10 Year LED Warranty

Signal White is standard finish

HP-4 WW-R. Finelite, Inc Whipple Road Union City, CA / Fax: 510 /

S17-LED. Finelite, Inc Whipple Road Union City, CA / Fax: 510 /

Regressed Optic. Sheetrock. Finelite, Inc Whipple Road Union City, CA (510) Fax: (510)

FINELITE 10 Year LED Warranty

HP-2 WW-R. Finelite, Inc Whipple Road Union City, CA / Fax: 510 /

Finelite, Inc Whipple Road Union City, CA / Fax: 510 /

FINELITE 10 Year LED Warranty

Low Profile T-Bar Power Supply Box shown. ELECTRICAL BOX OPTIONS Mounting options for new and retrofit installations. See page 2 for more information.

Perimeter Lighting. High Performance. Perimeter Slot (HP-WS) & Wall Grazer (HP-WG)

FINELITE. 10 Year LED Warranty. High Performance Recessed (HPR LED) 2x2, Standard Output (S), Boosted Standard Output (B)

PERIMETER - RECESSED. Flush BBPRLED OPRI ( 1) 14 PRODUCT ID LINEAR OR CORNER QTY TOTAL LENGTH. 3D VIEW - Inside Corner Pattern

PERIMETER - RECESSED. Regressed 3" BMPRLED OPRI ( 1) 14 PRODUCT ID LINEAR OR CORNER QTY TOTAL LENGTH. 3D VIEW - Inside Corner Pattern

light J ANATOMY or CLEAN CANTILEVER Sleek square aluminum tube cantilever arms allow integral powerfeed to an electrical junction box.

SURFACE MOUNT. Project. Type. Notes

Project. Type. Notes. C custom UNV universal BI bi-level dimming +NL(#) night light circuit (7) O other (6) +GTD(#) generator transfer device (7)

IC 4 5 YEAR RECESSED MOUNT. Project. Type. Notes 1 9/16 PERFORMANCE PER LINEAR FOOT AT 4000K CONTROL SENSORS

RECESSED ASYMMETRIC MOUNT. Project. Type. Notes TECHZONE TM AND LOGIX TM COMPATIBLE

Luminaire PROFILE-SPOKE 15 UP 85 DN LED (PS1-D) Type. Notes. Performance Summary D OPTIONS 3S A 28 W B 34 W C 44 W D 57 W

Tove. High Performance Linear System Perimeter

RECESSED - WITH StepLens OPTION. TECHZONE TM AND LOGIX TM COMPATIBLE for more info see page 4 See page 2 for DLC Approved Options

Luminaire PROFILE-SPOKE Ind. Up Dn Control (PS3-B) Type. Project. Notes. Performance Summary OPTIONS 4S D 76 W 3S D 57 W

L10 - L40: 6-5/8 L50 - L60: 7-3/ K K K K. EM/10W 10-watt emergency battery [4] TrimLock.

SURFACE ASYMMETRIC MOUNT. Project. Type. Notes

Notes: 4" 102mm. (1) Compatible with Redwood systems

4DS 4.5 Downlight Square

M36 LED Recessed Quickship

WALL MOUNT - DIRECT/INDIRECT

SURFACE FLUSH FLUSH 5 1 / / /4 2 1 /16

DESCRIPTION PROJECT: Via 2 features our Asymmetrical Lens Optic for smooth, comfortable

Project. Type. Notes. (3) D dimming (0-10V) 5% standard

LUMINAIRE ID DIRECT OPTICS INDIRECT OPTICS LIGHT SOURCE CRI DIRECT LUMEN PACKAGES. LED - high performance LED

4DR 4.5 Downlight Round

FINA F48 48 Direct and Uplight Architectural Round

Luminaire PROFILE-SPOKE 40UP 60 DN LED (PS1-A) Type. Notes. Performance Summary OPTIONS CONTROLS

LiFT LF12 1x2 Architectural Recessed

FULL BLEED APPLICATION SHOT RENDERING

P15 - P44: 5-3/4 P62: 6-1/2. SCA Sloped ceiling TrimLock K K K K TW Tunable white (80 CRI, 2700K 5000K) 65 Open

L10 - L40: 5-3/4 L50 - L60: 6-1/ K K K F OF 1/2. 65 Open. CG Champagne gold anodize for shower. 45 Open

Tove. High Performance Linear System Recessed

SURFACE MOUNT. See page 3 for DLC Approved options

L10 - L40: 6-5/8 L50 - L60: 7-3/ K K K F. 65 Open. SPC Clear specular anodize for shower

PENDANT MOUNT - DIRECT

PENDANT MOUNT - DIRECT. Project. Type. Notes

NOVENTA NV3.5 SUSPENDED, WALL, SURFACE, RECESSED. STANDARD SIZES 3.5" Aperture corner profile Configurable in individual straight run sections

PENDANT MOUNT. Project. Type. Notes

PENDANT MOUNT - DIRECT. Project. Type. Notes

RECESSED T-BAR & DRYWALL. Project. Type. Notes. 0.5 StepLens. StepLens

SURFACE MOUNTED. Project. Type. Notes. culus Listed Type I.C.

VIA 4 LED RECESSED W W W. L U M E N W E R X. C O M

6DS 6 Downlight Square

(5) For 347V only (6) Specify system (7) Please consult factory; see page 2

RECESSED MOUNT. Outputs between listed min and max are available. Consult factory for outputs outside of the listed range.

VIA 2 LED PENDANT DIRECT/INDIRECT W W W. L U M E N W E R X. C O M

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. LED - high performance LED

PROFILE 50 Up 50 Dn PF1-E. Luminaire PROFILE - 50 UP 50 DN LaED (PF1-E) Type. Project. Product. Notes. Performance Summary

Project Name. 23-3/4 (603.3mm)

PENDANT ASYMMETRIC MOUNT

light FULL BLEED APPLICATION SHOT RENDERING

WALL MOUNT DIRECT/INDIRECT. Project. Type. Notes

6-1/4. Adjusts from 1/2 min. to 5/8 max. Pan size: 8 1/2 x 12 9/16 SERIES TRIM TYPE ADJUSTMENT LUMENS [1] CRI CCT DISTRIBUTION.

Project Name. 24 (609.6mm) 24 (609.6mm)

PENDANT MOUNT - DIRECT/INDIRECT

CONVERJ CJ22 2x2 Architectural Recessed

CONVERJ CJ14 1x4 Architectural Recessed

Project Name. 24 (609.6mm)

RECESSED T-Bar & Drywall. Project. Type. Notes 23 15/16" 23 7/8" SIDE VIEW. culus Listed Type I.C.

4DS 4.5 Downlight Square

Qty: L6JR2 Continuous Flange (Flangeless Endcaps) 1B25 1,2 430lm/6.3W per foot. 1B30 1,2 480lm/7.2W per foot. 1B lm/8.5w per foot K

Project. Type. Notes PRODUCT ID NOM.LUMENS/FT CRI COLOUR TEMP. SHIELDING LENGTH/FT FINISH VOLTAGE

WALL MOUNT DIRECT. Project. Type. Notes

NOTCH 2 Symmetric - NT1-B. Luminaire NOTCH 2 - Area 100 Dn Symmetric (NT1-B) Type. Project. Product. Notes. Performance Summary

CLARA CLA SUSPENDED, WALL, SURFACE

STUD TM 3 Linear LED luminaire- T-bar Mount

Luminaire LOOP 1x4 (LR1-14) Type. Project. Product. Notes. Performance Summary LR OPTIONS K K K

PROFILE 100 Dn PF1-B. Luminaire PROFILE DN LED (PF1-B) Type. Project. Product. Notes. Performance Summary

Tove. High Performance Linear System T-Grid Recessed

6DR 6 Downlight Round

Notes: 4 3/4" 121mm. (1) Compatible with Redwood systems. See integrated controls guide for further details

VIA 4 LED PENDANT DIRECT/INDIRECT W W W. L U M E N W E R X. C O M

SURFACE MOUNT. (2) D dimming (0-10V) 5% standard

AXLE LED WALL ASYMMETRIC INDIRECT W W W. L U M E N W E R X. C O M

DESCRIPTION PROJECT: Vega is an efficient architectural LED troffer with a distinctive luminous shielding that features a median textured

LOOP 65 Up 35 Dn LS1-A. Luminaire LOOP - 65 UP 35 DN LED (LS1-A) Type. Project. Product. Notes. Performance Summary OPTIONS

Tove. High Performance Linear System Suspension

pr1me FX LINEAR AMBIENT LIGHTING

Evolution Outline RECESSED LINEAR PERIMETER OUTLINE SLOT SYSTEM

4DR 4.5 Downlight Round

AXLE LED PENDANT ASYMMETRIC W W W. L U M E N W E R X. C O M

Notes: 4 3/4" 121mm. (1) Compatible with Redwood systems

EDGE EV3WET 3 Recessed Linear WET

VIA 2 PLUS RECESSED W W W. L U M E N W E R X. C O M

CONVERJ CJ24 2x4 Architectural Recessed

LAD6 6 LED Architectural Downlight

PENDANT ASYMMETRIC MOUNT - DIRECT. Project. Type. Notes

6DR 6 Downlight Round

CAVA CURVE LED PENDANT DIRECT/INDIRECT W W W. L U M E N W E R X. C O M

Project Name. 23-5/8 (600.2mm)

FINA F48B 48 Direct and Uplight Architectural Round

Transcription:

10 Industry Best Year LED Warranty Date Project FULLY ILLUMINATED CORNERS AVAILABLE Type Comments W x D Flat Endcap Scan QR Code to view video DESCRIPTION The High Performance is a luminaire that creates a wash of light for both ambient and vertical illumination at the transition between the wall and the ceiling plane. Available in 2', 3', 4', & 8' section lengths with telescoping options that can be combined to make longer runs and 2",, and regressed optical options. ORDERING GUIDE Sample Number: HP-WS - 4W - 4D - 8' - V - 8TW - 120V - SC - TR - SW - FE-L - TXL-R - C1 HP-WS Finelite HP-WS Optic Width (4W - Width, 6W - Width) Regressed Optic Depth (2D - 2" Depth, 4D - Depth, 6D - Depth) Length/Pre-qualified Controls by Others (2', 3', 4', 8' multiples standard) Light Output (B - Boosted Standard, V - Very High) LED CRI/CCT (8TW - 80 CRI min, Tunable White; 9TW - 90 CRI min, Tunable White. See below for Tunable White controls options) Voltage (120V, 277V) Circuiting (SC - Single Circuit) 1 Mounting (TR - Threaded Rod 2 (standard), WB - Bracket 3 ) Reflector (SW - Signal White) End Condition Left (FE-L - Flat (standard), PE-L - Pocket Slot, TXL-L - ) 4 End Condition Right (FE-R - Flat (standard), PE-R - Pocket Slot, TXL-R - ) 4 Ceiling Type (C1-1", C2-9/1, C3 - screw slot, SF - Spackle Flange) 1 Contact factory for switching options. 2 Pre- or post-ceiling. Fine TUNE TUNABLE WHITE SYSTEM 3 Pre-ceiling only. 4 The end condition on each side can be specified with different hardware options to accommodate different installation features. See page 4 for more information. TUNABLE WHITE CONTROLS OPTIONS: SELECT ONE FineTune controller with FineTune DMX Driver Controls by others with pre-qualified DMX driver Controls by others with pre-qualified DALI driver Controls by others with pre-qualified PoE setup Controls by Lutron with pre-qualified Lutron driver OR Page 1

LUMINAIRE FEATURES Bracket (WB) Mounting Available A Optic Width (, ) 1/-20 Threaded Rod (by others) Regressed Optic Depth (2",, ) 1/-20 Threaded Rod (by others) Inside 90 Corner Joints B Outside 90 DIMENSIONS & LIGHT ENGINE Distribution is attained with mid-power LEDs distributed evenly and paired with a precise regressed diffuser. POST-CEILING THREADED-ROD (TR) MOUNTING INSTALLATION Allows a luminaire to be installed after ceiling framing is complete. FULLY ILLUMINATED 90º CORNERS Fully illuminated 90º corners with telescoping standard. Refer to page 4 for telescoping lengths on inside and outside corners. Optional: TXL-L or TXL-R STRAIGHT RUNS WITH OPTIONAL TELESCOPING Optional telescoping section adds up to 12 inches for a straight run. Telescope section mounts securely to wall. TUNABLE WHITE FEATURES 6500K 100% 2700K 1% Outstanding Interface MULTIPLE CONTROL ARCHITECTURES Finelite s FineTune DMX, qualified DMX, DALI (open and proprietary), or PoE (Power over Ethernet). TUNABLE WHITE Any CCT between 2700K and 6500K with excellent CRI and R9 values; dimming from 100% to 1%. FINETUNE SYSTEM Award-winning control system, which includes intuitive wall mounted controller, power control center, driver, and mobile app to easily tailor lighting to match user preference. Page 2

THREADED-ROD (TR) MOUNTING LOCATION B Mounting Hole For 1/-20 Threaded Rod (by others) MOUNTING HOLE LOCATION TABLE LUMINAIRE LENGTH A (in) B (in) 2' 18 3 3' 30 3 A Spackle Flange 4' 36 6 8' 84 6 THREADED-ROD (TR) MOUNTING CROSS SECTIONS 4-½" 4-½" 4-½" 2" 5" 7" 9" W x 2"D W x D W x D 6-½" 6-½" 6-½" 5" 2" 7" 9" W x 2"D W x D W x D CEILING TYPES THREADED-ROD (TR) MOUNTING WALL BRACKET (WB) MOUNTING (SF) Bracket Bracket (C1, C2, C3) (SF) (C1, C2, C3) Page 3

RUN LENGTHS 2' 3' 4' 2' Section (optional) adds a minimum of 2" and a maximum of. Only one end can be extended. 3' Section (optional) adds a minimum of 1" and a maximum of. Only one end can be extended. 4' Sections (optional) adds a minimum of 1" and a maximum of. Both ends can be extended. Endcaps Information The Flat Endcap adds 1/8" per endcap to the section length. The Pocket Slot Endcap adds 1-1/ for Spackle Flange and 1" for per endcap to the section length. The Endcap adds: A minimum of 2" to a 2' section A minimum of 1" to a 3' section A minimum of 1" to 4' and 8' sections 8' 8' Sections (optional) adds a minimum of 1" and a maximum of. Both ends can be extended. Standard 2', 3', 4', and 8' section can be combined to make longer runs. 90º INSIDE AND OUTSIDE FULLY ILLUMINATED CORNER MEASURING DETAILS Inside Corner X" Outside Corner Y" X" Corner Joint Remaining Length Y" Corner Joint Measurement From End of to Inside Corner Outside Corner Width Configuration X" Min. X" Max. Y" Min. Y" Max. 4W 8" 1 1" 8" 6W 10" 1 1" 7" Notes Inside and outside corners ship standard with telescoping. is optional for straight runs. Page 4

FEED OPTIONS TELESCOPING (TXL-L or TXL-R) TAPERED OPTIC STANDARD WITH 90º INSIDE CORNERS 1/-20 Threaded Rod (by others) Top: Feed Plate (standard) Back: Feed (optional) End: Endcap Feed (optional) Refer to installation instructions for feed hole measurements. ENDCAP OPTIONS STANDARD FLAT (FE-L or FE-R) Perimeter Slot Flat end condition for when luminaire terminates at a vertical surface such as a wall. Endcap Adds 1/8" per endcap to the section length. Spackle Flange version shown, available. 1/8" POCKET SLOT (PE-L or PE-R) Ceiling Ceiling Perimeter Slot Adds 1-1/ for Spackle Flange and 1" for per endcap to the section length. version shown, Spackle Flange available. Pocket slot end condition for when slot terminates before meeting additional vertical wall surface. Drywall 1-1/ Spackle Flange 1" Page 5

PHOTOMETRY 4' W x 2"D Very High Output - 120V Efficacy: 76 lumens per watt Total Output: 3097 lumens (774 lumens/foot) 40.7 watts (10.2 watts/foot) CCT: 3500K Source Report: ITL 86712 (Family Correlation) 334 668 1002 1336 CANDELA DISTRIBUTION 0.0 45 90 135 180 Flux 0 1235 1235 1235 1235 1235 5 1280 1264 1229 1198 1168 116 15 1333 1280 1172 1002 903 321 25 1323 1241 1060 746 586 460 35 1258 1150 909 489 297 519 45 1144 1020 735 248 60 502 55 967 859 555 49 2 436 65 741 654 375 3 0 344 75 514 437 204 2 0 233 85 295 232 52 1 0 121 90 188 132 0 0 0 Total Light Output, 3500K, 80 CRI (Lumens) - 4' W x 2"D 1594 3097 Light Output, 3500K, 80 CRI (Lumens Per Foot) W x 2"D 398 774 Power, 3500K, 80 CRI (Watts Per Foot) W x 2"D 5.1 10.2 Efficacy, 3500K, 80 CRI (Lumens Per Watt) W x 2"D 79 76 B - Boosted Standard Output, V - Very High Output * Family Correlation based on 4' luminaire 3500K 80 CRI Very High Output (V) test - 120V. ** Correlation based on ITL report: 86712 Notes Refer to LM-79 reports for other configurations. Lumen Adjustment Factors - 80 CRI 2700K 0.968 3000K 0.985 3500K 1.000 4000K 1.032 6500K 1.032 Lumen Adjustment Factors - 90 CRI 2700K 0.731 3000K 0.746 3500K 0.760 4000K 0.789 6500K 0.789 Apply a lumen adjustment factor to calculate lumens for the desired CCT and CRI. SAMPLE LUMEN ADJUSTMENT CALCULATION Boosted Standard Output (B), 4000K, 90 CRI Lumen Adjustment Factor = 0.789 Total Light Output = 1594 lm x 0.789 = 1258 lm Total Light Output per Foot = 398 lm/ft x 0.789 = 314 lm/ft Efficacy = watts/foot = 5.1 W/ft 314 lm ft 5.1 W ft = 62 lm/w Page 6

CONSTRUCTION: Precision cut 6061-T6 extruded aluminum visible flange. Internal joiner system, plugtogether wiring standard. Steel sheet metal galvanized and power coated body. ENDCAPS: The luminaire can terminate in three different end conditions to accommodate project needs. Endcaps are made of 20-guage die-formed powder-coated steel. Flat (standard) Endcap adds 1/8", Pocket Slot Endcap adds 1-1/, and for Endcap refer to telescoping section below. END CONDITIONS: FLAT (standard) (FE-L or FE-R): Is used when the luminaire terminates at a wall. Adds 1/8" per endcap to overall length of the luminaire. POCKET SLOT (PE-L or PE-R): Includes the necessary hardware to accommodate ceiling materials when the luminaire doesn t terminate at a wall. Adds 1-1/ for Spackle Flange and 1" for per endcap to overall length of the luminaire. TELESCOPING (TXL-L or TXL-R): Provides up to of additional illuminated section to accommodate variances in the built-in wall slot. available on both ends of 4' and 8' luminaire sections. Adds a minimum of 1" per end to overall section length. only available at one end of 2' and 3' luminaire sections. Adds a minimum of 2" to overall length of 2' sections and a minimum of 1" to overall length of 3' sections. is standard with corners. section must end at wall and be secured with bracket (provided). 90º CORNER: Illuminated 90 inside and outside corners. Standard with telescoping sections. Tapered optics is standard with inside corners. REFLECTORS: Finelite Signal White powder coat finish standard. DIFFUSER: Frosted diffusers are 1/1. All diffusers are UV-stabilized and impact resistant virgin acrylic. LIGHT OUTPUT: Two lumen packages available, Boosted Standard (B) and Very High (V). A separate chart summarizes lumen distribution and wattage. Light engines are replaceable. LUMEN MAINTENANCE: 90% of initial light output (L90) at 100,000+ hours; 70% of initial light output (L70) at 200,000+ hours. TUNABLE WHITE DRIVER: Replaceable LED driver. Driver is accessible from below the ceiling. 120/277V. Power Factor: 0.90. Total Harmonic Distortion (THD): < 20%. Dimming Range: 100-1%. Expected driver lifetime: 100,000 hours. ELECTRICAL: SPECIFICATIONS Emergency Option DMX: Battery backup only Emergency Option DALI: Battery backup, emergency-to-generator/ Inverter wiring Emergency Option LUTRON: Battery backup, emergency-to-generator/ inverter wiring Emergency Option PoE: Contact factory. Battery Backup: Factory-choice low-profile backup battery available. 8' minimum luminaire length for low profile battery pack. Backup batteries deliver 1000 lumens. Half of a 4' section will be illuminated in emergency mode. Optional fusing is available. Optional fusing is available. Backup battery will operate 6500K in emergency. MOUNTING: The standard mounting (Threaded Rod - TR) option eliminates the need to install luminaires prior to the slot being framed. mounts on threaded rods. Gasket runs length of luminaire ensuring a clean finish at the wall. Optional mounting includes a wall bracket that is attached to the wall. s are then snapped onto the bracket. installation that uses the mounting bracket must be performed before the perimeter slot framing is built. DMX INTERCONNECTION CABLES: s are prewired with plug-and-play interconnection cables to support easy plug-together joining of luminaire runs. FINISH: Finelite Signal White powder coat finish standard. Optional Adder: 185 RAL colors. Custom color applies to the visible flange. FEED: Standard with one 18-gauge single-circuit feed. 14-gauge feed used when luminaire current exceeds 5 amps. Optional 6' flex conduit whips available. DMX feeds cannot be cut or spliced. DMX feeds should be ordered based on fixed lengths. Dual knockouts (for dual flex conduit) are available at the top and rear feed locations. Endcaps have a single knockout and support a single flex conduit only. LENGTHS / PRE-QUALIFIED CONTROLS BY OTHERS: 4', 8', and 12' sections can be combined to make longers runs. Optional telescoping sections for end runs. Contact factory for corner details and availability. sections are available on either or both ends of the luminaire. LABELS: and electrical components are ETL-listed conforming to UL 916, 1598, 8750, 924 in the U.S.A. and CAN/CSA C22.2 No. 205, 250, and 141 in Canada. In accordance with NEC Code 410.73 (G), this luminaire contains an internal driver disconnect. IC-Rated. Damp Location. Finelite products use electronic components that are RoHS compliant, and the mechanical components of the luminaire have been verified to not knowingly contain any restricted substances listed per RoHS Directive 2002/95/EC. WEIGHT: 5.6 lb/ft. WARRANTY: 10-year performance-based warranty on all standard components. Qualified drivers by others and optional accessories such as emergency battery packs are covered by their individual manufacturer warranties. TUNABLE WHITE PRE-QUALIFIED DRIVERS BY OTHERS DMX DALI POE set up LUTRON EldoLED EldoLED, Crestron Contact Factory LUTRON NOTE: For a complete list of system option/limitations please click here. Page 7