INDUSTRIAL PUMP 8000 SERIES

Similar documents
INDUSTRIAL PUMP 8000 SERIES

For a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.

Installation Manual for the SHURflo LCB - G Pump Controller

FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions

Installation, Operation, Repair and Parts Manual

INSTALLATION AND OPERATION MANUAL MOUNTING ELECTRICAL

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Perimeter Pro B OPERATING MANUAL

PowerFLO 5800/5900 Series

ProFlo FatBoy

RV PRODUCT DATA SHEET

ARAG Modular Manual Valve Operating Instructions and Parts Manual

ARAG Modular Electric Valve Operating Instructions and Parts Manual

Operator s Safety and Service Manual

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Rev: Flow Max 115V AC Fluid Pump

SHURFLO AQUA KING II STANDARD 3.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

Maintenance Instructions for All Models

WORKHORSE. Assembly / Operation Instructions / Parts 15 & 25 GALLON SPOT SPRAYER

OBE, OBEXU, ON BOARD Battery Chargers

OBAE, OBAEXU, ON BOARD Battery Chargers

QPET, QPETXU Battery Chargers

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

100 Gallon Skid Sprayer

WORKHORSE. Assembly / Operation Instructions / Parts 15 GALLON TRAILER SPRAYER

100 Gallon 4- Wheel Sprayer

100 Gallon Skid Sprayer

Low Pressure Diaphragm Pumps

SOLAR ELECTRIC SUBMERSIBLE PUMP D.C. POWERED OWNERS MANUAL

QSSE, QSSEX INDUSTRIAL Battery Chargers

WORKHORSE. Assembly / Operation Instructions / Parts 25 GALLON TRAILER SPRAYER

SOLAR ELECTRIC SUBMERSIBLE PUMP D.C. POWERED OWNERS MANUAL

50 Gallon Skid Sprayer

Installation, Operation, Repair and Parts Manual

Cleanload Chemical Eductor

PERISTALTIC DOSING PUMP OPERATING MANUAL. MODEL: FS SERIES Fixed Speed Peristaltic Pump

Model &

WORKHORSE. Assembly / Operation Instructions / Parts

WORKHORSE. Assembly / Operation Instructions / Parts

Features and Benefits Wide Bottom: Translucent Bottle: 2 1/2 Gallon Bottle: Removable Bottle: Large cap: 15 Feet of Coiled Hose:

WORKHORSE. Assembly / Operation Instructions / Parts

The table below shows brix pump ratios currently available. The brix pump is shipped with the 3-way sanitizing valve.

Assembly / Operation Instructions / Parts

PRE-PLUMBED SEWAGE SYSTEM

Flojet Rewrites the Book on Small Pump Control

150 Gallon 3- Point Hitch Sprayer

PARTS AND INSTALLATION MANUAL

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

WORKHORSE. Assembly / Operation Instructions / Parts DELUXE ATV BOOMLESS SPRAYER

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

BRITE STRIPER INSTRUCTION MANUAL & PARTS LISTING

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

GARDEN HOSE UTILITY PUMP

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

StormPro BA Series Sump Pump

SUBMERSIBLE SUMP PUMPS

Operator s Safety and Service Manual

MITYFLEX PERISTALTIC PUMPS

Models 9910-DP423 and 9910-DP423GRGI

S T O P. Oil Pump. Models L 5016, L 5116 and L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

WORKHORSE PSE. Assembly / Operation Instructions / Parts

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

QUALITY MISTING PUMPS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Oil Pump Models L 5016, L 5116 & L 5132

ESE Series Cast Iron Sewage Pumps

DC to AC Power Inverters

SUBMERSIBLE SUMP PUMPS

DC to AC Power Inverters

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Installation, Operation, Repair, and Parts Manual

F PRO. 12 Volt Battery Powered Sprayer LIMITED WARRANTY. Part #AS75 Copyright 2014 by Hydro-Force Rev. 1/14

WORKHORSE PSE. Assembly / Operation Instructions / Parts

SHALLOW WELL JET PUMP

Installation, Operating and Maintenance Manual

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

Cleanload Chemical Eductor

IMPORTANT SAFETY INSTRUCTIONS

AUTO-PUMP 12V HP-VER FOR VERTICAL MOUNT ONLY MODEL #: V-HP-VER 12VDC HIGH OUTPUT AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL

High Pressure Diaphragm Pumps

Model FM1000 Series Operating Instructions. Drum Pump Flow Meter

STAR STOP SHALLOW WELL JET PUMP

Low Pressure Diaphragm Pumps

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

MRC 150/300 USER MANUAL. 1 Laird Technologies

11202 INSTALLATION INSTRUCTIONS

QUALITY MISTING PUMPS

Model GD-70D4A-XX Supplement to the GD-70D Operator s Manual

BATTERY SAVER LOW RIPPLE HO

AEROMOTIVE Part # and F-Body Fuel System Kit INSTALLATION INSTRUCTIONS

A2P Single Phase Automatic Industrial Battery Charger

Transcription:

INDUSTRIAL PUMP 8000 SERIES Installation and Operation Manual SHURflo offers various pump models for different applications. The information outlined by this manual is general, and not specific to all 8000 series pumps. Be certain the pumps' materials will be compatible with the fluid being pumped. 8000 series pumps are intended for intermittent or continuous duty when the proper operating criteria is met. Product Data Sheets outlining specific thermal limits, load, flow curves, and other technical information for a particular model are available. If unsure of the chemical compatibility with a given elastomer or the motors intended design, please call SHURflo for assistance. CAUTION: "Intermittent Duty" is defined as; operated and/or frequently started within a period of time that would cause the motor to reach its maximum thermal limits. Once the maximum thermal limit is obtained, the motor must be allowed to return to ambient temperature before resuming operation. CAUTION: DO NOT use to pump flammable liquids. Never operate the pump in an explosive environment. Arcing from the motor brushes, switch or excessive heat from an improperly cycled motor may cause an explosion. CAUTION: DO NOT assume fluid compatibility. If the fluid is improperly matched to the pumps' elastomers, a leak may occur. Pumps used to transfer hazardous or hot (max. temperature 170 F [76 C] Viton only) chemicals must be in a vented area to guard against the possibility of injury due to harmful or explosive liquid/vapors. CAUTION: DO NOT operate the pump at pressures which cause the motor to exceed the amperes rating indicated on the name plate. Various pump models are equipped with thermal breakers to interrupt operation due to excessive heat. Once the temperature of the motor is within proper limits it 911-314 Rev. P 10/02 Page: 1 of 8

will automatically reset, and the pump will start operation without warning. CAUTION: To prevent electrical shock, disconnect power before initiating any work. In the case of pump failure, the motor housing and/or the pumped fluid may carry high voltage to components normally considered safe. PRESSURE SWITCH OPERATION (If Equipped) The pressure switch reacts to outlet pressure, and interrupts power at the preset shut-off pressure indicated on the pump label. When outlet pressure drops below a predetermined limit (*typically 15-20 psi. [1-1.4 bar] less than the shut-off pressure), the switch will close and the pump operates until the shut-off (high) pressure is achieved. The shut-off pressure is set to factory calibrated standards. CAUTION: Improper adjustment of the pressure switch setting, may cause severe overload or premature failure. Refer to SHURflo Service Bulletin #1031 for the adjustment procedure. Failures due to improper adjustment of the pressure switch setting will not be covered under the limited warranty. If the plumbing is restrictive or the flow rate is very low, the pump may repressurize the outlet faster than the fluid is being released, causing rapid cycling (*ON/OFF within 2 sec.). If the pump is subjected to rapid cycling during normal operation, or for infrequent periods, damage may occur. Applications which exhibit rapid cycling should have restrictions in the outlet minimized. If not feasible consider a SHURflo Accumulator or a SHURflo "bypass" model pump. BYPASS OPERATION (If Equipped*) A bypass pump may be used in application that would normally induce frequent start/stop of the motor, and thereby create a potential for overheating. Models equipped with an internal bypass are designed to pump at high pressure while at low flow rates. Bypass models equipped with a

switch may operate for several seconds even though the discharge side has been closed off. Models equipped with a bypass only will continue to run until power is turned OFF.

MOUNTING The 8000 series pumps are self priming. Horizontal and vertical prime vary depending on the fluid viscosity and pump configuration. Refer to the pumps Product Data Sheet. The pump should be located in an area that is dry and provides adequate ventilation. If mounted within an enclosure, provisions to cool the motor may be necessary. Heat sinks which attach to the motor are available from SHURflo if increased heat dissipation is necessary. CAUTION: DO NOT locate the motor near low temperature plastics or combustible material. The surface temperature of the motor may exceed *250 F [120 C]. The pump may be mounted in any position. However, if mounting the pump vertically the pump head should be in the down position so that in the unlikely event of a leak, fluid will not enter the motor. Secure the rubber feet with # 8 hardware. DO NOT compress the feet, doing so will reduce their ability to isolate vibration/noise. PLUMBING Use flexible high pressure tubing compatible with the fluid to connect the inlet/outlet ports. Tubing should be either 3/8" or 1/2" [10 or 13 mm] I.D., and at least 18 in. [46 cm] length is suggested to minimize stress on the fitting/ports and reduce noise. Allow for the shortest possible tubing route and avoid sharp bends that may kink over time. Installation of a 50 mesh strainer is recommended to prevent foreign debris from entering the system. Failures due to foreign debris is not covered under the limited warranty. NOTE: Restrictions on the inlet may cause vacuum levels to reach the fluid vapor pressure, causing cavitation, degassing, vapor lock and a loss in performance. Inlet pressure must not exceed 30 psi [2.1 bar] maximum.

If a check valve is installed in the plumbing it must have a cracking pressure of no more than 2 psi [.14 bar]. NOTE: SHURflo does not recommend the use of metal fittings or rigid pipe to plumb the inlet/outlet ports. Standard plastic male and female threaded fittings can be acquired at commercial plumbing supply stores. SHURflo also distributes Swivel Barb Fittings, and special fittings through our dealers (Form # 07-010-0011). 3/8" Female NPT models: In some cases, the ports may require a suitable thread sealer applied sparingly. DO NOT over-tighten, max. torque 3.7 ft\lb (45 in\lb ) [5 Nm]. 1/2" Male threaded models: Are intended to be used with SHURflo Swivel Barb Fittings which seal with an internal taper when hand tightened. Standard 1/2" NPT fittings may be used when tightened to a max. torque of 3.7 ft\lb (45 in\lb) [5 Nm]. CAUTION: Sealers and Teflon tape may act as lubricant causing cracked housings or stripped threads due to over tightening. Care should be used when applying sealers, it may enter the pump inhibiting valve action, causing no prime or no shut-off. Failures due to foreign debris is not covered under warranty. Snap-Lock models: The slide fittings are open when the slide is moved out toward the switch. Fittings should be inserted flush against housing port before the slide is moved to the locked position. Fittings of Nylon or Polypropylene are available in various sizes. ELECTRICAL CAUTION: Electrical wiring should be performed by a qualified electrician, in accordance with all local electrical codes. Improper duty cycle and/or rapid start & stop conditions may cause the internal thermal breaker (if equipped) to trip, or can result in premature motor failure due to excessive heat. Refer to the pumps Product Data Sheet.

The pump should be on a dedicated (individual) circuit, controlled with a double pole switch (UL/C-UL certified) rated at or above the fuse ampere indicated by the pump motor label. Depending on distance of the power source from the pump and ampere load on the circuit, wire may need to be heavier than indicated by the chart. CAUTION: All 115 VAC and 230 VAC pump motors and systems, MUST be ground per local and state electrical codes. For the pump to meet UL/C-UL requirements the circuit MUST be protected with a slow-blow fuse (UL/C-UL certified) or equivalent circuit breaker as indicated on the motor label. Use an approved wire of the size specified or heavier. VOLTAGE MODEL FUSE (amp) WIRE LEADS WIRE SIZE 12 DC 800X-X4X-XXX 15.0 8005-X5X-XXX 2.5 24 DC 8005-X9X-XXX RED (positive +) # 14 AWG [2.5 Mm 2 ] 800X-X5X-XXX 10.0 BLACK (negative -) (or heavier) 36 DC 800X-X8X-XXX 5.0 8005-X5X-XXX 1.5 800X-X1X-XXX 1.25 BLACK (common/hot) 115 AC 800X-X2X-XXX WHITE (neutral) 800X-X3X-XXX 1.0 GREEN (ground) # 18 AWG 800X-X6X-XX C-UL / TEW 1015 800X-X0X-XXX 0.8 BROWN (common/hot) (or heavier) 230 AC 809X-X0X-XX BLUE (neutral) [1 Mm 2 ] 800X-X9X-XXX 0.5 GRN/YELL (ground) 809X-X1X-XX VDE requires a fuse (slow blow) or equivalent circuit breaker. CAUTION: Circuit protection is dependent on the individual application requirements. Failure to provide proper overload / thermal devices may result in a motor failure, which will not be covered under the limited warranty.

*The information outlined by this manual is general, and not specific to all 8000 series pumps. Contact the factory for a Product Data Sheet outlining technical information for a particular model.

TROUBLESHOOTING PUMP WILL NOT START: Fuse or breaker For correct voltage (±10%) and electrical connections Pressure switch operation and correct voltage at switch or motor wires (as equipped). Rectifier or motor for open or grounded circuit For locked drive assembly WILL NOT PRIME: (No discharge/motor runs) Out of product Strainer for debris Inlet tubing/plumbing; severe vacuum leak Inlet/Outlet tube severely restricted (kinked) Debris in pump inlet/outlet valves Proper voltage with the pump operating (±10%) Pump housing for cracks LEAKS FROM PUMP HEAD OR SWITCH: For loose screws at switch or pump head. Switch diaphragm ruptured or pinched For punctured diaphragm if fluid is present at bottom drain holes. PUMP WILL NOT SHUT-OFF: (Pressure switch equip.) Output line closed and no leaks For air trapped in outlet line or pump head For correct voltage to pump (±10%) Inlet/Outlet valves for debris or swelling For loose drive assembly or pump head screws Pressure switch operation/adjustment incorrect refer to S/B # 1031 for differential and pressure adjustment procedure NOISY / ROUGH OPERATION: Mounting feet that are compressed to tight For loose pump head or drive screws Does the mounting surface multiply noise (flexible) Is the pump plumbed with rigid pipe causing noise to transmit

SERVICE KITS Kits are readily available to repair standard 8000 series pumps. Repair kits include simple illustrated instructions allowing easy installation. To insure that the correct kit is received the model numbered and all name plate data must be included with the order. Contact a SHURflo distributor or SHURflo directly to order the necessary repair kit. KEY# DESCRIPTION 1 Complete assembled pump head 2 Pressure switch assembly 3 Check valve components 4 Upper housing 5 Bypass valve and discharge valve assembly 6 Valve plate assembly 7 Diaphragm and piston components 8 Drive assembly 9 Motor assembly (less base plate)

INDUSTRIAL PRODUCT LIMITED WARRANTY SHURflo Industrial series pumps and products are warranted to be free of defects in material and workmanship under normal use, for a period of one (1) year from the date of manufacture, or one (1) year of use, with proof of purchase. This limited warranty will not exceed two (2) years, in any event. The limited warranty will not apply to pumps/products that were improperly installed, misapplied, damaged, altered, incompatible with fluids or components not manufactured by SHURflo. All Industrial pumps/products must be flush of any chemicals before shipping. All warranty considerations are governed by SHURflo's written Return Policy. Returns are to be shipped postage prepaid to either service center; SHURflo Cypress, CA or Elkhart, IN. SHURflo shall not be liable for freight damage incurred during shipping. Package returns carefully. SHURflo's obligation under this warranty policy is limited to the repair or replacement of the pump/ product. All returns will be tested per SHURflo factory criteria. Products found not defective (under the terms of this limited warranty) are subject to charges paid by the returnee for the testing and packaging of "tested good" non-warranty returns. No credit or labor allowances will be given for pumps or products returned as defective. Warranty replacements will be shipped on a freight allowed basis. SHURflo reserves the right to choose the method of transportation. This limited warranty is in lieu of all other warranties, expressed or implied, and no other person is authorized to give any other warranty or assume obligation or liability on SHURflo's behalf. SHURflo shall not be liable for any labor, damage or other expense, nor shall SHURflo be liable for any indirect, incidental or consequential damages of any kind incurred by the reason of the use or sale of any defective product or part. This limited warranty covers industrial products distributed within the United States of America. Other world market areas should consult with the actual distributor for any deviation from this document. RETURN POLICY All Industrial pumps/products must be flushed of any chemical (ref. OSHA Section 1910.1200 (d)(e)(f)(g)(h)) and hazardous chemicals must be labeled / tagged before being shipped to SHURflo for service or warranty consideration. SHURflo reserves the right to request a Material Safety Data Sheet from the returnee for any pump/product it deems necessary. SHURflo reserves the right to "disposition as scrap" pumps/products returned which contain unknown fluids. SHURflo reserves the right to charge the returnee for any and all costs incurred for chemical testing, and proper disposal of components containing unknown fluids. SHURflo request this in order to protect the environment and personnel from the hazards of handling unknown fluids. Carriers, including U.S.P.S., airlines, UPS, ground freight, etc., require specific identification of any hazardous materials to be shipped. Failure to do so may result in a substantial fine and/or prison term. Check with your shipping company for specific instructions. R ISO Certified Facility a WICOR Company SHURflo reserves the right to update specifications, prices, or make substitutions. 911-314 Rev. P 10/02 Page: 8 of 8

SHURflo 5900 Katella Ave. Cypress, CA 90630 (800) 854-3218 (562) 795-5200 FAX (562) 795-7564 Shipping: 5900 Katella Ave., Suite B Cypress, CA 90630 SHURflo East 52748 Park Six Court Elkhart, IN 46514-5427 (800) 762-8094 (574) 262-0478 FAX (574) 264-2169 1998 Printed in USA SHURflo Ltd. Unit 5 Sterling Park Gatwick Road, Crawley West Sussex, RH10 2QT United Kingdom +44 1293 424000 FAX +44 1293 421880 911-314 Rev. P 10/02 Page: 8 of 8