BULLETIN 912-A. February 1999 HIGH PRESSURE BLOWER. Model HPB Direct Drive/Belt Driven

Similar documents
The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

& 12" 96" / TABD CATALOG

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS

UPBLAST AXIAL ROOF VENTILATORS

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

Turbo Pressure Blowers

TU-WAY ROOF VENTILATORS

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

CAST ALUMINUM PRESSURE BLOWERS

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

TURBO PRESSURE BLOWERS

Centrifugal Utility Fans - SFD/SFB

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

The Industrial Choice. TURBO PRESSURE BLOWERS. Models HPBA / HPBS

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PRESSURE BLOWERS MODEL PBW CATALOG 1260 APRIL 2015

Turning Air Into Solutions. PLUG FANS TYPE BCPL

Twin City Fan & Blower

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

Turning Air Into Solutions. CAST ALUMINUM PRESSURE BLOWERS MODEL TPD MODEL TPB

Twin City Fan & Blower

SURGE LIMITING PB FANS. Designed for high pressure, low flow applications with stringent job process requirements

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

Mixed Flow Inline Fan, Model MFSI

TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS. Model PBW

TUBULAR CENTRIFUGAL INLINE FANS

TURBO PRESSURE BLOWERS

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

Cast Aluminum Pressure Blowers

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Fixed Pitch Vane Axial Fan

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Twin City Fan & Blower

Air Moving Solutions. AIRFOIL fans

Twin City Fan & Blower

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

forward curved inline duct blowers

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

Defining Innovation. radial tip FaNS type Hrt BULLETIN 980 October 2009

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

FRP Fans: CLUB Series Performance and Technical Information

turbo pressure blowers

BACKWARD INCLINED BI AND BIA INDUSTRIAL SWSI CENTRIFUGAL FANS

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group

Inline and Roof Mounted Fans

TYPE HP. Static pressures to 128 WG Capacities to 20,000 CFM Temperatures to 600 F. PRESSURE BLOWERS Static pressures to 58 WG Capacities to 5,200 CFM

Defining Innovation. backward curved FANs

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

COMMERCIAL DUTY PLENUM FANS

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

VANEAXIAL & TUBEAXIAL FANS

Twin City Fan & Blower

The Industrial Choice. Model PB. Belt Driven. Model PB Direct Drive PRESSURE BLOWER. Model PB

FIXED PITCH PROPELLER FANS

MANCOOLERS. Macheta Airfoil Propeller Model UM / PUM / M39 / STL. Utility Mancooler Model UM. Pedestal Mount Mancooler Model PUM

FILTERED AIR SUPPLY FANS

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

TURNING AIR INTO SOLUTIONS. TURBO PRESSURE BLOWERS TBNA TBNS

Twin City Fan & Blower

Good Enough Never Is. Plug Fan SERIES 12

SECTION AXIAL HVAC FANS

Defining Innovation. INDUSTRIAL FANS TYPE RBO RBR RBA RBW RBP - CLASS 22 & 32

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

Square Inline Fans with Multi-Directional Discharge

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF CATALOG 950 AUGUST 2012

Tubular Centrifugal Fans

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories

The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS. Direct Drive & Belt Driven Model VJ / VJBD

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

AXIFAN VANEAXIAL FANS

HIGH VELOCITY FUME EXHAUST FANS

Twin City Fan & Blower

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

PEERLESS ELECTRIC INDUSTRIAL FANS

SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

SECTION CENTRIFUGAL HVAC FANS

Bulletin VX05 VANEAXIAL FANS

Industrial Mini Vent Sets

Air Moving Solutions. AEROFOIL fans

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

Transcription:

BULLETIN 912-A February 1999 HIGH PRESSURE BLOWER Model HPB Direct Drive/Belt Driven

Model HPB High Pressure Blowers Aerovent s High Pressure Blowers feature high static pressure capabilities from 11" to 69" and air volume to. High Pressure Blowers are durable, compact and versatile fans used in applications such as: Agitation and aeration Product cooling and drying Conveying Supplying combustion air to furnaces and ovens Exhausting Transporting solid materials Gas boosting and compressing Typical Pressure Blower Construction for Landfill Ventilation Abrasive and corrosion resistant coating on all airstream parts (for example, 3055 plasite baked phenolic). Thrust vanes on the back of the wheel to ensure negative pressure where the shaft penetrates the housing. AMCA B Spark Resistant Construction for the hazardous methane atmosphere. Stuffing Box Shaft Seal to obtain the best seal against gas leakage, although it does not make the unit completely gas tight. Available only in Arrangement 1 or Arrangement 8. Continuous double-welded scroll. Explosion Proof Motor (Class I, Group D, Division 1). Landfill Ventilation Aerovent commonly utilizes Model HPB High Pressure Blowers in landfill ventilation applications to extract methane gas. Methane emitted from decomposed waste in landfill sites can contaminate the surrounding property, through migration, if not properly contained. Typically, a gas collection system collects the methane generated by the waste and uses it to produce electricity for onsite equipment operation or for resale to local utilities. Recovered methane gas provides a clean source of fuel, improves air quality, and reduces greenhouse gas emissions. To extract methane gas from the landfill, perforated pipes (average 4" diameter) are sunk vertically down into the landfill and back filled with gravel. The pipes are manifolded together at the surface, and connected to the high pressure blower. Gas flows through the pressure blower and then to either a gas collection system or to a flare stack where it is burned off. Material Conveying High Pressure Blowers can also be utilized to convey material for industrial processes. An example would be polystyrene, or Styrofoam, for the manufacture of plastic grocery bags. Styrofoam is difficult to transport by hand because it is light and bulky. A high pressure blower is utilized to pneumatically convey this material from storage containers to the extrusion process for melting, molding and cooling. The polystyrene material is then melted on an extruder ring and air is blown through the ring to form a plastic tube. In many cases a separate high pressure blower is utilized to blow air through the ring. After the tube is formed, one end is heat sealed to complete the forming of the plastic bag. Contents Introduction......................... 2 Design Features.......................3 Drive Arrangements....................3 Accessories..........................4 How To Select A Pressure Blower..........6 Performance Data.....................7 Material Specifications For Standard Units....20 Dimensional Data.....................21 Typical Specifications..................25 1999 Aerovent Bulletin illustrations cover the general appearance of products at the time of publication and we reserve the right to make changes in design and construction at any time without notice. 2 Aerovent Bulletin 912

Design Features Construction A continuously-welded heavy-gauge steel housing and motor base provide for rugged, heavy-duty service. Rotatable and reversible housings are offered as a standard for all sizes. An inlet venturi with a guard is standard for all units. A flanged or pipe inlet is available as an option. The standard discharge is an all-welded heavy-duty flange drilled to match American Standard Class 125 bolt pattern. Wheel The Model HPB Blower is furnished with an aluminum alloy wheel, and is provided with a split-taper lock bushing for easy wheel removal from the shaft. Standard for wheel sizes 14" through 26" is riveted construction, while size 27" through 30" wheels are welded. Welded steel wheels are avail- able in all sizes for heat applications (temperatures 300 F to 0 F). For increased fan capacity, a wider wheel is offered for sizes 22" through 26". These fans are identified as W (wide) and the ratings are listed on pages 19 and 20. Heat Fans Arrangement 1 and 8 fans are available with optional construction for operation at temperatures up to 0 F. High temperature modifications include a welded steel wheel, special base construction to accommodate a heat slinger and guard, and aluminum paint finish. Fans requiring W (wide) wheels are not available with 0 F construction. Heat Slinger Drive Arrangements Arrangement 1 Arrangement 1 has a shaft and bearing assembly designed for the motor to be mounted in one of the four AMCA standard motor positions, W, X, Y or Z. Standard Unit Arrangement 4 Wheel is mounted directly to motor shaft, providing maximum performance at minimum cost and maintenance. Available for the full range of wheel sizes from 14" through 30". Maximum temperature is 180 F. Arr. 4 Drive Side Arrangement 8 Direct coupled unit with an extended pedestal to accommodate a motor and flexible coupling. Fan assembly can remain intact while removing motor for service. Available for the full range of wheel sizes from 14" through 30". Maximum temperature with aluminum wheel is 300 F. Arr. 8 neg Arr. 4 Inlet Side Arrangement 9 Built to Arrangement 1 specifications, but with an adjustable motor slide base and V-belt drive mounted on the fan pedestal. Motor located on right side as standard. Available throughout the range of sizes, and can be modified for operation at elevated temperatures. Pedestal dimensions limit selection to small motors only. Consult factory for availability of belt driven Arrangement 9 fans. Aerovent Bulletin 912 3

Accessories Shaft Seal Four types of friction shaft seals are available: 1. Elastomeric Rotary Seal Rides against a heavy Teflon wear plate. Spare seal provided as standard. Cut off old seal and push spare into place. This seal is suitable for operation up to 300 F. Available in Arr. 8 or in Belt Driven Fans Only 2. Ceramic Felt Elements are encased between housing drive side and metal retaining plate. Ceramic felt inserts may be easily split for field installation and maintenance. The seal is best suited for 301 F to 0 F operation. These seals minimize leakage around the shaft opening but are not gas-tight. 3. Lubricated Seals For longer seal life. Suitable to 300 F. 4. Stuffing Boxes Constructed of three rows of permanently lubricated packing material encased between the housing drive side and the machined metal packing gland. This shaft seal provides the best seal against gas leakage but is not totally gas-tight. Suitable for temperatures to 0 F. Specify temperature for proper packing material. Wheel Thrust Vanes Provide a simple solution to applications which require negative pressure at the point of shaft penetration of the scroll in order to prevent the escape of undesirable fumes or gases. Outlet Dampers Control airflow on discharge side of blower. Dampers have manual lever control. Recommended where a pipe is not connected to the discharge side of the blower. Standard damper is suitable for temperatures to 0 F. Inlet Filters (Weatherhood Shown) Permanent oil-wetted filters or throwaway cellulose filters are recommended where heavy dust conditions exist. An all-weather hood option is available. Pressure drop through clean filter, less hood, is 0.25" W.G. Specify flanged inlet for mounting. A combination filter/silencer is also available (see page 5). Flexible Sleeve Connects fan to standard piping and reduces noise and vibration transmission. Furnished with stainless steel hose clamps. Tube Adaptor Bolts to flanged inlet or discharge of fan. Provides connection to American Standard pipe sizes or a flexible sleeve (see above). 4 Aerovent Bulletin 912

Accessories Concentric Silencer The silencer is engineered and designed to effectively reduce objectionable air intake noise. SILENCER OCTAVE BAND INSERTION SIZE 1 2 3 4 5 6 7 8 LOSS 4 4 18 26 33 36 29 23 21 db 6 2 14 23 31 33 28 25 23 EACH 8 1 11 21 29 30 28 26 25 SILENCER 10 2 14 23 30 30 27 25 24 12 1 11 24 31 31 27 25 24 OPTIONAL FLANGED INLET OR OUTLET (SHOWN IN PHANTOM) OPTIONAL INLET ORIFICE RESISTANCE IN INCHES WATER GAUGE.20.15.10.05 0 1000 2000 3000 00 00 SILENCER INLET VELOCITY IN FPM Filter/Silencer An efficient intake filter with a silencing chamber enables the filter/silencer to meet both requirements. Weatherhood With Lift Handles 20 Filter Element ATTENTUATION (db) 15 10 5 0 0 63 125 2 0 1000 2000 00 8000 FREQUENCY (HZ) Number of Studs Aerovent Bulletin 912 5

How To Select A Pressure Blower To select a high pressure blower from the fan performance curves on pages 7 through 20, the system design and SP are needed (at standard density of 0.075 lb./ft 3 ). For high pressure blowers, it is recommended to select a motor 1 to 2 sizes larger than the performance curves suggest, as described in the following example: Example 1: Given a performance of 0 at 25" SP, select a size 19" High Pressure Blower with a 4" diameter outlet. The performance looks as follows (also shown on page 9 of this catalog): 0 at 25" SP, 3.91 BHP Static Pressure (Inches W.G.) With a 5% safety factor in static pressure, actual design may be 24" SP, which would require 5.38 BHP and a 7 1 2 HP motor. 26 25 24 23 5 HP 22 7 1 2 HP 300 0 0 0 700 The operating point of 0 and 25" SP is noted above by the diamond shape. Therefore, the performance point of 0 at 25" SP requires a 5 HP motor. NOTE: For a 5% or 1" reduction in design static pressure, the performance will require a 7 1 2 HP motor, as shown by the triangle shape. It is common in system design to put a 5 to 10% safety factor on the system static pressure. However, when utilizing this type of fan, it is important to consider its increasing brake horsepower characteristic. The performance curve for the Size 19", 4" outlet duct High Pressure Blower shown below depicts the increasing brake horsepower characteristic more clearly. For a small reduction in static pressure, the brake horsepower increases. Suction Pressure Corrections For Inlet Suction Conditions A suction pressure correction is necessary for inlet static pressures (usually 10" or greater). The static pressure is negative on the inlet or suction side of the fan so a partial vacuum is created at the fan inlet. This partial vacuum lowers the density of the air (or gas) or makes the air (or gas) rarefied. Therefore, the air must be converted to standard conditions by using the Suction Pressure Correction Factor, as shown in the example below. Example 2: Given a fan inlet static pressure of 20" at 70 F at sea level, the suction pressure correction ratio is calculated using the following formula: Ratio = Ambient Absolute Press. Fan Inlet SP Ambient Absolute Press. = 7 Fan Inlet SP 7 Ambient Absolute Press. = 7" For this example: Ratio = 7 20 = 0.99 7 Using this ratio, the static pressure at standard conditions is calculated as follows: SP @ Std. Cond. = 20" = 21.03" SP @ Std. Cond. 0.99 The static pressure of 21.03" is used for selecting the fan from the performance curves. 33 13.20 30 12.00 STATIC PRESSURE 27 24 21 18 15 12 9 SP @ 30 RPM 0, SP1 = 25" Decrease in SP BHP2 = 5.38 BHP1 = 3.91 SP2 = 24" SP Increase in BHP BHP @ 30 RPM 10.80 9. 8. 7.20 6.00 4.80 3. BRAKE HORSEPOWER 6 2. 3 1.20 0 4 8 12 16 20 IN 100s 6 Aerovent Bulletin 912

Performance Data The Aerovent Model HPB Blowers shown on pages 7 through 20 of this bulletin have been tested and rated in accordance with industry accepted test codes, and are guaranteed by Aerovent to deliver rated performance. Performances shown are based on 30 RPM motor speeds and standard inlet air density of 0.075 lbs./ft 3. Range of performance is within motor horsepower specified. Catalog Numbering System Wide Housing Nominal Fan Size (In.) Nominal Outlet Size (In.) Fan Type RPM Motor Horsepower W 26-12 - HPB - 30 - STATIC PRESSURE INCHES W.G. Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream Aerovent Bulletin 912 7

Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream 8 Aerovent Bulletin 912

Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream Aerovent Bulletin 912 9

Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream 10 Aerovent Bulletin 912

Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream Aerovent Bulletin 912 11

Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream 12 Aerovent Bulletin 912

Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream Aerovent Bulletin 912 13

Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream 14 Aerovent Bulletin 912

STATIC PRESSURE INCHES W.G. SIZE 27" 6" 27" Wheel Dia. 6" Outlet 30 RPM 38 36 34 15 hp 20 hp 25 hp 30 hp hp 32 30 0 0 1000 10 2000 20 3000 30 38 36 34 32 30 38 36 34 32 30 SIZE 27" 8" 27" Wheel Dia. 8" Outlet 30 RPM 15 hp 20 hp 25 hp 30 hp hp 0 0 1000 10 2000 20 3000 30 00 SIZE 27" 10" 27" Wheel Dia. 10" Outlet 30 RPM 15 hp 20 hp 25 hp 30 hp hp 0 0 1000 10 2000 20 3000 30 00 00 SIZE 27" 12" 27" Wheel Dia. 12" Outlet 30 RPM 15 hp 20 hp 25 hp 30 hp hp hp Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Aerovent Bulletin 912 15 hp hp hp 0 0 1000 10 2000 20 3000 30 00 00 hp

SIZE 28" 6" 28" Wheel Dia. 6" Outlet 30 RPM 38 36 34 15 hp 20 hp 25 hp 30 hp hp hp 32 30 0 0 1000 10 2000 20 3000 30 00 STATIC PRESSURE INCHES W.G. 62 38 36 34 32 30 SIZE 28" 8" 28" Wheel Dia. 8" Outlet 30 RPM 15 hp 20 hp 25 hp 30 hp hp hp hp 0 0 1000 10 2000 20 3000 30 00 00 SIZE 28" 10" 28" Wheel Dia. 10" Outlet 30 RPM 62 38 36 34 15 hp 20 hp 25 hp 30 hp hp hp hp 75 hp 32 30 0 0 1000 10 2000 20 3000 30 00 00 SIZE 28" 12" 28" Wheel Dia. 12" Outlet 30 RPM 75 hp 38 36 15 hp 20 hp 25 hp 30 hp hp hp hp 34 32 0 0 1000 10 2000 20 3000 30 00 00 Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. 16 Aerovent Bulletin 912

SIZE 29" 6" 29" Wheel Dia. 6" Outlet 30 RPM 66 64 62 38 36 34 32 20 hp 25 hp 30 hp hp hp hp 30 28 0 0 1000 10 2000 20 3000 30 00 STATIC PRESSURE INCHES W.G. 66 64 62 38 36 SIZE 29" 8" 29" Wheel Dia. 8" Outlet 30 RPM 34 0 0 1000 10 2000 20 3000 30 00 00 66 64 62 38 36 20 hp 25 hp 30 hp hp hp hp 75 hp SIZE 29" 10" 29" Wheel Dia. 10" Outlet 30 RPM 20 hp 25 hp 30 hp hp hp hp 75 hp 34 0 0 1000 10 2000 20 3000 30 00 00 50 66 64 62 38 36 SIZE 29" 12" 29" Wheel Dia. 12" Outlet 30 RPM 20 hp 25 hp 30 hp hp hp hp 75 hp 34 0 0 1000 10 2000 20 3000 30 00 00 50 Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Aerovent Bulletin 912 17

70 68 66 64 62 38 36 SIZE 30" 6" 30" Wheel Dia. 6" Outlet 30 RPM 20 hp 25 hp 30 hp hp hp hp 0 0 1000 10 2000 20 3000 30 00 STATIC PRESSURE INCHES W.G. SIZE 30" 8" 30" Wheel Dia. 8" Outlet 30 RPM 70 68 66 64 62 20 hp 25 hp 30 hp hp hp hp 75 hp 0 0 1000 10 2000 20 3000 30 00 0 SIZE 30" 10" 30" Wheel Dia. 10" Outlet 30 RPM 70 68 66 64 62 25 hp 30 hp hp hp hp 75 hp 0 0 1000 10 2000 20 3000 30 00 00 70 68 66 64 62 SIZE 30" 12" 30" Wheel Dia. 12" Outlet 30 RPM 25 hp 30 hp hp hp hp 75 hp 0 0 1000 10 2000 20 3000 30 00 00 Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. 18 Aerovent Bulletin 912

STATIC PRESSURE INCHES W.G. Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Aerovent Bulletin 912 19

STATIC PRESSURE INCHES W.G. Performance shown is for installation Type D: Ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Material Specifications for Standard Units SIZE SIDE PLATES HOUSING MOTOR BASE ALUMINUM WHEEL STEEL WHEEL SCROLL FRAME BASE MIN. WEIGHT WR 2 WEIGHT WR 2 BACK & REINFORCE- PLATE REINFORCE- MOTOR (LB) (LB-FT 2 ) (LB) (LB-FT 2 ) SIDES MENT MENT HP* 14" 8.4 1.4 25.2 4.2 1 1 2 15" 8.9 1.7 26.7 5.1 3 16" 0.13" 0.135" 0.25" x 2" 0.2" 0.25" x 2" 9.4 2.1 28.2 6.3 3 17" 10.5 2.6 31.5 7.8 5 18" 11.6 3.2 34.8 9.6 5 19" 11.6 3.1 34.8 9.3 5 21" 0.13" 0.135" 0.25" x 2" 0.2" 0.25" x 2" 13.5 4.6.5 13.8 7 1 2 22" 14.4 5.5 43.2 16.5 10 23" 14.0 6.0.0 18.0 10 24" 15.2 6.9 45.6 20.7 10 0.1875" 0.135" 0.25" x 2" 0.2" 0.25" x 2" 25" 16.2 8.0.6 24.0 10 26" 17.8 9.2 53.4 27.6 10 27" 34.6 18.5 104 55.6 25 28" 36.6 21.1 110 63.3 30 0.1875" 0.135" 0.25" x 2" 0.2" 0.25" x 2" 29" 38.6 23.8 116 71.6 30 30".6 26.8 122 80.4 W21" 16.5 4.9 49.5 14.7 7 1 2 W22" 17.6 5.7.8 17.1 10 W23" 18.0 6.8.0 20.4 10 0.1875" 0.135" 0.25" x 2" 0.2" 0.25" x 2" W24" 19.6 7.8.8 23.4 10 W25" 21.4 9.1 64.2 27.3 10 W26" 22.4 10.3 67.2 30.9 15 *To overcome inertia of steel wheel. 20 Aerovent Bulletin 912

Dimensional Data Arrangement 1 C B F G 9/16 DIA. HOLES (4) REQ'D. T U T U E D A K M S R N J H L (I.D.) HSG. WHL SHFT OUT. FLNGE A SIZE SIZE DIA SIZE B C D E F G H J K L M N R S T U 14" 15" 4" 18" 16" 1 1 2 18 3 /8 6" 17 1 4 12 7 /16 10 9 /16 10 13 /16 13 3 /16 11 11 /16 23 3 4 7 1 2 3 1 2 6 5 8 6 1 4 17 1 4 4 1 4 12 8 3 4 9 5 8 17" 8" 18" 22" 4" 19" 6" 17 3 21" 1 1 2 24 3 /4 /8 8" 22" 10" 21 3 /4 16 5 8 14 3 /4 14 1 2 17 5 8 15 5 8 23 3 /4 6 1 2 4 6 5 8 6 1 4 17 1 4 4 3 8 12 11 11 7 8 26" 23" 24" 6" 8" 19 25" 1 1 2 26 7 /8 10" 26" 12" 23 18 11 /16 16 11 /16 16 7 /16 19 13 /16 17 9 /16 23 1 2 6 1 2 5 8 5 3 4 17 4 1 /32 12 12 3 8 13 1 4 27" 6" 26 1 2 28" 8" 30" 2 3 /16 30 22 5 8 19 13 /16 17 5 8 25 1 8 20 1 8 29 15 /16 6 1 2 6 8 5 3 4 21 1 /16 4 1 /16 16 13 3 8 14 1 4 29" 10" 30" 12" 28 1 2 W26" W21" W22" W23" W24" 1 15 16 26 7 /8 12" 27 18 11 16 16 11 16 16 7 16 19 13 16 17 9 16 25 3 8 7 7 16 6 8 7 5 8 17 15 16 4 31 32 12 12 3 8 13 1 4 W25" W26" Aerovent Bulletin 912 21

Dimensional Data Arrangement 4 C B 9 /16" Dia. Holes F G E D A N H M J L (I.D.) Std. Inlet Venturi U U T T S BASE DETAIL NOTES: Flanged discharge is standard. Optional inlet flanges are available in any combination shown on page 24. Inlet flanges smaller than inlet venturi will require an optional pipe inlet (performance will be affected). Inlet flange will match discharge flange where possible, if not otherwise specified. All flanges match American Standard Class 125 drilling. R All dimensions in inches. *CONSULT FACTORY FOR DOWNBLAST DISCHARGE DIMENSIONS. HOUSING WHEEL OUTLET SIZE SIZE SIZE B C D E F G J L M N R S T U 14" 4", 6" 15" 4" 18" 16" 17 1 4 12 7 16 10 9 16 10 13 16 13 3 16 11 11 16 6 1 2 6 5 8 6 1 4 18 1 2 4 1 4 13 1 4 8 5 8 9 1 2 6" 17" 8" 18" 19" 4" 6" 17 3 4 22" 21" 8" 16 5 8 14 3 4 14 1 2 17 5 8 15 5 8 6 1 2 6 5 8 6 1 4 20 5 8 4 3 8 15 1 4 11 11 7 8 22" 10" 21 3 4 26" 23" 6" 24" 8" 19 25" 10" 26" 12" 23 18 11 16 16 11 16 16 7 16 19 13 16 17 9 16 6 1 2 8 5 3 4 24 5 16 4 7 8 18 1 2 12 3 8 13 1 4 30" 27" 6" 28" 8" 26 1 2 29" 10" 30" 12" 28 1 2 22 5 8 19 13 16 17 5 8 25 1 8 20 1 8 6 1 2 8 5 3 4 24 5 16 4 7 8 18 1 2 13 3 8 14 1 4 W21" W22" W26" W23" W24" 12" 27 18 11 16 16 11 16 16 7 16 19 13 16 17 9 16 7 7 16 8 7 5 8 25 1 4 5 13 16 18 1 2 12 3 8 13 1 4 W25" W26" HOUSING SIZE 18" MOTOR FRAME 143T & 145T 16 5 8 182T & 184T 17 5 8 213T 215T 18 3 8 143T & 145T 21 5 8 182T & 184T 22 5 8 H A OPEN ENCLOSED MOTOR MOTOR 25 25 22" 213T & 215T 23 3 8 27 1 8 27 1 8 2T 2T 24 3 8 182T & 184T 25 1 8 213T & 215T 25 7 8 2T & 2T 26 7 8 26" 284TS 30 13 16 30 13 16 27 5 8 286TS 324TS 326TS 28 5 8 HOUSING SIZE 30" MOTOR FRAME 2T & 2T 29 7 8 284TS & 286TS 30 5 8 324TS & 326TS 31 5 8 364TS & 365TS 32 5 8 213T & 215T 25 7 8 2T & 2T 26 7 8 284TS 286TS 27 5 8 H A OPEN ENCLOSED MOTOR MOTOR 30 13 16 30 13 16 W26" 324TS 32 11 16 32 11 16 28 5 8 326TS 364TS 29 5 8 365TS 22 Aerovent Bulletin 912

Dimensional Data Arrangement 8 C B F G D A L (I.D.) E 9/16 DIA. HOLES (6) REQ'D. T U T U 1 S N S R M J H HSG WHL SHFT OUT. FLNGE A SIZE SIZE DIA SIZE B C D E F G J L M R T U 14" 15" 4" 18" 16" 1 1 2 18 3 /8 6" 17 1 4 12 7 /16 10 9 /16 10 13 /16 13 3 /16 11 11 16 6 1 2 6 5 8 6 1 4 4 1 4 8 3 4 9 5 8 17" 8" 18" 22" 4" 19" 6" 17 3 21" 1 1 2 24 3 /4 /8 8" 22" 10" 21 3 /4 16 5 8 14 3 /4 14 1 2 17 5 8 15 5 8 6 1 2 6 5 8 6 1 4 4 3 8 11 11 7 8 26" 23" 6" 19 24" 8" 1 1 2 26 7 /8 25" 10" 23 26" 12" 18 11 /16 16 11 /16 16 7 /16 19 13 /16 17 9 /16 6 1 2 8 5 3 4 4 1 /32 12 3 8 13 1 4 30" 27" 6" 26 1 2 28" 8" 2 3 /16 30 29" 10" 28 1 2 30" 12" 22 5 8 19 13 /16 17 5 8 25 1 8 20 1 8 6 1 2 8 5 3 4 4 1 /16 13 3 8 14 1 4 W21" W22" W26" W23" W24" 1 15 16 26 7 /8 12" 27 18 11 16 16 11 16 16 7 16 19 13 16 17 9 16 7 7 16 8 7 5 8 4 31 32 12 3 8 13 1 4 W25" W26" Aerovent Bulletin 912 23

Flange Dimensions O.D. B.C. Pipe Size 1 3 /8" 1 1 /8" J ± 1 /4" FLANGED INLET (OPTIONAL) J PIPE INLET (OPTIONAL) FLANGE DIMENSIONS INLET/DISCHARGE BOLT HOLES I.D. O.D. SIZE CIRCLE NO. SIZE 4" 4 9 7 1 2 8 3 4 6" 6 11 9 1 2 8 7 8 8" 8 13 1 2 11 3 4 8 7 8 10" 10 16 14 1 4 12 1 12" 12 19 17 12 1 Standard Pipe Sizes Offered: 6 5 8" O.D. on 18" and 22" housings 8 5 8" O.D. on 26", 30" and W26" housings. Others sizes available upon request. Discharge Arrangements DISCHARGE POSITION TOP HORIZONTAL BOTTOM HORIZONTAL UPBLAST TOP 45 DOWN BOTTOM 45* UP TOP 45 UP ROTATION CLOCK- WISE * COUNTER CLOCK- WISE * SPECIAL CONSTRUCTION IS REQUIRED FOR CLOCKWISE AND COUNTERCLOCKWISE DOWNBLAST POSITIONS. * 24 Aerovent Bulletin 912

Typical Specifications Fans shall be Model HPB High Pressure Centrifugal Blowers as manufactured by Aerovent, Minneapolis, Minnesota, and shall be of the size and capacity as indicated in the fan schedule. Model HPB High Pressure Blowers shall be tested and certified in accordance with ANSI/ASHRAE 51-1985 and ANSI/AMCA 210-85 test codes and guaranteed by the manufacturer to deliver the rated, published performance levels. In addition, each unit shall be factory test run prior to shipment. CONSTRUCTION The Model HPB High Pressure Blower shall have a continuously welded heavy-gauge steel housing and motor base for rugged, heavy duty service. All sizes shall have rotatable and reversible housing, inlet venturi with a guard, and all-welded heavy duty flanged discharge drilled to match American Standard Class #125 bolt pattern. A flanged or piped inlet is available as an option. WHEEL The Model HPB High Pressure Blower shall be furnished with an aluminum alloy wheel. Wheel sizes 14" through 26" shall be a riveted construction, while wheel sizes 27" to 30" shall be welded. The wheel shall be dynamically and statically balanced and shall be attached to the shaft with a split-taper lock bushing for easy removal from the shaft. Welded steel wheels are available for heat applications (temperatures 300 F to 0 F). BEARINGS (Arr. 1, 8 only) Bearings shall be of a regreasable pillow block type, and shall have a minimum L- 10 life as defined by AFBMA of at least 20,000 hours (100,000 hours average life). DRIVES (Arr. 1, 8 only) Belts and sheaves furnished by the manufacturer shall be designed with a 1.4 service factor unless otherwise specified. Sheaves shall be cast iron with static conducting belts. The adjustment of the belt tension is accomplished with an adjustable motor base. MOTORS Motors shall be foot-mounted NEMA Design B, standard industrial, continuous duty, ball bearing, variable torque type suitable for operation on voltage, phase, and hertz, as listed in the fan schedule. Motor bearings shall have a minimum L-10 life, as defined by AFBMA, of at least,000 hours (200,000 hours average life). BALANCING The wheel assembly shall be statically and dynamically balanced in accordance with ANSI/AMCA 204-96 Balance Quality and Vibration Levels for Fans to Fan Application Category BV-3, Balance Quality Grade G6.3. In addition, direct drive fan wheels shall be balanced on the motor shaft, belt driven fan wheels shall be balanced on the fan shaft after final assembly in the fan casing, in the manufacturing facility, to the following peak velocity values, filter-in, at the fan test speed: Fan Application Category Rigidly Mounted (in./s) Flexibly Mounted (in./s) BV-3 0.15 0.20 FINISH The unit, after fabrication, shall be cleaned and chemically pretreated by a phosphatizing process and shall be painted inside and outside with an air dry enamel. The fan shall be coated with the following optional finish: Plasite 4310 Vinyl Ester Plasite 7122L/Heresite VR6 Epoxy Phenolic Plasite 3066 Baked Phenolic Farboil Baked Aromatic Epoxy Air Dried Epoxy Carbocoat 30 (replaces Carbolene 33/Sanitile 5) SOUND POWER LEVELS The sound power level of the fans shall not exceed: Octave Band - CPS (Sound Power 10-12 ) 20-75 75-1 1-300 300-0 0-1200 1200-20 20-00 00-10000 ACCESSORIES The units shall be furnished complete with: Spark Resistant Construction (Type A or B) Outlet Dampers Shaft & Bearing Guard Continuous Double-Welded Scroll Belt Guard Inlet Filter Coupling Guard Inlet Combination Filter/Silencer Inlet Flange Inlet/Outlet Silencer Tube Adapter (Inlet/Outlet) Outlet Silencer Flexible Connector (Inlet/Outlet) High Temperature Welded Steel Wheel Wheel Thrust Vanes Unitary Base Shaft Seal (Elastometric Rotary, Ceramic Felt, Vibration Isolators (Spring or R.I.S.) Lubricated, or Stuffing Box) Aerovent Bulletin 912 25