AC MODULE P72PCS-300W Features Industry leading module power output warranty International quality, safety and performance certifications High-reliability with guaranteed 0/+5 Wp peak power Manufacturing facility certified to ISO9001 Quality Management System standards Beautiful appearance,good durability&easy installation Special design in accordance with requirements of customers Certificates Warranties 10 years for product defects in materials&workmanship 10 years for 90% of warranted minimum power output 25 years for 80% of warranted minimum power output 25 years linear warranty
Electrical parameters at Standard Test Conditions (STC:AM=1.5, 1000W/ m2, cells Temperature 25 ) I-V CURVE Typical Type 310W 305W 300W 295W Max-Power (Pmax) w 310W 305W 300W 295W Max-Power Voltage (Vmp) Max-Power Current (Imp) Open-Circuit Voltage(Voc) Short-Circuit Current (Isc) Max-System Voltage Cell effciency (%) 36.49 36.36 36.19 36.04 8.49 8.39 8.29 8.19 45.98 45.81 45.67 45.59 8.92 8.81 8.74 8.68 DC1000V(TUV)/600V(UL) 18.2 17.9 17.6 17.3 Module effciency (%) 16 15.7 15.5 15.2 MECHANICAL DATA TEMPERAT URE CHARACTERISTICS Dimensions 1956*992*50mm Temp.Coeff.of Isc(TK Isc) 0.045% / Weight 23kgs Temp.Coeff.of Voc(TK Voc) (-0.34%) / Front Glass 3.2 mm tempered glass Temp.Coeff of Pmax(TK Pmax) (-0.47%) / Output Cables: TUV (2Pfg1169:2007) Operating Temperature (-40~+85) 4mm 2 (0.006 inches2), symmetrical lengths 900 mm Nominal Operating Cell Temperature 45 ± 2 Connectors: MC4 compatible IP67 PACKING CONFIGURATI ON cell type: Poly Crystalline silicon, Container 20'GP 40'GP 40'HQ 156mmx156mm Pieces per Pallet 38 38 46 Number of cells: 72 cells in series Pallets per Container 5 11 11 DIMENSIONS AND STRUCTURE Pieces per Container 190 418 506 TESTS, CERTIFICATI ONS AND WARRANTIES Standard tests System certs Certifications Extreme wind and snow loads testing Positive tolerance IEC 61215, IEC 61730 ISO 9001, ISO 14001 TUV, CE, MCS, PV CYCLE, CEC, CHUBB withstand extreme wind (3800 Pascal) and snow loads (5400 Pascal) 0~+3% Junction Box Warranties IP65 Rated 10-year material and workmanship and 25-year output at least 80%.
SR-300 Grid-tie Micro Inverter System SAA 141618 Features U.S. California Rule 21 Certified Thinnest micro inverter in world, 25mm in thickness Designed for frame mount (AC module), as well as rail mount solutions High continuous output power up to 250Wac, recommended for max 330W solar panels High efficiency with 95.5% CEC Globally certified for c-etl-us, SAA, TUV, VDE-AR-N 4105, VDE 0126, G83/2, CEI 021, IEC61727,EN50438 Integrated grounding for easy installation NEMA-6/IP-66/IP-67 enclosure rating Integrated monitoring and power line communication with SR-256 gateway
SR-300 Grid-tie Micro Inverter System MODEL SR-300 INPUT(DC) OUTPUT(AC) SYSTEM EFFICIENCY PROTECTION FUNCTIONS Recommended Max PV Power (Wp) 330 Max DC Open Circuit Voltage (Vdc) 60 Max DC Input Current (Adc) 12 MPPT Tracking Accuracy >99.5% MPPT Tracking Range (Vdc) 22-55 Isc PV (absolute maximum) (Adc) 14 Maximum Inverter Backfeed Current to the Array 0 Rated AC Output Power (Wp) 250 Nominal Power Grid Voltage (Vac) 240 208 230 Allowable Power Grid Voltage (Vac) 211-264* 183-229* configurable* Allowable Power Grid Frequency (Hz) 59.3-60.5* configurable* THD <3% (at rated power) Power Factor (cos phi, fixed) >0.99 (at rated power) Rated Output Current (Aac) 1.04 1.20 1.09 Current (inrush) (Peak and Duration) 12A, 15us Nominal Frequency (Hz) 60 50 Maximum Output Fault Current (Aac) 2.2A peak Maximum Output Overcurrent Protection (Aac) 6.3 Maximum Number of Units Per Branch (20A/15A circuit) 15/11 13/10 14/11 Weighted Averaged Efficiency (CEC) 95.5% Night Time Tare Loss (Wp) 0.08 0.06 0.07 Over/Under Voltage Protection Over/Under Frequency Protection Anti-Islanding Protection Over Current Protection Reverse DC Polarity Protection Overload Protection Protection Degree NEMA-6 /IP-66/IP-67 Environment Temperature -40C +65C Display LED LIGHT Communications Power Line Dimension (W-H-D mm) 180*186*25 Weight (Kg) 1.5 Environment Category Indoor and outdoor Wet Location Suitable Pollution Degree PD 3 Maximum Altitude 2000 M Overvoltage Category II(PV), III (AC MAINS) Product Safety Compliance Grid Code Compliance* (Refer to the label for the detailed grid code compliance) California Rule 21 Certified UL 1741 CSA C22.2 No. 107.1 IEEE 1547 Grid parameters are configurable through a SR-256 or SR-256P3 gateway Compliance NEC 2014 Section 690.11 DC Arc-Fault Circuit Protection NEC 2014 Section 690.12 Rapid Shutdown of PV Systems on Buildings NEC 2014 Section 705.12 Point of Connection (AC Arc-Fault Protection) IEC/EN 62109-1 IEC/EN 62109-2 VDE-AR-N 4105* VDE V 0126-1-1/A1 G83/2, CEI 021 AS 4777.2 & AS 4777.3,EN50438