Read and understand this manual for safely usage.

Similar documents
Read and understand this manual for safely usage.

Read and understand this manual for safely usage.

TS02 0199 I N S T R U C T I O N M A N U A L F O R ROTATING PADDLE LEVEL SENSOR MODEL R B 2 0 R B 2 1 Revision

OIL LEAK DETECTOR. Issued

MAGNETOSTRICTIVE LEVEL MEASUREMENT

Differential Pressure Transmitter

Free Float Air Trap G8

Operation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves

AUTOMATION. Operator s Manual. NLS Series. Pneumatic Level Sensors. Rev. A1, 4/07

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

INSTRUCTION MANUAL MANOSTAR TRANSMITTER EMT1. RoHS READ THE INSTRUCTION MANUAL BEFORE USING. No. TR-EMT1-E08

INSTRUCTION GREASE PUMP. PD110A50T MODEL No PD110A50T-SL MODEL No PD110A50 MODEL No DR110A50 MODEL No.

Manufacturer Kakogawa, Japan DC5S

Lumitester PD-20 Control Kit

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

INSTRUCTION OIL PUMP. SH-110A5 MODEL No DR-110A5 MODEL No PD-110A5 MODEL No WARNING

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

Technical information for LFU20-Z07-3A-X2

TOWA SEIDEN INDUSTRIAL CO., LTD.

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

Operating instructions

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

D Instructions/Parts. Siphon Feed Detail Spray Gun D

MR 5-30 Aviation Fuel Meter Owner s Manual

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8

Pressure Sensor/PS-A (ADP5)

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

SUPER TYPE PILLAR FITTING INSTRUCTION MANUAL

Operators Manual. Recirculating Chiller /06/08

6L Oil-less Air Compressor 53103

Pressure Transmitter

EVS RP6020. Instruction Manual

3M TM Filter Housing 1BS-T/1BS-TW Series

Matala. VersiFlow Series. Instruction and Maintenance Manual

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

Hydraulic PTO Flow Device

INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B

Diaphragm Valve Type 72

EEMB CO., LTD. Lithium Thionyl Chloride Battery Specification. High Power Type. Prepared Checked Approved. Signature Checked Approved

3-Way Ball Valve Type 23H

Duplex Booster System Instruction Manual

INSTRUCTIONS FOR USE. Rx Only


Hydraulic Immediate Need Power Pack

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Diaphragm Valves Type 15

Injector. General Information CAUTION. Use only the specified injector for the engine.

Pressure sensor with built-in amplification and temperature compensation circuit

EEMB CO., LTD. Specification

BATTERY & STARTER ANALYSER (BSA-12) User Manual

T1-Titanium Non-HVLP Spray Gun

RP Instruction Manual

Installation and Operating Instructions. Solar System Controller ISC3020

INSTRUCTION ELECTRIC GREASE LUBRICATOR. ( AC-100V 50/60Hz ) EPL-100 MODEL No WARNING

Constant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual

CAUTION. Disconnect Power

INSTALLATION & MAINTENANCE MODEL mm

EEMB CO., LTD. Specification

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

BEFORE USING THE PRODUCT

HDI inch Choke Position Indicator User s Manual Rev Indicator Gauge Linear Potentiometer

Before installing your Roush Performance Product(s), read through the entire installation procedure and check to make sure all items are present.

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1

Air Operated Valve Control Valve

ACTIVAL Two-way Ball Valve with Threaded-end Connection

OPERATION MANUAL. Diaphragm Pump. TD/TD2 Series TD-08, 15, 20/TD2-25. Introduction

Vacuum Switch with LED display

Butterfly Valve Type 57P

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

Introduction. Tool units covered by this Instruction manual NX020T2-07M1-20 NX050T2-07M1-20 NX100T2-07M1-20

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use

Solar Charge Controller Owner s Manual SC 1210 SC 1210LD SC 1220LD

LITHIUM-ION POLYMER RECHARGEABLE BATTERY

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM

EWT Li-Ion Battery Datasheet

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 11 CALIBRATING INSTRUMENTS

3/12/2012 UNIT OBJECTIVES THE NEED FOR CALIBRATION SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 11 CALIBRATING INSTRUMENTS

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

LM-200 MECHANICAL LUBE METER Owner s Manual

User s Manual. Pipette Controller for liquid handling. Thank you very much for purchasing Pipette Mate NEO.

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

GeyserMax-Flow Series

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

EEMB CO., LTD. Specification

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)

Mounting Instruction for Fuji Automotive IGBT Module M653 Series 6MBI800XV-075V-01 Mounting Instruction. March 2018 Rev.0.0

PIERBURG. Carburetor: 2E3

Model No. SP Low Volume Low Pressure (LVLP) Gravity Feed Spray Gun

LS0512 Solar Charge Controller

Multi-Spray Unit Air-Assisted Airless Spray Unit MSU-111N (13:1 Stand Mount) MSU-113N (13:1 Cart Mount) MSU-114N (13:1 Wall Mount)

Butterfly Valve Type 58 (PDCPD)

Transcription:

TS02-0180 INSTRUCTION MANUAL FOR AIR BUBBLER SYSTEM LEVEL MEASUREMENT MODEL:LA100 MODEL:LA110 MODEL:LA1000

Read and understand this manual for safely usage. This manual describes the product of standard specification. Read the other manual for the product of explosion-proof specification. This manual describes the handling, inspection and adjustment of the product which model is mentioned on cover page. Read and understand this manual before handling. Follow the additional document and/or direction, submitted by NOHKEN INC. and our distributor or agent, even if the terms are mentioned in this manual. Save this manual in proper place being available to refer immediately. The specification of product mentioned in this manual may not be satisfied by the condition of environment and usage. Check and consider carefully before using. Contact to sales office at NOHKEN INC. for any question or comment about this manual and product. The followings are the description of the terms in this manual. Indicates a potentially hazardous situation which, if not pay WARNING attention, could result in death, serious injury or serious disaster. CAUTION Indicates a hazardous situation which, if not pay attention, may result in minor or moderate injury or damage to device. Indicates prohibited matter. The explanation with this mark shallbe followed Indicates instructed matter. The explanation with this mark shallbe followed. -ADD 1 -

WARNING This product is not explosion-proof construction. Do not install this product to the place where the flammable gas or vapor is occurred. If installed, the flammable gas or vapor may be ignited, and serious disaster may be occurred. Use the product of explosion-proof construction in this case. Do not modify or disassemble the product. Otherwise, the product and connected device may be malfunctioned, damaged, fired, or miner injury and electric shock may be occurred. (Follow the additional document and/or direction, submitted by NOHKEN INC. and our distributor or agent.) Turn off the power, before wiring and inspection. Otherwise, electric leakage, fire caused by short circuit, and electric shock may be occurred. Ensure the wire is properly connected. The product and connected device may be malfunctioned, damaged, fired, or miner injury and electric shock may be occurred by improper wiring. Turn off the power immediately, if the smoke, strange smell and sound are occurred. Do not use it until the problem is solved. CAUTION Avoid shock and rough handling to this product. The product may be damaged by shock as dropping, falling, throwing, knocking, lugging, and etc. Follow the specification of operating temperature, operating pressure, switch rating, and etc. Otherwise, the product and connected device may be malfunctioned, damaged, fired, or miner injury and electric shock may be occurred. Check the manual or specification sheet. Operation test shall be done before practical usage. If the serious accident is expected to occur by malfunction of product, the other operating principle of product shall be installed in parallel. -ADD 2 -

CAUTION Check and deeply consider the chemical compatibility for material of product in advance. Hold the stem very close to mounting point, when carrying, installing, and removing. If hold the terminal box, it may be taken off from the flange or plug, and the product may be damaged by dropping. The product is 50cm or longer The product shall be kept in horizontally. The product and other goods be damaged, and miner injury may be occurred by falling. Provide arrester or surge absorber to avoid electrical impact such as lightning and static electricity. If not provide, the product and connected device May be malfunctioned, damaged, and fired, or miner injury and electric shock may be occurred. -ADD 3 -

INTRODUCTION A) This manual specifies the specification of general product. If you order special product, some details of specification may be different with the manual. B) We are glad to suggest and advice for Model selection and chemical resistant of material, but final decision has to be made by the customer. C) This manual has prepared with close attention. Ask sales office at NOHKEN INC. for any question or comment about the contents of this manual. D) For replacement parts The quality of product has frequently improved, so same spare part may not be supplied. In this case, replacement part or product may be supplied. Ask sales office at NOHKEN INC. for details. E) The contents of this manual are subject to change any time without notice due to the improvement of product. WARRANTY & DISCLAIMER A) NOHKEN INC. warrants this product against defect in design, material and workmanship for a period of 1(one) year from the date of original factory shipment. B) The warranty only covers the damage of products. The secondary and third kind disasters are not covered by NOHKEN INC. C) NOHKEN INC. shall not be liable for the following. C-a) Do not follow the description and direction in this manual. C-b) Damage due to improper installation, wiring, usage, maintenance, inspection, storing, and etc. C-c) Repair and modification are done by the person who is not employee of NOHKEN INC. and our distributor or agent. C-d) Improper parts are used and replaced. C-e) The damage is occurred by the device or machine except our products. C-f) Improper usage. (See "Proper of usage" in chapter 1 in this manual) C-g) Force Majeure including, but not limited to, fire, earthquake, tsunami, lightning, riots, revolution, war, radioactive pollution, acts of God, acts of government or governmental authorities, compliance with law, regulation, and order. THE TERMS OF WARRANTY AND DISCLAIMER SHALL IN NO WAY LIMIT YOUR REGAL LIGHT. -ADD 4 -

TABLE OF CONTENTS Page No. 1. PURPOSE OF USE 1 2. SPECIFICATION 1 2.1 Standard Specifications 1 2.2 Dimensions 2 3.PRINCIPLE OF OPERATION 3 4. INSTALLATION 4 4.1 Unpacking 4 4.2 Installation Location 4 4.3 Installation of Sensor 4 4.4 Installation of Converter 4 5. PIPING AND WIRING 5 Page No. 6. ADJUSTMENT 6 6.1 Start-up 6 6.2 Component Names 6 6.3 Air Source Adjustment 7 6.4 Offset and Gain Adjustment 7 6.5 Output Signal Adjustment 7 7. TECHNICAL NOTES 8 8. INSPECTION / MAINTENANCE 8 8.1 Sensor 8 8.2 Converter 8 9.TROUBLESHOOTING 9

1. PURPOSE OF USE The Air Bubbler System Level Measurement is designed to measure for corrosive liquid or high viscosity liquid such as waste water. This unit receives back pressure of liquid from the sensor, converts it into an electrical signal and outputs 4 to 20 ma DC. Also this unit visually indicates liquid level due to having a indicator. 2. SPECIFICATIONS 2.1 Standard Specification (1) Sensor Table 1 Model LA100 (Flexible type) LA110 (Pipe type) Measuring object Liquid Process connection 1 Flange mounting Flange mounting JIS 10K 100A or equivalent (Proviso 4 holes) JIS 5K 25A Piping Hose nipple for φ8 Ring joint for φ6 Dimension See Fig. 1 See Fig. 2 Material Flange PVC 304 Stainless steel 1 Detector PVC tube 304 Stainless steel pipe Anchor weight 304 Stainless steel --- 1 Other materials or other process connection available. (2) Converter Model : LA1000 Measuring range : 0 to 10 m Accuracy : ±0.5 % of span Temp. characteristics : ±0.05 % of span Power supply : 24 V ±2 V DC Power consumption : Approx. 1 W Output signal : 4 to 20 ma DC Load resistance : 800 Ω Max. Amplification : 1 to 5 times Working temperature : 0 to 50 Power pressure supply : 200 to 300 kpa Air source to sensor : 0.3 to 1 l/minute variable Overpressure of sensing : 300 kpa Max. element Material of casing : CS plate hose nipple : Brass Mounting : Wall mounting (Pitch W155 H190 4 φ6.5 holes) Construction : IP23(Rain proof) Mass : Approx. 5.5 kg - 1 -

2.2 Dimensions Fig. 1 LA100 Sensor Fig. 2 LA110 Sensor Fig. 3 LA1000 Converter - 2 -

3. PRINCIPLE OF OPERATION The Level Measurement contains the pressure element. The pressure element measures the differential pressure between the back pressure equivalent the depth of water and atmospheric pressure. Built-in purge set consists of needle valve and constant differential valve, supplies constant air to sensor. The converter measures back pressure from sensor with pressure element due to spouting this air source through the sensor into liquid, converts it into an electrical signal (4 to 20 ma DC). Indicator Pressure element Amplifier Output signal 4 to 20 ma DC Power supply 24 V ±2 V DC Purge set Power pressure supply 200 to 300 kpa Fig. 4 Principle of operation - 3 -

4. INSTALLATION 4.1 Unpacking This Level Measurement have been thoroughly inspected and carefully packed at the factory to prevent from damage during shipment. When unpacking, exercise due care not to subject the instrument to mechanical shock. After unpacking, visually check the instrument exterior for damage. 4.2 Installation Location This Level Measurement should be installed in an area where the following condition. (1) Provide ample space for maintenance / inspection. (2) Low relative humidity and no exposure to moisture. (3) No corrosive gases. (Such as NH 3, SO 2, Cl 2 etc) (4) No excessive vibration. 4.3 Installation of Sensor Model LA110 NOTE ; When the liquid level falls below bubble outlet the sensor, the out put current will remain at 4 ma DC nominal. Fig. 5 Example of sensor installation CAUTION Do not bend or clog the sensor. Otherwise sensor operation may be incorrect or damaged. 4.4 Installation of Converter Install the converter on a wall. Fig. 6 shows mounting pitch of the converter. NOTE ; Install the converter as cable inlet position is toward ground to protect from rain or splashing water. Fig. 6 Mounting pitch - 4 -

5. PIPING AND WIRING Fig. 7 Piping LA1000 TERMINAL Short bar Output GND + - LOAD RESISTANCE 800 Ω Max. LOAD + Output - POWER SUPPLY 24 V ±2 V DC Fig. 8 Wiring CAUTION Short bar is installed on output terminals because of connected with indicator and output terminals in series. The load should be connected with converter after removed the short bar. NOTE the following points: (1) This converter unit is designed to operate with load resistance 800 ΩMax. (2) Cable inlet are made G3/4 or equivalent. The cable finished outside diameter should be used between 11 to 12 mm. (3) Install solderless lugs fitted to M3 screw to the end of lead wires. Recommended lugs R1.25-3 or R1.25-3.5. - 5 -

6. ADJUSTMENT 6.1 Start-up Proceed as follows: (1) Make sure that there are no miswiring. CAUTION Supply voltage must match the terminals indicated on the terminal block. Incorrect voltage miswiring will damage the converter. (2) The sensor and the converter have been adjusted before shipment. If it need fine adjustment or if specification is changed, adjust output signal in accordance with adjustment procedure described blow. NOTE; When adjustment, the sensor should be connected to power supply and allowed to stabilize for one hour in air. 6.2 Component Names 1 Terminals 2 Indicator For output current(4 to 20 ma DC)of zero position. 4 SPAN adjusting volume For output current (4 to 20 ma DC) of span position. 5 GAIN adjusting volume Correcting for input signal of span position. (0 to 2 V DC) 6 OFFSET adjusting volume Correcting for input signal of zero position. (0 to 2 V DC) 7 CHECK point Using at adjustment for OFFSET and GAIN. 8 Flow gauge Fig. 9 Operational panel 9 Pipe fitting for AIR OUT" 10 Pipe fitting for DETECT" 11 Pipe fitting for AIR IN Fig. 9 Operational panel 12 Needle valve 13 Vent pipe - 6 -

6.3 Air Source Adjustment Set 0.5 l/minute the air source with needle valve looking for flow gage. NOTE; When measuring liquid is high viscosity, set 0.8 l/minute the air source with needle valve. 6.4 Offset and Gain Adjustment (1) Connect digital voltmeter (measuring range ; 0 to 2 V DC) to the check point terminals on operational panel. NOTE; The red colored terminal is positive, the black colored terminal is negative. (2) When the liquid level is zero, adjust 0 V DC between the check point terminals with OFFSET volume. (When turning a volume to the right, the voltage rises.) NOTE; If the tank is already filled with liquid, lift up the sensor and adjust that above. (4) When the liquid level is span, adjust 2 V DC between the check point terminals with GAIN volume. (When turning a volume to the left, the voltage rises.) NOTE; If the tank is not filled up with liquid, measure the liquid level and adjust calculated value according to expression of 1. 6.5 Output Signal Adjustment (1) Connect digital ammeter (measuring range ; 4 to 20 ma DC) to output terminals reference with Fig. 8. (2) When the liquid level is zero, adjust 4 ma DC with ZERO volume. (When turning a volume to the right, the indication and the output rises.) NOTE; If the tank is already filled with liquid, lift up the sensor and adjust that above. (3) When the liquid level is span, adjust 20 ma DC with SPAN volume. (When turning a volume to the right,the indication and the output rises.) NOTE; If the tank is not filled up with liquid, measure the liquid level and adjust calculated value according to expression of 2 For example M=8m[Measuring range] A=6m[Measured length] A/M 2=6/8 2=1.5(V)[GAIN] 1 A/M 16+4=6/8 16+4=16(mA)[SPAN] 2 Fig. 10-7 -

7.TECHNICAL NOTES (1) Do not install the sensor near inlet or outlet of liquid. (2) Keep the sensor to protect away from mechanical shocks during carrying or installation. (3) When the liquid level falls below bubble outlet of the sensor, the output current will remain at 4 ma DC nominal. (4) After installation, provide the products to protect from rain or splashing water until completion the wiring and piping. 8. INSPECTION/MAINTENANCE The following annual servicing tasks should be carried out on the sensor and control unit. 8.1 Sensor a. Visually check the sensor exterior for damage. b. Make sure that there are no leak from piping connection with as soapy water. 8.2 Converter a. Make sure that output current is 4 ma DC, when sensor is lifted up. b. Make sure that output current is correct equivalent to calculated value with expression of 2, when the sensor is installed. NOTE; If out put signal is incorrect, re-adjust the control unit in accordance with 6. ADJUSTMENT ". - 8 -

9. TROUBLESHOOTING CAUTION Use the following chart to troubleshoot the malfunctioning sensor. If your remedies are unsuccessful, ask Nohken for repair and replacement. Problems Causes Remedies No output current. There are broken of wire. Replace the wire. Loosening terminals Tighten terminals. Indication(graduator) is correct, but no output. Short bar is installed. Remove the short bar on output terminals reference with 5 WIRING". Output current does not follow with level falling or rising. Installation on improper level. Re-install in proper level. Supplied air is little. Re-set air source according to 6.3 Air source Adjustment. Air leakage. Check air leak on part of piping connection. Improper adjustment. Adjust correctly according to 6 ADJUSTMENT". Change of liquid S.G. Sensor (detection pipe) is stopped up. Re-adjust according to 6 ADJUSTMENT". Clean the sensor. Output current is instability. Loosening terminals. Affection wave motion of liquid. Tighten terminals. Install stilling tube. Excess current. Short circuit. Make sure that there are no miswiring. - 9 -

HEAD OFFICE : 15-29,Hiroshiba-cho,Suita-city,Osaka 564-0052,Japan. TEL:06-6386-8141 FAX:06-6386-8140 TOKYO BRANCH OFFICE : 67,Kandasakumagashi,Chiyoda-ku,Tokyo 101-0026,Japan. TEL:03-5835-3311 FAX:03-5835-3316 NAGOYA OFFICE : 3-10-17,Uchiyama,Chikusa-ku,Nagoya-city,Aichi 464-0075,Japan. TEL:052-731-5751 FAX:052-731-5780 KYUSHU OFFICE : 14-1,2-chome,Asano,Kokurakita-ku,Kitakyushu-city,Fukuoka 802-0001,Japan. TEL:093-521-9830 FAX:093-521-9834