WGA Long throw nozzle grille

Similar documents
Nozzle Jet Diffuser Model DSA

Ceiling diffuser 4DE

Compact Grille Model KG

Ventilation grille Model AL

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

Ventilation grille Model IB-R

Swirl Diffuser Model DQF

ceiling swirl diffuser DQJ

Ventilation Grille PA

Ceiling diffuser 4DF

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser DSC

Ceiling impulse diffuser Model PIL

Lint separator FLARE

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser Model DSX

Ceiling Swirl Diffuser DQJ

ceiling swirl diffuser Model DQJA / DQJR

Round duct grille Model KG-RR

DSC-PLASTER Slot diffuser for plasterboard ceilings

Long Throw Nozzle WDA

Round duct diffuser DBB-RR

LAQ Return air diffuser

Air diffuser system Model AUDIX -AW

Particle Filter Box Model FKF

Mechanical mixing box MBM

Particle Filter Box FKU

Technical documentation

Ceiling induction diffuser DISA-300

Ceiling induction diffuser DISA-601

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Slot diffusers, Round duct diffusers. IMP Klima

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Ceiling swirl diffusers

Round Duct System Model RR-Complete

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Ceiling swirl diffusers with perforated face plate

Ventilation grilles for installation into walls, sills or rectangular

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers

Round Duct System Model RR-Complete

WALL VENTILATION GRILLES CBP

Volumetric Flow Limiter VOLKOM

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Ceiling swirl diffusers

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Ventilation grilles for installation into walls, sills or rectangular

Round Duct System Accessories RR - accessories

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

Grilles Linear Grilles

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Fan coil unit NBS 100/150

Slot diffusers for ceiling installation

Weather protection grille ALAS

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

Catalog Swirl diffuser DAL 358

DRUM SLOT DIFFUSER TYPE: RT350

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

ISF-AD. Inclined Floor Swirl Diffuser PRODUCT BROCHURE. Optional Features: Constant throw height adjustable airflow rate Electrical VAV operation

1/8/EN/6. Floor Diffusers. Type FB. in aluminium and plastic

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Ceiling air diffuser INDULCLIP INDUDRALL KOMBICLIP

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS

Catalog Swirl diffuser DAL 359

Air Displacement Vent Units

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Active Chilled Beams

Grilles Linear Grilles

GDD - Supply Grille. Halton GDD. Supply Grille

Duct Nozzle Diffuser. L e

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY

CornerAir. CornerAir. Active chilled beam

INDEX. Chapter1 1. A. Jet diffusers 1. Jet diffuser...: AJD-P

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY

Active Chilled Beams

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

ACTIVENT System. Specifications. Product code example ACTA

NSDZ. Swirl diffusers with adjustable air control blades

Ventiduct nozzle ducts

series Linear grilles

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

IMP Klima. Swirl diffusers. Variable swirl diffusers

volumetric flow controller Model VRA-Q Smart

Floor Swirls Models BZD and SZD

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CNVA TECHNICAL DOCUMENTATION. Active floor convector. Contents

Wall and Ceiling Grille

DATASHEET PRODUCT CODE EXAMPLE:

Fire/smoke damper EKO-JBG2

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

Transcription:

Technical documentation WGA Long throw nozzle grille Contents Function and use... 2 Models... 2 Processing... 3 Accessories... 3 Models and dimensions... 4 Quick selection... 12 Installation situation... 12 Band design... 13 Dimensions of accessories... 14 Fastening methods... 16 Technical data... 17 Legend... 25 Order code... 26 Plenum box order code... 27 Specification texts... 28 SCHAKO Ferdinand Schad KG Phone +49 (0) 7463-980-0 Steigstraße 25-27 Fax +49 (0) 7463-980-200 D-78600 Kolbingen www.schako.de info@schako.de

Function and use I Models FUNCTION AND USE Since multi-purpose halls have many different uses, great demands are placed on their air-conditioning and ventilation requirements. Since both sporting and cultural events are held in these halls, requirements with regard to supply of air volumes and temperature differences between supply and room temperature also change. The long throw nozzle grille type WGA has been specially developed to cope with these different requirements. The advanced and well designed construction of the grille allows high throw speeds at low noise levels. The high throw speeds result in deep penetration of the room to be ventilated. This ensures that fresh air is circulated throughout the whole room and not just near the supply air grille itself. A further advantage of the long throw nozzle grille is that the entire air jet is divided into a large number of individual jets, thus resulting in a high level of induction. The temperatures and velocities of the individual jets are very quickly reduced. This means that on the one hand the supply air does not drop into the occupied area in cooling mode and, on the other hand the air does not rise too fast towards the ceiling in heating mode. The long throw nozzle grille type WGA-Q-V0-... with individually manually adjustable nozzles allows a diverging air jet (pivoting range 45 ). To achieve an even greater throw for cooling applications and effective, energy saving room heating for heating applications, the long throw nozzle grille type WGA- Q-V0-... has been designed with individually or jointly adjustable nozzles. In the WGA-Q-VG-..., WGA-Q-VE-... and WGA-Q- VT-..., the nozzles are fitted to a pivoting faceplate which can be adjusted manually, electrically or by means of a thermocouple (pivoting range 34 ). In the model with thermocouple, at a supply air temperature of 20 C or lower the nozzles of the WGA- -VT- are in the cooling position with throw direction diagonally upwards (max. angle 17 ). At a supply air temperature of 35 C or higher, the nozzles of the WGA- -VT- are in the heating position with throw direction diagonally upwards (max. angle - 17 ). In the temperature range between 20 C and 35 C, the nozzle rows are adjusted linearly. The long throw nozzle grille is available in models WGA-R-F0-..., WGA-R-V0-..., WGA-R-VG-..., WGA-R-VE-... and WGA-R-VT-... for direct installation in round ducts. At an extra charge, bars can be fitted to the faceplate as ball-impact guards. An integrated hit-and-miss damper is available for simple air volume regulation. MODELS WGA-Q-F0- WGA-Q-V0- WGA-Q-VG- WGA-Q-VE- WGA-Q-VT- WGA-R-F0- WGA-R-V0- WGA-R-VG- WGA-R-VE- WGA-R-VT- For installation in walls / ducts, fixed nozzles. For installation in walls / ducts, individually adjustable nozzles. For installation in walls / ducts, nozzles jointly manually adjustable. For installation in walls / ducts, nozzles jointly electrically adjustable. For installation in walls / ducts, nozzles jointly adjustable via thermocouple without electrical energy. For installation in round ducts, fixed nozzles. For installation in round ducts, individually adjustable nozzles. For installation in round ducts, nozzles jointly manually adjustable. For installation in round ducts, nozzles jointly electrically adjustable. For installation in round ducts, nozzles jointly adjustable via thermocouple without electrical energy. MOUNTING Screw mounting (-SM, standard) -- Screws must be provided on site Concealed mounting (-VM) (-VM, only possible for WGA-Q- F0... and WGA-Q-V0-...) -- with VM pole brace Number of nozzles WGA-Q- L 325 425 525 625 825 1025 1225 125 3 4 5 6 8 10 12 H 225 6 8 10 12 16 20 24 325 9 12 15 18 24 30 36 Number of nozzles WGA-R- L 325 425 525 625 825 1025 1225 H 125 3 4 5 6 8 10 12 225 6 8 10 12 16 20 24 At an extra charge, a plenum box can be mounted (only available without hit-and-miss damper). The damper in the spigot of the plenum box (at an extra charge) serves for easy air volume regulation. All models can be used in 100% to 40% VAV systems. The installation of the WGA-R-... in spiral ducts must take place free of stress. Avoid using unround or deformed spiral ducts, in order to protect the grilles from distortion. No return possible Version: 2018-03-08 Page 2

Processing I Accessories PROCESSING Frame -- sheet steel (-SB), painted to: - RAL colour 9010 (-9010, white, standard) - RAL colour 9005 (-9005, black) - RAL colour 9006 (-9006, white aluminium) - RAL colour 9007 (-9007, grey aluminium) - painted to RAL of your choice (-xxxx) Nozzles -- Plastic: - similar to RAL colour 9010 (-DW, white, standard) - similar to RAL colour 9005 (-DS, black) - similar to RAL colour 9006 (-DA, white aluminium) - similar to RAL colour 9007 (-DG, grey aluminium) Electric actuator -- for WGA-Q-VE- / WGA-R-VE- : - 230 V AC, 3-point activation (-E080) - 24 V AC, actuating signal Y, 0-10 V DC (-E081, standard) is fitted if no motor type is specified when ordering. - 24 V AC, 3-point activation (-E082). Thermocouple -- for WGA-Q-VT- / WGA-R-VT- ACCESSORIES Hit-and-miss damper (-SS) -- only possible without a plenum box. -- for regulating air volume made of galvanised sheet steel. -- Mounting exclusively ex works ball-impact guard (-BS) -- profiled steel (powder-coated in the same colour as the frame). Plenum box -- for WGA-Q-F0- / WGA-Q-V0- (-AK-37) -- for WGA-Q-VG- / WGA-Q-VT- (-AK-38) -- for WGA-Q-VE- (-AK-39) -- WGA-R- not possible -- Galvanised sheet steel -- Fastening: - screw mounting (-SM, standard) - concealed mounting (-VM) (-VM, only possible for AK- 37) Damper (-DK1) -- in the plenum box. -- damper made of galvanized sheet steel. -- damper fastening made of plastic. Rubber lip seal (-GD1) -- on the connection spigot of the plenum box, made of special rubber. Insulation -- inside (-Ii), thermal insulation at the inside of the plenum box. -- outside (-Ia), thermal insulation at the outside of the plenum box. VM counter pole brace (-GT) -- only possible for WGA-Q-F0-... and WGA-Q-V0-... -- only possible in the absence of a plenum box. -- pole brace made of galvanised sheet steel. -- supplied loose as standard. No return possible Version: 2018-03-08 Page 3

Models and dimensions I MODELS AND DIMENSIONS For installation in walls / ducts fixed nozzles WGA-Q-F0- Available sizes WGA-Q-F0- / WGA-Q-F0- -BS- L L1 L2 L3 H H1 H2 H3 325 358 309 310 125 158 109 111 425 458 409 410 225 258 209 211 525 558 509 510 325 358 309 311 625 658 609 610 825 858 809 810 1025 1058 1009 1010 1225 1258 1209 1210 All combined lengths and heights available. Special dimensions not available! Screw mounting (-SM) and concealed mounting (-VM) (-VM), see page 16. WGA-Q-F0- -SS- WGA-Q-F0- -BS- WGA-Q-F0- -SS-BS- No return possible Version: 2018-03-08 Page 4

Models and dimensions I For installation in walls / ducts individually adjustable nozzles WGA-Q-V0- Available sizes WGA-Q-V0- / WGA-Q-V0- -BS- L L1 L2 L3 H H1 H2 H3 325 358 309 310 125 158 109 111 425 458 409 410 225 258 209 211 525 558 509 510 325 358 309 311 625 658 609 610 825 858 809 810 1025 1058 1009 1010 1225 1258 1209 1210 All combined lengths and heights available. Special dimensions not available! Screw mounting (-SM) and concealed mounting (-VM) (-VM), see page 16. WGA-Q-V0- -SS- WGA-Q-V0- -BS- WGA-Q-V0- -SS-BS- No return possible Version: 2018-03-08 Page 5

Models and dimensions I For installation in walls / ducts nozzles jointly manually adjustable WGA-Q-VG- Available sizes WGA-Q-VG- / WGA-Q-VG- -BS- L L1 L2 H H1 H2 H3 325 358 319 125 158 109 110 425 458 419 225 258 209 210 525 558 519 625 658 619 825 858 819 1025 1058 1019 All combined lengths and heights available. Special dimensions not available! Screw mounting (-SM), see page 16. For model with a plenum box (AK-38 / AK-39), the length (L) of the installation opening increases by 5 mm. WGA-Q-VG- -SS- WGA-Q-VG- -BS- WGA-Q-VG- -SS-BS- No return possible Version: 2018-03-08 Page 6

Models and dimensions I For installation in walls / ducts electric block adjustment WGA-Q-VE- nozzles jointly adjustable via thermocouple without electrical energy WGA-Q-VT- electric actuator lateral central Available sizes (for WGA-Q-VE-... / WGA-Q-VE-SS- / WGA-Q-VE-BS- / WGA-Q-VE-SS-BS- ) H lateral centred L A L A 125 325-625 113 825 410 1025 510 625 310 225 325-525 113 825 410 1025 510 WGA-Q-VE-... / WGA-Q-VE-BS- / WGA-Q-VE-SS- / WGA- Q-VE-SS-BS- : Dimensions and available sizes WGA-Q-VE-... the same as WGA-Q-VG- (see page 6). For model with a plenum box (AK-39), the length (L) of the installation opening increases by 5 mm. Screw mounting (-SM), see page 16. Available sizes (for WGA-Q-VT-... / WGA-Q-VT-SS- / WGA-Q-VT-BS- / WGA-Q-VT-SS-BS- ) L A H B 325 62 125 115 425 162 225 118 525 162 625 262 825 362 1025 462 WGA-Q-VT-... / WGA-Q-VT-BS- / WGA-Q-VT-SS- / WGA- Q-VT-SS-BS- : Dimensions and available sizes WGA-Q-VT-... the same as WGA-Q-VG- (see page 6). For model with a plenum box (AK-38), the length (L) of the installation opening increases by 5 mm. Screw mounting (-SM), see page 16. With WGA-Q-VE-... Observe actuator mounting! List of actuators: Actuator -E080 Gruner 309-230-150/SL8 -E081 Gruner 309C-024-150/SL8 -E082 Gruner 309-024-150/SL8 No return possible Version: 2018-03-08 Page 7

Models and dimensions I For installation in round ducts fixed nozzles WGA-R-F0- Available sizes WGA-R-F0- / WGA-R-F0- -BS- L L1 L2 L3 H H1 H2 H3 325 358 309 310 115 108 109 111 425 458 409 410 215 208 209 211 525 558 509 510 625 658 609 610 825 858 809 810 1025 1058 1009 1010 1225 1258 1209 1210 All combined lengths and heights available. Special dimensions not available! For ød, see installation situation page 12. Screw mounting (-SM), see page 16. WGA-R-F0- -SS- WGA-R-F0- -BS- WGA-R-F0- -SS-BS- No return possible Version: 2018-03-08 Page 8

Models and dimensions I For installation in round ducts individually adjustable nozzles WGA-R-V0- Available sizes WGA-R-V0- / WGA-R-F0- -VS- L L1 L2 L3 H H1 H2 H3 325 358 309 310 115 108 109 111 425 458 409 410 215 208 209 211 525 558 509 510 625 658 609 610 825 858 809 810 1025 1058 1009 1010 1225 1258 1209 1210 All combined lengths and heights available. Special dimensions not available! For ød, see installation situation page 12. Screw mounting (-SM), see page 16. WGA-R-V0- -SS- WGA-R-V0- -BS- WGA-R-V0- -SS-BS- No return possible Version: 2018-03-08 Page 9

Models and dimensions I For installation in round ducts nozzles jointly manually adjustable WGA-R-VG- Available sizes WGA-R-VG- / WGA-R-VG- -BS- L L1 L2 H H1 H2 H3 325 358 319 115 108 109 110 425 458 419 215 208 209 210 525 558 519 625 658 619 825 858 819 1025 1058 1019 All combined lengths and heights available. Special dimensions not available! For ød, see installation situation page 12. Screw mounting (-SM), see page 16. WGA-R-VG- -SS- WGA-R-VG- -BS- WGA-R-VG- -SS-BS- No return possible Version: 2018-03-08 Page 10

Models and dimensions I For installation in round ducts electric block adjustment WGA-R-VE- nozzles jointly adjustable via thermocouple without electrical energy WGA-R-VT- electric actuator lateral central electric actuator for WGA-R-VE-... / WGA-R-VE-SS- / WGA- R-VE-BS- / WGA-R-VE-SS-BS- : H lateral centred L A L A 115 325-625 113 825 410 1025 510 625 310 215 325-525 113 825 410 1025 510 Dimensions and available sizes WGA-Q-VE-... the same as WGA-R-VG- (see page 10). Screw mounting (-SM), see page 16. Available sizes (for WGA-R-VT-... / WGA-R-VT-SS- / WGA- R-VT-BS- / WGA-R-VT-SS-BS- ) L A H W B1 325 62 115 115 117 425 162 215 118 217 525 162 625 262 B1= duct opening 825 362 1025 462 Dimensions and available sizes WGA-R-VT-... the same as WGA-R-VG- (see page 10). Screw mounting (-SM), see page 16. Bei WGA-R-VE-... Observe actuator mounting! List of actuators: Actuator -E080 Gruner 309-230-150/SL8 -E081 Gruner 309C-024-150/SL8 -E082 Gruner 309-024-150/SL8 No return possible Version: 2018-03-08 Page 11

Quick selection I Installation situation QUICK SELECTION Height H (mm) 115 125 215 225 325 325 Length L (mm) 425 525 625 825 1025 WGA-Q-F0- -- X -- X X X X X X X X X WGA-Q-V0- -- X -- X X X X X X X X X WGA-Q-VG- -- X -- X -- X X X X X X -- WGA-Q-VE- -- X -- X -- X X X X X X -- WGA-Q-VT- -- X -- X -- X X X X X X -- WGA-R-F0- X -- X -- -- X X X X X X X WGA-R-V0- X -- X -- -- X X X X X X X WGA-R-VG- X -- X -- -- X X X X X X -- WGA-R-VE- X -- X -- -- X X X X X X -- WGA-R-VT- X -- X -- -- X X X X X X -- X = available / -- = not available 1225 INSTALLATION SITUATION WGA-R-F0- / WGA-R-V0- / WGA-R-VG- / WGA-R-VE- / WGA-R-VT- H Ød (mm) min. ideal max. 115 300 500 800 215 600 750 1100 The grilles only lie completely flush with ideal duct diameter. Duct diameter Apart from high stability and torsional rigidity, the diagonal flange and the two height dimensions allow an optimum adjustment of the long throw nozzle grilles type WGA-R-... to sheet steel or spiral ducts. The selection of the grille height depends on the duct measures shown in the table. The installation of the WGA-R-... in spiral ducts must take place free of stress. Avoid using unround or deformed spiral ducts, in order to protect the grilles from distortion. No return possible Version: 2018-03-08 Page 12

Band design I Installation situation BAND DESIGN Only possible for WGA-Q-F0-... and WGA-Q-V0-... Long throw nozzle grille classification valid for SM and VM mounting. Band design is also possible without a plenum box. Dimensions + prices with hit-and-miss damper upon request. 2-part if length of band BL 2025 mm 2.) 1.) multi-part for a band length BL > 2025 mm 2.) 1.) Spigot in the plenum box for end pieces without spigot: KL = <120mm or < (ød+90) with spigot: KL = (ød + 90) up to 1000 1.) = Indentation for slotted shallow-raised countersunk-head tapping screw DIN ISO 7051 pitch 3.9 (on site) (with SM mounting only) 2.) = from ES 625 mm (only with SM mounting) BL = Length of band KL = Plenum box length ES = End piece TS = Section DIF = Difference distance EÖL = Ceiling opening dimensions No return possible Version: 2018-03-08 Page 13

Dimensions of accessories I DIMENSIONS OF ACCESSORIES Plenum box (-AK) with lateral spigot (-S1), only for WGA-Q- AK-37- -S1: for WGA-Q-F0-... / WGA-Q-V0-... AK-38- -S1: for WGA-Q-VG-... / WGA-Q-VT-... AK-39- -S1: for WGA-Q-VE- Grilles cannot be fitted with a hit-and-miss damper if a plenum box is attached, i.e., it can either be fitted with a hitand-miss damper or a plenum box. Spigot arrangement KL = length of box KB = width of box outside As-delivered condition with fitted fixing lug X On site with bent fixing lug X - lateral spigot, KL central (-S1, standard) - spigot from above, KL central (-S0) - spigot front side, KB central (-S4) Dimensions and prices for spigot from above (-S0) and spigot front side (-S4) upon request. Spigot diameters for spigot from above (-S0) and spigot front side (-S4) deviate from the standard plenum box (AK-37- - S1). Available sizes AK-37-...-S1 (for WGA-Q-F0-... / WGA-Q-V0-...) H KBS L KL KH Ød 325 320 245 158 425 420 245 158 525 520 245 158 125 118 625 620 245 158 825 820 285 198 1025 1020 285 198 1225 1220 285 198 325 320 285 198 425 420 285 198 525 520 285 198 225 218 625 620 335 248 825 820 335 248 1025 1020 335 248 1225 1220 335 248 325 320 335 248 425 420 335 248 525 520 335 248 325 318 625 620 400 313 825 820 400 313 1025 1020 400 313 1225 1220 400 313 AK-38-...-S1 (for WGA-Q-VG-... / WGA-Q-VT-...) H KBS L KL KH Ød 325 325 325 158 425 425 325 158 125 118 525 525 325 158 625 625 325 158 825 825 365 198 1025 1025 365 198 325 325 365 198 425 425 365 198 225 218 525 525 365 198 625 625 415 248 825 825 415 248 1025 1025 415 248 AK-39-...-S1 (for WGA-Q-VE-...) H KBS L KL KH Ød 325 325 345 158 425 425 345 158 125 118 525 525 345 158 625 625 345 158 825 825 385 198 1025 1025 385 198 325 325 385 198 425 425 385 198 225 218 525 525 385 198 625 625 435 248 825 825 435 248 1025 1025 435 248 No return possible Version: 2018-03-08 Page 14

Dimensions of accessories I Damper (-DK1) When ordering a plenum box (-AK) with damper (-DK1), the box height (KH) of AK-37 will be different. AK-37- -DK1: KH + 80 mm AK-38- -DK1: KH + 0 AK-39- -DK1: KH + 0 Rubber lip seal (-GD1) Detail Y Insulation for plenum box AK Internal insulation (-Ii) External insulation (-Ia) No return possible Version: 2018-03-08 Page 15

Fastening methods I FASTENING METHODS Concealed mounting (-VM) only possible for WGA-Q-F0-... and WGA-Q-V0-... With a plenum box (-AK) Screw mounting (-SM, standard) For installation in walls / ducts WGA-Q-... 1.) 1.) Position of the pole braces L-325-L625 = external nozzle L-825-L1225 = second nozzle from the outside For concealed mounting, two VM counter pole braces are mounted in the plenum box. The long throw nozzle grille is mounted to the plenum box using two (with H=125) or four (with H=225/325) socket head screws DIN ISO 4762 M6. 4.) 3.) 3.) Indentation for slotted shallow-raised countersunk-head tapping screw DIN ISO 7051 pitch 3.9 (on site) (with SM mounting only) 4.) from L 625 mm For installation in round ducts WGA-R-... Long throw nozzle grille with hit-and-miss damper is not available with concealed mounting. Without a plenum box VM counter pole brace (-GT, pair, supplied loose) only possible for WGA-Q-F0-... and WGA-Q-V0-... 6.) 5.) 5.) ø4.5 6.) from L 625 mm 2.) 2.) Riveting nut M6 Number of riveting nuts (EM) / fastening screws (BS): H = 125 per counter pole brace 1 x EM / 1 x BS H = 225 / 325 per counter pole brace 2 x EM / 2 x BS Available sizes VM counter pole brace (-GT) H H1 H2 125 140 193 225 240 293 325 340 393 No return possible Version: 2018-03-08 Page 16

Technical data I TECHNICAL DATA Pressure loss and noise level WGA-...-F0-..., WGA-...-V0-..., WGA-...-VG-... (L=1225 not for model WGA- -VG, H=325 only for model WGA-Q-F0- / WGA-Q-V0- ) without-hit-and miss damper, straight inflow ρ=1,2 kg/m³ Face area [A Stirn (m²)] H 325 425 525 625 825 1025 1225 125 0.0310 0.0412 0.0514 0.0616 0.0820 0.1024 0.1262 225 0.0614 0.0816 0.1018 0.1220 0.1624 0.2028 0.2464 325 0.0918 0.1220 0.1522 0.1824 0.2428 0.3032 0.3666 Height 125/225/325 = height 115/215/315 L Correction factor (KF) Astirn (m²) 0.032 0.040 0.051 0.064 0.080 0.100 0.128 0.160 0.203 0.256 0.320 0.367 KF (-) - 5-4 - 3-2 - 1 0 + 1 + 2 + 3 + 4 + 5 +6 without hit-and-miss damper Installation in main stream of duct L WA = L WA1 + KF ρ=1,2 kg/m³ Effective velocity WGA-...-F0-..., WGA-...-V0-..., WGA-...-VG-... (L=1225 not for model WGA- -VG, H=325 only for model WGA-Q-F0- / WGA-Q-V0- ) with hit-and-miss damper SS (100% OPEN) Installation in main stream of duct ρ=1,2 kg/m³ SS 50 % OPEN: Δpt 50% = Δpt 100% x 1.42 Height 125/225/325 = height 115/215/315 No return possible Version: 2018-03-08 Page 17

Technical data I Maximum end velocity of jet WGA-...-F0-..., WGA-...-V0-..., WGA-...-VG-... (L=1225 not for model WGA- -VG, H=325 only for model WGA-Q-F0- / WGA-Q-V0- ) without coanda effect Height 125/225/325 = height 115/215/315 No return possible Version: 2018-03-08 Page 18

Technical data I WGA-...-F0-..., WGA-...-V0-..., WGA-...-VG-... (L=1225 not for model WGA- -VG, H=325 only for model WGA-Q-F0- / WGA-Q-V0- ) Maximum end velocity of jet (isotherm) with coanda effect Height 125/225/325 = height 115/215/315 No return possible Version: 2018-03-08 Page 19

Technical data I Jet path WGA-...-F0-..., WGA-...-V0-..., WGA-...-VG-... (L=1225 not for model WGA- -VG, H=325 only for model WGA-Q-F0- / WGA-Q-V0- ) Free jet without coanda effect Height 125/225/325 = height 115/215/315 No return possible Version: 2018-03-08 Page 20

Technical data I Critical throw WGA-...-F0-..., WGA-...-V0-..., WGA-...-VG-... (L=1225 not for model WGA- -VG, H=325 only for model WGA-Q-F0- / WGA-Q-V0- ) with coanda effect (in cooling mode) Maximum penetration WGA-...-F0-..., WGA-...-V0-..., WGA-...-VG-... (L=1225 not for model WGA- -VG, H=325 only for model WGA-Q-F0- / WGA-Q-V0- ) (in heating mode) Height 125/225/325 = height 115/215/315 Height 125/225/325 = height 115/215/315 No return possible Version: 2018-03-08 Page 21

Technical data I Induction ratio WGA-...-F0-..., WGA-...-V0-..., WGA-...-VG-... (L=1225 not for model WGA- -VG, H=325 only for model WGA-Q-F0- / WGA-Q-V0- ) without coanda effect WGA-...-F0-..., WGA-...-V0-..., WGA-...-VG-... (L=1225 not for model WGA- -VG, H=325 only for model WGA-Q-F0- / WGA-Q-V0- ) Maximum end velocity of jet (isotherm) with coanda effect Height 125/225/325 = height 115/215/315 No return possible Version: 2018-03-08 Page 22

Technical data I Temperature ratio WGA-...-F0-..., WGA-...-V0-..., WGA-...-VG-... (L=1225 not for model WGA- -VG, H=325 only for model WGA-Q-F0- / WGA-Q-V0- ) without coanda effect WGA-...-F0-..., WGA-...-V0-..., WGA-...-VG-... (L=1225 not for model WGA- -VG, H=325 only for model WGA-Q-F0- / WGA-Q-V0- ) Maximum end velocity of jet (isotherm) with coanda effect Height 125/225/325 = height 115/215/315 No return possible Version: 2018-03-08 Page 23

Technical data I Minimum distances recommended WGA-...-F0-..., WGA-...-V0-..., WGA-...-VG-... without coanda effect WGA-...-F0-..., WGA-...-V0-..., WGA-...-VG-... Maximum end velocity of jet (isotherm) with coanda effect If the selected minimum distance "z" is less than (x 0.2), the grille is referred to as a continuous grille Connection diagrams of electric actuators Make Gruner -E080 (309-230-150/SL8) / -E082 (309-024-150/SL8) OPEN/CLOSED control N L Make Gruner -E081 (309C-024-150/SL8) (standard) DC 0... 10 V DC 2... 10 V 3-point control N L Technical data of electric actuators Make Gruner -E080 (309-230-150/SL8) Rated voltage: AC 230 V/ DC 230 V, 50 / 60 Hz Functional range: AC 85... 265 V Power consumption - Operation: - Idle position: - Dimensioning: Torque (rated torque): Sound power level: Protection class: Degree of protection: EMC: Low voltage directive: Ambient temperature: -20... +50 C 3.0 W @ nominal torque 1.0 W 5.5 VA Min. 10 Nm at the rated voltage max. 35 db (A) II protective insulation IP42 in all mounting positions CE according to 2004 / 108 / EC CE according to 2006 / 65 / EC Make Gruner -E081 (309C-024-150/SL8) (standard) Rated voltage: AC 24 V / DC 24 V, 50 / 60 Hz Functional range: AC / DC 19... 29 V Power consumption - Operation: - Idle position: - Dimensioning: Torque (rated torque): Sound power level: Activation - Actuator signal Y: 2.5 W @ nominal torque 1.5 W 5.0 VA Min. 10 Nm at the rated voltage max. 35 db (A) DC 0(2)... 10 V, input resistance typically 100 kω - Operating range: DC 2... 10 V Positional feedback (Measuring voltage U): DC 2... 10 V, max. 0.5 ma Protection class: IIl safety extra low voltage Degree of protection: IP42 in all mounting positions EMC: CE according to 2004 / 108 / EC Ambient temperature: -20... +50 C Make Gruner -E082 (309-024-150/SL8) Rated voltage: AC / DC 24 V, 50 / 60 Hz Functional range: AC / DC 19... 29 V Power consumption - Operation: - Idle position: - Dimensioning: Torque (rated torque): Sound power level: Protection class: Degree of protection: EMC: Ambient temperature: -20... +50 C 2 W @ nominal torque 1.5 W 3.5 VA Min. 10 Nm at the rated voltage max. 35 db (A) Safety extra low voltage III IP42 in all mounting positions CE according to 2004 / 108 / EC Note: For further information on the actuators refer to the technical documents of Gruner. No return possible Version: 2018-03-08 Page 24

Legend I LEGEND V ZU (m 3 /h) [l/s] = supply air volume V X (m³/h) [l/s] = total air jet volume at point x v max (m/s) = max. End velocity of jet x (m) = horizontal throw y (m) = vertical throw x+y (m) = horizontal + vertical throw x kr (m) = critical throw y H (m) = maximum penetration depth in heating mode ΔT O (K) = temperature difference between supply air temperature and room temperature (ΔT O = t ZU - t R ) ΔT X (K) = temperature difference at point x t ZU ( C) = supply air temperature t R ( C) = room temperature Δp t (Pa) = pressure loss v eff (m/s) = effective throw velocity v K (m/s) = duct velocity A stirn (m 2 ) = face area KF (-) = Correction factor L WA [db(a)] = A-weighted sound power level L WA1 [db(a)] = A-weighted sound power level, relative to one parameter ρ (kg/m 3 ) = density i (-) = induction ratio (i = V X / V ZU ) TV (-) = temperature ratio (TV = ΔT X / ΔT O ) RH (mm) = room height RB (mm) = room width L (mm) = length H (mm) = Height z (m) = minimum clearance between two grilles x (m) 0.2 No return possible Version: 2018-03-08 Page 25

Order code I ORDER CODE 01 02 03 04 05 06 Type Model Nozzle position Length Height Single / band design Example WGA -Q -F0-00425 -125 -N 07 08 09 10 11 12 13 Material Paint Nozzle colour Fastening hit-and-miss damper Ball-impact guard Actuator Example -SB -9010 -DS -VM -SN -B0 -E000 Sample WGA-Q-F0-00425-125-N-SB-9010-DS-VM-SN-B0-E000 Long throw nozzle grille type WGA I for installation in walls and ducts I fixed nozzles I grille length 425 mm I grille height 125 mm I single length I sheet steel I painted to RAL9010 I nozzles black similar to RAL9005 I with concealed mounting I without hit-and-miss damper I without ball-impact guard I without actuator ORDER DETAILS 01 - Type WGA = long throw nozzle grille type WGA 02 Model Q = for installation in walls and ducts R = for installation in round ducts 03 - Nozzle position F0 = with fixed nozzles V0 = with individually manually adjustable nozzles VG = with jointly manually adjustable nozzles VE = with jointly electrically adjustable nozzles VT = with jointly thermally adjustable nozzles 04 - Length 00325 = grille length 325 mm 00425 = grille length 425 mm 00525 = grille length 525 mm 00625 = grille length 625 mm 00825 = grille length 825 mm 01025 = grille length 1025 mm 01225 = grille length 1225 mm (only possible for WGA-Q- F0-... / WGA-Q-V0-... / WGA-R-F0-... / WGA-R-V0-...) xxxxx = band design > 1225 mm (always with 5 digits) 05 - Height 115 = 1 row with WGA-R-... 125 = 1 row with WGA-Q-... 215 = 2 rows with WGA-R-... 225 = 2 rows with WGA-Q-... 325 = 3 rows (only possible for WGA-Q-F0-... / WGA-Q- V0-...) 06 - Single / band design N = Single length B = Length of band (only possible for WGA-Q-F0- and WGA-Q-V0- ) 07 - Material SB = sheet steel (standard) 08 Paint 9010 = painted to RAL9010 (white, standard) 9005 = painted to RAL9005 (black) 9006 = painted to RAL9006 (white aluminium) 9007 = painted to RAL9007 (grey aluminium) xxxx = painted to RAL of your choice (always with 4 dig its) 09 - Nozzle colour DW = white similar to RAL9010 (standard) DS = black similar to RAL9005 DA = white aluminium similar to RAL9006 DG = grey aluminium similar to RAL9007 10 - Fastening SM = screw mounting (standard) VM = concealed mounting (only possible for WGA-Q-F0- and WGA-Q-V0- ) GT = VM counter pole brace (only possible in the absence of a plenum box) (only possible for WGA-Q- F0- and WGA-Q-V0- ) 11 - Hit-and-miss damper SN = Without hit-and-miss damper (standard) SS = with hit-and-miss damper (-SS-K) (only possible without a plenum box) 12 Ball-impact guard B0 = without ball-impact guard (standard) BS = with ball-impact guard 13 Actuator E000 = without actuator (standard) E080 = with actuator 230 V AC, 3-point E081 = with actuator 24 V AC, 0-10 V DC E082 = with actuator 24 V AC, 3-point No return possible Version: 2018-03-08 Page 26

Plenum box order code I PLENUM BOX ORDER CODE 01 02 03 04 05 06 07 08 Type Air diffuser Length Height Single / band design Fastening Material Damper Example AK -37-00425 -125 -N -SM -SV -DK1 09 10 11 12 13 14 Rubber lip seal Insulation Height of plenum box Width of box Spigot diameter Spigot position -GD1 -I0 -KHS -KBS -SDS -S1 Sample AK-37-00425-125-N-SM-SV-DK1-GD1-I0-KHS-KBS-SDS-S1 Plenum box, rectangular design I suitable for diffuser type WGA-Q-F0-... / WGA-Q-V0-... I length 425 mm I height 125 mm I single length I with screw mounting I galvanised sheet steel I with damper I with rubber lip seal I without box insulation I standard height of box I standard width of box I spigot diameter standard I lateral spigot ORDER DETAILS 01 - Type AK = plenum box, rectangular design 02 - Air diffuser 37 = for long throw nozzle grille type WGA-Q-F0-... / WGA-Q-V0-... 38 = for long throw nozzle grille type WGA-Q-VG-... / WGA-Q-VT-... 39 = for long throw nozzle grille type WGA-Q-VE-... 03 - Length 00325 = grille length 325 mm 00425 = grille length 425 mm 00525 = grille length 525 mm 00625 = grille length 625 mm 00825 = grille length 825 mm 01025 = grille length 1025 mm 01225 = grille length 1225 mm (only possible for WGA-Q- F0-... / WGA-Q-V0-...) xxxxx = band design > 1225 mm (always with 5 digits) 04 - Height 125 = 1 row 225 = 2 row 325 = 3 row (only possible for WGA-Q-F0-... and WGA- Q-V0-...) 05 - Single / band design N = single length (standard) B = band design (module length max. 1500mm) 06 - Fastening SM = screw mounting (standard, screws must be provided on site) VM = concealed mounting (only possible for AK-37) 08 Damper DK0 = without damper (standard) DK1 = with damper 09 - Rubber lip seal GD0 = without rubber lip seal (standard) GD1 = with rubber lip seal 10 - Insulation l0 = without insulation (standard) Ii = with box insulation inside Ia = with box insulation outside 11 Height of plenum box KHS = standard height of box xxx = height of box in mm (minimum height = spigot diameter + 72 mm, always with 3 digits) 12 - Width of box KBS = standard width of box xxx = width of box in mm (minimum width = spigot diameter + 30 mm, always with 3 digits) 13 Spigot diameter SDS = standard spigot diameter xxx = spigot diameter in mm (always with 3 digits) 14 Spigot position S0 = Spigot from above S1 = lateral spigot on the box (standard) S4 = spigot front side (not possible with band design) 07 - Material SV = galvanised sheet steel (standard) No return possible Version: 2018-03-08 Page 27

Specification texts I SPECIFICATION TEXTS Long throw nozzle grille type WGA-Q-F0- particularly suitable for air-conditioning of high and large rooms such as multipurpose halls. High-induction supply air intake through several nozzles of high throw speeds at low sound power level, to achieve long throws and efficient throw pattern through optimum nozzle shape. High flexibility through a wide range of installation options. Installation in walls, ceilings, plenum boxes and ducts. Cooling and heating modes are possible. Suitable for use in 100% to 40% VAV systems. Housing consisting of sheet steel painted with a high-quality powder coating to a RAL colour (RAL 9010 [white, standard], RAL 9005 [black], RAL 9006 [white aluminium], RAL 9007 [grey aluminium] or a freely selectable RAL colour). Fixed nozzles made of plastic, similar to RAL colour RAL 9010 (-DW, white, standard), RAL 9005 (-DS, black), RAL 9006 (-DA, white aluminium) or RAL 9007 (-DG, grey aluminium). With visible screw fixing (standard, -SM) or concealed mounting (-VM). Product: SCHAKO type WGA-Q-F0-... - Installation in walls, ceilings, plenum boxes and ducts, with individually manually adjustable nozzles, pivoting range 45, without change in the sound power level and pressure loss upon adjustment. With visible screw fixing (standard, -SM) or concealed mounting (-VM). Product: SCHAKO type WGA-Q-V0-... - as a band (-B) (only possible for WGA-Q-F0- / WGA-Q-V0- ) - 2-part (BL 2025) - multi-part (BL > 2025) Accessories: - with ball-impact guard (-BS), integrated into the housing made of profiled steel (powder-coated in the same colour as the housing). - with hit-and-miss damper (-SS) for volumetric flow adjustment, adjustable on room side, made of electrolytically galvanized sheet steel (not possible in connection with AK and VM). - with plenum box (-AK) made of galvanized sheet steel, with lateral connection spigot - with damper (-DK1) in plenum box, adjustable from below, for simple air volume regulation without dismounting the grille. - with rubber lip seal (-GD1), on plenum box, made of special rubber. - with thermal insulation - internal (-li) - external (-la) - VM counter pole brace made of galvanised sheet steel. - VM counter pole brace (-GT, pair), made of galvanised sheet steel (only possible in the absence of AK, only possible for WGA-Q-F0- and WGA-Q-V0- ). - Installation in walls, ceilings, plenum boxes and ducts, with jointly manually adjustable nozzles, pivoting range 34, without change in the sound power level and pressure loss upon adjustment. With visible screw fixing (-SM). Product: SCHAKO type WGA-Q-VG-... - Installation in walls, ceilings, plenum boxes and ducts, with jointly motor-adjustable nozzles, pivoting range 34, without change in the sound power level and pressure loss upon adjustment. With visible screw fixing (-SM). With electric actuator: - 3-point activation (-E080) 230 V AC - Actuator signal Y, 24 V AC, 0-10 V DC (-E081) (standard) - 3-point activation (-E082) 24 V AC. Product: SCHAKO type WGA-Q-VE-... - Installation in walls, ceilings, plenum boxes and ducts, with nozzles jointly adjustable via thermocouple, pivoting range 34, without change in the sound power level and pressure loss upon adjustment - without electrical energy. At a supply air temperature of 20 C or lower, the nozzles are in the cooling position with throw direction diagonally upwards (max. angle 17 ). At a supply air temperature of 35 C or higher, the nozzles are in the heating position with throw direction diagonally upwards (max. angle -17 ). In the temperature range between 20 C and 35 C, the nozzle row is adjusted linearly. With visible screw fixing (-SM). Product: SCHAKO type WGA-Q-VT-... No return possible Version: 2018-03-08 Page 28

Specification texts I Long throw nozzle grille type WGA-R-F0- particularly suitable for air-conditioning of high and large rooms such as multi-purpose halls. High-induction supply air intake through several nozzles of high throw speeds at low sound power level, to achieve long throws and efficient throw pattern through optimum nozzle shape. Installation in round ducts. Cooling and heating modes are possible. Suitable for use in 100% to 40% VAV systems. Housing consisting of sheet steel painted with a high-quality powder coating to a RAL colour (RAL 9010 [white, standard], RAL 9005 [black], RAL 9006 [white aluminium], RAL 9007 [grey aluminium] or a freely selectable RAL colour). Fixed nozzles made of plastic, similar to RAL colour RAL 9010 (-DW, white, standard), RAL 9005 (-DS, black), RAL 9006 (-DA, white aluminium) or RAL 9007 (-DG, grey aluminium). With visible screw fixing (-SM). Product: SCHAKO type WGA-R-F0-... Accessories: - with ball-impact guard (-BS), integrated into the housing made of profiled steel (powder-coated in the same colour as the housing). - with hit-and-miss damper (-SS) for volumetric flow adjustment, adjustable on room side, made of electrolytically galvanized sheet steel. (not possible in connection with AK). - Installation in round ducts, with individually manually adjustable nozzles, pivoting range 45, without change in the sound power level and pressure loss upon adjustment. With visible screw fixing (-SM). Product: SCHAKO type WGA-R-V0-... - Installation in round ducts, with jointly manually adjustable nozzles, pivoting range 34, without change in the sound power level and pressure loss upon adjustment With visible screw fixing (-SM). Product: SCHAKO type WGA-R-VG-... - Installation in round ducts, with jointly motor-adjustable nozzles, pivoting range 34, without change in the sound power level and pressure loss upon adjustment. With visible screw fixing (-SM). With electric actuator: - 3-point activation (-E080) 230 V AC. - Actuator signal Y, 24 V AC, 0-10 V DC (-E081) (standard) - 3-point activation (-E082) 24 V AC. Product: SCHAKO type WGA-R-VE-... - Installation in round ducts with nozzles jointly adjustable via thermocouple, pivoting range 34, without change in the sound power level and pressure loss upon adjustment - without electrical energy. At a supply air temperature of 20 C or lower, the nozzles are in the cooling position with throw direction diagonally upwards (max. angle 17 ). At a supply air temperature of 35 C or higher, the nozzles are in the heating position with throw direction diagonally upwards (max. angle -17 ). In the temperature range between 20 C and 35 C, the nozzle row is adjusted linearly. With visible screw fixing (-SM). Product: SCHAKO type WGA-R-VT-... No return possible Version: 2018-03-08 Page 29