PRESSURE SENSORS First in sensors

Similar documents
PRESSURE SENSORS CPS 1184 CPS 2184 SPS 1000 Z SPS 3003 LEADING IN SENSORS

LINEAR AND ROTARY SENSORS

SPT- I / U PRESSURE TRANSMITTER for general applications

JUMO MIDAS S05 Pressure transmitter Type

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

SUCO Product Overview

SUCO Product Overview

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

JUMO MIDAS Pressure transmitter

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

SSI Technologies MediaSensor

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

Electronic Pressure Switch EDS 3000

Pressure Sensor - EPT3100

Pressure Transmitter JUMO dtrans p30 Type

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

KD45 ±20N. Description

PRESSURE BENCH OPERATING INSTRUCTIONS

MS4515 SPECIFICATIONS FEATURES APPLICATIONS

Type A-10 General Purpose Pressure Transmitters

Industrial Pressure Transmitter

Pressure transmitter for industrial applications Type MBS 4510

0-5V, 1-5V, 1-6V 0-10V, 1-10V V

MS4525 SPECIFICATIONS

Pressure transducer DMU 01K Compact version

What is the secret to our success?

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

Pressure Sensors. for liquid and gaseous media

More Precision. mainsensor Magneto-inductive displacement sensor

Pressure transmitters for industrial applications Type MBS 4510

Pressure Precision. Description. Features. Measuring ranges. Applications. with front-flush diaphragm for gauge pressure and absolute pressure

FPT Applications. Features

FS5 Thermal Mass Flow Sensor For various gas flow applications

Type A-10 General Purpose Pressure Transmitter

Pressure transmitter for elevated media temperatures

ECT Applications. Features

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

Pressure sensor for liquid and gaseous media QBE620-P...

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Design Considerations for Pressure Sensing Integration

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Pressure Switches. Pressure switches, pneumatic. Pressure switches, electronic

Beck. The differential pressure transmitter for air with IP65

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

SP38D Piezoresistive single crystal silicon differential pressure sensor

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

EPI Applications. Features

via M3 DIN 931 hexagonal bolts in the groove or spring clips with inside diameter mm (not included)

Application Note Thermal Mass Flow Sensor FS7

pressure transducer Miniature pressure transducer model 81530

Marine Pressure ECTN Applications. Features

OEM Pressure Transmitters

Pressure transducers. with flush connections. Pressure transducers. with SIL assessment. HydroFox for level measurement

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

Seal material. Pressure range. Pressure connection -40 F +212 F 1 -4 F +257 F 3

FEATURES AND BENEFITS

Rotary Sensor potentiometric Heavy-duty. Series IPX-7900

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Piezoresistive Absolute Pressure Sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Pressure Transmitter JUMO dtrans p30 Type

KM26z 20N; 50N; 100N, 200N, 500N, 1kN, 2kN, 5kN

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

0 to 100 up to 0 to PSI (gage) Packard Electric Metri-Pack 150 Series, M12-4 Pole* 1/4-18 NPT ma, VDC, 0-5 VDC, 0-10 VDC

8710 EN. Potentiometric Displacement Sensors. Models 8710, 8711

Technical Datasheet P-30/P-31. Standard transmitter.

Pressure Transmitter Series TST Pressure Range bar, mbar, bar Output Signals ma, V

Pressure transmitter COMPACT ECOnomic

Industrial Pressure Transmitters

Products Solutions Services. Customized Pressure Sensors and Components Made by Endress+Hauser

EMERSON CLIMATE TECHNOLOGIES-EX

SITRANS P measuring instruments for pressure

G 1/4 A DIN 3852 (bar version) ±0.5 %FS max

Flush-mounted pressure and level transmitters - KERAMESS KS series 100/101 -

OEM relative pressure transmitter type 506

Electronic pressure switch with integrated analogue output

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Pressure Transmitters

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

HDS 5105 Amplified pressure sensor/switch

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Data Sheet P1A Pressure Sensor

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

Innovation in pressure sensing Simple-to-set compact electronic pressure switches. Pressure switches

Solid State Pressure Sensor. STX Series Model 13A FEATURES DESCRIPTION

SSI Technologies Application Note PS-AN4 MediaGauge (Model MG-9V) Digital Pressure Gauge Product Overview

EPN/EPNCR Applications. Features

Portable pressure calibrator, Wally Box III Model CPH7600

P1A Pressure Sensor. Description. Features. Applications MAIN FEATURES

SSI Technologies Application Note PS-AN4 MediaGauge (Model MG-9V) Digital Pressure Gauge Product Overview

HDS 5612 Unamplified pressure sensor

Mountable with O-ring seal Urea level ±0.5% Accuracy Urea pressure ±2.0 Total Error Band Air Brakes Corrosive fluid measurement for E&V applications

PMF4000 Series DESCRIPTION FEATURES APPLICATIONS MAXIMUM RATINGS MASS AIR FLOW SENSOR

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Pressure measurement PP20H Fully welded hygienic pressure sensor with flush membrane

Transcription:

PRESSURE SENSORS First IN SENSORS

2 First IN SENSORS TRUST THE X! Welcome to Metallux USA, Inc. Metallux USA, Inc. is the sole distributor of products for Metallux AG in Germany. A company that is internationally renowned for its sensor products. We are located in Western New York State in the city of Rochester on the southern shore of Lake Ontario. The City is the home of internationally-recognized academic institutions like the University of Rochester and Rochester Institute of Technology. Metallux USA, by virtue of our sole relationship status with Germany, allows us to possess a direct line of communication with the head office in Germany. This line provides customer and potential customers the ability to receive prompt and accurate answers to all of their technical inquire. OUR GUIDELINE: Fair partnership will ensure a successful and lasting business relationship. We pride ourselves in individual and direct consultation resulting in an innovative product range and reliability. Whether you are interested in industrial joysticks, sensors, linear or rotary measurement sensors, high voltage and power or brake resistor, Metallux USA Inc. is always your first choice for a successful, satisfactory and well executed solution for all your sensor applications. Bernd H. Oberascher President Metallux USA, Inc. Whether standard or customised solutions, we offer a broad range of sensor versions.

3 M e t allu x - u s a. com PRESSURE SENSORS CPS/SPS The CPS and SPS sensors are used to measure the of gaseous or liquid media. They are available in ceramic and stainless steel. A wide range of standard models ensure that you will find the perfect sensor for your application. 6-7 8-11 12-15 16-19 20-23 CPS 1010/2010 CPS 1010/2010 Drawings Connection diagrams CPS 1184 (Z) CPS 1184 / CPS 1184 Z Drawings Connection diagrams CPS 2184 (Z) CPS 2184 / CPS 2184 Z Drawings Connection diagrams SPS 1000 (Z) SPS 1000 / SPS 1000 Z Drawings Connection diagrams SPS 3003 (Z) SPS 3003 / SPS 3003 Z Drawings Connection diagrams

4 PRESSURE SENSORS PRESSURE SENSORS FROM METALLUX require Custom specific solutions? This is part of our customer service. The ceramic and stainless steel materials have been selected to ensureused assure a long and trouble free service life in most media. Choose from a comprehensive range of sensors. Our wide selection of sensors make it easy to find the right sensor for your application. You can rely on chemical resistant sensors. The materials have been selected for highly safe, reliable operation. Easy assembly so that your production process is seamless applications in: Hydraulics Pneumatics Pressure transmitters Pressure switches Pumps Force transmitters Filters High- cleaners Overview Version cps sps Page Pages 6 15 Pages 16 23 Materials Al2O3 x Stainless steel x Special features Stability <0.1% (150 1000h) x Standard temperature range 40...85 C x x Very high burst rating x Integrated connection x Output 0.5...4.5 V x x Applications Hydraulics x Pneumatics x Pressure transmitters x x Pressure switches x x Pumps x x Filters x High- cleaners x x

5 Metallux-usa.com Pressure measuring cells with thick-film technology on a ceramic or stainless steel base Perfect measuring cells for your applications Pressure transmitters / Pressure switches Ceramic sensors in thick-film technology reliably record s in transmitters and switches. These highly precise and affordable sensors monitor process parameters in production processes ensuring the quality of the manufactured products. Automotive applications Ceramic monolithic sensors perform various tasks in automotive applications. They are used to monitor filter, oil and fuel and monitor the pneumatic and hydraulic brake fluid circuits in commercial and private vehicles. High reliability, precision and highly resistant against aggressive media, make this technology suitable for an ever growing range of applications. Hydraulics/Refrigeration equipment An extremely high burst rating and high reliability make this SPS stainless steel sensor an attractive alternative. The monolith with screw connection eliminates the need for a seal between the sensor and the connection. This also eliminates the risk of mechanical weak points, such as welding joints. With this model, it is possible to achieve even higher resistance to aggressive media. Medical technology Some patients depend on dialysis equipment for their survival. There is zero room for error when it comes to the precision sensors that monitor the system. The manufacturers of dialysis systems put their trust in Metallux sensors. For self-cleaning dialysis equipment, the high chemical compatibility and front-flush diaphragm on the sensors are particularly attractive features.

6 PRESSURE SENSORS Ceramic standard sensor CPS 1010/2010 Whether monitoring filters in pneumatic applications, or in use in an automobile, the monolith ceramic sensors in the CPS 1010/2010 series are an affordable, yet robust choice. The ceramic material's excellent long-term stability and resistance to aggressive media are additional advantages of this sensor. TECHNICAL SPECIFICATIONS Resistance/Tolerance 10 kohm ± 20% Output signal Linearity, hysteresis, reproducibility Supply voltage Zero signal range Zero signal stability Span stability 1.5 3.5 mv/v ± 0.4%FS; pnom 60 bar ± 0.8%FS typ.; pnom >6 bar *** 5...30 V 0.2...+0.2 mv/v (opt. 0.1...+0.1 mv/v) ± 0.25% FS (1000h @ 125 C) ± 0.1% FS (2.5 million cycles 0...100%) ± 0.05% FS (1000h @ 125 C) ± 0.05% FS (2.5 million cycles 0...100%) Temperature error, zero point <±0.02% FS/K (0...85 C) * Material of parts that contact the media Dimensions Pressure type Al2O3 96% ** see dimensional drawings Relative Nominal Burst Vacuum 1.6...60 bar Factor 2.5 Vacuum-resistant 100 bar Factor 1.75 Vacuum-resistant 160 bar Factor 1.75 Vacuum-resistant 250 bar Factor 1.5 Vacuum-resistant 400 bar Factor 1.5 Vacuum-resistant 600 bar Factor 1.5 Vacuum-resistant Temperature error, span Electrical connectors Nominal/Operating/ Storage temperature range 0.012% FS/K (0...85 C) Tinned solder pads, pins, flat flexible cable; raster size 2.54 mm (CPS 1010) or 1.27 mm (CPS 2010) 40...125 C Mechanical and electrical characteristics are customisable. Specifications are subject to change without notice. * Sensor without cable ** Aluminium oxide offers high chemical resistance against a variety of measured media. We recommend that customers perform their own tests for new or untested applications. *** at max. setting acc. to DIN 16086 Sample order Type Pressure range in bar Electrical connection (acc. to drawing) CPS 1010 100 bar Solder pads Other dimensions and electrical specifications on request.

7 Metallux-usa.com Dimensional drawings / Connector schematic / Electrical connectors Pressure range 1.6 40 bar Pressure range 60 600 bar Pin assignment Ø 18.00±0.10 Ø 18.00±0.10 +Ub S Ub S+ 4.50 0.30 +0.50 0.2±0.1 X 45 4.50 0.30 +0.50 0.2 x 45 ±0.1 +Ub 0.2 0.2 x 45 6.35±0.05 0.2 x 45 0.2 6.35±0.05 12.50 Ø 9.68±0.10 12.50 Ø 5.255±0.10 S+ 10K 10K 10K 10K S Ub R0.75 R0.75 22.50 22.50 Tinned connectors Sn95.6 Ag3.8 Cu0.6 Flex: A04-N065-N(Nomex) Cover: PUR 36788-1TM Flat flexible cable: 4 X AWG26 2.54mm Cover: PUR 36788-1TM Pins: 0.5 X 0.27 tinned Masking lacquer Masking lacquer Tin thickness 0.2±0.1 Ø 0.5 0.3 3.3±0.2 2±0.5 2±0.5 13.00 2±0.5 max. 2.0 Variable length max 12 mm, min. 4 mm 65.0±1.0 66.0±3 5.30±0.20 2.54

8 PRESSURE SENSORS Ceramic standard sensor CPS 1184 Metallux monolithic sensors are manufactured in large series and are in use in a range of applications in machinery production, the automotive industry, and ventilation and climate control equipment. The easy installation and calibration of the sensors simplifies the customer's production processes. The CPS 1184 features a compact design, high media compatibility and excellent long-term stability. TECHNICAL SPECIFICATIONS Resistance/Tolerance 10 kohm ± 20% Output signal Linearity, hysteresis, reproducibility Supply voltage Zero signal range Zero signal stability Span stability See table "Span" ± 0.4% FS typ.; pnom 60 bar ± 0.8% FS typ.; pnom >6 bar max < ± 1.5% FS *** 5...30 V 0.2...0 mv/v * (opt. 0.1...0 mv/v) * ± 0.25% FS (1000h @ 125 C) ± 0.1% FS (2.5 million cycles 0...100%) Temperature error, zero point < ± 0.02% FS/K * Temperature error, span Electrical connectors Nominal/Operating/ Storage temperature range Material of parts that contact the media Dimensions Pressure type ± 0.05% FS (1000h @ 125 C) ± 0.05% FS (2.5 million cycles 0...100%) 0.012% FS (0...85 C) Tinned solder pads, pins, flat flexible cable 40...125 C * Al2O3 96% ** see dimensional drawings Relative Nominal Span Burst Vacuum 1.6 bar 1.5...2.8 mv/v 4 bar Vacuum-resistant 2.5 bar 2.5...4.4 mv/v 7 bar Vacuum-resistant 4 bar 1.5...2.8 mv/v 15 bar Vacuum-resistant 6 bar 2.4...4.2 mv/v 15 bar Vacuum-resistant 10 bar 2.7...4.0 mv/v 35 bar Vacuum-resistant 16 bar 2.2...3.5 mv/v 50 bar Vacuum-resistant 25 bar 3.7...5.3 mv/v 70 bar Vacuum-resistant 40 bar 2.0...3.3 mv/v 150 bar Vacuum-resistant 60 bar 3.2...4.8 mv/v 150 bar Vacuum-resistant 100 bar 2.1...2.7 mv/v 250 bar Vacuum-resistant 160 bar 1.4...2.7 mv/v 320 bar Vacuum-resistant 250 bar 2.2...4.2 mv/v 450 bar Vacuum-resistant 400 bar 1.4...2.9 mv/v 700 bar Vacuum-resistant Mechanical and electrical characteristics are customisable. Specifications are subject to change without notice. * Sensor without cable ** Aluminium oxide offers high chemical resistance against a variety of measured media. We recommend that customers perform their own tests for new or untested applications. *** at max. setting acc. to DIN 16086 Sample order Type Pressure range in bar Electrical connection (acc. to drawing) CPS 1184 100 bar Solder pads Other dimensions and electrical specifications on request.

9 Metallux-usa.com Dimensional drawings / Connector schematic / Electrical connectors Pressure range 1.6 400 bar Pin assignment Ø 18.00±0.10 0.2+0.3 X 45 30.00 metallux-usa.com Identification No. +Ub S Ub S+ +Ub Ø 14.5±0.15 0.2+0.3 X 45 6.35±0.05 Ø 9.68±0.10 4.35 4.77 1.53 1.60 2.54 0.94 Pressured area: Width of assembly ring min. 0.5 mm Designation Pressured area S 10K 10K 10K 10K S+ Ub R0.75 Tinned connectors Sn95.6 Ag3.8 Cu0.6 Flex: B04-N025-A(Nomex) Cover: PUR 36788-1TM Flat flexible cable: 4 X AWG26 2.54mm Cover: PUR 36788-1TM Pins: 0.5 X 0.27 tinned Masking lacquer Masking lacquer Tin thickness 0.2±0.1 Ø 0.5 0.3 3.3±0.2 2±0.5 2±0.5 2±0.5 13.00 max 2.0 Standard pin length 12 mm 65.0±1.0 66.0±3 5.30±0.20 2.54

10 PRESSURE SENSORS Ceramic standard sensor CPS 1184 Z with output amplifier The ceramic sensors in the CPS 1184 Z series are integrated with an amplifier and are supplied calibrated to an output signal of 0.5 V to 4.5 V. The excellent long-term stability and high resistance against a wide range of media are additional features of this sensor series. Technical specifications Supply voltage (stabilised) 5 V (± 0.5 V) Nominal Span Burst Vacuum 1.6 bar 0.5...4.5 V 4 bar Vacuum-resistant Output signal (ratiometric) Calibration error 0.5...4.5 V ± 0.5% FS 2.5 bar 0.5...4.5 V 7 bar Vacuum-resistant 4 bar 0.5...4.5 V 15 bar Vacuum-resistant Measurement error due to mech. stress Total error (sum of non-linearity, hysteresis, non-reproducibility) Temperature error, zero point < 0.5% FS (typ.) pnom > 60 bar; typ. < ± 0.4%FS; max. < ± 1.5% FS *** < ± 0.02% FS/K Temperature error, span 0.012% FS/K Response time Change in zero signal 1000h@125 C Power consumption < 2ms </= ± 0.3% FS < 2.5mA 6 bar 0.5...4.5 V 15 bar Vacuum-resistant 10 bar 0.5...4.5 V 35 bar Vacuum-resistant 16 bar 0.5...4.5 V 50 bar Vacuum-resistant 25 bar 0.5...4.5 V 70 bar Vacuum-resistant 40/50 bar 0.5...4.5 V 150 bar Vacuum-resistant 100 bar 0.5...4.5 V 250 bar Vacuum-resistant 160 bar 0.5...4.5 V 320 bar Vacuum-resistant 250 bar 0.5...4.5 V 450 bar Vacuum-resistant Output load resistance 1...5 kohm 400 bar 0.5...4.5 V 700 bar Vacuum-resistant Load capacity < 0.05 µf Nominal/Operating/ Storage temperature range Electrical connectors Pressure type 40...125 C Solder pads Relative Mechanical and electrical characteristics are customisable. Specifications are subject to change without notice. * Sensor without cable ** Aluminium oxide offers high chemical resistance against a variety of measured media. We recommend that customers perform their own tests for new or untested applications. *** at max. setting acc. to DIN 16086 Sample order Type Pressure range in bar Electrical connection (acc. to drawing) CPS 1184 Z 100 bar Solder pads Other dimensions and electrical specifications on request.

11 Metallux-usa.com Dimensional drawings / Connector schematic / Electrical connectors Pressure range 1.6 400 bar Ø 18.00±0.10 0.2+0.3 X 45 30.00 metallux-usa.com Identification No. Ø 14.5±0.15 0.2+0.3 X 45 6.35±0.05 4.35 4.77 1.53 Ø 9.68±0.10 R0.75 Electrical connection OUT GND Uin 4.60±0.25 1.0+0.7 0.4 A A Ø 14.90±0.15 Ø 18.00 Masking lacquer Distance from fastening element min. 0.5 mm 1.60 2.54 0.94 Designation Pressured area

12 PRESSURE SENSORS Ceramic standard sensor CPS 2184 The CPS 2184 sensors with front-flush diaphragm seal are suitable for measurement of relative as well as absolute s. The flushfront diaphragm makes for easy cleaning, an important requirement for sensors used in the medical and food industry. The sensors are also available with diaphragms consisting of 99.6% aluminium oxide. The sensors are also available with diaphragms with 99.6% aluminium oxide, for applications with extremely aggressive media. Technical specifications Resistance/Tolerance 10 kohm ± 20% Output signal Linearity, hysteresis, reproducibility Supply voltage See table Span ± 0.4% FS *** 5...30 V Zero point offset 0.2... 0 mv/v * Stability of offset < ± 0.25% FS after 1000 h @ 125 C Temperature error, zero point Temperature error, span Nominal/Operating/ Storage temperature range ± 0.02% FS/K (R) (0...85 C) ± 0.03% FS/K (A, SG) (0...85 C) 0.012% FS/K (0...85 C) 40...125 C Electrical connectors Tinned solder pads, pin 12mm Pressure type Relative, absolute, sealed gauge 0.5 bar: only relative 1 bar... 50 bar: relative (R), absolute (A) and sealed gauge (SG) possible 100 bar... 600 bar: only sealed gauge Nominal Height X Burst Span Permissible under 0.5 bar 6.13 mm 2 bar 1.5...2.4 mv/v 0.15 bar 1 bar 6.20 mm 4 bar 2.2...3.5 mv/v 0.20 bar 2 bar 6.25 mm 5 bar 2.0...4.0 mv/v 0.40 bar 5 bar 6.30 mm 12 bar 2.4...4.5 mv/v 0.80 bar 10 bar 6.35 mm 25 bar 3.6...6.0 mv/v Vacuum-resistant 20 bar 6.55 mm 50 bar 2.4...4.0 mv/v Vacuum-resistant 50 bar 6.70 mm 120 bar 3.8...6.0 mv/v Vacuum-resistant 100 bar 6.70 mm 250 bar 3.0...4.8 mv/v Vacuum-resistant 200 bar 7.05 mm 500 bar 2.5...4.0 mv/v Vacuum-resistant 400 bar 7.35 mm 650 bar 3.0...4.6 mv/v Vacuum-resistant 600 bar 7.55 mm 880 bar 3.0...4.6 mv/v Vacuum-resistant Mechanical and electrical characteristics are customisable. Specifications are subject to change without notice. * Sensor without cable ** Aluminium oxide offers high chemical resistance against a variety of measured media. We recommend that customers perform their own tests for new or untested applications. *** at max. setting acc. to DIN 16086 Sample order Type Pressure range in bar Pressure type Electrical connection (acc. to drawing) CPS 2184 100 bar A/R/SG Solder pads Other materials, dimensions and electrical specifications on request.

13 Metallux-usa.com Dimensional drawings / Connector schematic / Electrical connectors Ø 18±0.1 R 0.75 B Solder ball (only for absolute version) 30.00 Vref S+ Lo+ S Lo metallux-usa.com Identification No. Lo Lo+ 1.35±0.35 Ø 14±0.15 Printed area, fitting clamp distance min. 0.5 mm Pressure range area Total height X see table 18.00±0.10 0.25 B Sensitive Area Ø 9.40 TaBle for value x 0 0.5 bar 6.13 ±0.15 0 1 bar 6.20 ±0.15 0 2 bar 6.25 ±0.15 0 5 bar 6.30 ±0.15 0 10 bar 6.35 ±0.15 0 20 bar 6.55 ±0.15 S 10K 10K 10K 10K Vref Projection-methode A S+ 0 50 bar 6.70 ±0.15 Tinned connectors: Sn95, 6 Ag3, 8Cu0.6 Flat flexible cable: 4 x AWG26 2.54 mm, cover: PUR 36788-1TM Pins: 0.5 x 0.27 tinned Projection-methode B Coating Tin height 0.2±0.1 2±0.5 2±0.5 max. 2.0 Length variable max. 12 mm, min. 6 mm 66.0±3 22.9±0.20 2.54

14 PRESSURE SENSORS Ceramic standard sensor CPS 2184 Z Customers in the food, pharmaceutical and chemical industry rely on the flush mounted sensors of the series CPS 2184Z with integrated amplifier. The sensors are calibrated to an output signal of 0.5V to 4.5V. Characteristic for this series is an excellent long term stability and its suitability to operate in a harsh environment. Technical specifications Supply voltage (stabilised) 5 V (± 0.5 V) Output signal (ratiometric) Calibration error Measurement error due to mech. stress 0.5...4.5 V ± 0.5% FS < 0.5% FS (typ.) Total error ± 0.4% FS *** Temperature error, zero point Temperature error, span Response time Change in zero signal 1000h@125 C Power consumption Output load resistance < ± 0.02% FS/K (<± 0.03%FS/K for SG and A) * 0.012% FS/K < 2 ms </= ± 0.3% FS < 2.5 ma 1...5 kohm Load capacity < 0.05 µf Nominal/Operating/ Storage temperature range Electrical connectors Pressure type 40...125 C Solder pads Relative, absolute, sealed gauge Nominal Height X Burst Span Permissible under 0.5 bar 6.13 mm 2 bar 0.5 4.5 V 0.15 bar 1 bar 6.20 mm 4 bar 0.5 4.5 V 0.20 bar 2 bar 6.25 mm 5 bar 0.5 4.5 V 0.40 bar 5 bar 6.30 mm 12 bar 0.5 4.5 V 0.80 bar 10 bar 6.35 mm 25 bar 0.5 4.5 V Vacuum-resistant 20 bar 6.55 mm 50 bar 0.5 4.5 V Vacuum-resistant 50 bar 6.70 mm 120 bar 0.5 4.5 V Vacuum-resistant 100 bar 6.70 mm 250 bar 0.5 4.5 V Vacuum-resistant 200 bar 7.05 mm 500 bar 0.5 4.5 V Vacuum-resistant 400 bar 7.35 mm 650 bar 0.5 4.5 V Vacuum-resistant 600 bar 7.55 mm 880 bar 0.5 4.5 V Vacuum-resistant 0.5 bar: only relative 1 bar... 50 bar: relative (R), absolute (A) and sealed gauge (SG) possible 100 bar... 600 bar: only sealed gauge Mechanical and electrical characteristics are customisable. Specifications are subject to change without notice. * Sensor without cable ** Aluminium oxide offers high chemical resistance against a variety of measured media. We recommend that customers perform their own tests for new or untested applications. *** at max. setting acc. to DIN 16086 Sample order Type Pressure range in bar Pressure type Electrical connection (acc. to drawing) CPS 2184 Z 100 bar SG Solder pads Other materials, dimensions and electrical specifications on request.

15 Metallux-usa.com Dimensional drawings / Connector schematic / Electrical connectors Ø 18±0.1 R 0.75 B Solder ball (only for absolute version) 30.00 Vref S+ Lo+ S Lo metallux-usa.com Ident. No. Lo Lo+ Ø 14±0.15 Printed area 1.35±0.35 Pressure range area Total height X see table 18.00±0.10 0.25 B Sensitive Area Ø 9.40 TaBle for value x 0 0.5 bar 6.13 ±0.15 0 1 bar 6.20 ±0.15 0 2 bar 6.25 ±0.15 0 5 bar 6.30 ±0.15 0 10 bar 6.35 ±0.15 0 20 bar 6.55 ±0.15 S 10K 10K 10K 10K Vref Projection-methode A S+ 0 50 bar 6.70 ±0.15 Signal conditioning board Electrical connection Uin GND OUT 0.4 A A Ø 14.90±0.15 Ø 18.00 4.60±0.25 1.0+0.7

16 PRESSURE SENSORS Stainless steel standard sensor SPS 1000 The stainless steel sensors of the SPS 1000 series excel particularly through good overload and burst characteristics. Even in cases of peaks, the monolithic sensors offer outstanding safety features. Operating in an aggressive media does not influence their superb performance. TECHNICAL SPECIFICATIONS Resistance/Tolerance 10 kohm ± 20% Output span signal Maximum current Imax. Linearity, hysteresis, reproducibility (depends on range)** Supply voltage Zero point offset Stability of zero point (1000h @ 125 C) Insulation resistance Temperature error, zero point (TK 0 0...85 C) Temperature error, span (TK S 0 85 C) Nominal/Operating/ Storage temperature range Electrical connectors Pressure type See table Span 4 ma ± 0.5...1.5% FS 5...30 V 0.5...0 mv/v 0.4% FS 100 MOhm at 500 VDC, 25 C, 75% rel. humidity ± 0.03% FS/K ± 0.03% FS/K typ. ( ± 0.05% FS/K max.) 40...125 C Tinned solder pads, flat flexible cable Relative Nominal Span Overload Burst Mechanical and electrical characteristics are customisable. Specifications are subject to change without notice. Vacuum 10 bar 1.5...3.5 mv/v 20 bar > 50 bar Vacuum-resistant 25 bar 1.5...3.5 mv/v 50 bar > 125 bar Vacuum-resistant 40 bar 1.5...3.5 mv/v 80 bar > 200 bar Vacuum-resistant 60 bar 1.5...3.5 mv/v 120 bar > 300 bar Vacuum-resistant 100 bar 1.5...3.5 mv/v 200 bar > 500 bar Vacuum-resistant 160 bar 1.5...3.5 mv/v 320 bar > 650 bar Vacuum-resistant 250 bar 1.5...3.5 mv/v 500 bar > 750 bar Vacuum-resistant 400 bar 1.5...3.5 mv/v 800 bar > 1200 bar Vacuum-resistant 600 bar 1.5...3.5 mv/v 1200 bar > 1800 bar Vacuum-resistant 1000 bar 1.5...3.5 mv/v 2000 bar > 2500 bar Vacuum-resistant Sample order Type Pressure range in bar Electrical connection (acc. to drawing) SPS 1000 100 bar Solder pads Other dimensions and electrical specifications on request.

17 Metallux-usa.com Dimensional drawings / Connector schematic / Electrical connectors Pressure range 10 1000 bar Pin assignment Ø 18.00±0.10 30.00 +Ub S Ub S+ 0.2+0.15 X 45 metallux-usa.com Identification No. +Ub Ø 15.5±0.25 0.2+0.3 X 45 0.5+0.2 X 45 6.35±0.05 Ø 9.68±0.10 4.35 4.77 1.53 1.60 2.54 0.94 Masking lacquer Distance from fastening element min. 0.5 mm Designation Pressured area S 10K 10K 10K 10K S+ Ub R0.75 Tinned connectors: Sn95.6 Ag3.8 Cu0.6 Flex: A04-N065-N(Nomex) Cover: PUR 36788-1TM Flat flexible cable: 4 X AWG26 2.54mm Cover: PUR 36788-1TM Pins: 0.5 X 0.27 tinned Masking lacquer Masking lacquer Tin thickness 0.2±0.1 Ø 0.5 0.3 3.3±0.2 2±0.5 2±0.5 2±0.5 13.00 max 2.0 Variable length max 12 mm, min. 4 mm 65.0±1.0 66.0±3 5.30±0.20 2.54

18 PRESSURE SENSORS Stainless steel standard sensor SPS 1000 Z Monolithic sensors in stainless steel provide high overload capacity and provide an output signal of 0.5V to 4.5V. The SPS 1000 Z amplifier makes it easy to further process the sensor signal. As with the SPS 1000, an important feature of this sensor is its above average chemical resistance and an excellent long term stability. TECHNICAL SPECIFICATIONS Supply voltage Us Output span signal Calibration error Measuring error due to mechanical tension Linearity, hysteresis, reproducibility (depends on range)** Stability of zero point (1000h @ 125 C) Insulation resistance Temperature error, zero point (TK 0 0...85 C) Temperature error, span (TK S 0 85 C) Power consumption Response time (10...90% of the measuring range) Switching delay Output load resistance 5 V ± 0.5 V 0.5...4.5 V ± 0.5% FS < 0.5% FS (typ.) ± 0.4...1.5% FS ± 0.3% FS 100 MOhm at 500 VDC, 25 C, 75% rel. humidity ± 0.04% FS/K ± 0.03% FS/K typ. ( ± 0.05% FS/K max.) 2.5 ma < 2 msec. < 250 msec. 1...5 kohm Load capacity < 0.05 µf Nominal/Operating/ Storage temperature range 40...125 C Electrical connectors Pressure type Nominal Output signal Overload Solder pads Relative Burst Vacuum 10 bar 0.5...4.5 V 20 bar > 50 bar Vacuum-resistant 25 bar 0.5...4.5 V 50 bar > 125 bar Vacuum-resistant 40 bar 0.5...4.5 V 80 bar > 200 bar Vacuum-resistant 60 bar 0.5...4.5 V 120 bar > 300 bar Vacuum-resistant 100 bar 0.5...4.5 V 200 bar > 500 bar Vacuum-resistant 160 bar 0.5...4.5 V 320 bar > 650 bar Vacuum-resistant 250 bar 0.5...4.5 V 500 bar > 750 bar Vacuum-resistant 400 bar 0.5...4.5 V 800 bar > 1200 bar Vacuum-resistant 600 bar 0.5...4.5 V 1200 bar > 1800 bar Vacuum-resistant 1000 bar 0.5...4.5 V 2000 bar > 2500 bar Vacuum-resistant Mechanical and electrical characteristics are customisable. Specifications are subject to change without notice. Sample order Type Pressure range in bar Electrical connection (acc. to drawing) SPS 1000 Z 100 bar Solder pads Other dimensions and electrical specifications on request.

19 Metallux-usa.com Dimensional drawings / Connector schematic / Electrical connectors Pressure range 5 1000 bar Ø 18.00±0.10 0.2 x 45 +0.3 30.00 metallux-usa.com Ident No. Ø 14.5±0.15 0.2 x 45 +0.3 0.5 x 45 +0.2 6.35±0.05 4.35 4.77 1.53 Printed area: fitting clamp distance min. 0.5 mm Pressure range labeling Ø 9.68±0.10 1.60 2.54 0.94 R0.75 Signal conditioning board Electrical connection OUT GND Uin 4.60±0.25 1.0+0.7 0.4 A A Ø 14.90±0.15 Ø 18.00

20 PRESSURE SENSORS Stainless steel standard sensor SPS 3003 The SPS 3003 series of stainless steel sensors with integrated connector provides reliable operation in applications with aggressive media. There is no need for a seal between the sensor measuring cell and connection. The high overload capacity and very high burst rating are additional advantages of this sensor. In the case of an error or undefined peaks in, the medium remains in the system TECHNICAL SPECIFICATIONS Resistance/Tolerance 10 kohm ± 20% Output span signal Maximum current Imax. Linearity, hysteresis, reproducibility (depends on range) Supply voltage Zero point offset Stability of zero point (1000h @ 125 C) Insulation resistance Temperature error, zero point (TK 0 0...85 C) Temperature error, span (TK S 0 85 C) Nominal/Operating/ Storage temperature range Electrical connectors Pressure type 1.5...3.5 mv/v 4 ma ± 0.4...1.5% FS *** 5...30 V 0.5...0 mv/v 0.4% FS 100 MOhm at 500 VDC, 25 C, 75% rel. humidity ± 0.03% FS/K ± 0.03% FS/K typ. ( ± 0.05% FS/K max.) 40...125 C Tinned solder pads Relative Nominal Span Overload Burst Vacuum 10 bar 1.5...3.5 mv/v 20 bar > 50 bar Vacuum-resistant 25 bar 1.5...3.5 mv/v 50 bar > 125 bar Vacuum-resistant 40 bar 1.5...3.5 mv/v 80 bar > 200 bar Vacuum-resistant 60 bar 1.5...3.5 mv/v 120 bar > 300 bar Vacuum-resistant 100 bar 1.5...3.5 mv/v 200 bar > 500 bar Vacuum-resistant 160 bar 1.5...3.5 mv/v 320 bar > 650 bar Vacuum-resistant 250 bar 1.5...3.5 mv/v 500 bar > 750 bar Vacuum-resistant 400 bar 1.5...3.5 mv/v 800 bar > 1200 bar Vacuum-resistant 600 bar 1.5...3.5 mv/v 1200 bar > 1800 bar Vacuum-resistant 1000 bar 1.5...3.5 mv/v 2000 bar > 2500 bar Vacuum-resistant Mechanical and electrical characteristics are customisable. Specifications are subject to change without notice. *** at max. setting acc. to DIN 16086 Sample order Type Pressure range in bar Electrical connection (acc. to drawing) SPS 3003 100 bar Solder pads Other dimensions and electrical specifications on request.

Ø 18.00±0.10 21 Metallux-usa.com Dimensional drawings / Connector schematic / Electrical connectors HEX 22 Ø 17.00 +0.00 0.10 1.85±0.1 3.25±0.1 +Ub S Ub S+ +Ub 12.00±0.10 24.00 0.64 1.90 2.54 6.00 5.61 3.84 metallux-usa.com Identification No. 2.65±0.30 G 1/4" A R8.00±0.25 Pressured area: Fastening not possible S 10K 10K 10K 10K S+ Ub Cut-out for O-ring Ø 6 X 1.5 Solder pads 3.84 2.16 Pins: 0.5x0.27 tinned max. 2.0 mm 2 X soldering possible with lead-free Sn96Ag 3.5 Cu0.5 max. soldering temperature: 350 C Preheating: 140 C Soldering time: < 3.5 sec. Ø 17.00 1.77 2.16 2.54 2.54 4.75±0.35 12.0±0.5

22 PRESSURE SENSORS Stainless steel standard sensor SPS 3003 Z The SPS 3003 Z series unites a stainless steel sensor with an integrated connection and an amplifier circuit. The 0.5V...4.5V output is proportional to the applied. No seal is required between the sensor and connection, which makes the sensor particularly resistant to aggressive media. Its high burst rating also makes it ideal for hydraulic applications. TECHNICAL SPECIFICATIONS Supply voltage Us Output span signal Calibration error Measuring error due to mechanical tension Linearity, hysteresis, reproducibility (depends on range) ** Stability of zero point (1000h @ 125 C) Insulation resistance Temperature error, zero point (TK 0 0...85 C) Temperature error, span (TK S 0 85 C) Power consumption Response time (10...90% of the measuring range) Switching delay 5 V ± 0.5 V 0.5...4.5 V ± 0.5% FS < 0.5% FS (typ.) ± 0.4...1.5% FS 0.4% FS 100 MOhm at 500 VDC, 25 C, 75% rel. humidity ± 0.04% FS/K ± 0.03% FS/K typ. ( ± 0.05% FS/K max.) 2.5 ma < 2 msec. < 250 msec. Nominal/Operating/ Storage temperature range Electrical connectors Pressure type Nominal Overload 40...125 C Tinned solder pads Relative Burst Vacuum 10 bar > 20 bar > 50 bar Vacuum-resistant 25 bar > 50 bar > 125 bar Vacuum-resistant 40 bar > 80 bar > 200 bar Vacuum-resistant 60 bar > 120 bar > 300 bar Vacuum-resistant 100 bar > 200 bar > 500 bar Vacuum-resistant 160 bar > 320 bar > 650 bar Vacuum-resistant 250 bar > 500 bar > 750 bar Vacuum-resistant 400 bar > 800 bar > 1200 bar Vacuum-resistant 600 bar > 1200 bar > 1800 bar Vacuum-resistant 1000 bar > 2000 bar > 2500 bar Vacuum-resistant Output load resistance 1...5 kohm Load capacity < 0.05 µf Mechanical and electrical characteristics are customisable. Specifications are subject to change without notice. Sample order Type Pressure range in bar Electrical connection (acc. to drawing) SPS 3003 Z 100 bar Solder pads Other dimensions and electrical specifications on request.

23 Metallux-usa.com Dimensional drawings / Connector schematic / Electrical connectors SPS 3003 Base element SPS 3003 ZMD Circuit board HEX 22 0.4 A A Ø 18.00±0.10 Ø 17.00 +0.00 0.10 24.00 12.00±0.10 4.60±0.25 1±0.7 1.85±0.1 3.25±0.1 Ø 15.0±0.2 Ø 17.00 Label: Pressure range CW/YY 2.65±0.30 G 1/4" A Pin assignment on amplifier board Out GND V Uin Cut-out for O-ring Ø 6 X 1.5

www.metallux-usa.com Metallux USA, Inc. Building C, Suite 4 3495 Winton Place Rochester, NY 14623 U.S. of America PHONE +1 (585)360-0054 FAX +1 (866)429-0360 E-mail: info@metallux-usa.com