Intelligent LED Lighting Systems TM QUICK START INSTALLATION GUIDE ANALOG - INTELLIGENT POWER CENTER (IPC) LIGHTS & POWER: (Note all lights fixtures to be wired in series) 1) Identify dry, non-plenum location for IPC. Determine location & orientation of IPC and Break-Out Modules. Note: Vertical orientation of IPC is best for cooling. Make sure Analog zone inputs are visible and accessible. See page 6 of IPC specifications for optional acceptable orientations. 2) Run wires from the Break-Out Module locations directly to the fixture locations. 3) Mount IPC to board w/ #8 screws or self-tapping screws or in an approved enclosure. Use approved plenum enclosure if unit is located in plenum. 4) With typical 115Vac input, IPC consumes 2.7 amps. Standard 15 amp breaker can accommodate up to 4 IPCs and a 20 amp breaker can accommodate up to 5 IPCs. If wiring only 4 or 5 IPCs, consider powering from two separate circuits for redundancy. Note: 115Vac = 2.7 Amps, 240 Vac = 1.1 A & 227 Vac = 1.0 A. 5) Provide service disconnect switch for IPCs if not in close proximity to electrical panel or as required per code. 6) Provide line-voltage power to IPC and wire as specified on page 7 of IPC installation manual. (Black to Line, White to Neutral & Green to Ground.) 7) Select Master control or up to 4 zones of analog control. See Analog switch option diagrams. 8) Wire class 2 IPC wires to Break-Out Modules. See Detail B4.09, B4.12, B6.09 or B6.12. (Black is always Negative.) 9) Wire fixture home runs to the Break-Out Modules. See Detail B4.09, B4.12, B6.09 or B6.12. (Black is always Negative.) 10) Wire fixtures in series. Wire only two fixtures per channel, typ. See Detail A1 for wiring fixtures in series. 11) If not using Master zone control, track which fixtures are on which zones on a plan or chart. Note: For complete and more technical installation instructions refer to the LumaStream Intelligent Power Center Application and Installation Manual included with each unit. Rev. - 09.30.12 LumaStream.com 2887 22 nd Avenue N, Suite D, St. Petersburg, FL 33713 727.827.2805
18/2 MULTICONDUCTOR CABLE LED LED LED LED LED LED ZONE4 LED LED LED LED LED LED ZONE3 LED LED LED LED LED LED ZONE2 B6 BREAKOUT MODULE B3 BREAKOUT MODULE B3 BREAKOUT MODULE LED LED LED LED LED LED ZONE1 24 LED FIXTURES Low voltage toggle switches and/or 0-10V analog dimmers VIOLET VIOLET AC MAINS GRAY GRAY GRAY GRAY GROUND (GREEN) NEUT (WHITE) LINE (BLACK) ZONE 1 ZONE 2 ZONE 3 ZONE 4 Note: For the UP position to be ON, toggle switches must be installed upside down. When switch is closed, LED s are OFF. TITLE: DWG #: INDEPENDENT ZONE CONTROL USING SWITCHES AND/OR 0-10V DIMMERS WIR-ANA-001 REV: B
VIOLET GRAY 0-10V dimmer Leviton # IP710-DLZ Hunt # PS-LED-010 LINE (BLACK) AC MAINS GROUND (GREEN) NEUT (WHITE) LINE (BLACK) TITLE: DWG #: MASTER ZONE CONTROL USING 0-10V DIMMER & ON/OFF SWITCH WIR-ANA-002 REV: B
VIOLET GRAY VIOLET GRAY 1 Common 1 1 3-WAY LOW VOLTAGE TOGGLE SWITCH 2 Travelers (Brass Screws) 2 LOW VOLTAGE TOGGLE SWITCH OR 0-10V DIMMER 2 ZONE 1&2 TITLE: DWG #: MULTIPLE ZONE CONTROL USING TOGGLE SWITCH OR 0-10V DIMMER WIR-ANA-003 REV: B
TRINITY #1 TRINITY #2 TRINITY #3 ETC. VIOLET GRAY LOW VOLTAGE TOGGLE SWITCH AND/OR 0-10V DIMMER TITLE: MULTIPLE TRINITY MASTER CONTROL USING TOGGLE SWITCH AND/OR 0-10V DIMMER DWG #: WIR-ANA-004 REV: B
4 Inch Recessed New Construction LED Luminaire Installation Instructions OWNER/USER RESPONSIBILITIES: It is the responsibility of the contractor, installer, buyer, owner and user to install, maintain and operate this luminaire in accordance with all applicable laws, building codes, regulations and local Electrical Safety Authority requirements. This product is only to be installed by a qualified person. WARNING Shut OFF power at fuse box or circuit breaker before installation. Turn power OFF before inspection or removal of LED light source. Installation: 1. Pull on LED Trim Ring in direction shown to remove LED light source from housing. Flip open one lever on each Wire Lever Nut to disconnect wires. 2. Extend bar hangers to fit between joists. Bar hanger foot aligns with bottom of joist. Hammer pre-installed nails into joists. When installing in drywall, cut 4-1/2 hole. If necessary, adjust fixture for ceiling thickness by loosening hex screws then retighten. 3. Remove Junction Box cover. Remove appropriate knock-out and insert strain relief (not supplied) into hole. Flip open Wire Lever Nut. Connect Class 2 constant current source: Connect +Ve to RED. Connect Ve to BLACK, by inserting stripped wire into Wire Lever Nut. Close lever. OBSERVE CORRECT POLARITY. Failure to do so will damage LED light source. Replace Junction Box cover. 4. Re-connect LED light source to housing. Connect RED to RED, BLACK to BLACK. OBSERVE CORRECT POLARITY. Failure to do so will damage LED light source. Compress Flat Spring Clips with fingers and insert into housing opening. Press upwards until trim ring is flush against the ceiling. LumaStream, Inc. 2887 22nd Ave. N Saint Petersburg, FL 33713 T: 1-727-827-2805 Page 1 of 1 Disclaimer: LumaStream Inc. reserves the right to make changes without further notice to any products herein to improve reliability, function, or design. LumaStream does not assume any liability arising out of the application or use of any product described herein; neither does it convey any license under its patent rights, nor the rights of others. info@lumastream.com www.lumastream.com 2012 LumaStream, Inc. All Rights Reserved Doc No: 4.0 RI Installation Revision: Feb-22-2012
4 Inch Recessed Re-Model LED Luminaire Installation Instructions OWNER/USER RESPONSIBILITIES: It is the responsibility of the contractor, installer, buyer, owner and user to install, maintain and operate this luminaire in accordance with all applicable laws, building codes, regulations and local Electrical Safety Authority requirements. This product is only to be installed by a qualified person. WARNING Shut OFF power at fuse box or circuit breaker before installation. Turn power OFF before inspection or removal of LED light source. Installation: 1. Pull on LED Trim Ring in direction shown to remove LED light source from housing. Flip open one lever on each Wire Lever Nut to disconnect wires. 2. Cut 4-3/8 hole in ceiling. Pull Class 2 wiring through hole in ceiling. Remove Junction Box cover. Remove appropriate knock-out and insert strain relief (not supplied) into hole. Flip open Wire Lever Nut. Connect Class 2 constant current source: Connect +Ve to RED. Connect Ve to BLACK, by inserting stripped wire into Wire Lever Nut. Close lever. OBSERVE CORRECT POLARITY. Failure to do so will damage LED light source. Replace Junction Box cover. 3. Pass junction box up into hole in ceiling. Retract clips into housing and insert housing into ceiling. Press clips outwards to hold housing in place. To remove from ceiling, pull clips down and back into housing 4. Re-connect LED light source to housing. Connect RED to RED, BLACK to BLACK. OBSERVE CORRECT POLARITY. Failure to do so will damage LED light source. Compress Flat Spring Clips with fingers and insert into housing opening. Press upwards until trim ring is flush against the ceiling. LumaStream, Inc. 2887 22nd Ave. N Saint Petersburg, FL 33713 T: 1-727-827-2805 Page 1 of 1 Disclaimer: LumaStream Inc. reserves the right to make changes without further notice to any products herein to improve reliability, function, or design. LumaStream does not assume any liability arising out of the application or use of any product described herein; neither does it convey any license under its patent rights, nor the rights of others. info@lumastream.com www.lumastream.com 2012 LumaStream, Inc. All Rights Reserved Doc No: 4.0 RC Installation Revision: Feb-22-2012