INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

INSTALLATION INSTRUCTIONS

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

Fiber Connector Shelf (CCS)

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

8400 Series Fiber Distribution System

OFS Fitel LST1U-072/7 and LSTLW Instruction Sheet (LaserWave) Fiber Optic Comcode: Termination Shelf Installation

Environmental Distribution Center (EDC-06P-NH)

Instructions for Use - Opt-X 1000i Enclosure

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

FIBER CONNECTOR SAFETY WARNINGS

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

Instructions for 2-row monitoring only

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

PLEASE READ THESE INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

Instructions for 2-row monitoring only

PLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

Opticom Rack Mount Fiber Enclosures

Fiber Splice Panel Rack Mount User Manual

FL2000 Termination/Splice Panels User Manual

= Experienced

Universal Splice Tray Installation Instructions

Replacing the T320 Cooling System Components. Replacing a T320 Fan Tray. Removing a T320 Front Fan Tray

Overview. Chassis Packaging

Fiber optic splice closure

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

TOYOTA TUNDRA COLD AIR INTAKE Preparation SEQUOIA

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

Cabinet and Rack Installation

GENUINE PARTS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SWING DOOR SOFT ENCLOSURE (part# 16733)

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

Cisco CRS Carrier Routing System 16-Slot Line Card Chassis Enhanced Router Unpacking, Moving, and Securing Guide

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

INSTALLATION MANUAL FOR PILOT WORKSTATION

w w w. h d o n l i n e s h o p. d e LAYBACK LICENSE PLATE AND TURN SIGNAL RELOCATION KIT INSTALLATION GENERAL -J03892 REV Kit Number

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack)

Cabinet and Rack Installation

Contractors Guide Central Inverter System Installation

SCION xd INTERIOR LIGHTING UPGRADE Preparation

INSTALLATION INSTRUCTIONS CASCADE 3181 DUO DELIVERY SYSTEM TO PREFERENCECOLLECTION 5580

Cabinet and Rack Installation

FOG LAMPS INSTALL KIT

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

Fiber Optic Splice Module

SPACESAVER EC-300 A ELECTRICS

3875 Cypress Drive Petaluma, CA Fax

SAM S KIOSK & SET ASIDE USER MANUAL INSTALLATION & MAINTENANCE

INSTALLATION INSTRUCTIONS

axcs Magellan CMU Installation, Operation and Care Manual

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

Westell Boxer BXM HE Outdoor Cabinet with 48VDC 1,800 Watt Heat Exchanger

Universal Network Zone System Part Numbers: Z23U-****

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Installation Notes. PlayPorTT Kiosk Anti-Tip Safety Cable. (p/n )

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

2-row and All-row systems included.

INSTALLATION INSTRUCTIONS

INFINITY MULTA SERIES

For additional information, please refer to the Installation/Operation Manual

VISOR AUDIO KIT P/N , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

ThermoLite 110W-330W Solar Panel Installation Instructions

GPS AutoSteer System Installation Manual

Centrix System. Features and Benefits

STACK-ON UNIT WARNING. Illustration 1

Soffit Application Sound Enclosure

Instruction, EDGE8-04U Quick Start Guide

Predator Medium Floodlight Wet Location

PanView iq (PViQ) Fiber Tray

PFT-71 Transom Connector w/fin Installation Instructions

TOYOTA TUNDRA HANDS FREE BLU LOGIC Preparation

SMART ELECTRIC TAILGATE LIFT SYSTEM Document # Created ACH 09/19/2018 Revised ACH 10/02/18 A2

INSTALLATION MANUAL. Melink Corporation (513) Revision

LOCKN LOAD MOUNTING KIT

3000SC Fiber Optic Splice Closure

CellPak CP538MMD Meet-Me Demarc Enclosure

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

GP1-R FULL EXHAUST SUZUKI GSX-R600 / GSX-R

GENUINE PARTS INSTALLATION INSTRUCTIONS

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

TOYOTA TACOMA HANDS FREE BLU LOGIC Preparation. Item 5 Item 6 Item 7 Item 8. Item 4. General Applicability Note: Recommended Tools

INSTALLATION NOTES: nbeckon-26

WLP Series Wall Mounts (WLP Series Low Profile Wall Mount Enclosure) Installation Instructions

General Applicability Note: Recommended Tools. Personal & Vehicle Protection Safety Goggles Seat Covers Floor Covers Special Tools. Installation Tools

SYSTIMAX 360 FTP Evolve Panel Instructions

Assembly and Modular Table Power System Installation Instructions for Train Tables

Dukane Projection System (DPS)

GENUINE PARTS INSTALLATION INSTRUCTIONS

Transcription:

TABLE OF CONTENTS GENERAL...2 SPECIFICATIONS...2 PACKAGE CONTENTS...2 PACKAGE CONTENTS: ACCESSORIES...3 REQUIRED TOOLS...3 ADD-ON COMPONENTS...3 CABINET MOUNTING HAND-HOLE OR VAULT...3 CABINET MOUNTING PAD...4 LIFTING EAR REMOVAL...4 LOCK AND UNLOCK EXTERIOR DOORS...4 IDEAA SPLITTER MODULE INSTALLATION MOUNT IDEAA SPLITTER MODULE... 5 IDEAA SPLITTER MODULE INSTALLATION ACTIVATE IDEAA SPLITTER MODULE... 6 IDEAA SPLITTER MODULE INSTALLATION CONNECT DISTRIBUTION FIBER... 7 PASS THROUGH CONNECTION...8 1

GENERAL The IDEAA Exterior Distribution Cabinet (EDC) provides a convenient modular approach to centralized fiber distribution. All sizes of the EDC utilize the IDEAA splitter module to enable versatility across the platform. The EDC utilizes innovative jumper routing to enable efficient fiber management utilizing equal length pigtails for the entire cabinet. SPECIFICATIONS Parameter Splitter Capacity Value Up to 28 Modules Input/Pass Through Ports 144 Dimensions - (L x W x H) in. (cm) 48.00 x 42.50 x 20.00 (121.92 x 107.95 x 50.80) PACKAGE CONTENTS A. IDEAA Exterior Distribution Cabinet with Skirt B. Fiber Input Cables C. Fiber Distribution Cables 2

PACKAGE CONTENTS: ACCESSORIES Hex-Head Screw Kit Skirt Mounting Hardware Kit Skirt Panel Attachment Hardware Kit REQUIRED TOOLS 216 style Socket Tool Phillips Head Screwdriver ADD-ON COMPONENTS SC IDEAA Module 1 x 32 LC IDEAA Module 2 x 32 LC Input / SC Output IDEAA Module - Dual 1 x 16 CABINET MOUNTING The EDC will be shipped with the rear skirt panel removed. HAND-HOLE OR VAULT MOUNT 1. Route the cable stubs into the hand-hole or vault opening. 2. Set the EDC into place by aligning the skirt mounting holes with the hand-hole or vault mounting holes. 3. Secure the EDC by installing and tightening the four threaded bolts and washers, included in the Skirt Mounting Hardware Kit. (Figure 1) 4. Place the rear skirt panel at approximately a 10 angle to the base of the cabinet, so that the panel will slide onto the mounting brackets. (Figure 2) Figure 1 Figure 2 Note: To remove either the front or rear access panels the same approximate 10 angle must be utilized when lifting the door. 5. With the rear skirt panel now attached at both ends, rotate the panel so that it is lying flat on the ground. Attach the grounding strap from the underside of the EDC to the grounding bar located on the skirt panel. 6. Secure the rear skirt panel to the EDC using the Skirt Panel Attachment Hardware Kit. 3

PAD MOUNT Note: EDC comes outfitted with a gasket pre-adhered to the underside of the skirt 1. Position the mounting template on the concrete pad in the desired location. 2. Install mounting holes into the concrete. 3. Insert wedge anchors into the mounting holes and activate the anchor nuts. 4. Uncoil the cable stubs and route through the conduit in the concrete pad. 5. Set the EDC into place by aligning the skirt mounting holes with the wedge anchors. 6. Secure the EDC with the wedge anchor washers and nuts. 7. Place the rear skirt panel at approximately a 10 angle to the base of the cabinet, so that the panel will slide onto the mounting brackets. (Figure 3) Note: To remove either the front or rear access panels the same approximate 10 angle must be utilized when lifting the door. 8. With the rear skirt panel now attached at both ends, rotate the panel so that it is lying flat on the ground. Attach the grounding strap from the underside of the EDC to the grounding bar located on the skirt panel. 9. Secure the rear skirt panel to the EDC using the Skirt Panel Attachment Hardware Kit. Figure 3 LIFTING EAR REMOVAL Note: Removing the lifting ears is an optional procedure that will not alter or enhance the performance of the EDC. 1. Using a standard 216 style tool, or similar, remove the two bolts that attach the lifting ear to the EDC. 2. Remove lifting ear. 3. Replace the bolts and tighten using a standard 216 style tool, or similar. LOCK AND UNLOCK EXTERIOR DOORS 1. Using a standard 216 style tool, or similar, turn the locking bolt located at the top of the EDC door a ¼ turn. Note: When locking the EDC, the right door must be closed followed by the left door. The locking bolt located on the left door will be used to secure and lock both EDC doors. Note: A pad lock, not provided, may be utilized if additional security is desired. 4

IDEAA SPLITTER MODULE INSTALLATION MOUNT IDEAA SPLITTER MODULE 1. Using local engineering practices, determine the location of the IDEAA Splitter Module to be installed within the EDC. 2. Remove the two screws at the base of the cover plate in the desired module location, using a Phillips head screwdriver. (Figure 4) Figure 4 Note: These screws will be re-used to mount the IDEAA Splitter Module into the EDC. 3. Using the provided Hex-Head Screw Kit, attach the bottom side of the IDEAA Splitter Module to the removed cover plate. (Figure 5) The EDC is shipped with quantity (56) hex-head screws for mounting the IDEAA Splitter Module: #10-32 x ½" with 3/8" Hex Head 4. Re-mount the cover plate with the attached IDEAA module into the desired location, using the screws removed in Step 2. (Figure 6) 5. Repeat Steps 1 4 for each IDEAA Splitter Module that needs to be mounted. Figure 5 Figure 6 5

ACTIVATE IDEAA SPLITTER MODULE An IDEAA Splitter Module that has been mounted into the EDC is not active until it has been connected to the Input Field. Caution: When working with fiber optics, do not look directly into the end of the fiber cable or adapter port. A power meter may be used to determine if the cable or port is dark. Or use locally accepted fiber optic safety practices. 1. Use local accepted practices to clean the connector end face at both ends of the jumper provided with the IDEAA Splitter Module. Figure 7 2. Plug the jumper cable into the black input port on the IDEAA Splitter Module. (Figure 7) Note: When mounted on the cover plate, the black input port will be located in the bottom left corner of the adapter field Figure 8 3. Using local engineering practices, determine the port to be used on the input panel for activating the IDEAA Splitter Module. Plug the opposite end of the jumper into the desired port on the input panel. (Figure 8) 4. Use the foam fiber relief to route the jumper cable to the fiber routing section of the EDC. (Figure 9) Figure 10 Figure 9 5. Route the remaining jumper slack through the fiber routing section of the EDC. (Figure 10) Note: For best practice, it is recommended that the jumper slack be routed around the upper most cable routing guide. Avoid looping the slack through the fiber routing section of the EDC. 6. Use local accepted practices to label the input fiber connection in the appropriate space on the door label, as applicable. Note: The lance located below the input port on the IDEAA Module cover plate may be used for additional labeling. As an alternative, self-adhesive label may be placed on the cover plate. 6

CONNECT DISTRIBUTION FIBER 1. Remove the shipping screw from each end of the swing down tray. A total of two shipping screws will be permanently removed. (Figure 11) Figure 11 2. Using local engineering practices, determine the appropriate distribution fiber to be connected. Remove the corresponding fiber storage cartridge from the swing down tray by pushing in and pulling up on the cartridge arms. (Figure 12) Note: The cartridges and distribution fibers are numbered to assist in fiber identification. Additionally, distribution fibers may be identified by placing a red light on the customer side of the fiber, and locating the fiber on the swing down tray. (Figure 13) Figure 12 Figure 13 7

3. Remove the desired distribution fiber from the cartridge by sliding the connector out of the housing location and continue to route the cable out of the cartridge. 4. For best practice, it is recommended that the distribution fiber be routed back to the grommet located at the cascade point. Ensuring the distribution fiber has a clear path to the fiber routing section of the EDC. 5. Use local accepted practices to clean the distribution fiber connector end face. 6. Connect the distribution fiber to the appropriate port on the IDEAA Splitter Module. (Figure 14) 7. Use the foam fiber relief to route the distribution fiber to the fiber routing section of the EDC. Employing a similar technique to that used with the activation jumper cable. 8. Route the remaining distribution fiber slack through the fiber routing section of the EDC. (Figure 15) Figure 14 Note: For best practice, it is recommended that the distribution fiber slack be routed around the upper most cable routing guide. Avoid looping the slack through the fiber routing section of the EDC. 9. Use local accepted practices to label the distribution fiber connection in the approriate space on the door label, as applicable. 10. Repeat Steps 2 9 for each addition distribution fiber needing to be connected. Note: Unused fiber should remain the in the fiber storage cartridge until needed. Figure 15 PASS THROUGH CONNECTION 1. Using local engineering practices, determine the appropriate distribution fiber to be used for a pass through connection. Remove the corresponding fiber storage cartridge from the swing down tray by pushing in and pulling up on the cartridge arms. 2. Remove the desired distribution fiber from the cartridge by sliding the connector out of the housing location and continue to route the cable out of the cartridge. 3. For best practice, it is recommended that the distribution fiber be routed back to the grommet located at the cascade point. Ensuring the distribution fiber has a clear path to the fiber routing section of the EDC. 4. Use local accepted practices to clean the distribution fiber connector end face. 5. Connect the distribution fiber to the appropriate port on input field. 6. Use the foam fiber relief to route the distribution fiber to the fiber routing section of the EDC. Employing a similar technique to that used with the jumper cable. 7. Route the remaining distribution fiber slack through the fiber routing section of the EDC. 8. Repeat Steps 1 7 for each addition pass through connection. 8