FC/APC Patchcord FC/APC. Insertion Loss(Reference plug) Insertion Loss (Random mated) Return Loss

Similar documents
LC Cable Assemblies. Fiber Optic Products Catalog. Product Facts. LC Cable Assembly. Hybrid LC-SC Cable Assembly

S Ingle Mode Fiber Patch Cord and Pigtail (SC/APC, LC/APC)

Introduction to Fiber Cable Assemblies FiberDeep and Cable Assemblies

Armored Fiber Optic Patch Cord for Emergency & Mobile Emergency Repair Equipment. ENSE - European Network Systems Engineering - 1 -

MTP Loose Tube Trunk Assemblies. Features. Applications.

Indoor/Outdoor Cables Single-Armored, Plenum, Tight Buffered Distribution Indoor/Outdoor Cable

40G QSFP+ (MPO) to 4x10G SFP+ (8xLC) Assembly

MPO MicroCable Trunk Assembly

Fiber Optic, Breakout cable, tight buffered, 900 microns

Fiber Cables & Hardware

FIBER PIGTAIL/PATCHCORDS

Application Specification. Optical Fiber. Aramid Yarns. 2mm Subunit Jacket. Strength Rods. Outer Jacket

Mining and Petrochemical Tray-Rated Fiber Optic Cables

Mini USB and USB 2.0-IP67 Connector System

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

Optical Fibre Fibre Cables

FAST-SC Connector. Any questions should be directed to AFL Telecommunications.

Basic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S

LX2 High Density LGX 4U Patch Panel

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

LX2 High Density LGX 4U Patch Panel

Volition Fiber Optic Cable

DNV-GL HH CE RoHS-II conform

CONEC provides reliable and effective solutions to OEM, EMS and cable houses.

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

ENTERPRISE FIBER OPTIC CABLE. Interconnect Indoor Indoor/Outdoor Outdoor ADSS MicroCore

Volition. Fiber Optic Cable. 3Innovation

Part Number: 10GX F/UTP CMR PATCH CORDS 10GX F/UTP CMR Patch Cords

ENTERPRISE FIBER OPTIC CABLE. Interconnect Indoor Indoor/Outdoor Outdoor ADSS MicroCore

FIBER INSIDE PLANT. Rack Mount Panels Optical Modules Cable Assemblies Components

Centrix System. Features and Benefits

FITEL S178 Ver.2 Hand-held Core-Alignment Fusion Splicer

UMA Fiber Optic Modular Adapter System Flexibility in a 2-Piece Adapter System

FIBER OPTIC CABLE ASSEMBLIES ECO RANGE

MIL-PRF type fiber optic termini F722 - F724

MIC Plenum Cables, 2-24 Fibers

Plug & Play AnyLAN Systems

MIC Unitized Plenum Cables, Fibers

User s Guide Power / Wave Measurement Heads OMH-6780B OMH-6790B

Radiall company profile

USB3.0 for Active Optical Cable

Inspection and Cleaning Procedures for Fiber-Optic Connections

Tender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read

50µm µlinx Avionics Cable

Sealed Sensor Connector (SSC) System

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

Caledonian Fire Resistant Optic Fiber Cables

INSTALLATION INSTRUCTIONS

fiber optic cable Outdoor Cables

Get Fiber Smart. Part 1 : Best Practices in Enterprise Fiber Connectivity. Part 3: Best Practices in Tier2 Enterprise Fiber Link Testing and

Interconnect Cable Simplex and Duplex

Avionics Optical Cables

Part Number: CAT6+ UTP CMR PRE-TERM 6 CAT6+ UTP CMR Pre-Term 6

SPEC SHEET. OmniReach FTTX Solutions. NEMA Fiber Demarcation Box (FDB) Features

DOCUMENT OBSOLETE. Volition. VF-45 Socket Termination and Maintenance Cleaning Kits COOL HAND TOOLS. CLEAN UP YOUR ACT. VF-45 Socket Termination Kit

ezprep Gel-Free Loose Tube Gel-Free Loose Tube Cable (2.5mm)

Laser Optimized Multimode

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

Volition. VF-45 Quick Install kit. and Maintenance Cleaning Kit. 3Innovation

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

ezspan ADSS Short Span All-Dielectric Self-Support Loose Tube Cable

Luminus Series Amphenol Pcd

USB3.0 For Active Optical Cable SPECIFICATIONS

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Swing-Out Style Fiber Distribution Units

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

USB3.0 For Active Optical Cable SPECIFICATIONS

Fi b e r Op t i c So l u t i o n s

Reliability & Qualification Report for MEMS Based Variable Optical Attenuators

S123 v2 Fusion Splicers Hand-Held Clad Alignment Fusion Splicer

SNP-8 Series Single mode FC CONNECTOR PLUG - for Angled-PC, Conical Shape -

6000 Series Ethernet Buccaneer

SW1 Swivel 1U Patch Panel

Outlets terminate all shielded and shielded cable constructions AWG ( mm) size conductors.

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Technical Data Sheet VENUS FLA SCM

No. Tool Vendor P/N. Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL.

OBIS Galaxy. Fiber Input, Fiber Output, Eight Channel Beam Combiner. Superior Reliability & Performance. OBIS Galaxy Features: Compact and low profile

Ethernet Buccaneer BUCCANEER DATA. bulgin

HL (AZH) LIMIT SWITCHES

Data sheet chainflex CF886

Instructions for Use - Opt-X 1000i Enclosure

Enhanced Management Frame (EMF)

SW1 Swivel 3U Patch Panel

Technical Data Sheet Unshielded (YY) PVC Control Cable

D-Subminiature EMI/RFI Shielding Interconnection Systems

Ethernet Buccaneer IP68 BUCCANEER FOR DATA BUCCANEER DATA

2001 PRODUCT CA T ALOG

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

Data sheet chainflex CF881

(TRWL) Wire Wound Chip Ceramic Inductor

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

All In One Fusion Splicer

INSTALLATION RULES for SCS/SENSOR Pt100

RA19 Cable Management, 5 hooks

series 2-Stage Servovalve Rated flows up to 80 l/m Features

STFOC Optical Cable. Non-Kink Crush Proof

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut

P R O D U C T C AT A L O G T ALOG

Opticom Rack Mount Fiber Enclosures

Transcription:

FC/APC Patchcord FC/APC patchcord are mainly used in telecom network, especially in CATV, Local Area Networks (LAN) or FTTX networks. The requirement of insertion loss and return loss requirement was maintained at a high level to ensure a future proof network. FC/APC patchcord series is produced in a cost-effective and rigid production process under controlled processes to ensure long-term stability and reliability. 1 TOLERANCES OF LENGTH (mm) L 50000 + 50 / - 50 50000 2 Standard lengths for patch cords and pigtails are 1, 2, 3, 5,10 meters and customized. 3 The diameters (ΦD) of the cable are 0.9,2.0,3.0mm. Color scheme Connector House Boot FC/APC silvery green Material House Spring Ferrule Phosphor bronze Stainless steel Phosphor bronze and Zirconia 1 The materials of connector are all in accordance with RoHS-directive. 2 Connector and hood Plastic, non flammable (UL94-V-0) 3 The dimension meet IEC 60874-14 The preferred cable color is yellow, other colors can be customized. 0.9/2.0/3.0mm, tight secondary coating and jacket are made of flame retardant material. Insertion Loss measurement test against reference connectors are intended to be used when quality conformance is required. Random mating attenuation test shall be used during qualification to ensure that the optical performance requirements are met. Insertion Loss(Reference plug) Insertion Loss (Random mated) Return Loss FC/APC 0.30dB 0.50dB 60dB

Connectors are manufactured in a controlled process to ensure ferrule endface geometry after termination and polishing. All geometrical parameters are defined in IEC 61753-3-1 to meet specific requirement for fiber-to-fiber interconnection and ensure a stable optical performance. FC/APC Radius of Curvature 5~15mm Apex Offset 50μm Fiber Height(Spherical) -100~+50nm Angular Offset 8 ±0.2 FC/APC Item Test condition Loss Mechanical feature Interchangeability Free interconnection Vibration 5-50Hz,1.55mm amplitude High temperature +70 for continuous 96 hours Environmental characteristics Low temperature -25 for continuous 96 hours cycle -10 -+60,5 cycles Humidity +25 -+65, 93%R.H,96 hours 5.1 Transport FC/APC -40...+80 C Relative humidity 5-100%. FC/APC -40...+70 C Relative humidity 5-95% Time 12 month FC/APC -25...+70 C Relative humidity 10-90%

FC/UPC Patchcord FC/UPC patchcord are mainly used in telecom network, especially in CATV, Local Area Networks (LAN) or FTTX networks. The requirement of insertion loss and return loss requirement was maintained at a high level to ensure a future proof network. FC/UPC patchcord series is produced in a cost-effective and rigid production process under controlled processes to ensure long-term stability and reliability. 1 TOLERANCES OF LENGTH (mm) L 50000 + 50 / - 50 2 Standard lengths for patch cords and pigtails are 1, 2, 3, 5,10 meters and customized. 3 The diameters(φd) of the cable are0.9/2.0/3.0mm. Color scheme Connector House Boot FC/UPC silvery black Material House Spring Ferrule Phosphor bronze Stainless steel Phosphor bronze and Zirconia 1 The materials of connector are all in accordance with RoHS-directive. 2 Connector and hood Plastic, nonflammable (UL94-V-0) 3 The dimension meet IEC 60874-14 The preferred cable color is yellow, other colors can be customized. 0.9/2.0/3.0mm, tight secondary coating and jacket are made of flame retardant material. Insertion Loss measurement test against reference connectors are intended to be used when quality conformance is required. Random mating attenuation test shall be used during qualification to ensure that the optical performance requirements are met. Insertion Loss(Reference plug) Insertion Loss (Random mated) Return Loss FC/UPC 0.30dB 0.50dB 50dB

Connectors are manufactured in a controlled process to ensure ferrule end face geometry after termination and polishing. All geometrical parameters are defined in IEC 61753-3-1 to meet specific requirement for fiber-to-fiber interconnection and ensure a stable optical performance. Radius of Curvature Apex Offset Fiber Height(Spherical) Angular Offset FC/UPC 10~25mm 50μm -50~+50nm N/A FC/UPC Item Test condition Loss Mechanical feature Environmental characteristics Interchangeability Free interconnection Vibration 5-50Hz,1.55mm amplitude High temperature +70 for continuous 96 hours Low temperature -25 for continuous 96 hours cycle -10 -+60,5 cycles Humidity +25 -+65, 93%R.H, 96 hours 5.1 Transport FC/UPC -40...+80 C Relative humidity 5-100%. 5.2 Storage FC/UPC -40...+70 C Relative humidity 5-95% Time 12 month 5.3 Operation FC/UPC -25...+70 C Relative humidity 10-90%

LC-SC SM Duplex Patchcord LC-SC Duplex patchcord are mainly used in telecom network, especially in CATV, Local Area Networks (LAN) or FTTX networks. The requirement of insertion loss and return loss requirement was maintained at a high level to ensure a future proof network. LC-SC Duplex patchcord series is produced in a cost-effective and rigid production process under controlled processes to ensure long-term stability and reliability. A K H-S C B Connector 1(LC) Connector 2 (SC) 1 TOLERANCES OF LENGTH (mm) L 15000 + 150 / -1 50 2 Standard lengths for patch cords and Patch cords are 1, 2, 3, 5 and 10 meters. 3 PLUG DIMENSION (mm) CB REF MIN MAX CB 51 BD 60 BE 2.0 2.2 Color scheme Connector House Boot blue White blue blue Material House Spring Ferrule Plastic Stainless steel Phosphor bronze and Zirconia 1 The materials of connector are all in accordance with RoHS-directive. 2 Connector and hood Plastic, non flammable (UL94-V-0) 3 The dimension meet IEC 61754-20(LC)or IEC 61754-4(SC)

The fiber type: single-mode fiber G652D, G657A/B, and customized. The preferred cable color is yellow other colors can be customized. 2.4 4.0mm, tight secondary coating. It s made of flame retardant material. Insertion Loss measurement test against reference connectors are intended to be used when quality conformance is required. Random mating attenuation test shall be used during qualification to ensure that the optical performance requirements are met. Insertion Loss(Reference plug) Insertion Loss (Random mated) Return Loss Insertion Loss(Reference plug) Insertion Loss (Random mated) Return Loss 0.30dB 0.50dB 20dB 0.30dB 0.50dB 50dB Connectors are manufactured in a controlled process to ensure ferrule end face geometry after termination and polishing. Ensure a stable optical performance. Radius of Curvature Apex Offset Fiber Height(Sperical) Angular Offset Radius of Curvature Apex Offset Fiber Height(Spherical) Angular Offset 10~25mm 50μm -100~+50nm N/A 7~25mm 50μm -100~+50nm N/A

and Item Test condition Loss Mechanical feature Environmental characteristics Interchangeability Free interconnection Vibration 5-50Hz,1.55mm amplitude High temperature +70 for continuous 96 hours Low temperature -25 for continuous 96 hours cycle -10 -+60,5 cycles Humidity +25 -+65, 93%R.H,96 hours 5.1 Transport. 5.2 Storage 5.3 Operation and -40...+80 C Relative humidity 5-100% and -40...+70 C Relative humidity 5-95% Time 12 month LC/PC and -25...+70 C Relative humidity 10-90%

Patch cord patchcord are mainly used in telecom network, especially in CATV, Local Area Networks (LAN) or FTTX networks. The requirement of insertion loss and return loss requirement was maintained at a high level to ensure a future proof network. patchcord series is produced in a cost-effective and rigid production process under controlled processes to ensure long-term stability and reliability. 1 TOLERANCES OF LENGTH (mm) L 10000 + 50 / - 50 2 Standard lengths for patch cords and Patch cords are 1, 2, 3, 5 and 10 meters. 3 PLUG DIMENSION (mm) REF MIN MAX CB 51 Color scheme Connector House Boot Blue White Material House Spring Ferrule Plastic Stainless steel Phosphor bronze and Zirconia 1 The materials of connector are all in accordance with ROHS-directive. 2 Connector and hood Plastic, nonflammable (UL94-V-0) 3 The dimension meet IEC 60874-14 The fiber type: single-mode fiber G652D, G655, G657A/B, and customized.

The preferred cable color is yellow other colors can be customized. 0.9/2.0/3.0mm, tight secondary coating. It is made of flame retardant material. Insertion Loss measurement test against reference connectors are intended to be used when quality conformance is required. Random mating attenuation test shall be used during qualification to ensure that the optical performance requirements are met. Insertion Loss(Reference plug) Insertion Loss (Random mated) Return Loss 0.30dB 0.50dB 50dB Connectors are manufactured in a controlled process to ensure ferrule end face, geometry after termination and polishing. All geometrical parameters are defined in IEC 61753-3-1 to meet specific requirement for fiber-tofiber interconnection and ensure a stable optical performance. Radius of Curvature 5~12mm Apex Offset 50μm Fiber Height -100~+50nm Angular Offset - LC/UP Mechanical feature Interchangeability Free interconnection Vibration 5-50Hz,1.55mm amplitude High temperature +70 for continuous 96 hours Environmental characteristics Low temperature -25 for continuous 96 hours cycle -10 -+60,5 cycles Humidiy +25 -+65, 93%R.H,96 hours

5.1 Transport -40...+80 C Relative humidity 5-100%. 5.2 Storage -40...+70 C Relative humidity 5-95% Time 12 month 5.3 Operation -25...+70 C Relative humidity 10-90%

Patchcord patchcord are mainly used in telecom network, especially in CATV. Local Area Networks (LAN) or FTTX networks. The requirement of insertion loss and return loss requirement was maintained at a high level to ensure a future proof network. patchcord series is produced in a cost-effective and rigid production process under controlled processes to ensure long-term stability and reliability. 1TOLERANCES OF LENGTH (mm) + 100 / - 50 + 200 / - 100 L > 50000 + 400 / - 100 2 Standard lengths for patch cords and pigtails are 1, 2, 3, 5,10 meters and customized. 3 The diameters(φd) of the cable are 0.9,2.0,3.0mm. 4PLUG DIMENSION (mm) REF MIN MAX BD 60 BE D+0.1 D+0.3 Color scheme Connector House Boot blue blue Material House Spring Ferrule Plastic Stainless steel Phosphor bronze and Zirconia 1 The materials of connector are all in accordance with RoHS-directive. 2 Connector and hood Plastic, nonflammable (UL94-V-0). 3 The dimension meet IEC 60874-14

The fiber type: single-mode fiber G652D, G657A/B, and customized. The preferred cable color is yellow, other colors can be customized. 0.9/2.0/3.0mm, tight secondary coating. It is made of flame retardant or LSZH material. Insertion Loss measurement test against reference connectors are intended to be used when quality conformance is required. Random mating attenuation test shall be used during qualification to ensure that the optical performance requirements are met. Insertion Loss(Reference plug) Insertion Loss (Random mated) Return Loss 0.30dB 0.50dB 50dB Connectors are manufactured in a controlled process to ensure ferrule end face geometry after termination and polishing. All geometrical parameters are defined in IEC 61753-3-1 to meet specific requirement for fiber-to-fiber interconnection and ensure a stable optical performance. Radius of Curvature Apex Offset Fiber Height Angular Offset 10~25mm 50μm -50~+50nm N/A Item Test condition Loss Mechanical feature Interchangeability Free interconnection Vibration 5-50Hz,1.55mm amplitude High temperature +70 for continuous 96 hours Environmental characteristics Low temperature -25 for continuous 96 hours cycle -10 -+60,5 cycles Humidiy +25 -+65, 93%R.H,96 hours

5.1 Transport -40...+80 C Relative humidity 5-100%. 5.2 Storage -40...+70 C Relative humidity 5-95% Time 12 month 5.3 Operation -25...+70 C Relative humidity 10-90%