AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

Similar documents
AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

Troubleshooting Guide HYBRIDFLUSH AEF-801 SERIES

Installation and Owner s Manual HYBRIDFLUSH AEF-801 SERIES

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

MAC FAUCETS. FA400 Autoluxe Faucets

Milano AUTOMATIC FAUCET

Installation Instructions

MAC FAUCETS FA400 WALL MOUNT FAUCETS

MAC FAUCETS. FA400 Wall Mount Sensor

INSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF I toll free: I Kraus USA Inc. I REV

6-12 WIDESPREAD 6-12 W. Cleopatra Series INSTRUCTION GUIDE SAVE THIS INSTRUCTION GUIDE

Installation Instructions

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance

Installation Instructions

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

Installation Instructions

Installation Instructions

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

Installation Instructions

INSTALLATION GUIDE. Rainier Coil Pull Down Kitchen Faucet PB-K01

AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust

Installation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model:

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

Installation Instructions

Aplos Single Lever Basin Faucet

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

INSTALLATION INSTRUCTIONS

Installation For Service Only

Aquila Single Lever Vessel Faucet

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

INSTALLATION INSTRUCTIONS

ETF-600 Sensor Operated Lavatory Faucet

Installation Instructions

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

Installation Instructions

Seda Single Lever Basin Faucet

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

INSTALLATION GUIDE. Tenino Retro Pot Filler Hi-Rise Kitchen Faucet PB-K05

BC632 / BCL632 BC635 / BC635

Installation Instructions

Optima ETF-600/ETF-610

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

Ventus Single Handle Vessel Bathroom Faucet

G SERIES - E TOUCH MIXER / TAP

Installation Instructions

Single Lever Pull-Out Kitchen Faucet

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

Britt Single Handle Commercial Kitchen Faucet

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

Sheven Single Lever Vessel Faucet

Artec Pro Single Handle Commercial Kitchen Faucet

Aplos Single Lever Vessel Faucet

Ino Single Handle Basin Bathroom Faucet

Installation Instructions / Warranty

Installation Instructions

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

INSTALLATION INSTRUCTIONS

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

TWO HANDLE LAVATORY FAUCET

Single Lever Pull-Out Kitchen Faucet

INSTALLATION INSTRUCTIONS

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

FAUCET SPECIFICATIONS. Wall Mount Bathroom Faucet Model VG " 10 3/8" MODEL VG05002

4" 4" 4 1/4" 11" TOP VIE 3 1/8" Ø1/2" 2" 10 3/8" SIDE VIE VG05002 THE MEASUREMENTS IN INCHES ARE ROUNDED TO THE NEAREST 1/8"

Installation Instructions / Warranty

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser

Serial Number Purchase Date

OPERATION & MAINTENANCE MANUAL 5000E Series Faucet

SPEAKMAN. SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET

Installation Kitchen Faucet Filtration System Instructions GXK285JBL

Ramus Single Handle Lavatory Faucet

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

INSTALLATION GUIDE KPF Single Lever Kitchen Faucet With Pull-Out Sprayer

5 5 8 " Description Part # Description Part # O-ring. Tee Connector. Widespread Handle * 1.5 GPM Flow Restrictor PM-080

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

INSTALLATION INSTRUCTIONS STUDIO S

E-Mini Thermostatic Valve with Shut-Off or with Positive Shut-Off 2-Way Diverter

INFRARED TAPS. Important: Electronic taps saving water, saving power, promoting hygiene DB100 DB125 DB150 DB175 DBL200 DBL225 DBL250 DBL275

Installation Instructions

Installation Instructions

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Installation Instructions

Oletto Single Lever Bar/Prep Faucet

SAVE FOR CONSUMER INSTALLATION / OWNER S MANUAL. Includes: Tools: Mystic - Pull-Out Kitchen Faucet LKMY1041CR LKMY1041NK LKLFMY1041CR LKLFMY1041NK D 1

1/7 HANDLE TRIM INSTALLATION

Single Lever Pull-Down Kitchen Faucet

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

Installation Instructions

Transcription:

Installation and Owner s Manual AEF-300/300T SERIES SENSOR FAUCET SYSTEMS HYBRIDFLO FIXEDFLO HEALTHFLO AEF-300 AEF-301 AEF-302 AEF-303 AEF-304 AEF-306 AEF-307 AEF-320 AEF-321 AEF-322 AEF-323 AEF-300T AEF-302T AEF-304T AEF-305T Advanced Modern Technologies Corporation 19800 Nordhoff Place, Chatsworth, CA 91311 Tel: (818) 883-2682 Toll Free: (800) 874-7822 Fax: (818) 883-2620 www.amtcorporation.com REV. 07/17

Table of Contents Important Pre-Installation and Installation Notes --------------------------------------------------- 3 Install Deck Mount Spout (300 Series) ---------------------------------------------------------------- 4 Install Deck Mount Spout (300T Series) -------------------------------------------------------------- 4 Install Wall Mount Spout (Model AEF-303) ----------------------------------------------------------- 5 Install Wall Mount Spout (Model AE-304) ------------------------------------------------------------- 5 Install Wall Mount Spout (Model AEF-304T) --------------------------------------------------------- 6 Install Wall Mount Spout (Model AEF-305T) --------------------------------------------------------- 6 Install Control Box ------------------------------------------------------------------------------------------ 7 Activate Faucet System ----------------------------------------------------------------------------------- 8 Sensor Distance Adjustment ----------------------------------------------------------------------------- 9 Battery Replacement -------------------------------------------------------------------------------------- 10 Care and Maintenance ------------------------------------------------------------------------------------ 11 Troubleshooting for 300 Series ------------------------------------------------------------------------- 12 Troubleshooting for 300T Series ----------------------------------------------------------------------- 13 Identify Your Faucet System ---------------------------------------------------------------------------- 14 Spout Parts Diagram -------------------------------------------------------------------------------------- 15-17 Spout Parts List --------------------------------------------------------------------------------------------- 18 HYBRIDFLO Operating System Diagram and Parts List ---------------------------------------- 19 FIXEDFLO Operating System Diagram and Parts List ------------------------------------------- 20 HEALTHFLO Operating System Diagram and Parts List ---------------------------------------- 21 Faucet System Accessories ------------------------------------------------------------------------------ 22 Optional Accessories Setup ------------------------------------------------------------------------------ 23 Warranty ------------------------------------------------------------------------------------------------------- 24 2

Important Pre-Installation and Installation Notes Please read the following notes prior to installation of your new AMTC faucet system. Failure to do so could result in personal injury, property damage, and/or damage to the product. 1. Only qualified personnel should be allowed to install, disassemble, repair, or modify the faucet system. Failure to do so may result in shock, product damage, or product malfunction. 2. Install all plumbing in accordance with applicable codes and regulations. 3. Prior to installation, check the hot/cold water supply pressure. The recommended working pressure range is 20 psi - 80 psi (138 kpa - 551 kpa). If the supply pressure is greater than 80 psi (551 kpa), reduce to the recommended range by using a pressure reducing device (sold separately). Water pressures over 80 psi are not recommended for most plumbing fixtures. Check your local plumbing code for details. 4. Prior to installation, it is recommended to install hot/cold water supply hoses (not included) that are at least 20 (508mm) in length to allow for proper location installation of faucet system control box. 5. Prior to installation, flush all water lines until water is clear before connecting hose from supply stops to faucet system control box. 6. Faucet system control box MUST be installed securely against BACK WALL using mounting holes and supplied mounting hardware as shown in installation diagram on next page. IMPORTANT: Be sure to install faucet system control box in the correct orientation as shown. Otherwise, internal components may become damaged and cause product to malfunction. Warranty may become void. 7. DO NOT use teflon tape or plumber's putty on any threads. 8. DO NOT over-tighten hose connections. Over-tightening may cause damage to the seal. 9. Make sure that power cables DO NOT come in contact with any water supply hose/pipe. 10. Once faucet system installation is complete (and before you turn on water stops) it is recommended to flush out any residual debris in water line. To do this remove aerator on faucet spout. Open water stops. Activate the faucet to flow water by placing your hand in front of the sensor. Let the water flow for a few seconds and re-install aerator. (This action will flush out residual debris in water line to prevent clogging of aerator). 11. Check supply hoses/pipes for any leaks. 12. Set temperature output according to local codes and regulations. The recommended supply temperature range is 39 F - 104 F (4 C - 40 C). Check your local plumbing code for details. 3

Install Deck Mount Spout (300 Series) This section is for 300 Series deck mount spouts only. (Models AEF-300, AEF-301, AEF-302, AEF-306, AEF-307, AEF-320, AEF-321, AEF-322, AEF-323) Figure 1 Note: A 1 (25mm) diameter (center) hole must be created to install these models. 1. Secure spout to the countertop or sink with the included mounting bracket and nut. Tighten using included installation wrench. Note: If installing spout onto 3-hole application also use included outer hole screws with nuts. If using a cover plate use mounting bracket and cover plate screws with nuts. 2. Make sure that the spout is mounted with the tip directed towards the center of the basin as shown in Figure 1. 3. Make sure sensor cable is not pinched by the mounting bracket (sensor cable should be run on the flat side of the mounting bracket). Nut Rubber base gasket Mounting bracket Sensor cable Hose connector Installation wrench Install Deck Mount Spout (300T-Series) This section is for 300T Series deck mount spouts only. (Models AEF-300T, AEF-302T) Note: A 1-3/8 (35mm) diameter (center) hole must be created to install these models. Figure 2 1. Secure spout to the countertop or sink with the included mounting nut. Tighten using wrench. 2. Make sure that the spout is mounted with the tip directed towards the center of the basin as shown in Figure 2. Rubber base gasket Hose connector Nut Sensor cable (inside) 4

Install Wall Mount Spout (Model AEF-303) Note: The addition of a 2 x 4 stringer behind the spout installation location is highly recommended. 1. Drill a 3/4 (19mm) diameter hole at the spout mounting location (center) for the threaded rod and sensor cable to pass through as pictured in Figure 3. 2. Feed spout threaded rod and sensor cable through the 3/4 (19mm) hole in center. STEP 8 2 X 4 Stringer 2 x 4 Studs Figure 3 Finished wall 3/4 hole for spout and sensor cable 3. Place spout against wall and fasten securely with the provided nut and metal washer as pictured in Figure 4. Tighten nut behind wall. Nut Metal washer Threaded rod Figure 4 4. Connect 90 hose adapter to spout threaded rod as pictured in Figure 4. Do not over-tighten. 90 hose adapter 5. Connect supply hose to 90 hose adapter as pictured in Figure 4. Do not over-tighten. Supply hose Finished wall Sensor cable Install Wall Mount Spout (Model AEF-304) Note: The addition of two 1 x 4 stringers behind the spout and sensor installation location is highly recommended. Important: Recommended distance from center hole of spout to center hole of sensor is 4.5 (114mm). STEP 8 Spout 1 X 4 Stringers Figure 5 Finished wall 3/4 hole for spout 1-1/2 hole for sensor Spout Installation 1. Drill a 3/4 (19mm) diameter hole at the spout mounting location (center) for the threaded rod to pass through as pictured in Figure 5. Sensor 2 x 4 Studs 2. Place spout against wall and fasten securely with the provided nut and metal washer as pictured in Figure 6. Tighten nut behind wall. 3. Connect 90 hose adapter to threaded rod as pictured in Figure 6. Do not over-tighten. 90 hose adapter Nut Metal washer Finished wall Figure 6 4. Connect supply hose to 90 hose adapter as pictured in Figure 6. Do not over-tighten. Sensor Installation Supply hose Threaded rod 1. Drill a 1-1/2 (38mm) diameter hole at the sensor mounting location (center) for the threaded rod and sensor cable to pass through as pictured in Figure 7. Sensor cable Nut Washer (x2) Sensor Figure 7 2. Place sensor against wall and fasten securely with the provided (2) washers and nut as pictured in Figure 7. Tighten nut behind wall. Finished wall Threaded rod 5

Install Wall Mount Spout (Model AEF-304T) Note: The addition of a 2 x 4 stringer behind the spout installation location is highly recommended. 1. Drill a 1-1/8 (29mm) diameter hole at the spout mounting location (center) for the supply hose and sensor cable to pass through as pictured in Figure 8. 2. Drill three (3) pilot holes 3/16 (5mm) in diameter and insert anchors until flush. Tap lightly with a hammer if needed. 3. Feed the supply hose and sensor cable through the 1-1/8 (29mm) hole in center as pictured in Figure 9A. STEP 8 2 X 4 Stringer 2 x 4 Studs Finished wall 1-1/8 hole for spout Figure 8 Holes for screws/anchors 4. Place spout against wall and fasten securely with the provided screws as pictured in Figure 9B. 5. Fasten the escutcheon to the bracket until hand-tight as pictured in Figure 9B. Figure 9A Figure 9B Escutcheon Finished wall (x3) Install Wall Mount Spout (Model AEF-305T) Note: The addition of a 2 x 4 stringer behind the spout installation location is highly recommended. Important: There is a minimum requirement of 11 (275 mm) of clearance from the bottom of the aerator to the basin in order for the sensor to function properly. Any distance shorter than 11 (275mm) may result in sensor error from the reflection of the sink. 1. Drill a 1-1/2 (38mm) diameter hole at the spout mounting location (center) for the threaded rod and sensor cable to pass through as pictured in Figure 10. STEP 8 2 X 4 Stringer 2 x 4 Studs Figure 10 Finished wall 1-1/2 hole for spout 2. Feed the threaded rod and sensor cable through the 1-1/2 (38mm) hole in center as pictured in Figure 11. 90 hose adapter Nut Washer (x2) Figure 11 3. Place spout against wall and fasten securely with the provided (2) washers and nut as pictured in Figure 11. Sensor cable 4. Connect supply hose to 90 hose adapter as pictured in Figure 11. Do not over-tighten. Supply hose Threaded rod Finished wall 6

Install Control Box Note: Make sure to read the Pre-installation notes on page 3 of this manual before proceeding with control box installation. 1. Determine the proper location for the installation of the control box. 2. Mount the control box on the back wall using the two included screws. If necessary, drill two 3/16 (5mm) holes to use the included wall anchors as pictured in Figure 12 below. IMPORTANT: Faucet system control box MUST be installed securely against BACK WALL using mounting holes and supplied mounting hardware as pictured in Figure 12 below. Be sure to install faucet system control box in the correct orientation as shown. Otherwise, internal components may become damaged and cause product to malfunction. Warranty may become void. 3. Once control box is mounted properly, connect the spout hose and water supply hose as pictured in Figure 12. Note: Figure 12 illustrates single water hose installation. If using a hot/cold water mixing valve install hot/cold water supply hoses to mixing valve. If using a thermostatic mixing valve make sure to connect hot/cold water supply hoses accordingly to assure proper operation. 4. Connect the sensor cable to sensor cable connector on control box as pictured in Figure 12. Model AEF-301 Pictured Figure 12 Countertop Sensor cable Spout hose Control box Mounting screws and anchors Sensor cable connector Reset/sensor distance adjustment button AC power adapter and hydro-generator connector (optional) Water supply hose Motor cable connector 7

Activate Faucet System This section is for 300 Series spouts only. (Models AEF-300, AEF-301, AEF-302, AEF-303, AEF-304, AEF-306, AEF-307, AEF-320, AEF-321, AEF-322, AEF-323) Once you have connected the sensor cable to control box as pictured in Figure 12 you are ready to activate the faucet system. To activate: 1. Turn on the water supply at the stop valves and inspect all the connections for any leaks as pictured in Figure 13. 2. Place hand approx. 4 (102mm) in front of sensor window to activate water flow on as pictured in Figure 14. 3. Red light will flash and water will flow while hand is in sensing area. Open Figure 13 Close Stop Valve Figure 14 4. Remove hand away from sensing area and faucet will shut off within 2 seconds. Note: Faucet system includes a 10-second continuous water flow shut-off timer. Note: Sensing distance may be adjusted to read shorter or longer. (see Distance Adjustment Section for procedure on page 9). Sensor window and sensor light I This section is for 300T Series spouts only. (Models AEF-300T, AEF-302T, AEF-304T, AEF-305T) Once you have connected the sensor cable to control box as pictured in Figure 12 you are ready to activate the faucet system. Figure 15 To activate: 1. Turn on the water supply at the stop valves and inspect all the connections for any leaks as pictured in Figure 15. 2. Push and hold reset button on control box (pictured in Figure 16A). Water will turn ON for approx. 5-6 seconds then turn OFF. Release reset button. Sensor will now self-adjust (process takes 15-20 seconds). Water will turn ON and OFF by itself one time after the sensor has self-adjusted. 3. Place hand in front of sensor window to activate water flow on as pictured in Figure 16B. 4. Red light will flash and water will flow while hand is in sensing area. Open Close Stop Valve Figure 16B 5. Remove hand away from sensing area and faucet will shut off within 2 seconds. Note: Faucet system includes a 10-second continuous water flow shut-off timer. Sensor window I Control box E Figure 16A Reset button Sensor window Sensor light Nozzle 8

Sensor Distance Adjustment This section is for 300 Series spouts only. (Models AEF-300, AEF-301, AEF-302, AEF-303, AEF-304, AEF-306, AEF-307, AEF-320, AEF-321, AEF-322, AEF-323) Figure 17 1. Push and hold reset button on control box (pictured in Figure 17). Water will turn ON for approximately 5 seconds and then OFF. Release reset button. The sensor is now in setup mode. 2. Position the palm of your hand vertically and hold it at desired sensing distance. You will see a quick flashing red light in sensor window. 3. Hold your hand at the desired sensor distance for approximately 15 seconds while red light is flashing until solid red light comes on. Faucet will turn ON and then OFF by itself once when sensor range is set. Sensor window and sensor light EI Control box Reset button This section is for 300T Series spouts only. (Models AEF-300T, AEF-302T, AEF-304T, AEF-305T) Figure 18 1. Locate the reset button on the control box as pictured in Figure 18. 2. Push and hold reset button on control box (pictured in Figure 18). Water will turn ON for approx. 5-6 seconds then turn OFF. Release reset button. Sensor will now self-adjust (process takes 15-20 seconds). Water will turn ON and OFF by itself one time after the sensor has self-adjusted. Sensor window I I Sensor light Control box EReset button 9

Battery Replacement 1. Remove screw on the upper right hand corner of the battery pack on the control box as pictured in Figures 19 and 20. 2. Twist the battery pack counter-clockwise to release it from the latch as pictured in Figure 21. Control box Screw (USE 4 - SIZE C) (USE 4 - SIZE C) Latch (twist to open) Figure 19 Latch (twist to open) Latch (twist to open) Figure 20 Figure 21 3. Remove battery pack cover as pictured in Figure 22. 4. Detach battery pack from control box as pictured in Figure 23. 5. Remove all four batteries and replace with four new batteries (4 x C-Cell) as pictured in Figure 23. Note: Make sure all four batteries are installed in the right direction. + - - + - + + - (USE 4 - SIZE C) Figure 22 Figure 23 6. Re-insert battery pack into control box as pictured in Figure 24. 7. Re-install battery pack cover as pictured in Figure 24. 8. Rotate clockwise to latch into place and secure with screw as pictured in Figure 25. (USE 4 - SIZE C) (USE 4 - SIZE C) Latch (twist to close) Latch (twist to close) Figure 24 Figure 25 10

Care and Maintenance Care 1. Avoid scratching the sensor and/or sensor window when cleaning the spout. I 2. Avoid using any harsh cleaning materials that may scratch the surface of the spout. Nozzle 3. Do not use any polishing powder, thinner, benzene, acid, alkaline detergent, or nylon scrub brushes, as they can damage the surface of the spout. Sensor window 4. To clean, use a dampened soft cloth with water to safely wipe the surface of the spout. You may use some diluted dishwashing detergent if necessary. Do not use any harsh chemicals that may damage the surface of the spout. Figure 26 Maintenance 1. Periodically check to make sure that spout is not loose. If loose tighten all mounting screws and/or nuts. 2. Periodically check to make sure that control box is installed properly and that no cables or supply hoses have come loose. If loose then tighten hoses and re-install cables. 3. Periodically check all water hose connections for signs of leakage. Tighten or replace water hoses if leakage is present. Clean the Water Filter (HYBRIDFLO & FIXEDFLO Only) When the water filter and/or nozzle is clogged, the flow rate will decrease and/or cause inconsistent water flow. To clean the water filter: 1. Turn the water OFF at the stop valves. 2 Remove water filter (Figure 28) by unscrewing from control box. 3. Clean the water filter completely. 4. Re-install water filter (make sure not to damage o-ring). 5. Turn the water ON at the stop valves. I I Sensor window Nozzle Figure 27 Control box Clean the Nozzle To clean the nozzle: 1. Remove the nozzle (Figure 26 and 27) from spout. 2. Clean the nozzle completely and remove any debris. 3. Re-install the nozzle in the spout. E Water Filter Figure 28 11

Troubleshooting for 300 Series Problem Faucet does not activate Motor activates but no water comes out of the faucet Water does not shut off Solid red LED light in sensor window stays ON Spout drips Irregular/low flow Water temperature is too high Water temperature is too low Solution 1. Water stop valves may be turned OFF. Make sure the stop valves are ON. 2. Check if red LED blinks on sensor window. If no light is present: A. Check or replace batteries (and/or alternate power source, if available). B. Make sure sensor cable is properly plugged into control box. 3. Check that motor plug is properly plugged into control box. 4. Inspect sensor window. If dirty, wipe down with soft cloth. If broken, replace. 5. Check motor mechanism by: A. Remove motor cover. B. Manually turn gears (clockwise). If gears do not turn, replace motor drive assembly. 1. Water stop valves may be turned OFF. Make sure the stop valves are ON. 2. Check water filter by: A. Shut off stop valves and make sure water is completely OFF. B. Remove water filter and clean if necessary. C. Re-install water filter. 3. Check nozzle/aerator. If dirty, clean or replace. 4. Reset faucet by: A. Pressing green button on the control box and keep it pressed in until you see a solid red light come on in sensor window (about 5 seconds). B. Let go of the button and place the palm of your hand at desired sensor reading distance. C. Hold hand in place (about 15 seconds) until water turns ON and then OFF by itself once. 1. Test motor by: A. Remove motor cover. B. Manually turn gears (clockwise). If gears do not turn or if they turn non-stop, replace motor drive assembly. 2. Check flow pin assembly by: A. Shut off stop valves and make sure water is completely OFF. B. Remove motor cover. C. Remove motor assembly. D. Remove and inspect flow pin assembly. Clean or replace components. E. Re-install all components and turn water stop valves back ON. 3. Test sensor range by: A. Pressing green button on the control box and keep it pressed in until you see a solid red light come on in sensor window (about 5 seconds). B. Let go of the button and place the palm of your hand at desired sensor reading distance. C. Hold hand in place (about 15 seconds) until water turns ON and then OFF by itself once. 4. Check batteries (and/or alternate power source, if available). 1. Check batteries are installed in the right direction and not fully drained (also check alternate power source, if available). Solid red light may be a low power indicator. 2. Control box may be damaged. If so, replace control box. 3. Sensor may be damaged. If so, replace sensor cable. 1. Remove nozzle/aerator and turn water ON and OFF by activating sensor 5 to 6 times. If dripping continues, follow instructions in Irregular/low flow below. 1. Check stop valve. If not fully open, open fully. 2. Inspect nozzle/aerator. If dirty, clean or replace. 3. Check water filter by: A. Shut off stop valves and make sure water is completely OFF. B. Remove water filter and clean if necessary. C. Re-install water filter. 4. Check flow pin assembly by: A. Shut off stop valves and make sure water is completely OFF. B. Remove motor cover. C. Remove motor assembly. D. Remove and inspect flow pin assembly. Clean or replace components. E. Re-install all components and turn water stop valves back ON. 1. Make sure stop valves are fully open. 2. Calibrate temperature adjustment in mixing valve to lower output temperature. 1. Make sure stop valves are fully open. 2. Calibrate temperature adjustment in mixing valve to increase output temperature. For Additional Assistance Contact Technical Support at 800-874-7822 or Visit our Website at www.amtcorporation.com 12

Troubleshooting for 300T Series Problem Faucet does not activate Motor activates but no water comes out of the faucet Solution 1. Water stop valves may be turned OFF. Make sure the stop valves are ON. 2. Check if red LED blinks on sensor window. If no light is present: A. Check or replace batteries (and/or alternate power source, if available). B. Make sure sensor cable is properly plugged into control box. 3. Check that motor plug is properly plugged into control box. 4. Inspect sensor window. If dirty, wipe down with soft cloth. If broken, replace. 5. Check motor mechanism by: A. Remove motor cover. B. Manually turn gears (clockwise). If gears do not turn, replace motor drive assembly. 1. Water stop valves may be turned OFF. Make sure the stop valves are ON. 2. Check water filter by: A. Shut off stop valves and make sure water is completely OFF. B. Remove water filter and clean if necessary. C. Re-install water filter. 3. Check nozzle/aerator. If dirty, clean or replace. 4. Reset faucet by: A. Pressing red button on the control box and keep it pressed in until water stops flowing (about 5 seconds). B. Let go of the button. Sensor will self-adjust (about 15 seconds). Water will turn ON and Off once by itself when the sensor adjustment process is completed. Water does not shut off Solid red LED light in sensor window stays ON Spout drips Irregular/low flow Water temperature is too high Water temperature is too low 1. Test motor by: A. Remove motor cover. B. Manually turn gears (clockwise). If gears do not turn or if they turn non-stop, replace motor drive assembly. 2. Check flow pin assembly by: A. Shut off stop valves and make sure water is completely OFF. B. Remove motor cover. C. Remove motor assembly. D. Remove and inspect flow pin assembly. Clean or replace components. E. Re-install all components and turn water stop valves back ON. 3. Test sensor range by: A. Pressing red button on the control box and keep it pressed in until water stops flowing (about 5 seconds). B. Let go of the button. Sensor will self-adjust (15-20 seconds). Water will turn ON and Off once by itself when the sensor adjustment process is completed. 4. Check batteries (and/or alternate power source, if available). 1. Check batteries are installed in the right direction and not fully drained (also check alternate power source, if available). Solid red light may be a low power indicator. 2. Control box may be damaged. If so, replace control box. 3. Sensor may be damaged. If so, replace sensor cable. 1. Remove nozzle/aerator and turn water ON and OFF by activating sensor 5 to 6 times. If dripping continues, follow instructions in Irregular/low flow below. 1. Check stop valve. If not fully open, open fully. 2. Inspect nozzle/aerator. If dirty, clean or replace. 3. Check water filter by: A. Shut off stop valves and make sure water is completely OFF. B. Remove water filter and clean if necessary. C. Re-install water filter. 4. Check flow pin assembly by: A. Shut off stop valves and make sure water is completely OFF. B. Remove motor cover. C. Remove motor assembly. D. Remove and inspect flow pin assembly. Clean or replace components. E. Re-install all components and turn water stop valves back ON. 1. Make sure stop valves are fully open. 2. Calibrate temperature adjustment in mixing valve to lower output temperature. 1. Make sure stop valves are fully open. 2. Calibrate temperature adjustment in mixing valve to increase output temperature. For Additional Assistance Contact Technical Support at 800-874-7822 or Visit our Website at www.amtcorporation.com 13

Identify Your Faucet System Control Box Sensor Cable Connector Serial Number (Below Sensor Cable Connector) Motor Cover (Black, Green, or Blue) Reset Button (Green or Red) Identify Your Operating System Identify Your Faucet Model - Green Reset Button = 300 Series - Red Reset Button = 300T Series AEF-300 AEF-301 AEF-302 AEF-303 - Black Motor Cover = HYBRIDFLO AEF-304 AEF-306 AEF-307 - Green Motor Cover = FIXEDFLO - Blue Motor Cover = HEALTHFLO AEF-320 AEF-321 AEF-322 AEF-323 AEF-300T AEF-302T AEF-304T AEF-305T 14

Spout Parts Diagrams Make sure you identify your faucet system before referring to the Parts List. Model AEF-300 1A Model AEF-301 1B 2A 2B 4A 3A 4B 3B 5A 6 5B 6 Model AEF-302 1C Model AEF-303 1D 4D 2D 2C 4C 3C 6 5D 3D 5C 15

Spout Parts Diagrams Make sure you identify your faucet system before referring to the Parts List. Model AEF-304 Model AEF-306 4E 1E 1F 5E 2F 4F 3F 5F 6 3E Model AEF-307 Model AEF-320 Model AEF-321 1G 1M 1N 2M 2N 4M 4N 3M 3N 2G 5M 5N 4G 3G Model AEF-322 Model AEF-323 5G 6 1P 1Q 6 16 2P 4P 5P 3P 2Q 4Q 5Q 3Q

Spout Parts Diagrams Make sure you identify your faucet system before referring to the Parts List. Model AEF-300T Model AEF-302T 4H 1H 4J 1J Model AEF-304T Model AEF-305T (x3) 4K 1L 2L 5L 4L 1K 17

Spout Parts List REF # PART # DESCRIPTION 1A SP300 AEF-300 Deck Mounted Spout (Chrome Finish) 1H SP300T AEF-300T Deck Mounted Spout (Chrome Finish) - Includes Sensor Cable 1B SP301 AEF-301 Deck Mounted Spout (Chrome Finish) 1C SP302 AEF-302 Deck Mount Gooseneck Spout (Chrome Finish) 1J SP302T AEF-302T Deck Mount Gooseneck Spout (Chrome Finish) - Includes Sensor Cable 1D SP303 AEF-303 Back Mounted Gooseneck Spout (Chrome Finish) 1E SP304 AEF-304 Back Mounted Spout (Chrome Finish) 1K SP304T AEF-304T Back Mounted Spout (Chrome Finish) - Includes Sensor Cable 1L SP305T AEF-305T Back Mounted Spout (Chrome Finish) - Includes Sensor Cable 1F SP306 AEF-306 Deck Mounted Spout (Chrome Finish) 1G SP307 AEF-307 Deck Mounted Spout (Chrome Finish) 1M SP320 AEF-320 Deck Mounted Spout (Chrome Finish) 1N SP321 AEF-321 Deck Mounted Spout (Chrome Finish) 1P SP322 AEF-322 Deck Mounted Spout (Chrome Finish) 1Q SP323 AEF-323 Deck Mounted Spout (Chrome Finish) 2A RB300 Rubber Base for AEF-300 2B RB301 Rubber Base for AEF-301 2C RB302 Rubber Base for AEF-302 2D RB303 Rubber Base for AEF-303 2L RB305T Rubber Base for AEF-305T 2F RB306 Rubber Base for AEF-306 2G RB307 Rubber Base for AEF-307 2M RB320 Rubber Base for AEF-320 2N RB321 Rubber Base for AEF-321 2P RB322 Rubber Base for AEF-322 2Q RB323 Rubber Base for AEF-323 3A SCA300 Sensor Cable Assembly For AEF-300 3B SCA301 Sensor Cable Assembly For AEF-301 3C SCA302 Sensor Cable Assembly For AEF-302 3D SCA303 Sensor Cable Assembly For AEF-303 3E SCA304 Sensor Cable Assembly For AEF-304 3F SCA306 Sensor Cable Assembly For AEF-306 3G SCA307 Sensor Cable Assembly For AEF-307 3M SCA320 Sensor Cable Assembly For AEF-320 3N SCA3321 Sensor Cable Assembly For AEF-321 3P SCA322 Sensor Cable Assembly For AEF-322 3Q SCA323 Sensor Cable Assembly For AEF-323 4A MH300 Mounting Hardware for AEF-300 4H MH300T Mounting Hardware for AEF-300T 4B MH301 Mounting Hardware for AEF-301 4C MH302 Mounting Hardware for AEF-302 4J MH302T Mounting Hardware for AEF-302T 4D MH303 Mounting Hardware for AEF-303 4E MH304 Mounting Hardware for AEF-304 4K MH304T Mounting Hardware for AEF-304T 4L MH305T Mounting Hardware for AEF-305T 4F MH306 Mounting Hardware for AEF-306 4G MH307 Mounting Hardware for AEF-307 4M MH320 Mounting Hardware for AEF-320 4N MH321 Mounting Hardware for AEF-321 4P MH322 Mounting Hardware for AEF-322 4Q MH323 Mounting Hardware for AEF-323 5A WFH300 Water Flex Hose for AEF-300 5B WFH301 Water Flex Hose for AEF-301 5C WFH302 Water Flex Hose for AEF-302 5D WFH303 Water Flex Hose for AEF-303 5E WFH304 Water Flex Hose for AEF-304 5L WFH305T Water Flex Hose for AEF-305T 5F WFH306 Water Flex Hose for AEF-306 5G WFH307 Water Flex Hose for AEF-307 5M WFH320 Water Flex Hose for AEF-320 5N WFH321 Water Flex Hose for AEF-321 5P WFH322 Water Flex Hose for AEF-322 5Q WFH323 Water Flex Hose for AEF-323 6 WR Installation Wrench 18

HYBRIDFLO Operating System Parts List 1A 1B 6 3 7A 10A 2 4 5 8A (USE 4 - SIZE C) 9A 11 12 13A 14 REF# 15A1 DESCRIPTION = HYBRIDFLO Operating System (300 Series) REF # PART # DESCRIPTION 1A 1B CBA CBA-T Control Box Assembly for M odels AEF-300, 301, 302, 303, 304, 306, 307, 320, 321, 322, 323 - GREEN Button Control Box Assembly for M odels AEF-300T, 302T, 304T & 305T Only - RED Button 2 SC3XX-2 Control Box M ounting Screws - Set of 2 3 CBAT C Cell Alkaline Battery (Each) 4 BP Battery Pack 5 BPC Battery Pack Cover 15A2 = HYBRIDFLO Operating System (300T Series) 6 VB Valve Body 7A WF Water Filter Assembly 8A BRVHY-P HYBRIDFLO Flow Pin 9A BRVHY-B HYBRIDFLO Plunger 10A BRVHY-PB HYBRIDFLO Flow Pin Assembly 16A + = HYBRIDFLO Maintenance Kit 11 MDA M otor Drive Assembly 12 SC3XX-4 M otor M ounting Screws - Set of 4 13A MCHY M otor Cover for HYBRIDFLO (Black Cover) 14 MCS M otor Cover Screw 15A1 15A2 OSRK-HY OSRKT-HY Operating System Replacement Kit for HYBRIDFLO for M odels AEF-300, 301, 302, 303, 304, 306, 307, 320, 321, 322, 323 - GREEN Button Operating System Replacement Kit for HYBRIDFLO - For models AEF-300T, 302T, 304T & 305T Only - RED Button 16A MDA-BRVHY HYBRIDFLO M aintenance Kit 19

FIXEDFLO Operating System Parts List 1A 1B 6 3 7A 10B1 2 4 5 10B2 (USE 4 - SIZE C) 8B1 8B2 9B 11 REF# 15B1-1 15B2-1 16B-1 REF# 15B1-2 15B2-2 16B-2 DESCRIPTION For 0.5gpm = FIXEDFLO Operating System (300 Series) = FIXEDFLO Operating System (300T Series) + = FIXEDFLO Maintenance Kit DESCRIPTION For 0.35gpm = FIXEDFLO Operating System (300 Series) = FIXEDFLO Operating System (300T Series) + = FIXEDFLO Maintenance Kit 12 13B 14 REF # PART # DESCRIPTION 1A 1B CBA CBA-T Control Box Assembly for M odels AEF-300, 301, 304, 306, 307 - GREEN Button Control Box Assembly for M odels AEF-300T, 302T, 304T & 305T Only - RED Button 2 SC3XX-2 Control Box Mounting Screws - Set of 2 3 CBAT C Cell Alkaline Battery (Each) 4 BP Battery Pack 5 BPC Battery Pack Cover 6 VB Valve Body 7A WF Water Filter Assembly 8B1 BRVFF-P-05 FIXEDFLO Flow Pin - 0.5gpm 8B2 BRVFF-P-035 FIXEDFLO Flow Pin - 0.35gpm 9B BRVFF-B FIXEDFLO Plunger 10B1 BRVFF-PB-05 FIXEDFLO Flow Pin Assembly - 0.5gpm 10B2 BRVFF-PB-035 FIXEDFLO Flow Pin Assembly - 0.35gpm 11 MDA Motor Drive Assembly 12 SC3XX-4 Motor Mounting Screws - Set of 4 13B MCFF Motor Cover for FIXEDFLO (Green Cover) 14 MCS Motor Cover Screw 15B1-1 OSRK-FF-05 15B1-2 OSRK-FF-035 15B2-1 OSRKT-FF-05 15B2-2 OSRKT-FF-035 Operating System Replacement Kit for FIXEDFLO for M odels AEF-300, 301, 304, 306, 307 - GREEN Button - 0.5gpm Operating System Replacement Kit for FIXEDFLO for M odels AEF-300, 301, 304, 306, 307 - GREEN Button - 0.35gpm Operating System Replacement Kit for FIXEDFLO - For models AEF-300T, 302T, 304T & 305T Only - RED Button - 0.5gpm Operating System Replacement Kit for FIXEDFLO - For models AEF-300T, 302T, 304T & 305T Only - RED Button - 0.35gpm 16B-1 MDA-BRVFF-05 FIXEDFLO M aintenance Kit - 0.5gpm 16B-2 MDA-BRVFF-035 FIXEDFLO M aintenance Kit - 0.35gpm 20

HEALTHFLO Operating System Parts List 1A 1B 6 3 7C 10C 2 4 5 8C (USE 4 - SIZE C) 9C 11 12 13C 14 REF# 15C1 DESCRIPTION = HEALTHFLO Operating System (300 Series) REF # PART # DESCRIPTION 1A CBA Control Box Assembly for M odels AEF-302, 303, 320, 321, 322, 323 - GREEN Button 2 SC3XX-2 Control Box M ounting Screws - Set of 2 3 CBAT C Cell Alkaline Battery (Each) 4 BP Battery Pack 16C + = HEALTHFLO Maintenance Kit 17C = HEALTHFLO Flow Control (Used Instead of an Aerator in Spout) 5 BPC Battery Pack Cover 6 VB Valve Body 7C OSP Operating System Plug 8C BRVHF-P HEALTHFLO Flow Pin 9C BRVHF-B HEALTHFLO Plunger 10C BRVHF-PB HEALTHFLO Flow Pin Assembly 11 MDA M otor Drive Assembly 12 SC3XX-4 M otor M ounting Screws - Set of 4 13C MCHF M otor Cover for HEALTHFLO (Blue Cover) 14 MCS M otor Cover Screw 15C1 OSRK-HF Operating System Replacement Kit for HEALTHFLO for M odels AEF-302, 303, 320, 321, 322, 323 - GREEN Button 16C MDA-BRVHF HEALTHFLO M aintenance Kit 17C HFFC HEALTHFLO Flow Control 21

Faucet System Accessories (SOLD SEPARATELY) Part: AD01 Description: Plug-in 6 Volt AC Power Adapter The plug-in 6-volt AC power adapter is used as an alternate power source with AMTC s sensor faucet systems. The AC adapter easily plugs into the faucet system to provide for many years of dependable operation and eliminates the need to routinely replace batteries. The AC adapter is recommended for high traffic facilities where the faucets get frequent use such as office buildings, airports, convention centers, schools, etc. When the AC power adapter is used in conjunction with the standard battery pack, the batteries become a back up power source that continues to power the faucet system in case of an electrical power failure. AD01 Part: CP4, CP8, CP8-1 Description: Cover Plates (4, 8, 8 Extra-Long) The cover plate is used with AMTC s sensor faucet systems. The cover plates are used in standard 4 or 8 center set applications. CP4 CP8 CP8-1 Part: HG01 Description: Hydro-Powered Electric Generator The Hydro-Powered Electric Generator is a device that is used as an alternate power source with AMTC s sensor faucet systems. The device easily adapts to the faucet system to provide for many years of dependable operation and eliminates the need to routinely replace batteries or use electrical power. The hydro-powered electric generator is recommended for high traffic facilities where the faucets get frequent use such as office buildings, restaurants, hospitals, schools, airports, convention centers, etc. HG01 Part: MV Description: Mechanical Mixing Valve The MV is used as a water mixing device with AMTC s sensor faucet systems. Mechanical Mixing valves (MV) are used in applications where hot and cold water mixing is needed. The MV provides water at a safe and usable temperature in situations where the control of the temperature of the water discharging from a terminal fitting is of the utmost importance, i.e. within airports, convention centers, schools, nursing homes, etc. The valve is designed to mix the flow of water discharging from the water outlets. The Mechanical Mixing Valve (MV) is complete with check valves at both hot and cold inlets and is made of low lead brass. MV Part: TMV Description: Thermostatic Mixing Valve The TMV is used as a water mixing device with AMTC s sensor faucet systems. Thermostatic mixing valves (TMV) are used in applications where hot and cold water mixing is needed and where the user must be protected from the danger of scalding caused by hot water or where required by law. The TMV provides water at a safe and usable temperature in situations where the control of the temperature of the water discharging from a terminal fitting is of the utmost importance, i.e. within restaurants, hospitals, schools, airports, convention centers, nursing homes, etc. The valve is designed to mix the flow of water discharging from the water outlets. The Thermostatic Mixing Valve (TMV) is complete with check valves at both hot and cold inlets and is made of low lead brass. 22 TMV

Optional Accessories Setup *Faucet system pictured with optional thermostatic mixing valve and hydro-generatorinstalled To Spout Hydro-Powered Electric Generator w/rechargeable Battery (Optional) 4-Size C Batteries (Included) Thermostatic Mixing Valve (Optional) Optional water mixing and power options available: Part: MV Mechanical Mixing Valve Part: TMV Thermostatic Mixing Valve Part: AD01 6 VAC Power Adapter Part: AD01-3 6 VAC Power Adapter w/daisy Chain Extension Part: HG01 Hydro-Powered Electric Generator 23

Warranty AMTC WARRANTS ITS PRODUCTS TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF FIVE (5) YEARS FROM DATE OF PURCHASE, WHEN PROPERLY INSTALLED AND UNDER NORMAL USE AND SERVICE. THESE PROVISIONS DO NOT INCLUDE THE BATTERIES SHIPPED WITH THE PRODUCTS. A DEFECTIVE PRODUCT MAY BE RETURNED TO AMTC OR ITS AUTHORIZED REPRESENTATIVES WITHIN FIVE (5) YEARS FROM DATE OF PURCHASE WITH THE PROPER INVOICE OF PURCHASE. AMTC, AT ITS DISCRETION, WILL REPLACE OR REPAIR DEFECTIVE PRODUCT AT NO CHARGE. CLAIMS FOR LABOR, TRANSPORTATION, AND ANY OTHER INCIDENTAL COSTS WILL NOT BE ALLOWED. AMTC WILL NOT BE RESPONSIBLE FOR ANY CONSIDERABLE DAMAGES OF ANY KIND WHATSOEVER. FOR TECHNICAL SUPPORT PLEASE CALL TOLL FREE 1-800-874-7822 OR VISIT OUR WEBSITE AT WWW.AMTCORPORATION.COM MAKE SURE TO VISIT OUR WEBSITE PERIODICALLY FOR INFORMATION ON NEW PRODUCTS AND TO DOWNLOAD ANY IMPORTANT PRODUCT DOCUMENTS THAT YOU MAY NEED IN THE FUTURE. Advanced Modern Technologies Corporation 19800 Nordhoff Place, Chatsworth, CA 91311 Tel: (818) 883-2682 Toll Free: (800) 874-7822 Fax: (818) 883-2620 www.amtcorporation.com REV. 07/17