YSmart Technology Co., Ltd. User Manual. GTI Grid Series. GTI Series Inverters for Grid-connected PV system

Similar documents
MaySun-1200W Microinverter

Microinverter MaySun-1200W-B MaySun-600W-B MaySun-300W-B

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Photovoltaics. MPI Hybrid Series

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

USER MANUAL MPS 1-5KW SERIES

Pure sine wave charger inverter Product Manual

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Pure Sine Wave Inverter 600W-24V User Manual

Qualification certificate

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

LS0512 Solar Charge Controller

USER MANUAL MODEL: 3SPC3.3/106-D72/1100

CPS Energy Balancer. Version: 1.0

WARNINGS, CAUTIONS AND NOTES

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

User Manual Rittal PMC UPS 6kVA

MERU Solar Off-Grid Inverters

Zhejiang Sandi Electric Co., Ltd is an international PV enterprise which is located in the "capital of China's electrical appliances" Wenzhou.

General Precautions. Personnel Precautions

Application. Battery. Public Grid GS HYBRID INVERTER

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

PVES Series User Manual User Manual Shenzhen Pvinergy Technologies Co., Ltd

Smart Charger 12-24V 60A, 1600W

GRUNDFOS DATA BOOKLET. Grundfos RSI. Renewable solar inverter for pump control kw

Installation and Operation Back-UPS BX550CI-CN

LS0512R Solar Light Controller

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

SUN Series Grid Tie Power Inverter (For Wind Turbines)

Uninterruptible Power System

Wind Power Inverter WINDY BOY 5000A/6000A

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

Yueqing Sandi Electric Co., Ltd is an international PV enterprise which is located in the "capital

Solar Inverter 3kW-8kW Inverter (off-grid)

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

SCC-MPPT Solar Charge Controller

Installation and Operation Manual Back-UPS BX1100CI-CN

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

PROwatt 150 DC to AC Power Inverter. Owner s Guide

user s manual Model number

User Manual. Solar Charge Controller 3KW

AeroVironment Universal Solar Pump Controllers

PAC 600 PAC 800 PAC 800 comfort

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

HYBRID 5048E. Hybrid Inverter INSTALLATION AND OPERATION MANUAL. Version 2.0E

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

55185 EMERGENCY PACK FOR LED PANEL TECHNICAL DATA SHEET

The sun as power station

230VAC Power Inverter 400W Owner s Manual

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Home Solar 400 (HS 400) Home Solar 800 (HS 800) Home Backup 400 (HB 400) Home Backup 800 (HB 800) Owner s Manual

S150,S300 Series Pure Sine Wave Inverter User s Manual

Power Inverter 400 MW Owner s Manual

MICROCARE 3 PHASE INVERTER MANUAL

400 Watt Backup Power System Owner s Manual

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

G2 Portable oxygen concentrator User Manual

Off-Grid Solutions (Solar Controller & Invertor)

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

Security Plus Online Uninterruptible Power Supply

1.Safety Summary The following safety precautions should be taken to avoid injury and prevent damage to this and other associated products. To avoid d

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

Sinergex. PureWatts Elite 150. User's Manual. Sinergex Technologies L.L.C. (USA) Website:

Solar Charge Controller

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

SCC-MPPT Solar Charge Controller

315W CMH COMPLETE GROW LIGHT SYSTEM [ V] USER MANUAL

BRAVER UPS. (Uninterruptible Power System) User s Manual

Foreword

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

SCC-MPPT Solar Charge Controller

Pure Sine Wave Inverter USER MANUAL

OWNER S MANUAL POWER INVERTER

User Manual 200Ah INVERTER / CHARGER

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

PureSine 150/300 Pure Sine Wave Inverter User s Manual

Uninterruptible Power Supply

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

OASIS-UM-01. User Manual. Inverter/Charger Oasis 6000 Rev 1.0. Oasis 6000 Series MAY 2012 ISSUE 01

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER

High Accuracy Series REGULATED DC POWER SUPPLY. User s Manual

Duo Battery Charge Controller

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

SUN Series Grid Tie Power Inverter

User Guide for Viridian EV Charging Stations

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Transcription:

YSmart Technology Co., Ltd. User Manual Contact Us Address: No. 30 XinFeng Road,Potoubei Village,Ailian Town,Longgang Dist, Shenzhen 51872,P.R. China Tel: (86)755-85232255 Fax: (86)755-85232255 Email : sales@ysmart-tech.com Website: http://www.ysmart-tech.com http://www.chinasolarregulator.com GTI Series Inverters for Grid-connected PV system

Thanks for using YSmart grid tie microinverters. Read the following instruction carefully before Warranty installation and operating, install and operate as specified by this user manual strictly. There are waterproof products and ordinary moistureproof products, customers can chose different price of products depending on own needs. This user manual is for basical model of ordinary moistureproof products only. Important Safety Information Warranty Conditions Warranty Period: 15-year limited warranty period. Warranty Time Start: From the date of bill of lading. Warranty Evidence: The bill of lading date, product(s) serial number(s), and product(s) model number(s), and a completed warranty card. Read this First This manual contains important instructions for use during installation and maintenance of the YSmartSmart Microinverter. To reduce the risk of electrical shock, and to ensure the safe installation and operation of the YSmart Smart Microinverter, the following safety symbols appear throughout this document to indicate dangerous conditions and important safety 2instructions.. DANGER! This indicates a hazardous situation, which if not avoided, will result in death or serious injury. YSmart grants an implied warranty of 1 year to the inverter from date of purchase for repair or replace the Defective Product free of charge includes freight cost. Furthermore, YSmartprovides an additional limited warranty for 14 years for repair or replace the Defective Product free of charge but non-free of freight charge. For warranty questions, please contact your retailer or installer. If your device has a defect or malfunction during the warranty period, please also contact your retailer or installer. Warranty claims are excluded for: Alterations or repairs to the unit without prior authorization Improper use of device Improper and non-standard installation Improper operation WARNING! This indicates a situation where failure to follow instructions may be a safety hazard or cause equipment malfunction. Use extreme caution and follow instructions carefully. operating the equipment with defective safety devices Impact of foreign objects and force majeure (lightning, surge, storm, fire) Inadequate or nonexistent ventilation of the device disregarding of safety regulations shipping damage The Product has been improperly stored or was damaged while in possession of the Dealer or end user; 2

a. Green LED flash: adjusting for power output, MPPT operating for tracking. b. Green LED long light: indicates inverter locking-in Max. output power operation status. 3. Please note that above operations only run at grid-connected status. Safety Instruction Do not use Smart microinverter in a manner not specified by the manufacturer. Doing so may cause death or injury to persons, or damage to equipment. Perform all electrical installations in accordance with all applicable local electrical codes. Be aware that only qualified personnel should disassemble and repair the Smart Microinverters Troubleshooting a non-operating Smart microinverter WARNING! Only qualified electrical professionals can do the trouble shooting of the Smart microinverter system. WARNING! Do Not disconnect the microinverter from its PV module when the inverter is still operating. Disconnect the inverter from the PV module during running may damage the microinverter and bring electrical hazard to the person nearby. WARNING! Disconnect the AC grid first before disconnecting the inverter from the PV module. To troubleshoot a non-operating Smart Microinverter, follow the steps below in order: 1. Verify the utility voltage and frequency are within ranges shown in the in section Technical Data of this manual. 2. Check the connection to the utility grid. Verify utility power is present at the inverter in question by removing AC, then DC power. Never disconnect the DC wires while the microinverter is producing power. Re-connect the DC module connectors and watch for three short LED flashes. and non-qualified personnel should not install and/or repair. Do not attempt to repair the Smart Microinverter; it contains no user-serviceable parts. If it fails, contact YSmartcustomer service to claim a return merchandise authorization and start the replacement process. Tampering with or opening the Smart Microinverter will void the warranty. If the AC cable connector on the microinverter is damaged or broken, do not install the unit. Before installing or using the Smart Microinverter, read all instructions and cautionary markings in the technical description and on the Smart Microinverter System and the PV equipment. Connect the Smart Microinverter to the utility grid only after you have completed all installation procedures and after receiving prior approval from the local electrical utility company. Be aware that the body of the Smart Microinverter is the heat sink. Under normal operating conditions, the temperature is 15 C above ambient, but under extreme conditions the microinverter can reach a temperature of 75 C. To reduce risk of burns, use caution when working with microinverters. Do NOT disconnect the PV module from the Smart Microinverter without first removing AC power. Keep away from children, no touching, no playing so as not to electric shock when using. Please installed in place of low humidity and well-ventilated so as to avoid inverter overheating, as well as clear around the inflammable and explosive materials. 3

System Function Connect to DC Power Resource directly and Direct-output Power Grid DC power resource refers to devices included solar panels, batteries and wind power generators with AC/DC controller, etc. All DC power supply output voltage fit with inverter input voltage setting range which is 10.8-28VDC. Power grid refers to single phase civil electricity utility grid. Such as 110V(90-140V)and 220V (190-260V)single phase civil electricity utility grid. YSmartgrid tie microinverters can connect to power grid directly and uploading electric power directly because of inverter output current wave form is pure sine wave which is same as civil electricity grid. There must be electricity on power grid and connectivity is first necessity of inverter operating. When there is power outage or fault of power grid, inverters will be not operating. And it is the biggest difference between grid tie inverter and off-grid inverter. AC 0 Angle Phase High Precision Auto-detection MCU process for high-precision detection and analysis after AC 0 angle phase pass through isolation amplifier and input into MCU, phase shift rate is less than 1%, and finally achieving high-precision of cophasal modulation AC combined Output. Synchronous High-frequency Modulation In process for grid connectivity, usually approach with cophasal angle for grid(ie, when total current of inverter and grid is 0, combined current by switch). But our inverter approach for grid with same frequency and same phase is DC to AC first, then rectified AC current into pulse electric which is half-frequency 100Hz, finally combined pulse electric modulation with current of grid and then fed into power grid. Pure Sine Wave Output Adopting Sinusoida PWM process for pure sine wave output which is same wave form of grid. No interference for grid. Superstrong Shadow Resistance Adopting high frequency conversion operating, less transmission loss will be. In cloudy days or inadequate sunshine days, if only there is 3W-5W output from power supply and input into inverter, inverter can be operate AC conversion. But of cause, output is proportional input. The more input power the more output power and vice versa. Inverter can operate in such low input power supply, it s indicate inverter power conversion operating times can be up more 4 Figure 3 LED Indicator 1. Red LED indicator lights up under any conditions as listed below: a. Low-voltage protection(dc input voltage lower than Min. input voltage of inverters ) b. Over-voltage protection(dc input voltage higher than Max. input voltage of inverters) c. Over-temperature protection (inverters will be shut down for power output when the temperature of body of inverters higher than 65-75.) And inverter will be automatically restart up when the temperature of body of the inverter down to 40-50. d. Power grid fault protection (when 110VAC or 220VAC grid power outage and/or tripped. e. Islanding protection: inverter will be automatically shut down for power output when disconnect with power grid. 2. Green LED Indicator Operation:

Figure2 3 Stackable connection (The purpose of small power inverter become high-power inverter) In order to achieve higher power use requirements, the use of this product can be stacked, such as: 5 grid inverter 300W of stack used is equal to 1500W, and the number of open stacks ( No Quantitative Restrictions). Used as shown in Figure 4: In order to achieve higher power use requirements, the use of this product can be stacked, such as: 5 grid inverter 300W of stack used is equal to 1500W, and the number of open stacks ( No Quantitative Restrictions). Used as shown in Figure 4: than 8 hours every day, and this is an advantage which is large power inverter cannot be compared with. Maximum Power Point Tracking (MPPT) Output of solar array had characteristics of nonlinear. Output affected by sunrays, ambient temperature and loadings, and output power of solar array can be maximized at a certain output voltage only. Solar array output power operating at peak voltage output which we called MPP-maximum power point. For more effectively operate for solar array, it s important for track down max output power of solar array. YSmartgrid tie microinverter MPPT operating principle: in a specified period, MPU actively adjustable for PWM s duty ratio regularly, changing output current of solar panels and leading to output voltage changing, checking output voltage and output current of solar panels, computing output power of solar array, then track down max power point managing by maximum power point tracking strategy. APL (Power Automatically Locked) When MPPT track down the max power point, inverter will be operating of locking in max power point automatically, so as to keep operating max power output of DC power supply device within a corresponding period and achieve more stable output power. Automatically Adapt To Different Power Loading Adapt to different power loading because of Synchronism in same frequency between inverter output and power grid. Such as inductive load, resistive load, soluble load. Constant Current, Constant Power, Current Limiting Protection Synchronism in same frequency between inverter output and power grid, follow up power grid and take power grid as strong backup to achieve constant current, constant output power, without any overload and any over-current. Automatically Turn Off and Stop Output When Fault of Grid(Islanding Protection) When there is fault or outage of electricity power grid, inverters will be turn off automatically and stop operating within 0.5 second. High-Frequency High Conversion Rate Adopting magnetic core which import from Japan for inner transformer. High conversion and less loss make higher efficiency of output. 5

Parameter Table Power 200W 300W 400W 500W 600W 800W 1000W Solar panels 200W 300W 400W 500W 600W 800W 1000W DC MAX input 240W 360W 480W 600W 720W 960W 1200W DC input range 10.8-28V MPPT Voltage 15.5-20VDC DC MAX current 15A 20A 25A 30A 35A 45A 60A AC MAX output 230W 330W 430W 550W 630W 830W 1100W AC output range 120VAC(90-140VAC) or 230VAC(190-260VAC) Frequency range 50Hz/60Hz(Auto control) Power Factor >97.5% THD <5% Phase Shift <2% Package 200-600W 800-1000W 1 Net Weight 1.3KG 2.0KG 2 Gross Weight 2.0KG 2.7KG 3 Inner Box (L x W x H) 30*20.3*11.3cm 39*20.3*11.3cm 4 Carton(L x W x H) 42*31.5*35.5cm(6pcs/ctn) 42*40.5*24.2cm(4pcs/ctn) Installation and Connection 1.Installation 1. Red terminal: Connect DC positive, black terminal: Connect DC negative. Shown in Figure 1. 2. AC socket: Connection to the mains. The AC cord to the inverter 3 foot outlet, then the AC cord to home 3PIN AC outlet. Are shown in Figure 2. 3. Switch: properly connected; turn on the switch, the inverter to work. Efficiency 120VAC(90-140VAC) Peak Efficiency 90% 90% 88% 87% 85% 83% 81% Stable Efficiency 88% 87% 86% 84% 84% 81% 79% Efficiency 230VAC(190-260VAC) Peak Efficiency 91% 90% 88% 87% 85% 85% 82% Stable Efficiency 89% 88% 87% 85% 85% 83% 80% Protection Islanding; Short-circuit; converse connection; Low Voltage; Over Voltage; Over temperature Protection Work Temperature -25-65 Work Humidity Grade of Waterproof 0%~90%RH non-condensing Indoor design Show 1 Red and 1 Green Cooling Fan Stand-by Power 2-3W EMC EN61000-6-3:2007 EN61000-6-1:2007 Grid Disturbance EN 50178+EN 62109-1+VDE0126-1-12 Grid Detection DIN VDE 1026 UL1741 Certificate CE 6 Figure 1 2. Application of Street lights: Use this product, do not need to add a fan controller, solar panel controller, battery. Connection Method 1 (Figure 4 below): This connection method, wind energy, solar energy can supply to the grid at the same time, the highest efficiency.