GDS. Pole Mounted Disconnectors Up to 52kV

Similar documents
Power IT Pole Mounted Switch Disconnector, NPS. 630 A, up to 36 kv

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

TYPE BLT DISCONNECT SWITCHES

Medium Voltage Products Table Of Contents

GROUP D. Switch & Protective device.

Rapier AX Air Break Switch Disconnector. engineering brilliant solutions

TECHNOLOGY REVIEW. NPS Modular outdoor switch-disconnectors

NPS modular outdoor switch-disconnectors

Typical installations of the NPS modular outdoor switch disconnector

Outdoor load disconnectors Fla 15/97 GB. three-pole design rated voltage 25 kv rated current 630 A

Varius SUMMARY OF MODELS

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

SF6 LOAD BREAK SWITCH. Remote Controlled OCR TELE_1_2013.EN

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Varius SUMMARY OF MODELS

Section 2 - Substation Switchgear

Zinc Oxide Surge Arrester PEXLIM Q

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

Varius SUMMARY OF MODELS

Motorized switch-disconnectors OTM 40 to 125 Amperes

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

MEDIUM VOLTAGE DISCONNECTOR SWITCHES for indoor installation

Medium Voltage Products Table Of Contents

Disconnectors and earthing switches up to 25 kv AC

NRB Disconnector for outdoor installation

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Fuse switch-disconnectors

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

Fuse switch-disconnectors

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp)

Medium Voltage Outdoor Apparatus Portfolio 2009

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Hand operated drives and accessories. for outdoor switching devices

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications


HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Power IT Compact Secondary Substations, CSS. Low Voltage Switchboard, LVS2

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Change-over Disconnectors HUVS Range 12kV (630 to 6300Amp)

PRODUCT CATALOGUE. Overhead System

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Indoor disconnectors ITr. single- and three-pole design rated voltage 12, 25 and 38.5 kv rated current A

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

Gas Insulated Switchgear

Outdoor vacuum breaker for railway applications - FSK II

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

BRACKETS, MOUNTS & HARDWARE

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

vertical fuse switch disconnectors

Benefits, typical uses

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

power pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3

MEDIUM VOLTAGE SWITCHGEAR

Outdoor load disconnectors DRIBO Flc GB. three-pole design rated voltage 25 and 38.5 kv rated current 630 A

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

MOULDED CASE CIRCUIT BREAKERS BC160N

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

M-Force three-phase switch

Air-insulated switchgear UniGear type ZS1

Content. Uniswitch. 1. Design philosophy Applications Switchgear construction Cubicle types... 9

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SD Series Non-Fused Load Switches

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

Product Group Brochure. PS Range Capacitor Vacuum Switches

S&C Loadbuster Disconnects

Transformer bushings, type GOH. Technical guide

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

MEDIUM VOLTAGE NETWORKS

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2

Horizontal center break disconnector Type SDF, up to 550 kv Maximum reliability and minimal maintenance

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

Vistop TM isolating switches 63 to 160A

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Catalog 14A January 2013

Vacuum Circuit Breaker

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

with Vacuum Circuit Breaker HAF

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Disconnect & ByPass Switches

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

25A 25A 32A 40A 40A 63A 63A 80A

43-SDMS-04 REV. 00 SPECIFICATIONS FOR

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

LINOCUR Size D02 63A 230VAC/440VAC

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Power IT Air Insulated Cubicle Uniswitch

Surge arrester POLIM-H..SD

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

Transcription:

GDS Pole Mounted Disconnectors Up to 52kV

General Information The switch for every application The GDS range is a modern switch system with components for different isolation and switching applications in overheadlines and substations. The system is characterised by a high degree of flexibility in order to meet different national standards as well as to meet various customer specifications. The base in the switch system is the phase element. To this component can different accessories be added for having the requested disconnector or switch specification. The switch can be installed in all different pole types, wood, concrete, steel poles or substation structures. Different insulator alternatives The GDS can be supplied with a wide range of different insulators in order to meet different isolation philosofies, enviromental conditions and different standards. The components of the switch system allow for different insulators to be used due to the design with parallel insulators without affecting the base and contact components. As standard can porcelain, outdoor epoxy resin and silicon rubber insulators be offerd. Beside the standard material can also insulators according to customer specifications be used. 2

Technical characteristics Charctersistic Value Applicable standards IEC 62271-102, IEC 60265 voltage 24kV 36kV Impulse withstand voltage Phase-Earth 125kV 170kV Impulse withstand voltage over isolating distance 145kV 195kV Power frequency voltage 1 min wet, Phase-Earth 50kV 70kV Power frequency voltage 1 min wet, over isolating distance 60kV 80kV frequency 50-60Hz 50-60Hz current *) 630A 630A Short time current 25kA 25kA Duration of short time current 3 sec. 3 sec Peak withstand current 62,5kA 62,5kA Making capacity 5kA 3kA Interupting capacity with the loadbreak heads of mainly active load at rated voltage and cosφ=0,7 Interupting capacity with the loadbreak heads of mainly active load at rated voltage and cosφ=0,15 capacitive Interupting capacity with the loadbreak heads of mainly active load at rated voltage and cosφ=0,15 reactive Ringinterupting capacity with the loadbreak heads of mainly active load at rated voltage and cosφ=0,3 reactive Interupting capacity with breaking whip of mainly active load at rated voltage and cosφ=0,7 Interupting capacity with breaking whip of cable and line changing currents at rated voltage 630A 25A 16A 400A 25A 15A 400A 16A 4A 400A 16A 10A Permissible ice load Mechanical endurance Temperature range Insulator material Insulator creepage distance Up to 20mm >2000 operations -50 o C to +50 o C Porcelain,Silicon rubber, Outddoor epoxy resin Various for different insulators *) 630A is standard value. Alternative current ratings are 800A, 1250A and 2000A. 3

Phase elements No.** Insulator material voltage current Weight, kg 2862003 GP2G Outdoor epoxy resin 24kV 630A 30 A6737 GP2P Porcelain 24kV 630A 33 A7513 GP2G4 Outdoor epoxy resin 36kV 630A 33 A7332 GP2S Silicon rubber 36kV 630A 36 A7598 GDS36/52-6600 Porcelain 52kV 630A 60 A8268 GDSS26/52-6600 Silicon rubber 52kV 630A 54 *) 630A is the standard current rating. Other rated currents available on request **) Numbers are for sets of three units GP2G GP2P GP2G4 GP2S GDS36/52-6600 GDSS36/52-6600 4

Loadbreaking accessories Breaking whip No.* voltage For Phase element type Weight, kg 2862006 GBGK1 12-36kV GP2G,GP2P,GP2S,GP2G4 2,5 GBGK1 Loadbreak head No.* voltage For Phase element type Weight, kg A6733 GLBD1 12-24kV GP2G,GP2P,GP2S,GP2G4 12 A6733-2 GLBD2 36kV GP2S, GP2G4, GDS36/52-6600, GDSS36/52-6600 12 GLBD *) Set of three 5

Connecting accessories Extension part No.** Insulator material voltage current For Phase element type Weight, kg 2862011 GF2G Outdoor epoxy resin 24kV 630A GP2G 18 A6729-2 GF2P Porcelain 24kV 630A GP2P 20 A6729-5 GF2G4 Outdoor epoxy resin 36kV 630A GP2G4 20 2862009 GF2S Silicon rubber 36kV 630A GP2S 19 GF2G Extension Part for integrated surge arrester No.** Height of surge arrester current For Phase element type Weight, kg 2862123 GF2PI* 630A 5821934 GF2PI1* 630A **) Surge arrester is not included in articel number GP2G,GP2P, GP2S GP2G,GP2P, GP2S 15 15 GF2PI 6

Connecting accessories Cable connection Part No.** Insulator material voltage current For Phase element type Weight, kg 2862016 GK2G Outddor epoxy resin 24kV 630A GP2G 22 A6732-2 GK2P Porcelain 24kV 630A GP2P 23 A6732-5 GK2G4 Outdoor epoxy resin 36kV 630A GP2G4 23 2862014 GK2S Silicon rubber 36kV 630A GP2S 23 GK2G Cable connection Part for integrated surge arrester No.** Height of surge arrester current For Phase element type Weight, kg 2862124 GK2PI* 630A GP2G,GP2P, GP2S 14 **) Surge arrester is not included in articel number GK2PI 7

Fuse combinations For RP33 type fuse tubes No.** Insulator material voltage current For Phase element type Weight, kg 2862037 GS3G Outddor epoxy resin 24kV 80A GP2G 21 A6741-2 GS3P Porcelain 24kV 80A GP2P 22 2862035 GS3S Silicon rubber 24kV 80A GP2S 22 GS3G assembled on GP2G For fuses with dimensions according to DIN 43625 No.** Insulator material voltage current For Phase element type Weight, kg 2862071 GS5RG Outddor epoxy resin 24kV 20A GP2G 23 2862069 GS5RS Silicon rubber 24kV 20A GP2S 24 GS5Rs assembled on GP2S 8

Connecting accessories Hinge terminal bar and connection bars No. Weight, kg GPK A6530* GPK 3 A7997 CPAU 0,2 A7335 CSP 0,4 Cable connection bar CPAU CSP No. Weight, kg A6847* GCCB 2,4 GCCB Connecting clamps No.* Conductor crossection Weight, kg 2862056 GKG16 Al 16-120mm 2 0,8 EKN1 2862057 GKG43 Al 50-240mm 2 1 2862058 GKG44 Al 16-120mm 2 Cu 10-95mm 2 0,8 A3037 EKN1 Cu 10-120mm 2 0,4 GKG *) number is for set of three 9

Overvoltage protection accessories Spark gaps No.** Placement For Phase element type Weight, kg 5221927 GHG Horizontal over support insulator GP2G, GP2P 0,5 A6951 GSG1 Horizontal with crossarm bracket GP2G,GP2P, GP2S,GP2G4 10,5 GHG GSG1 10

Overvoltage protection accessories Surge arrester brackets No.* Placement Weight, kg 2862121 GSAB Attached to base of phaseelement or accessorie 4 2862120 GVP Together with crossarm clamp GRF 3 *) number is for set of three GSAB GSAB on cable connection part GVP on crossarm clamp GRF GSAB on phase element GVP 11

Earthing accessories No.** Placement For Phase element type Weight, kg A7681 EB2 Fixed contact side of phase element GP2G, GP2P 15 A7998 EB3 Fixed contact side of phase element GP2S,GP2G4 16 A8062 EB4 Rocking contact side of phase element GP2G, GP2P 15 A8034-1 GIL6 Mechanical interlock when earth blades installed on both sides of phase element - 2 A3500*) JOPO Earth bolt for connection of portable earthing tool All types 1 A6906 GJP Earth contact for rocking insulator. When disconnector opens, rocking insulator gets earth connected automatically GP2P,GP2G,GP2S 7 *) number is for set of 6 pcs **) numbers include three earth blades with mechanical interlock. Associated equipment such as phase coupling tubes, operating rods, operating handles must be ordered separately. EB4 EB2 GJK JOPO 12

Handoperating Mechanisms GHM Operating handles No. Indication label Weight A6731 GHM I-0 4 A6941 GHM2 ON-OFF 4 A6941-J GHM2-J* Earth On-Earth Off 4 A6941/AU GHM/AU** ON-OFF 4 A8215 GHMEI*** I-0 10 *) The GHM2-J are assembled for reversed operation direction **) The A6941/AU has flexible copper leads between the pole bracket and handle ***) Handoperating mechanism with electrical interlock. When ordering indicate voltage for the locking magnet GHMEI Auxillary contacts and accessories No. Comment Weight A7460 GHMSK 1NO+1NC contact 0,4 A8216 GHMDI 1NO+1NC x2 1 A7459 GHMIV* Interlocking wheel with one slot 0,2 A7459-1 GHMIV-1* Interlocking wheel with double slots 0,2 *) Castell interlocks are not included with the interlocking wheel, but can be supplied on request GHMSK Installed on GHM GHMDI Installed on GHM GHMIV Installed on GHM 13

Handoperating Mechanisms Hookstick operating mechanism GHS1 No. Weight A7380 GHS1 8 The GHS1 has a automatic resetting of the latchpin when operated. Accessories No. Comment Weight A8327 GHSSL Stickoperated safety lock attachment 0,5 14

Operating rods with accessories Operating rods No. Description Length,mm 2862032 A7435 Complete rod set with upper and lower rod.telescopically adjustable length Complete rod set with upper and lower rod.telescopically adjustable GMR1 5800-7600 GMR2 7300-9100 A7352-1 Upper operating rod with fork for connection to the operating lever GMR3 3250 A7352-2 Intermediate operating rod GMR4 3250 A7352-3 Lower operating rod with telescopically length adjustable section GMR5 2000-3800 A7373 2862034 Telescopical rod set with forks in both ends for connection to hookstick operating mechanism Extension rod with coupling socket for operating rods. Including one extra rod guide GMR6 2000-3800 GFR2 2000 A8174 Complete operating rod for substation disconnectors GMR17 3500-5300 GMR6 Operating rod accessories No. Suitable for crossarm Weight A6734 GMK Operating lever 1 A7635 GMK5 Operating lever for earth blades 1 A6742 GSI Rod insulator up to 24kV 0,5 A7550 GSI2 Rod insulator up to 52kV 1,3 A7354 GRC Rod coupling socket 0,3 A6743 GSS Rod guide 0,7 A7944 GSS2 Rod guide 2,5 GMK GMK5 GSI GRC GSS GSS2 15

Pole assembling crossarms Crossarms No. Dimensions Weight 5821911 GFLR1 80x80x2000 19kg 5821912 GFLR2 100x100x2000 25kg A6611-21 GFLR21 100x100x2500 31kg A8000 GFLR24 80x80x2400 22kg Note: The GFLR24 Crossarm have no holes drilled Crossarm assembling parts For single-pole installation No. Suitable for crossarm Weight 5821919 GFLRME GFLR1&GFLR2 4 A8139-1 GFLRME-1 GFLR21 4 No. Suitable for crossarm Weight A7962 PBRC GFLR1,GFLR2, GFLR21, GFLR24 7 Note: The PBRC pole bracket should not be used when conductors are terminated to the crossarm. For H-pole installation No. Suitable for crossarm Weight 5821920 GFLRMP GFLR1,GFLR2, GFLR21 2 16

Crossarm assembling accessories Crossarm clamps No. Suitable for crossarms Weight 2862091 GRF1 Box tubes and C-channels with max dimensions100x130mm (WxH) 0,6 kg 2862092 GRF2 Box tubes and C-channels with max dimensions130x180mm (WxH) 0,7 kg A6915 GRF3 Angle channels with max dimensions 130x180 (WxH) 0,7 kg 17

Mast Head Loadbreaklswitch 24kV,630A Handle operation, epoxy resin insulators Component Qty Remark Phase element GP2G 1 Hinge Terminal bar GPK 1 Loadbreak head GLBD1 1 Phase coupling tube GMA16 1 Crossarm clamps GRF1 3 Operating lever GMK 1 Operating tube GMR2 1 Assembling crossarm GFLR1 1 Operating handle GHM 1 Rod guide GSS 2 Rod insulator GSI 1 Ordering number for the complete unit Crossarm assembling parts (to be ordered separately) A7535 Component Qty Remark Single pole assembling parts GFLRME 1 number 5821919 H-pole assembling parts GFLRMP 1 number 5821920 (pole distance 2000mm c/c) 18

Mast Head installed disconnector 24kV,630A With Hookstick operation, epoxy resin insulators Component Qty Remark Phase element GP2G 1 Hinge Terminal bar GPK 1 Breaking whip GBGK1 1 Phase coupling tube GMA20 1 Crossarm clamps GRF6 3 Operating lever GMK 1 Pole bracket PBRC 1 Bolts for pole not included Operating tube GMR16 1 Assembling crossarm GMA24 1 Telescopical oåperating rod GMR17 1 Hookstick operating mechanism GHS1 1 Resin operating tube - 1 Not supplied by Gevea Ordering number for the complete unit Ordering number for the complete unit, but with assembled loadbreakhaeds A8176 A8176/GLBD1 19

Vertical disconnector 24kV,630A With earth blades, epoxy resin insulators Component Qty Remark Phase element GP2G 1 Earth blade set EB4 1 Include mechanical interlock Breaking whip GBGK1 1 Phase coupling tube GMA16 2 Crossarm clamps GRF1 3 Operating lever GMK 1 Operating lever GMK5 1 Operating tube GMR2 2 Rod coupling socket GRC 2 Rod guide GSS 4 Operating handle for disconnector GHM 1 Operating handle for earth blade GHM2-J 1 Ordering number for the complete unit excluding assembling crossarm Ordering number for the complete unit including assembling crossarm and pole attacment accessories A8336-1 A8336 20

Masthead installed disconnector 24kV,630A assembled on square concrete pole 200x200mm Ordering No. A8099 A8099/LB Description Complete unit including crossarm and operating mechanism. With assembled breaking whips Complete unit including crossarm and operating mechanism. With assembled loadbreak head 21

Masthead installed disconnector 24kV,630A assembled in steel pole Ordering No. A8184/GBGK1 A8184 Description Complete unit including crossarm and operating mechanism. With assembled breaking whips Complete unit including crossarm and operating mechanism. With assembled loadbreak head 22

Substation installed loadbreakswitch 36kV,630A With earthblades, epoxy resin insulators Component Qty Remark Phase element GP2G4 1 Extension part GF2G4 1 Loadbreak head GLBD1 1 Phase coupling tube GMA25 2 Crossarm clamps GRF1 6 Operating lever GMK 1 For disconnector blade Operating lever GMK5 1 For eathblade Operating tube GMR17 2 Operating handle GHM2 1 For disconnector blade Operating handle GHM2-J 1 For earthblade Earth blade EB4 1 Includes mechanical interlock Connection palm CPAU 6 Ordering number for the complete unit A8137 23

AB GEVEA Box 12043 Tlf. +46 11 184800 S-600 12 Norrköping Fax. +46 11 182350 Sweden E -mail. Info@gevea.se www.gevea.se 24 Version 2010-02-10 Eng