70 70 0 40 FKM 309UL5JV4 9 30 /8 3/3 3/3 0.90 0.00 0 50 50 50 0 40 FKM 309UL5LV4 9 30 /8 7/64 3/3 0.50 0.00 0 40 40 40 0 40 FKM 309UL5MV4 9 30 /8 /8 3/3 0.30 0.00 0 30 30 30 0 40 FKM 309UL5PV4 9 30 /8 5/3 3/3 0.380 0.00 0 0 0 0 0 40 FKM 309UL5QV4 9 30 DC TECHNICAL SPECIFICATIONS /8 /3 /3 0.00 0.00 0 00 00 00 8 40 FKM 309UL5AV4 9 30 /8 3/64 3/64 0.050 0.050 0 50 50 50 8 40 FKM 309UL5EV4 9 30 /8 /6 /6 0.090 0.00 0 00 00 00 8 40 FKM 309UL5GV4 9 30 /8 5/64 5/64 0.50 0.40 0 70 70 70 8 40 FKM 309UL5JV4 9 30 /8 3/3 3/3 0.90 0.00 0 50 50 50 8 40 FKM 309UL5LV4 9 30 /8 7/64 3/3 0.50 0.00 0 40 40 40 8 40 FKM 309UL5MV4 9 30 /8 /8 3/3 0.30 0.00 0 30 30 30 8 40 FKM 309UL5PV4 9 30 /8 5/3 3/3 0.380 0.00 0 0 0 0 8 40 FKM 309UL5QV4 9 30 Arrangement -Way normally closed -Way normally open Arrangement 3-Way normally closed 3-Way normally open 3-Way universal over seat body flow over seat body flow common under seat body flow sleeve - - 3 under seat body flow exhaust NC sleeve 3 exhaust 3 3 NO Product Features: Space saving approach Less manifold machining means lower manifold cost No manifold orifices to machine or press in Cartridge valves are 00% tested Easy to assemble and disassemble with a 5/3" hex wrench to a torque of 5-35 in-lbs. Available with all coil options from Chart 9 in coil section. D6 800 85 8305 ( 800 Valve05)
Valve D 5/3 HEX -Way Normally Closed (09CLxx).94 3/4-4 UNS-A TH'D.54 WAY NORMALLY CLOSED Manifold cavity for 3/4-4 UNS-B thread per VMR-046 (See page D8) Valve D B.65 PORT 3 3/4" HEX.30.3 -Way Normally Open (09FLxx) 3-Way Normally Closed (309CLxx) 3-Way Normally Open (309FLxx) 3-Way Universal (309ULxx).54 PORT 4 PLC'S.74 PORT Manifold cavity for 3/4-4 UNS-B thread per VMR-046 (See page D8) 3/4-4 UNS-A TH'D. ALL DIMENSIONS REFERENCE ONLY. MANIFOLD CAVITY FOR 3/4-4 UNS-B THREAD PER VMR-046 3. REF VALVE NUMBERS 09XL5XX4B4X & 309XL5XX4B4X. 800 85 8305 ( 800 Valve05) D7
-Way Miniature Direct Acting Cartridge Mounted Valve Materials of Construction** Product* Wattage Type Body Tube Stop Flange "Plunger Blank" Plunger Spring Shading Ring Ambient 09CL5 8.5 (AC) WNC - 303SS 304SS 430FR 430FR 430FR 8-8SS Copper 35 F 09CL5 8 (DC) WNC - 303SS 304SS 430FR 430FR 430FR 8-8SS Copper 5 F 09FL5 0 (AC) WNC /8 303SS 304SS 430FR 430FR 430FR 8-8SS Copper 35 F 09FL5 8 (DC) WNC /8 303SS 304SS 430FR 430FR 430FR 8-8SS Copper 5 F * Shows the first 6 digits of the pressure vessel part number. ** Maximum ambient temperature shown is the rating when valve is operating at the maximum fluid temperature as shown in the product sections for each of the valves in this catalog. 3-Way Miniature Direct Acting Cartridge Mounted Valve Materials of Construction** Product* Watt Type Body Tube Stop Flange "Plunger Blank" Plunger Spring Shading Ring Ambient 309CL5 0 (AC) 3WNC /8 303SS 304SS 430FR 430FR 430FR 8-8SS Copper 35 F 309CL5 8 (DC) 3WNC /8 303SS 304SS 430FR 430FR 430FR 8-8SS Copper 5 F 309FL5 0 (AC) 3WNO /8 303SS 304SS 430FR 430FR 430FR 8-8SS Copper 35 F 309FL5 8 (DC) 3WNO /8 303SS 304SS 430FR 430FR 430FR 8-8SS Copper 5 F 309UL5 0 (AC) 3WU /8 303SS 304SS 430FR 430FR 430FR 8-8SS Copper 35 F 309UL5 8 (DC) 3WU /8 303SS 304SS 430FR 430FR 430FR 8-8SS Copper 5 F * Shows the first 6 digits of the pressure vessel part number. ** Maximum ambient temperature shown is the rating when valve is operating at the maximum fluid temperature as shown in the product sections for each of the valves in this catalog. VMR-046 A Cavity Dimensional Drawing.550 MIN R.00 MAX.75 MIN TH'D DEPTH.359 R.030 45 DETAIL B SCALE 4 : 3/4-4 UNS-B TH'D TO DEPTH SHOWN A.38 +.00 -.000 E n.70 MINOR DIA REF n.768 `.00 C.085 TO INT D C.00.00 D 5 Ø.56 DR MAX n.5 DR PLC'S 5 DEPTH OF.56 DR DEPENDS ON MANIFOLD DESIGN FOR PORT #. (UNDER SEAT) 63 A MACHINED SURFACE OF IS ACCEPTABLE IF THE MACHINED 4 SURFACE HAS A CIRCULAR LAY. B 3. MANIFOLD MOUNT VALVE MUST BE IDENTIFIED WITH A LABEL WITH VMR-046 REV X. 4 3 B SECTION A-A SCALE : 60 n.354 n.33`.00 4 3 DETAIL C SCALE 4 : D DEPTH OF.5 DR DEPENDS ON MANIFOLD DESIGN FOR PORT. (OVER SEAT) DIAMETER AND SURFACE FINISH MUST BE MAINTAINED TO DEPTH SHOWN. Warning: Please contact factory for the latest version of this cavity drawing before proceeding with any manifold machining. D8 800 85 8305 ( 800 Valve05)