Installation Instructions Electronic pressure sensor PX PXx PXx PX PX PX9x PX9x 7057/06 0/0
Contents Safety instructions... Function and features... Installation...5 Electrical connection...5 5 Scale drawing...6 6 Technical data...8 Safety instructions Please read the product description prior to installing the unit. Please check that the product is suitable for your application without any restrictions. If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property may occur. Please check in all applications that the product materials (see Technical data) are compatible with the media to be measured. For gaseous media the application is limited to max. 6 PSI. High-pressure units (5000 PSI) are supplied with a pressure relief mechanism and an integrated damping device to comply with the regulations for UL approval and to avoid any risk of injury in case of bursting when bursting pressure is exceeded. Any manipulation of the damping device is not permissible. When the damping device is removed, there is no damping function any more. ATTENTION: risk of injury! For units with culus approval this approval becomes invalid when the damping device is removed.
For units with culus approval and the scope of validity culus: The device shall be supplied from an isolating transformer having a secondary Listed fuse rated as noted in the following table. Overcurrent protection Control-circuit wire size Maximum protective device rating AWG (mm ) Ampere 6 (0.) (0.0) (0.) 0 (0.5) 5 8 (0.8) 7 6 (.) 0 The Sensor shall be connected only by using any R/C (CYJV) cord, having suitable ratings.
Function and features The pressure sensor detects the system pressure and converts it into an analog output signal. 0 to 0 V (PX9xxx) 0 to 0 V (PX99) to 0 ma (PXxxx) 0 to ma (PX9) Applications (type of pressure: relative pressure) Order no. Measuring range Permissible overload pressure Bursting pressure PSI PSI PSI PX0 PX90 0 to 5000 600 700 PX PX9 0 to 00 5800 0 PX PX9 0 to 000 50 900 PX 0 to 500 75 5075 PX PX9 0 to 00 087 75 PX 0 to 50 087 75 PX9 0 to 00 087 75 PX6 PX96 0 to 90 75 PX7 0 to 0 5 50 PX7 PX97 0 to 5 5 50 PX8 0 to 5 5 50 PX9 PX99 -.5 to 0 (vacuum) 5 50 PX -.5 to 75.5 50 900 inho inho inho PX8 PX98 0 to 00 05 0
Avoid static and dynamic overpressure exceeding the given over-load pressure. Even if the bursting pressure is exceeded only for a short time the unit can be destroyed (danger of injuries)! Installation Before mounting and removing the sensor, make sure that no pressure is applied to the system. Mount the pressure sensor on a suitable process connection (see type label Port Size ). Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Voltage supply to EN5078, SELV, PELV. Disconnect power before connecting the unit as follows: Voltage output (PX9xxx) n.c. L+ L- Current output (PXxxx) L+ L- n.c. n.c. For information about available sockets/connectors see: www.ifm.com Products Accessories 5
5 Scale drawing PX0 PX90 PX PX PX PX9 PX9 M x M x 79,5 79,5 M5 / -8 NPT M5 / -8 NPT : Pressure relief mechanism No mechanical force must be exerted on the pressure relief mechanism. dimensions are in millimeters (5. mm = inch) process connection / NPT, tigtening torque 5 Nm 6
PX PX PX PX6 PX7 PX8 PX9 M x PX9 PX96 PX97 PX98 PX99 PX9 PX7 PX8 M x 79,5 79,5 M5 / -8 NPT M5 / -8 NPT : Ventilation : Ventilation dimensions are in millimeters (5. mm = inch) process connection / NPT, tigtening torque 5 Nm 7
6 Technical data PXxxx Operating voltage [V]...9.6 to DC ) Analog output... to 0 ma Load [Ω]...max. (U B - 9,6) x 50; 70 at U B = V DC Step response time analog output [ms]... PX9xxx Operating voltage [V]...6 to DC ) Current consumption [ma]...< 8 Analog output...0 to 0 V DC Load [Ω]...min. 000 Step response time analog output [ms]... Characteristics deviation (in % of full range) PX, PX9... < ± 0.5 (BFSL) / < ± 0.75 (FR) PX0, PX, PX, PX, PX9... < ± 0.5 (BFSL) / < ± 0.75 (FR) PX, PX, PX9... < ± 0.5 (BFSL) / < ± 0.75 (FR) PX6, PX96... < ± 0.5 (BFSL) / < ± 0.75 (FR) PX7, PX7, PX8, PX97... < ± 0.5 (BFSL) / < ± 0.5 (FR) PX8, PX98... < ± 0.5 (BFSL) / < ± 0.75 (FR) PX9, PX99... < ± 0.5 (BFSL) / < ± 0.5 (FR) PX90... < ± 0.5 (BFSL) / < ± 0.75 (FR) PX9... < ± 0.5 (BFSL) / < ± 0.75 (FR) Repeatability (in % of full range) PX, PX9... < 0.5 PX0, PX, PX, PX9... < 0.5 PX, PX, PX9... < 0.5 PX6, PX96... < 0.5 PX, PX7, PX97... < 0. PX8, PX98... < 0.5 PX9, PX99... < 0. PX7, PX8... < 0.5 PX90... < 0.5 PX9... < 0. ) to EN5078, SELV, PELV BFSL = Best Fit Straight Line / FR = full range 8
Temperature coefficients (TEMPCO) in the compensated temperature range 0 to 80 C (in% of full range/0 C); greatest TEMPCO of the zero point / of full range PX, PX9... 0. / 0. PX0, PX, PX90... 0. / 0. PX, PX9... 0. / 0. PX... 0. / 0. PX, PX, PX9... 0. / 0. PX6, PX96... 0. / 0. PX7, PX97... 0.5 / 0. PX8, PX98... 0. / 0. PX9, PX99... 0.5 / 0. PX7... 0. / 0. PX8... 0./ 0.5 PX9... 0.5 / 0. Housing material...stainless steel (6S); FPM (Viton); PA; EPDM/X (Santoprene) Materials (wetted parts)...stainless steel (S); ceramics; FPM (Viton) Operating temperature [ C]... -5 to +80 Medium temperature [ C]... -5 to +90 Storage temperature [ C]... -0 to +00 Protection...IP 68 / IP 69K ) Protection... IP 67 ) Protection... IP 65 ) Protection class...iii Insulation resistance [MΩ]...> 00 (500 V DC) Shock resistance [g]... 50 (DIN / IEC 68--7, ms) Vibration resistance [g]...0 (DIN / IEC 68--6, 0-000 Hz) EMC EN 6000-- ESD:... kv / 8 KV AD EN 6000-- HF radiated:... V/m EN 6000-- Burst:... KV EN 6000--6 HF conducted:... 0 V Radiation of interference:.according to the road vehicle guideline 00/0/EC / CISPR5 Noise immunity:... according to the road vehicle guideline 00/0/EC / ISO 5- HF conducted:... 00 V/m Pulse resistance:...according to ISO767- / severity level ) for PX, PX0, PX, PX, PX90, PX9, PX9, ) for PX7, PX8 ) for PX, PX, PX6, PX7, PX8, PX9, PX PX9, PX96, PX97, PX98, PX99, PX9 More information at www.ifm.com 9