Service Manual for Battery Control Center

Similar documents
AIRSTREAM - BATTERY CONTROL CENTER - Diesel

Battery Control Center - Diesel

Troubleshooting Guide

BATTERY DISCONNECT SERVICE MANUAL

DISCONTINUED. OPERATORS MANUAL for SEMI AUTOMATIC RV SYSTEM. 82 L Rev. 0 September 3, Comment [KO1]:

STP-DHI DISPENSER HOOK ISOLATION STP-DHI 120 Volt Hook STP-DHIB 240 Volt Hook

Grout Pump Automatic & Manual Troubleshooting Gas Wiring Diagram

Troubleshooting Guide

42 Series Step. Owner's Manual #842A. Equipped with a Permanent Magnet Motor. Table of Contents

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

HYDRAULIC LEVELING SYSTEMS OPERATIONS MANUAL (For systems with touch pad part number , , , , or no number at all)

TS-E TURBO STEAM ELECTRIC COUNTERTOP CONVECTION STEAMER PARTS AND SERVICE MANUAL

PARTS AND SERVICE MANUAL FOR LEVELING SYSTEMS WITH TOUCH PAD PART NUMBERS , , , , or no number at all

This chapter contains information on DC Generation, External Power, and Electrical Load Distribution.

SOLN1 25 V2 Quick Start User Guide & Operating Recommendations

TECHNICAL SERVICE BULLETIN GO-BASTA TROUBLESHOOTING A DEAD BATTERY

Kwikee # Series Step OWNER'S MANUAL ( )

BSR Magic Box Digital ignition control for 4, 6, or 8 cylinder engines

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

OPERATOR S MANUAL HWH COMPUTER-CONTROLLED 2000 SERIES LEVELING SYSTEM. FEATURING: Single Step Touch Panel Control Air Leveling

Third Generation NITE Phoenix

9/02 Kwikee Products Co. Inc. Kwikee # Electric Steps. Equipped with a Permanent Magnet Motor

SYNCHRONIZE YNCHRONIZER AUTOMATIC TIC TROUBLESHOOTING GUIDE RELAY ASSEMBLY SOLENOID (MODEL 1750) LIMIT SWITCH ENGINE CABLE CABLE TO

Kwikee Revolution Step Series


Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

oubleshooting Guide diesel - gasoline - LPG electric P.O. Box 1160 St. Joseph, MO Fax:

the systems people Owners Manual VCMS Switch Panel System Model VCMS-SP34

Kwikee IMGL Step Control Testing Procedure #82-ST0500

Fault Code 34 - Weak Battery Voltage Supply

SAFE & SECURE ACTUATOR PRODUCT MANUAL

Troubleshooting Flowcharts

ECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications

Auto-Level Troubleshooting (Old Platform) Electronic Control- Prior to 2009, Pressure Switch Control panel #s 2057, 2058, 2795, 2795B

JD TRIPLE EGRESS TRIPLE EGRESS SECTION

KWIKEE #888 ELECTRIC STEP. Owner's Manual ( )

BXD Battery Disconnect

BX88175 Installation Instructions ToadStop II Vacuum Brake System

Kwikee Platinum Series OWNER'S MANUAL

DISCONTINUED. OPERATORS MANUAL for SEMI AUTOMATIC RV SYSTEM. 82 L Rev. 0. Comment [KO1]:

24-00 ELECTRICAL POWER

Charging Liftgate Batteries Part 4 Automatic Single Pole, Dual Pole, or Seven Way Aux Pin Powered Circuit (TC-8) July 16, :00 P.M.

BMF TROUBLESHOOTING GUIDE

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Jeep JK S8/Onx6 Mount Kit

R & D SPECIALTIES ROTROL I USER'S MANUAL

Gas Spreader PLUS Remote Kit With Built in Clutch Relay and On/Off Switch

Electro Wizard TM Battery Disconnect Switch

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

JD TRIPLE EGRESS TRIPLE EGRESS SECTION

Installing the Throttle Commander Ford F250 F550 Super Duty

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

Troubleshooting Guide

Troubleshooting Flowcharts

HYDRAULIC LEVELING SYSTEMS OPERATIONS MANUAL

Idle Free Systems, Inc. Reference Guide System Component Information

INSTALLATION INSTRUCTIONS

DISCONTINUED. OPERATORS MANUAL for MANUAL RV SYSTEM REV. 1 August, Comment [KO1]:

LPT50BRD (8x11x3 Enclosure)

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

Enerdrive Lithium-Ion Battery System

Trouble Shooting. Symptom Possible Cause Solution Power switch ON but switch Light is Off. Main power to unit Off. Switch light defective.

PowerLevel s e r i e s

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

348002K/348012K Manifold Block Style Service Manual 12/2000

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Lithium Power Pack LITHIUM-ION BATTERY SYSTEM. With epro Plus Battery Monitor

ATD WATT INVERTER

Reproduction. Not for ADVANCE PRODUCT SERVICE INFORMATION INFORMATION BULLETIN NO: 36 DATE: 11/27/02 SUBJECT: POWERLINK SYSTEM

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

OPERATION MANUAL for MANUAL LEVELING SYSTEMS with square foot pads on jacks

Building Operator Certification Level I

Idle Timer Controller - A-ITC520-A Ford E Series Ford F250 - F Ford F250 - F550 (*B-ITC520-A) F650/F750

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

ITS-50R TRANSFER SWITCH OWNER S MANUAL

THROTTLE & RPM-ACTIVATED NITROUS CONTROL SYSTEM P/N 15970NOS

An ISO 9001:2008 Registered Company

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

INSTRUCTION, TRAIL CHARGER KIT P/N

APOLLO Gate Operators, Inc.

Corsa Performance Marine Solenoid & Harness Testing Procedures

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

Cruise Control Wiring

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

Quad Pump Auto System Installation/Owner s Manual

ATD WATT INVERTER

OnCommand Troubleshooting Guide Hayward Industries

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

POWER WINDOW CONTROL SYSTEM

Troubleshooting Guide

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

Application Engineering

Two Channel Remote Shutdown Device

STANDARD AND GROUND SWITCHED APPLICATIONS

INSTALLATION GUIDE Table of Contents

CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER DC TO DC BATTERY CHARGER.

eapu Reference Guide System Component Information (For serial numbers starting with 37)

Intelligent Lift Interlock System Installation Instructions

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Transcription:

Service Manual for Battery Control Center P/N 82 E0071 00 (Ref. 81 1317) June, 1999

Battery Control Box Operation Charging Circuit This function charges the coach battery from the engine alternator while driving, and charges the chassis battery from the landline converter when parked. When the engine is running, the system monitors the chassis battery voltage. When the voltage goes above 13.3 volts (DC) for approximately 30 seconds, the isolation relay is engaged, which charges the coach batteries. If the chassis/coach battery voltage decreases below 12.0 volts, the relay is opened. When the engine is shut off (no ignition signal) the isolator relay can remain closed for up to 60 minutes. When the coach is parked, the system monitors the coach battery voltage. When it increases above 13.3 volts for 30 seconds, the isolation relay engages. The system then monitors the chassis battery voltage. When the battery voltage goes above the 13.8 volts and remains there for 30 minutes, the system then opens the isolation relay. If the chassis battery falls below the coach voltage or 13.8 volts, the system will again close. This cycle will repeat until both batteries remain at or above approximately 13.8 volts. Problem Troubleshooting 1. Coach or chassis battery does not charge. The isolator relay may not be closing. Check 5 amp coach disconnect in line fuse (for location see drawing on second to last page). Verify that pin J2 4, Ignition signal has 12 volts present and that pin J2 6, Coach Disconnect signal has 12 volts present. If the signals are present, verify that the chassis battery voltage is above 13.3 volts, while operating the engine at a fast idle for at least 30 seconds. If the chassis battery voltage is below 13.3 volts, check the alternator. If above, measure the voltage across the two small isolation relay terminals. The voltage on the isolation relay terminals should be 12 +/ 4 volts when relay is closed. If the voltage across the two small isolation terminals is less than 8 volts when closed, with 12+ volts on the batteries, than replace the circuit board. If the voltage on the terminals is correct and there is not continuity across the two large isolation input lugs, than replace the isolation relay. (See picture for measurement locations) 2. Chassis battery voltage is draining down. Verify isolation relay contacts are opening. Measure the voltage across the two small isolation relay terminals, which should be 12 +/ 4 volts if relay is closed, approximately zero volts if open. If relay is closed turn coach disconnect switch to off position, and relay should open within approximately 10 seconds. Measure the voltage on the small isolation relay terminals again and check the continuity across the two large isolation input lugs. If not open, Verify that J2 6, Coach Disconnect 12 volt signal is absent, replace the relay.

Auxiliary Start: Auxiliary start is used to connect the chassis batteries to the coach batteries; in the event the chassis batteries voltage is too low to start the engine. This momentary dash switch applies 12 volts to the isolation relay coil, connecting the coach and chassis batteries together. Problem: 1. Auxiliary start will not operate. Verify 5 amp fuse for auxiliary start switch is not blown in front chassis fuse panel (See location Tag). If blown, replace fuse. Verify coach batteries are above 8 volts, please recharge. Verify that J2 6, Coach Disconnect 12 volt signal is present. Verify that J2 5, Auxiliary input 12 volt signal is present. Check for operation of isolation relay by measuring voltage on small isolation relay terminals, while applying auxiliary start switch. If voltage is proper, 12 +/ 4 volts and there is not continuity across the two large isolation input lugs, replace the isolation relay. Solar Charger: The standard solar panels are approximately 60 watts. These panels are capable of putting out up to 21 volts and 3+ amps of current. When the batteries are below 13.8 volts and there is adequate sun light, the solar controller will operate in the full charge mode, applying the full output of the panels to the batteries. When the voltage on the batteries reaches 13.8 volts and the timer times out, the Solar charger will then turn off and remain open until the battery voltage decreases. Problem: Verify coach disconnect signal J2 6 is present for solar charger to operate. Verify J2 1 solar panel input is present. Circuit Breakers: There are two 50 Amp and one 5 Amp, Type III (Manual Reset), circuit breakers mounted in the box. All three breakers connect directly to the coach battery. The two 50 amp. breakers connect to the converter and the coach fuse panel, respectively. The 5 amp. breaker is connected to the refrigerator.

50A BREAKER 50A BREAKER 5A BREAKER ISOLATION RELAY LARGE ISOLATION INPUTS SMALL ISOLATION RELAY (MEASURE VOLTAGE HERE) COACH BATTERY GENERATOR/ LAND LINE CHASSIS BATTERY J2 (6 PIN CONNECTOR) 15A FUSE J1 (5 PIN CONNECTOR) SOLAR QUICK CHARGE RELAY GROUND LUG

Plugs, Pins and Functions J1 5 Pin in line, Mate N Lock J2 6 Pin Matrix, Mate N Lock PIN FUNCTION PIN FUNCTION 1 Isolation Solenoid 1 Solar Panel Input + 2 Isolation Solenoid + 2 Charged LED 3 Ground 3 Charging LED 4 Coach Battery + 4 Ignition Signal 5 Chassis Battery + 5 Manual Override 6 Coach Disconnect