PABS. AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS ANSI STANDARDS AN ALSTOM COMPANY

Similar documents
Condenser Bushings. OIL-TO-AIR - Oil-Impregnated Paper ANSI STANDARDS IEEE C AND IEEE C AN ALSTOM COMPANY

B kv Gas-insulated Substations

Transformer bushings, type GOH. Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

B kv T&D GAS INSULATED SWITCHGEAR

NXPLUS C Single busbar. Maintenance-free for lifetime

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

kv А

Bushings for High Voltage AC Applications

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

Transformer bushings, type GSA-OA Technical guide

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

1ZSE en, Rev. 9. Transformer bushings, type GSA-OA Technical guide

Transformer bushings, type GOA 250. Installation and maintenance guide

25 kv Apparatus Bushings

dfdf 34.5 kv and 69 kv, Type O Plus C II Condenser Bushings Technical Guide

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Current transformers. Outdoor operation SF 6 -gas insulated. JGF ( ) kv

OHB Outdoor sulphur Hexafluoride circuit-breaker

EMPAC Metal enclosed capacitor bank for wind applications

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

15 kv and 25 kv Thru-Bushings

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

1ZSC ABJ EN, REV. 1. Gas insulated wall bushings type GGFL Technical guide

Gas Insulated Metal-clad Switchgear, HMGS!

INSTRUCTION MANUAL CRS Combined insulation bushing

Transformer Bushings Type COT COT kv to 245 kv up to 3150 A IEC 137

OIL TO AIR BUSHINGS SERIES PNO. VOLTAGE FROM 52 kv TO 245 kv

MICAFIL RIP Transformer Bushings AirRIP / RTKF kv

3EQ Composite Housed Surge Arresters

DM Condenser bushings, kV DURESCA

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

GENERAL. CONSTRUCTION External

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability

Power Voltage Transformers for Air Insulated Substations

General information on handling and maintenance of SDC TM Solid Dielectric Capacitor Bushings

3 TM Cold Applied Barrier Boot System

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

3AP1 DTC for 145 and 245 kv

Combined instrument transformers

Independent Testing Laboratory for High Voltage Equipment

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Station Post Insulators

Inductive voltage transformers

Inductive voltage transformers

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

شركة كهرباء محافظة القدس المساهمة المحدودة

43-SDMS-04 REV. 00 SPECIFICATIONS FOR

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

Trip Circuit and Trip coil supervision Relay

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

Technical Specification For Outdoor Substation Harmonic Filter Banks

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

GROUP D. Switch & Protective device.

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

HVDC bushing without oil side porcelain Type GOF, for outdoor mounting. Installation and maintenance guide

Bushing Insulators according to DIN and UNEL Standards

Technical Specification for Pole Mounted Capacitor Rack

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Inductive voltage transformers

AIR CORE REACTORS. Phoenix Electric Corporation

voltage switchgear ZX ABB ZX Family 1

8DJ. Maintenance-free for lifetime

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

Technical Specification of GECOL. Packaged Transformers

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

DURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

Transcription:

PABS Air-to-SF 6 Bushings 7.5-800 kv BUSHINGS AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS 7 - ANSI STANDARDS AN ALSTOM COMPANY PABS bushings are gas-insulated types that meet IEC 7, ANSI/IEEE or other National Standards. They are designed for connection, in any ambient conditions, of GIS, GIL or Dead Tank Circuit Breakers to overhead transmission lines. According to the operating temperature, the gas used for filling is pure SF 6 or a mixture of SF 6 and N. The bushing is designated as follows: PABS.40.45..X PABS Gas-insulated bushings, air-to-sf 6 application 40 Insulation class in kv 45 BIL in kv Rated current in A Voltage and current ratings Standard rated voltage range, at /Hz, is: 7.5 kv to 800 kv for composite design 7.5 kv to 0 kv for porcelain design Standard rated current is 000 A through A, according to the rated voltage; it is possible to realize bushings up to 8000 A. For non-standard ratings, consult Passoni & Villa. Customer Benefits Bushings with longer lifetime and higher reliability Explosion and fire-proof design Non-aging internal insulation Installation in any position On line monitoring in service GRID

Main Features PABS: IEC and ANSI Standards gas-insulated bushings Range 7.5 to 800 kv High continuous withstand current up to 8000 A High short-circuit current up to 00 ka - s; 6kA-s Gas-insulated bushings with pure SF 6 or SF 6 -N mixture Non-aging internal insulation Air side: porcelain or composite insulator Standard design as coon gas zone with GIS/GIL Explosion and fire-proof design High quality sealing system and efficient gas leakage control: gas leakage less than 0.5% per year (usual 0.%) Installation in any position In-service monitoring of main gas insulation throught density (pressure) control Polyester-varnished aluminum flanges 4 5 Fig. : Section 6. HV Terminal. Top closing plate. Inner conductor 4. Porcelain/composite insulator 5. SF 6 gas zone 6. Internal shield 7. Flange 8. Transport cover 7 8

Design Standard bushing type PABS are designed with gas zone in coon with GIS/GIL or HV CB gas compartments. The accessories like filling plug, insulator support (barrier) and pressure relief device are at GIS/ GIL manufacturer care. Main internal insulation is pure SF 6 or a mixture of SF 6 /N at proper density (measured as gas pressure at 0 C - 68 F), while external insulation is provided by the high strength porcelain or composite insulator. Bushings up to and including 6 kv are designed with internal screen(s), while bushings at 40 kv and above are designed with internal semi-graded insulation made of gas-impregnated synthetic films (patent pending). This solution grants compact dimensions with more uniform internal/external electric field distribution. Fig. : Section of bushings up to 6 kv Fig. : Section of bushing at 40 to 800 kv (patent pending) Manufacturing All manufacturing procedures (certified to EN 900- ISO 900) comply with the Passoni & Villa Quality Assurance System and procedures. The manufacturing process for PABS bushings is shorter than oil-insulated bushings thanks to the lower sensitivity of SF 6 insulation to humidity and air presence. The assembling is made in a pure and unpolluted ambient in order to avoid internal insulation contamination. For bushings manufactured with porcelain envelopes, both sides of the porcelain are cemented to the metal flanges (see fig. 5). All cemented surfaces, potentially in contact with the external environment, are silicone sealed. For bushings manufactured with a composite insulator, the fiberglass tube is tightly glued to the metal flanges, and a unique silicon cast realizes the sealing and the sheds for the requested creepage distance. Before factory tests, bushings are treated under vacuum and then filled with gas at minimum operating pressure.. Internal shield. Flange. Transport cover. Composite (porcelain). Inner conductor. Condenser core 4. Flange 5. Transport cover Fig. 4: Particularities of the porcelain cemented to the flange 4 5 If required, all bushings, at 40 kv and above, can be equipped with a voltage tap and an associated voltage indicator. With the proper capacitance design, it is possible to achieve the low voltage U (few tens of volt) for indicators or measuring devices. Bushings at 40 kv and above can also be provided, with test tap for tan δ, capacitance and partial discharges quantity measurement. During service, if not used, voltage tap must be grounded by using the voltage tap cap.. Porcelain. Silicone sealing. Cement 4. Metal fitting 5. Silicone sealing 6. Flange 6 Terminals and conductor The cylindrical top terminal is made of aluminum or copper and is fixed to the upper closing plate. Different terminals, such as NEMA types, are available upon request. The main conductor is a central rod made of aluminum or copper according to the rated current. The bottom terminal connection to the GIS/GIL or CB is silver plated or copper plated. Its dimensions and shape are designed according to the customers request.

Air side The external insulator is made of brown porcelain, (grey upon request) with cemented flanges, or composite insulator (resin fiberglass envelope covered by silicone sheds) glued to the metal parts. This system offers high mechanical strength during normal and abovenormal service conditions. The alternating shed configuration (shortlong sheds) is the most effective solution and has been proven by salt spray tests. The shed profile complies with the new IEC 85 recoendations. Composite insulators are recoended for all Bushings from 45 kv through 800 kv, as it significantly improves bushing reliability throughout its lifetime. Other benefits include: better behavior against weather elements, such as pollution and rain, due to the hydrophobic property of silicon rubber high mechanical withstand in case of impact, shocks and/or vibrations during handling, transportation or in service, such as for seismic activity higher safety for personnel and equipment in case of an internal fault (explosion-proof design). Flange Dimensions, flange type and lower conductor terminals, are designed in order to match the dimensions of the GIS/GIL or CB conductor. For Dead-Tank Circuit Breaker installation, thoroidal cores for measurement and protection, according to ANSI/IEEE, IEC or other National Standards, are supplied on request. Fig. 5: Flange fixing holes (based on customer requirements) PABS CUSTOMER SIDE O-RING GASKET n holes øf ANTICORROSIVE PROTECTION Insulation The basic insulation is Sulphur-hexafluoride (SF 6 ), which is not poisonous no flaable and has good dielectric, arc-exstinguishing and thermal capabilities. These characteristics enables it to be widely used in MV and HV equipments. The insulation characteristic of SF 6 depends on the internal apparatus density and can be expressed in bar (PSI) at a temperature of 0 C (68 F). At approx. bar (4.5 PSI) SF 6 gas has the same dielectric strength as oil and several times higher than air. Fig. 6: SF 6 atomic model The main SF 6 insulating features are: non aging compressibility less sensitivity to humidity and air possibility of controlling the dielectric strength through the control of SF 6 gas density (pressure). Thanks to these characteristics, Air-to-SF 6 bushings have a long life and a very high service reliability. In case of very low ambient temperatures (down to -40 C/-40 F) a mixture of SF 6 and N is used. Gaskets The sealing system is of fundamental importance for any pressurized equipment. Specifically, it has to guarantee leakage of less than 0.5 % per year. For this purpose Passoni & Villa has a very severe regulation and tolerances concerning the choice, control and tests of gaskets and their grooves (i.e. material, resistence to high temperatures, ozone, radiation and other ambient contaminants that may influence the aging process of the gaskets). Our internal standards permit the leakage less than 0. % per year. O-ring type gaskets are made of EPDM which grants the usage in a wide range of temperatures: from -45 C to + C. With our double-gasket system, flange and grooves are lubricated with a special grease in order to guarantee the highest tightness and to prevent corrosive influences in severe ambient conditions. 4

Metal surface treatment Upon request, according to specific customer requirements, finishing or final painting can be provided. Tests Type and routine tests are performed according to the latest edition of IEC 7 or ANSI/IEEE Standards or other specific requirements. Important leakage tests assure service reliability. By measuring total leakage using a highly sensivity leak-meter ( Qm method in accordance with IEC 68--7/94) we guarantee a leakage of less than 0.5 % per year, but normally it is less than 0. %. Gas filling and refilling After the bushing is connected to the network and before energizing, it has to be vacuum treated together with the GIS/GIL or CB and then filled with gas. For filling, use pure SF 6 gas or a mixture of SF 6 and N according to the prescription of the Standards (IEC 78 or other National Standard). Fig. 7: Toroidal core fitted on the flange of the bushing In addition to routine and type tests prescribed by Standards, bushings from 40 kv through 800 kv are subjected to the Very Fast Transient (VFT) withstand tests. In order to verify the bushing electrical withstanf capability the bushing with semi-graded internal insulation is tested with lightning impulses chopped in SF 6, this simulating possible flashovers in GIS during its on-site tests according to IEC 67-0 standard. The repetition of type tests is performed in order to guarantee that the bushing has preserved all its characteristics after VFT tests. Packing - Transportation All bushings are protected with a plastic envelope and are horizontally transported in wooden cases. Bushings up to and including 70 kv are usually shipped in crates containing three pieces, while crates containing a single piece are used for higher voltages. During transportation, the lower part of the bushing is closed and protected by a transport cover which is used also for fixing the central conductor. Bushings at 40 kv and above are transported with a relatively small overpressure of dry nitrogen (0,-0, bar). The gas zone is filled through the automatic non-return valve.. Porcelain/composite. Toroidal. Flange 4. H.V.C.B. 4 5

PABS Bushings with porcelain and composite insulators Bushings with porcelain insulators Dimensions Nominal System Voltage KV 7.5 00 45 70 45 00 6 40 5 Rated line-to-earth voltage KV 4 58 7 84 98 4 7 09 4 8 BIL (Dry lightning impulse withstand voltage) KV 5 5 5 6 7 0 0 75 45 5 Dry and wet power frequency withstand voltage (for s) KV 40 0 0 75 5 4 4 50 6 675/70/740 Wet switching impulse withstand voltage KV - - - - - - 8 9 0 75 Rated continuous current (standard value) up to A 000 000 000 Rated thermal short-time current (s) KA 80 80 80 80 00 00 00 Rated dynamic current kap.5 x Ith Minimum operating pressure (abs.) Arcing distance (L) C (Creepage distance) Normal Cantilever load (test) up to () Heavy Cantilever load (test) up to () Approx. weight Max. operating altitude (asl) L0 L4 (max.) bar/mpa (PSI) N (lbf) N (lbf) kg (lb) m (ft) 0 (.6) 000 (4) (700) 90 (98.5) 88 (.4) 40 (9.45) 000 (4) 5 (5.5) 90 (.4) 0 (56) 5 (5.5) 90 (.4) 5 (5.5) 90 (.4) 4.0-6.5/0.04-0.065 (-95) 980 (78.0) Min. 5 /kv Min. 0.984 in/kv 5 (5.5) 90 (.4) 000 (8) 0 (5.) 0 (68.4) (.) 7 (.45) 40 (.8) 00 (86.6) (77.6) 05 (.0) 00 (.9) 40 (6.5) 7 (08.) 6 (4.0) (.) 00 (.9) 40 (6.5) Note: For non-listed ratings, please consult Passoni & Villa. D is variable according to the rated current. Flange dimensions (fig. 6) are based to customer requirements. 00 (9.9) 75 (590.4) 90 (.54) 9 (5.4) 09 (.6) 570 (.44) 7 (9.5) 80 (.8) (755.8) 90 (.54) 9 (5.4) 09 (.6) 570 (.44) 7 (9.5) 6

Bushings with composite insulators Dimensions Nominal System Voltage KV 7.5 00 45 70 45 00 6 40 5 800 Rated line-to-earth voltage KV 4 58 7 84 98 4 7 09 4 8 46 BIL (Dry lightning impulse withstand voltage) KV 5 5 5 6 7 0 0 75 45 5 00 Dry and wet power frequency withstand voltage (for s) KV 40 0 0 75 5 4 4 50 6 675/70/740 880/9 Wet switching impulse withstand voltage KV - - - - - - 8 9 0 75 45 Rated continuous current (standard value) up to A 000 000 000 Rated thermal short-time current (s) KA 80 80 80 80 00 00 00 00 Rated dynamic current kap.5 x Ith Minimum operating pressure (abs.) Arcing distance (L) C (Creepage distance) Normal Cantilever load (test) up to () Heavy Cantilever load (test) up to () Approx. weight Max. operating altitude (asl) L0 L4 (max.) bar/mpa (PSI) N (lbf) N (lbf) kg (lb) m (ft) 0 (.6) (700) (700) 70 (54.) 88 (.4) 85 (7.8) 80 (76.4) 05 (8.07) 80 (76.4) 05 (8.07) 80 (76.4) 05 (8.07) 80 (76.4) 05 (8.07) 4.0-6.5/0.04-0.065 (-95) 980 (78.0) Min. 5 /kv Min. 0.984 in/kv 90 (48.9) 000 (8) 0 (5.) 07 (.08) 7 (.45) 0 (.0) 00 (86.6) 0 (46.0) 95 (.6) 00 (.9) 0 (.0) 7 (08.) (77.6) (.) 00 (.9) 40 (6.5) Note: For non-listed ratings, consult Passoni & Villa. D is variable according to the rated current. Flange dimensions (fig. 6) are based on customer requirements. L0 00 (9.9) 40 (95.9) 70 (.76) 5 (.9) 09 (.6) 455 (7.9) 7 (9.5) L0 80 (.8) 0 (0.) 70 (.76) 5 (.9) 09 (.6) 455 (7.9) 7 (9.5) (98.6) 700 (54.) - 5 (.9) 4 (7.7) 60 (4.0) 00 (4.0) L C L C L C L C L L4 L5 D D D6 D L L4 L5 D D D D6 L L4 L5 D D6 D D L L4 L5 D D6 D D Fig. 8: Bushings with porcelain housing 7.5 to 6 kv Fig. 9: Bushings with composite housing 7.5 to 6 kv Fig. 0: Bushings with porcelain housing 40 to 5 kv Fig. : Bushings with composite housing 40 to 800 kv 7

Name plate Each bushing is provided with a name plate (fig. 6-7), with all the electrical data and serial number, in accordance with the prescriptions of IEC 7 and ANSI/IEEE Standards. The plate, made of stainless steel and fixed to the flange by rivets, includes: Fig. : Nameplates 9 PASSANTE-BUSHING-TRAVERSEE-DURCHFUHRUNG -Hz Fig. : Nameplates 0 4 5 INSULATED WITH MIN. SERVICE PRESSURE FILLING PRESSURE DESIGN PRESSURE AN ALSTOM COMPANY Alstom Grid Worldwide Contact Centre www.grid.alstom.com/contactcentre Tel.: +44 (0) 785 070 www.grid.alstom.com Kg 6 N kv MILAN I TA LY Following the acquisition of PASSONI & VILLA, Alstom Grid now offers a large portfolio of condenser bushings for AC or DC operation. If you require any further information, please address your queries to rpv@alstom.com A MILAN I TA LY BAR REL BAR REL BAR REL 8 7 To contact the manufacturer Viale Suzzani, 9 06 MILANO (Italy) Tel.: +9 0 66 Fax: +9 0 647 09 06 Email: rpv@alstom.com. Bushing type. Insulating voltage. Rated current 4. Max. mounting angle from the vertical 5. Weight 6. Drawing number 7. Serial number 8. Month - year of manufacturing 9. Gas used: pure SF 6 or SF 6 -N mixture percentages 0. Minimum service pressure (relative). Filling pressure (relative). Max. internal pressure (relative) GRID Grid-Products-L-PABS-7788-V-EN - Alstom, the Alstom logo and any alternative version thereof are trademarks and service marks of Alstom. The other names mentioned, registered or not, are the property of their respective companies. The technical and other data contained in this document are provided for information only. Neither Alstom, its officers nor employees accept responsibility for or should be taken as making any representation or warranty (whether express or implied) as to the accuracy or completeness of such data or the achievements of any projected performance criteria where these are indicated. No liability is accepted for any reliance placed upon the information contained in this brochure. Alstom reserves the right to revise or change these data at any time without further notice. Printed on paper made with pure ECF (Elemental Chlorine Free) ecological cellulose produced from trees grown in production forests under responsible management, and selected recycled three-layer fibres. 8