PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Similar documents
SSR SSR SSR SSR

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Page 1 of 5 FL-4020 FLUORESCENT BALLAST CONTROLLER

MBDC V. 110VAC Input Brush DC Controller. User s Guide East Landon Drive, Anaheim, CA

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

PSX-240 Enclosed Autotransformer Installation Manual

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

MIL-24/2600Q MIL-24/3200DQ

OWNERS MANUAL JANUARY 2007 ISO

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

C3000 SIGNAL TRANSMITTER. Introduction

A6Z OPERATING MANUAL

BLWS23MDAxS-160 Offline Series 110VAC, 3A Brushless Controller / Motor

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

A1P OPERATING MANUAL

OWNERS MANUAL JANUARY 2007 ISO

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

ADI-125/750 ADI-125/1500 ADI-125/2500

SAVE THESE INSTRUCTIONS

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

A3Z OPERATING MANUAL

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

DC to AC Power Inverters

DC to AC Power Inverters

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

MDC VAC Input Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

Installation, Operation and Maintenance. VA(M)S24-27 (T)-T Series Actuator

CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

LEV/Wn Building A Connected World

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

SPC-PANEL Simplex, Single Phase Pump Control Panel

Thermaltake Warranty / Support Information

MLA Bipolar Microstep Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

MaxLite LED UTILITY WRAP FIXTURES

RU BMS Power Supply and Battery Management System Owners Guide

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

Installation Manual & Warranty

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

PEC 827E. 120 VAC AC Distribution Shelf. Critical Power Product Manual

RHINO MOTION CONTROLS

Installation and Operating Manual

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

DC REGULATED POWER SUPPLY

1000 Watt Pure Sine Wave Power Inverter, Users Manual

MBD Enhanced Step Motor Driver. User s Guide #L East Orangefair Lane, Anaheim, CA

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

TM4500. Track Mounted Step Motor Driver. User s Guide. CE Certified and RoHS Compliant #L010060

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Level One Electric Vehicle Charging Station Wall Mount Product Guide

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

PRO Dimmer INSTRUCTION MANUAL

FLO Home TM G5 Model. Installation guide

8460SRC Replacement Chassis for Scully ST-6 and Biclops Monitors

Installation & Operation Manual PWS1000R Rack Mount Power Supply

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

Pump Installation and Service Manual HRS Hydromatic Retractable System

INW Panel Meter Reading an INW PT12 Sensor

Dayton DC Motor Control

ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. User s Manual. Model LCS. With Isolation Monitor for 230VAC

Updated: October 2012

For a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.

SB SWITCH CONTROL BOX

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

PENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK

USER'S MANUAL MODEL DPD60001 MICROSTEP DRIVER PACK

Boston Gear Ratiotrol DC Motor Speed Control

WF-5110R True Sine Wave Inverter

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

A Member of the. Integrated Metering Technologies

OBE, OBEXU, ON BOARD Battery Chargers

6. Electrical. 7. Settings. 8. Quick

VTC610 Series Voltage Converter. Installation & Operation Manual

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Model GD-70D4A-XX Supplement to the GD-70D Operator s Manual

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

BMRX Series ROTARY LEVEL CONTROL

Preassembled Clutch/Electrically Released Brake Module

VTC1000 Series Voltage Converter. Installation & Operation Manual

Battery Back-up BBM Owner's Manual. Please read this manual BEFORE installing your inverter

INSTALLATION & OWNER'S MANUAL

Installation and Operation Guide for PD4100 Series Power Control Centers

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Addendum PAN-F / PAN-G / PAN-J

Transcription:

0-10V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V 4 circuit Analog 1-10V 4 x 4 A. Dimmer pack Serial Number Dimmers Indicators Digital Lighting Systems,Inc Info@digitallighting.com 1-305-969-8442 Made in USA USER'S MANUAL -UM

Load Driver Module Information User's Manual - Page 1 Figure 1 - PD404 LDM Detail Earth Ground H H N N N SSR1 SSR2 SSR3 SSR4 Table 1 - Terminals Definition NAME DESCRIPTION 1 Output Of Solid-State Relay #1 2 Output Of Solid-State Relay #2 3 Output Of Solid-State Relay #3 4 Output Of Solid-State Relay #4 H Hot Line Feed For Relays 1, 2, 3 & 4. N Neutral Bus Connections. Board 9 VAC SSR's OPTICAL ISOLATORS Table 2 - Absolute Maximum Electrical Ratings Electrical Characteristic Terminal Maximum LDM 0-10V Input connectors Relay Load Current 1 to 4 4 Amps. Input Current H 20 Amps. Input Voltage H 120 VAC Specifications: 4 x 500 Watts @ 120 VAC dimmer pack which is designed to be controlled either by a 4 x100 KOHM potentiometers ; one for each dimmer, or by a standard 0-10 V analog signal from a sinking or sourcing controller. Input specifications: 1 ma. current; Response range : 1 V = 0% ; 10 V = 100 % Dimmer power specifications: Operating Voltage: 120 VAC Input : 1 x 20 Amp Breaker Outputs: 4 x 500 Watts Figure 2 - control board 4 channel 0-10 V dimmer board Logic control firing board Output indicators 1 2 3 4 FRONT BACK TrimPot Switch level Switch or adjustment dimmer jumpers Switch 1 Dim 1 Switch 2 Dim 2 Switch 3 Dim 3 Switch 4 Dim 4 S D Each channel of the could be set to dim or switch. 4 Jumpers, 1 for each channel, are located on the back of the front cover. Place jumper on D side for normal 0-10V dimmer operation, place jumper on S side for switch operation. Switching control Voltage level could be set from 0 to 10 V with the TrimPot. 1 -UM

User's Manual - Page 2 Enclosure Installation Surface mount the dimmer pack in a well ventilated area where the ambient temperature does not exceed 104 F for full load operation. Allow 2" of side clearance for proper air circulation and servicing. Installation clearance shall meet local and/or NEC code requirements. Enclosures may be attached to the wall or other mounting surface by holes in the heat sink flanges. Refer to the drawings below (FIGURE 3) for the correct dimensions. Conduit shall be pulled to the top of the dimmer packs. Figure 3 - Dimensional Diagram 4.6 (117 mm) Top View Low Voltage Ports 1.1 (28mm) 2.4" (61 mm) 3.2 1.9" (82 mm) (48 mm) 0-10V Input connectors 1/2 and 3/4 Conduit Knockouts Bottom View 2.4 (61 mm) 3.1 (79 mm) 4 mounting Holes for #6 screws 10.6 x 2.4 HOT NEUTRAL T1 T4 8.5 (216 mm) Ground T2 L1 F1 L2 F2 F3 L3 F4 L4 T3 4 channel 0-10 V dimmer board Logic control firing board 11.2 (285 mm) J1 J2 10 VAC 5 0-10VDC 4 x 4 Amps Dimmer Pack LED's W3 W4 PD404 OPTO-ISOLATORS Output indicators Indicators 4.6" (117 mm) 0-10V Input connectors PD404 ( LDM) Load Driver Module PD404 Front Cover -UM

General Wiring Instructions Wiring Notes 0 DO NOT EXCEED 480 W (4 Amps. ) per each dimmer @ 120VAC. 0 All wiring From control to dimmers is low voltage (NEMA Class 2) 0 dimmer packs may be fed by one 20 A (maximum) branch circuit and may have up to Four separately dimmed loads. 0 CAUTION: DO NOT attempt to parallel outputs to increase capacity. 0 Installations must conform to local and/or NEC code requirements. 0 Each load must have its own Neutral wire for full load operation. 0 All line voltage wires must have copper conductors of adequate Gauge with 90 C wire insulation. 0 POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE TO ENSURE PROPER WIRING. #1 #4 User's Manual - Page 3 Figure 4 - Typical Wiring. Analog 0-10V inputs #2 #3 Optional: Could be also controlled with 4x 100 KOHM potentiometers. Figure 5 - Typical 120 VAC Wiring. From Electrical Distribution Panel 1x20 A - 120 VAC Breaker ON HOT INPUT NEUT. INPUT LOAD #1 Common LOAD #2 LOAD #3 LOAD #4 CAUTION: Fuses 1 to 4 are 5 Amps/250V ; quick blow to be replaced by certified electrician. Earth Ground H N N F1 F2 F3 F4 SSR1 SSR2 SSR3 SSR4 For Full Load Operation Use: #12 AWG copper conductor wire for Line & Neutral Feeds. #14 AWG copper conductors to each load. Follow N.E.C. requirements Max. Per Load: 4 Amperes (480 W at 120 VAC). Board H N 9 VAC SSR's OPTICAL ISOLATORS LDM 0-10V Input connectors -UM

LIMITED WARRANTY Digital Lighting Systems, warrants to the purchaser that its products have been carefully manufactured and inspected and are warranted to be free from defects of workmanship and materials when used as intended. Any abuse or misuse contrary to normal operation shall void this warranty. Digital Lighting Systems' obligation under this warranty shall be limited to replacement or repair of any units as shall within two years of date of invoice from Digital Lighting Systems, prove defective; and Digital Lighting Systems shall not be liable for any other damages, whether direct or consequential. The implied warranties of merchantability and fitness for a particular purpose are limited to the duration of the expressed warranty. Some states do not allow the exclusion of the limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, you may also have other legal rights which vary from state to state. Upon request, replacement unit(s) will be shipped as soon as available. Unless immediate shipment of replacement merchandise is requested, Digital Lighting Systems will not ship replacement merchandise until defective merchandise is received, inspected, and determined to be defective. No labor charges in connection with warranty problems will be reimbursed by Digital Lighting Systems without prior written approval from the factory. Digital Lighting Systems distributors and representatives have no authority to change this warranty without written permission. Digital Lighting Systems reserves the right to determine the best method of correcting warranty problems. Defective merchandise may be returned to Digital Lighting Systems, prepaid, after prior notification has been given and approval obtained for the return. To obtain prior approval for the return of the defective items, contact your local Digital Lighting Systems distributor, representative, or: Attn: Customer Service Department 12302 SW 128 Ct. Bay #105 Miami, FL 33186 (305) 969-8442 12302 SW 128 Ct. Miami, FL 33186 Tel 305-969-8442 Fax 305-969-8675 e-m info@digitallighting.com Printed in U.S.A. November 2011