Using the Universal Pendant with Patient Cable

Similar documents
TelePatch. User Manual

1. Connect the Tester to the L300 FS Cuff plug holes. See Figure Figure 11-1: Tester connected to the L300 FS Cuff.

When the RF Stim Unit is fully charged, the status light on the RF Stim Unit will be solid GREEN.

IMPORTANT SAFETY INSTRUCTIONS. PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE SETUP AND USE. KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE

Vercise TM DBS Charging Handbook

IMPORTANT SAFETY INSTRUCTIONS. PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE SETUP AND USE. KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE

Solar Pack Installation

MOOG Medical Devices Group Curlin 6000 Series Ambulatory Infusion Pump PATIENT GUIDE

Booster Car Seat User Guide

PureLite XStream. Self-Contained Powered Air Purifying Visor System. User Manual

The Bio Tuner. Model BT6pro Manual. Contents Welcome to SOTA... 2 Before Using... 2 Learn More... 2 Complete unit includes... 2 do not use...

CDT PLUS Series Electronic Dog Trainer Owner s Manual

EZ Way Shower Trolleys

Nucleus CP910 and CP920 Sound Processor User Guide

SERVICE GUIDE For WARN PULLZALL 24Vdc P/N &

BlueFin User's Manual. Version 1.1

Quickie S-11 Service Manual

User Manuel. Titan Hummer XL

Booster Car Seat. User Guide. in location on bottom of base. IS0174E_ Artsana USA, Inc. 01/19

Using Your CADD Prizm Pump

Serena Remote Controlled Shades

12V 160W Folding Portable Solar Panel Kit KDSLR160PNLA User Manual

Milford Communications Battery Back-Up Notice

Charging the NESS H200 Wireless System

Patient Information CADD-Legacy 1 Pump

Columbia Car Seat. User Guide. IMPORTANT Please retain this User Guide for future reference. Conforms to ECE R44.03 Universal

Remove 4 circled pins. Route wiring along dashed line. Remove the 2 9mm nuts and black retaining plate that secure extractor.

SECTION 1 6 INSTRUMENTS AND CONTROLS. Comfort adjustment. Front seat... 42

NAUTILUS SNUGLOCK TM LX/DLX

Aqua SnakeEye. OA-09 Extended Life NiMH Battery. Operators Manual

CAUTION: Surfaces may become hot and cause burns if

Fabric Replacement Top and Doors with Tinted Side and Rear Curtains Installation Instructions

Maintenance and Cleaning

DURABLE DEPENDABLE PROVEN. IOTA Engineering tel:

R710. R710 Product Manual

H 2 O 1800 PLUS Series with SmartLED Owner s Manual

Wireless Tire Pressure and Temperature Monitoring System Instruction Manual Model #: TM Cap Sensors

BuzzClip Quick Start Guide

Instruction Booklet. WireFree TM Solar Pack #

Setting Up the NESS L300 Plus System

INSTRUCTION MANUAL 2885 Country Dr. #190 St. Paul, MN

Electric Car User Manual

Getting Started. Evergaze LLC 2018 All Rights Reserved

Installation, Usage & Maintenance Guide

Dealer4 Maintenance, Adjusting and Cleaning Manual ver: 1.0

Wireless Tire Pressure and Temperature Monitoring System Color Display Manual. Wide Screen Color Display Model #: TST-507-D-C

Power Sliding Door (PSD) Diagnostic Approach. Fixing Intermittent Malfunctions. Power Sliding Door (PSD) Diagnostic Information

Instruction Manual Recharging Aids and Dock

INSTALLATION MANUAL SPECTRUM BRAKE CONTROL

INSTRUCTION MANUAL. Kids Ride-On Motorcycle SKY Ver. 3

Parkit360 Transformer

IMPORTANT NOTICES. speed of 3 miles per hour before the motor. The Razor electric scooter must reach a. will engage. Owner s Manual + Safety Handbook

Pivotell Advance Automatic Pill Dispenser Instructions

INSTALLATION INSTRUCTIONS

PATRIOT TM UPGRADE KIT PART NUMBER: F-12PPAP INSTALLATION INSTRUCTIONS MANDATORY LEAVE THIS MANUAL WITH LIFT OWNER

Oxford. Manufacturer s Contact Details. Contents. Oxford Presence. English

Roller Shade Installation Instructions

TR 2000/3000. Operating manual. Shower Trolleys. Hygiene Equipment Designed for People

HEAVY-DUTY SIZE MODEL User/Caregiver Manual FOLD & GO Wheelchairs A Division of OneKubedDESIGNS, LLC.

The Duck Dunker. Assembly & Setup Instructions WARNING! DO NOT RUN THE DUCK DUNKER OUT OF THE WATER. DAMAGE TO UNIT MAY OCCUR & WILL VOID WARRANTY!!!

7 Handle Tubes. 10 Charging Jack 11 LED Indicator 12 ON/OFF button

GoFitTM. Booster Car Seat User Guide. in location on bottom of base. IS0147E_ Artsana USA, Inc. 01/19

IMPORTANT SAFETY INSTRUCTIONS

SOOTHING SOUNDS BOUNCER SEAT

Rocket. Two Seat Bicycle Trailer. Model Number ACIS99ROCKTBLU

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

OWNER'S MANUAL & INSTALLATION INSTRUCTIONS 6500 Series

SECTION 1 3 OPERATION OF INSTRUMENTS AND CONTROLS Occupant restraint systems

Operating and Service Manual For Amtech Wall Mount Tables.

5 WEARING YOUR ZIO MANUAL. Record any events during your wear period here, the myzio app or at myzio.com.

Product Handbook. Electric Power Board. Powered Personal Transportation. FOR THE BLADEZ XTR Lite 250 ELECTRIC POWER BOARD

REMOTE CONTROLLED DOG TRAINING COLLARS

DWHOIST. Drywall Hoist Assembly & Operating Instructions

INSTALLATION AND CUSTOMER CARE INFORMATION 80 SERIES & 90 SERIES TREATMENT STATIONS

Duster Deck Cover Installation Instructions

AG-HA-2500N GASOLINE GENERATOR

Thank you for purchasing a Dillenger F1 Folding Bike, please read this manual before using your new electric bike.

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

GoFitTM. Booster Car Seat User Guide. in location on bottom of base. IS0147.2E Artsana USA, Inc.

REMOTE CONTROLLED DOG TRAINING COLLARS

Problems? PLEASE DO NOT TAKE YOUR AIR HOGS INTRUDER TO THE STORE! Call our Flight Technicians at: INTRUDER RADIO-CONTROLLED AIRPLANE

Braun ThermoScan PRO 6000 Thermometer Inservice MC

with Touch & Go Feature

AFFIX TM Booster Seat. Owner s Manual PD202326A 5/12

User s Guide. MCM Backpack. Model BP-1. Part # 12715

THE APPLICATION OF VINYL DECALS REQUIRES A DEGREE OF DEXTERITY AND CON- CENTRATION.

Marlin Bath Lift BLM-8200 WARNING! Read ALL instructions before using this product!

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference

TALON 22 WHEEL & TALON X-TREME 38 WHEEL TPMS, UP to 188 PSI PRESSURE AND TEMPERATURE WITH CAP OR FEEDTHRU SENSORS

THE PHOENIX MODEL 1800 KNEE CPM OPERATOR'S MANUAL SERIES Seeds Road Grove City, OH Fax

12V Jaguar CX-75. Owner s Manual and Assembly Instructions

REMOTE CONTROLLED DOG TRAINING COLLARS

BodyGuardTM 323. BodyGuard 323 Multi-Therapy Ambulatory Infusion Pump. Patient Guide

WELDING HELMET INSTRUCTIONS. Part #20520

Magician Comfy. Owner s Manual

USER MANUAL. Your ZINGO DRIFTA 360 warranty must be registered online within 7 days of purchase.

Trike. Instructions. Model Number: 72633

Occupant Protection ! WARNING: FASTENING THE SEAT BELTS

TABLE OF CONTENTS Safe Use Checklist Registration & Recal Assistance Warnings Base Features Carrier Features Securing Child In Carrier

Eclipse Plus VA UPS and Surge Suppressor User s Manual

Transcription:

Using the Universal Pendant with Patient Cable Long-Term Holter Procedures What you need to get started: Patient Cable 3-Lead or 5-Lead Universal Pendant and Battery Skin Prep Pad Razor, if necessary (not supplied) Packet of Electrodes Help? Online: medicompinc.com/patient-center Email: patientsupport@medicompinc.com Phone: 877-996-5553 Please Note These instructions supplement the TelePatch TM User Manual. Please refer to the manual and other helpful resources at medicompinc.com/telepatch/userinfo. Warning Using wired electrodes and the lanyard accessory may present a choking hazard. Do not wear the lanyard while sleeping or operating machinery. Adult supervision is required. 600 Atlantis Road Melbourne, FL 32904 Tel. 877-996-5553 www.medicompinc.com

1 Prepare Your Skin Remember, when looking in a mirror, your left and right sides will be reversed! Take care in preparing your skin for application of the adhesive skin patches (electrodes). Good skin preparation means better ECG signal traces that, in turn, are easier for the doctor to review and evaluate. Using the illustrations on the right as a guide, choose areas of the chest that are flat and not very muscular. Avoid skin folds or creases, irritated skin and scars. 1. Use PLAIN soap and water No soap with lotion, oil, or fragrance 2. Dry thoroughly 3. Shave if necessary 4. Rub areas with Skin Prep Pad 5. Let dry 2 Apply Electrode Patches 3-Lead Patient Cable 5-Lead Patient Cable Open a packet of electrodes. Snap the electrodes onto all the color terminals of the Patient Cable. Then, one by one, peel the backing from each electrode and apply it to your chest using the placement as shown in the illustrations on the right. Be mindful of where each color terminal should be placed. Snap Electrodes Peel backing Adhere to chest Remember, White on when applying electrodes. This will help you remember to always place the white electrode on the upper right side of your chest. Change the electrode patches every two days. When re-applied, change their location slightly to lessen skin irritation.

3 Assemble Pendant and 4 Start the Holter Attach a fully charged Battery onto the back of the Universal Pendant, and then lock it in place by sliding the small latch into the locked position. The Medicomp label on the battery should be face up. Green Light Battery Pendant Whenever the Pendant is powered on, the green light will flash rapidly. Slide to Lock The Pendant should power on when a charged battery is inserted, indicated by flashing lights and a three-tone chirping sound. If it does not start, turn on the Pendant manually. You may turn the Pendant on and off by pressing and holding the Power button. (See illustration below.) Insert the assembled Pendant into the. You should hear a click indicating the Pendant is securely inserted. To start monitoring, press the Symptom button three (3) times. You know the Pendant is working properly when you see the green light flashing slowly, about every four seconds. Any other visual or audible indication may mean the Pendant needs attention. Attach the Patient Cable by inserting the flat plug into the Cable Port at the base of the. Universal Pendant Battery Attached on Back Press 3 Times Cable Port Patient Cable Clip the provided lanyard accessory onto the loop at the top of the Cable Cradle to wear it around your neck. Alternatively, you may carry it in your pocket but be careful that the Patient Cable remains firmly connected. Tip: Take care not to insert the Pendant upside down. Be sure the rounded end of the Pendant the end at the bottom below the power button is flush against the matching rounded part of the cradle. To power the Pendant on or off, press and hold the Power button. The Pendant should automatically power on when a new Battery is inserted. If not, power it on manually. Whenever you power on the Pendant, press the Symptom button three times to start monitoring again. Your Long-Term Holter procedure is now running

During Your Procedure Wearing the Monitor This device is designed for 24/7 monitoring, typically for up to 14 days. Your doctor will prescribe the exact duration of your procedure. Wear the with the Pendant, keeping it powered on and keeping the electrodes attached to your chest, at all times day and night until the end of your procedure. Make sure the Pendant is always pushed fully down in the and the Patient Cable is firmly plugged into the Cable Port. Check for a slow flashing green light on the Pendant to make sure it is working properly. Wear the monitor when you sleep and during your regular daily activities such as working, exercising, sexual activity, lounging, etc. But always follow your doctor s instructions. DO NOT get any part of the monitoring system wet. See Showering, Bathing, and Swimming below. The may be worn on the included breakaway lanyard or kept in a pocket. Make sure the Patient Cable stays firmly attached. Sleeping Here are suggestions for sleeping: Place the with Pendant beside you with the wires extended as much as possible so that you don t roll over the monitor. Wear a nightshirt with a breast pocket and place the monitor in the pocket. DO NOT wear the lanyard around your neck while sleeping. Charger Cord Pendant Battery Charging The Pendant Battery is designed to last approximately seven days when fully charged. The Pendant will beep and display a flashing orange light when it needs to be recharged. An extra Battery should be included in your kit. Simply replace the Battery immediately when it is necessary, so as to not interrupt your procedure, and then charge the depleted battery. Charger Port Locate the Battery Charger and Charger Cord in your monitor kit. Changing Electrodes Change the electrodes every two days. When re-applying, change their locations on your chest slightly to lessen skin irritation. Review Step 2 for proper placement of the Patient Cable s color terminals. All Medicomp electrodes are hypoallergenic. Minor skin irritation is normal while wearing any electrode. If you experience excessive irritation that may interrupt your procedure, please call us for assistance at 877-996-5553. Showering, Bathing, and Swimming DO NOT shower, bathe, or swim with the, Pendant, or Patient Cable, or in any other way get them wet. First, turn off the Pendant by pressing and holding the. Unsnap the terminal heads of the Patient Cable from the electrodes. Place the, Pendant, and Patient Cable away from the water. You may keep the electrodes attached to your chest after removing the Cable. After drying your skin, re-attach the Patient Cable s terminals to the electrodes. Be mindful of the proper placement of each color terminal. See Step 2. Press firmly on each electrode to make sure they are secure against your skin. Power the Pendant on, and then press the Symptom button three times to start monitoring again. See Step 4. Battery Charger Pendant Battery Lights First, power off the Pendant. Then, unlock the Battery by sliding the latch to the unlocked position and pull out the Battery. Insert the Pendant Battery into the Battery Charger and lock it in place by sliding the small latch into the Lock locked position. Insert the Charger Cord into the Battery Charger Port and plug it into a wall outlet. Make sure the outlet is not controlled by a light switch. An orange light will flash on the Battery Charger while charging. When the light turns green, the battery is fully charged. Recording Symptoms Whenever you experience a symptom, press the Symptom button AND write into a diary the following: the date and time, the symptom you felt, your location, and what you were doing. Your doctor s office should provide you with a diary form, but you may use a blank piece of paper. Be sure to return your diary logs to your doctor when you return the monitor. Be sure to notate in your diary the date and time of any exercise or overexertion.

Monitor Diagram Pendant Symptom Button Lanyard Hook Rounded Bottom End Press and Hold (On/Off) Battery Locked Unlocked Battery Lock Latch Extra Supplies You should have enough supplies in your kit to last through the end of your procedure. If you need additional supplies, please contact your doctor s office or the facility where you received the monitor. Returning the System After you have worn the monitor for the full number of days your doctor prescribed, promptly return the equipment and your completed diary to your doctor s office so your data can be analyzed. Property of Medicomp All equipment is property of Medicomp. Please return promptly after use. Unreturned items may be invoiced. QSG0000710-01A