Asia Pacific Research Initiative for Sustainable Energy Systems 2011 (APRISES11)

Similar documents
Effect of Hybridization on the Performance of Fuel Cell Energy/Power Systems (FCEPS) for Unmanned Aerial Vehicle (UAV)

Load Frequency Control of a Two Area Power System with Electric Vehicle and PI Controller

Research Title DYNAMIC MODELING OF A WIND-DIESEL-HYDROGEN HYBRID POWER SYSTEM

Hawaii Energy and Environmental Technologies (HEET) Initiative

Design and Control of Hybrid Power System for Stand-Alone Applications

Dynamic Behaviour of a Fuel Cell with Ultra Capacitor Peak Power Assistance for a Light Vehicle

Hawaii Energy and Environmental Technologies (HEET) Initiative

Electric Transportation and Energy Storage

Hawai'i Island Planning and Operations MEASURES TO IMPROVE RELIABILITY WITH HIGH DER

Essential Reliability Services Engineering the Changing Grid

A Novel Proton Exchange Membrane Fuel Cell-Battery Partial Hybrid System Design for Unmanned Aerial Vehicle Application. Dr.

Genetic Algorithm Based PI Controller for Frequency Control of an Autonomous Hybrid Generation System

The future role of storage in a smart and flexible energy system

Power Management in a Standalone Solar/ Fuel cell/ Battery Hybrid Power system

Interaction of EVs In a High Renewables Island Grid

AN IN-LAB GRID FOR THE DEVELOPMENT OF ENERGY STORAGE FOR USE WITH WIND ENERGY

Battery Energy Storage System addressing the Power Quality Issue in Grid Connected Wind Energy Conversion System 9/15/2017 1

Site Visit to Green Electric Energy Park at Curtin University, Perth, Western Australia. Institution of Engineers Sri Lanka Western Australia Chapter

A STUDY ON ENERGY MANAGEMENT SYSTEM FOR STABLE OPERATION OF ISOLATED MICROGRID

Hawai i Energy and Environmental Technologies (HEET) Initiative

Microgrid Storage Integration Battery modeling and advanced control

Hybrid Three-Port DC DC Converter for PV-FC Systems

A Battery Equivalent Model for DER Services

Ancillary Services & Essential Reliability Services

Control of a Fuel-Cell Powered DC Electric Vehicle Motor

Beyond 60% - Pioneering H-class Efficiency with World Class Flexibility

Battery-Ultracapacitor based Hybrid Energy System for Standalone power supply and Hybrid Electric Vehicles - Part I: Simulation and Economic Analysis

Sustainable Energy Mod.1: Fuel Cells & Distributed Generation Systems

An Introduction to Ancillary Services

STABILIZATION OF ISLANDING PEA MICRO GRID BY PEVS CHARGING CONTROL

Demand side support in power system control allowing to accommodate more renewable energy sources

SOLAR GRID STABILITY

The MathWorks Crossover to Model-Based Design

GT-POWER/SIMULINK SIMULATION AS A TOOL TO IMPROVE INDIVIDUAL CYLINDER AFR CONTROL IN A MULTICYLINDER S.I. ENGINE

PLANNING, ELIGIBILITY FOR CONNECTION AND CONNECTION PROCEDURE IN EMBEDDED GENERATION

Use of Microgrids and DERs for black start and islanding operation

FRAUNHOFER INSTITUTE FOR CHEMICAL TECHNOLOGY ICT REDOX-FLOW BATTERY

Control strategies and electronics for PEM fuel cells

ABB Microgrids and Energy Storage. Nathan Adams, Director, Technology and Business Development

Grid Services From Plug-In Hybrid Electric Vehicles: A Key To Economic Viability?

Technical Guide No. 7. Dimensioning of a Drive system

Hybrid Grid and Energy Storage: A Step towards Adaptation, Application and Development

Japanese Power Market Regulation Large Scale Battery Storage as a Solution for Challenges in Ancillary Services

Lead Acid Batteries Modeling and Performance Analysis of BESS in Distributed Generation

Sustainable Energy Mod.1: Fuel Cells & Distributed Generation Systems

Design and experimental tests of control strategies for active hybrid fuel cell/battery power sources

Model-Based Investigation of Vehicle Electrical Energy Storage Systems

Co-Ordination Control and Analysis of Wind/Fuel Cell based Hybrid Micro-Grid using MATLAB/Simulink in Grid Connected Mode

Lithium Ion Battery Energy Storage for Microgrids

Stand alone PEM Fuel Cell Feeding Non-Linear, Linear and PMSM Load through HVDC Link

Volkswagen. World Premiere. Golf SportWagen HyMotion Research vehicle with hydrogen fuel cell. Los Angeles Auto Show November 2014

2009 Wind-Diesel Workshop. Microgrid Control System Technology GE Digital Energy, Markham Ontario

CHAPTER 5 FREQUENCY STABILITY OF POWER SYSTEM USING MICROGRID WITH ENERGY STORAGE

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Model Comparison with Experiments. 341 N. Science Park Road State College, PA U.S.A.

Product Overview. 1.0 About VRB-ESS. 2.0 System Description. MW-Class VRB-ESS

4 What We Know About Fuel Cells

DYNAMIC MODELING RESIDENTIAL DATA AND APPLICATION

Farhana Shirin Lina BSC.(Electrical and Electronic) Memorial University of Newfoundland & Labrador

Performance Simulation of Energy Storage Technologies for Renewable Energy Integration

ECEN 667 Power System Stability Lecture 19: Load Models

ME 466 PERFORMANCE OF ROAD VEHICLES 2016 Spring Homework 3 Assigned on Due date:

Implementation of a Wide Area Monitoring System (WAMS) for Austria's Power Grid

Available online at ScienceDirect. Procedia Engineering 170 (2017 )

Corresponding Author, Dept. of Mechanical & Automotive Engineering, Kongju National University, South Korea

To Shift or not to Shift?

Wind Turbine Emulation Experiment

Modeling and validation of a flywheel energy storage lab-setup

Document Code: 1 (8) Issuing date: Status:

Power Conditioning of Microgrids and Co-Generation Systems

Possibilities of Distributed Generation Simulations Using by MATLAB

Smart Control of Low Voltage Grids

Islanding of 24-bus IEEE Reliability Test System

HYBRID ENERGY STORAGE SOLUTIONS. ESS Model = f (ESS technology, Required service) Ø Inputs. Ø Outputs

RESEARCH PROJECT VERBUNDNETZSTABIL

SECTOR COUPLING AND HYDROGEN IN THE MARINE INDUSTRY AND PORTS CHBC OCT 2018

Asia Pacific Research Initiative for Sustainable Energy Systems 2012 (APRISES12)

Mobile Air Conditioning (MAC)

MULTI-STAGE ENERGY STORAGE SYSTEM COMBINED BATTERY & FLYWHEEL STORAGE PLATFORM FOR RENEWABLES INTEGRATION

Polarization Curve/VI Characteristics of Fuel Cell using MATLAB/Simulink

Dynamic Modeling and Control of a Proton Exchange Membrane Fuel Cell as a Distributed Generator

Grid Impacts of Variable Generation at High Penetration Levels

4th European PV-Hybrid and Mini-Grid Conference, Glyfada, Greece, May 2008

Design and evaluate vehicle architectures to reach the best trade-off between performance, range and comfort. Unrestricted.

Experience the Hybrid Drive

SEVILLA, APRIL Microgeneration and Microgrids (modeling, islanding operation, black start, multi-microgrids) J. Peças Lopes Power Systems Unit

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Agenda. 1. EDP Group & HC Energía. 2. Conventional approach to storage: price arbitrage. 3. New approach: grid services and reserves

Implementation of FC-TCR for Reactive Power Control

Improvement the Possibilities of Capacitive Energy Storage in Metro Railcar by Simulation

Peak power shaving using Vanadium Redox Flow Battery for large scale grid connected Solar PV power system

Grid Stability Analysis for High Penetration Solar Photovoltaics

GRANT AGREEMENT

NaS (sodium sulfura) battery modelling

Hydrogen Fuel Cell and KERS Technologies For Powering Urban Bus With Zero Emission Energy Cycle

Comparative experimental study of the performance of two different types of HTPEM MEAs

Statcom Operation for Wind Power Generator with Improved Transient Stability

SIRFN Capability Summary European Distributed Energy Resources Laboratories (DERlab) e. V.

PSO project EaseWind Enhanced ancillary services from Wind Power Plants. Anca D. Hansen DTU Wind Energy

Renewable Energy for Minnesota. Progress in Fuel Cell Research at CPG

Transcription:

Asia Pacific Research Initiative for Sustainable Energy Systems 2011 (APRISES11) Office of Naval Research Grant Award Number N0014-12-1-0496 Hydrogen Energy System Simulation Model for Grid Management Applications Task 3.5 Prepared For Hawaii Natural Energy Institute Prepared By Dr. Mebs Virji Hydrogen Renewable Energy System Analysis June 2017

Hydrogen Energy System Simulation Model for Grid Management Applications Progress Report Document prepared for HNEI by Dr. Mebs Virji 30 th June 2017

Hydrogen Energy System Simulation Model for Grid Management Applications Progress Report 30 June 2017 This report documents the progress in developing a dynamic simulation model for conducting analysis of the HNEI Hydrogen Energy System that is being evaluated as a potential tool to support the use of an electrolyzer to provide ancillary services to the grid. Objectives The main objectives of the Hydrogen Energy System (HES) Simulation Model: Ø Develop electrolyzer, battery energy storage system (BESS), renewable power sources and utility grid models using measured performance data of a hydrogen energy system deployed on the Island of Hawaii; Ø Develop, evaluate and optimize a grid management control algorithm under a wide range of grid operating conditions; Ø Characterize the performance of an HES system under realistic dynamic or cyclic load profiles; Ø Study the trade-offs between different sizes of electrolyzer systems (kw to MW) and storage systems required for optimal grid management strategies incorporating different renewable power sources; and Ø Evaluate the performance of a hybrid electrolyzer system (electrolyzer + BESS) using different grid management control algorithms. Grid Management HES Simulation: Ø The HES simulation is being developed in the Matlab and Simulink Environment; Ø The HES simulation will have an HES model that will include the following: o Electrolyzer system model; o Grid power system model; o BESS model; o Control algorithms model; and o Different renewable power source models. Ø HES simulation will be used to evaluate the hybrid electrolyzer-bess system under different grid management control algorithms as functions of frequency deviations. Hydrogen Energy System Model Electrolyzer Model A PEM electrolyzer model has been developed to determine the cell voltage of an electrolyzer cell as a function of supply current and other operating parameters such as temperature, pressure and water flow rate. Using this model, a performance characteristic (V-I curve) of the electrolyzer can be determined and can be used to calculate the electrical power required by the electrolyzer for the production of hydrogen at different

currents or current densities. The required cell voltage of a PEM electrolyzer can be estimated by the following equation: V cell = V o + η act, a +η act, c +η ohmic +η con Where, V o is the equilibrium voltage; η act, a and η act, c are activation over-potentials at anode and cathode, respectively; η ohmic is the ohmic over-potential across the proton exchange membrane; and η con is the concentration over-potential due to bubbling of exiting oxygen which could limit the permeation of water to the anode especially at high current densities. This equation calculates the cell voltage as a function of many operating parameters of the electrolyzer cell, anode and cathode electrodes and membrane properties. Some of the main parameters which are employed in the model to predict the performance of the PEM electrolyzer are: a. Current, Pressure and Temperature; b. Anode and cathode exchange current density; c. Membrane thickness and hydration; and d. Limiting current density. The electrolyzer cell model was implemented in the Matlab/Simulink environment to study the effect of varying these parameters on the cell voltage of the PEM electrolyzer. The Proton C30 electrolyzer operating conditions were used in the model and model results were compared and validated using measured performance data from the Proton C30 electrolyzer. However, more specific measurement will be needed, especially at lower currents, to fully validate the model so as to predict accurately the performance of the Proton C30 electrolyzer.

Results from the PEM Electrolyzer Model: Figure 1: Electrolyzer Pressure Figure 2: Electrolyzer Temperature

Figure 3: Anode Exchange Current Density Figure 4: Cathode Exchange Current Density

Figure 5: Membrane Thickness Variation Figure 6: Membrane Hydration Variation

Figure 7: H 2 Flow Rate & Efficiencies of C30 System Figure 8: AC & DC Power of C30 System Electrolyzer System Model in Simulink The electrolyzer system was designed and developed in the Matlab/Simulink environment and it contains model blocks for current control, thermal control, electrolyzer cell and stack model, cathode model for ramping the system pressure and

buffer tank model for ramping the product pressure. Figure 9 shows the overall electrolyzer system as implemented in the Matlab/Simulink environment. Figure 9: Electrolyzer System Model in the Matlab/Simulink Environment The thermal, current, hydrogen flow-rate and pressure controls and time constants were designed and tuned to simulate the dynamic ramping characteristics of the Proton C30 electrolyzer during the startup (powering up) process, safety check and venting process, and normal operational process. Figures 10 to 14 show the following: Figure 10: Figure 11: Figure 12: Figure 13: Figure 14: Block for the electrolyzer cell and stack model. Block for current and thermal control model for the startup, venting and normal operations + current control during the normal operations. Block for the overall system pressure model for the startup, venting and normal operations. Block for the system pressure control model during the normal operation. Block for the buffer tank pressure control model.

Figure 10: Electrolyzer cell and stack model block Inside the block Figure 11: Current and thermal control model block Figure 12: Overall system pressure control model

Figure 13: System pressure control model block during the normal operation Figure 14: Buffer tank pressure control model block Results from the PEM Electrolyzer System Model: The electrolyzer system simulation was run to generate current, system and product pressures, hydrogen flow rate and temperature characteristic profiles for the startup, venting and normal operational processes of the system. These results profiles were then compared to the measured data from the Proton C30 electrolyzer system. Figure 15 shows the simulations results compared to the data from the Proton C30 electrolyzer system for the H 2 Flow Rate, System Pressure, Product Pressure and stack current while Figure 16 shows the simulated temperature results compared with measured data from the electrolyzer system. The results show that the control parameters and the time constants

are very well tuned to accurately estimate the operational characteristics of the actual Proton C30 electrolyzer system operations. Figure 15: Simulated results compared with data from the Proton C30 Electrolyzer Figure 16: Simulated temperature result compared with data from the Proton C30 Electrolyzer

450 bar Compressor Cycle Model: The hydrogen compressor ramp rate model was updated in the buffer tank pressure model to include the cycle for filling up the buffer tank with hydrogen and subsequent compression of the hydrogen to 450 bar by the compressor. A pulse generator was used to initiate the starting and stopping of the compressor as programed in the PLC of the actual Hydrogen Energy System installed at NELHA on the Big Island. The buffer tank takes about 13 minutes to fill to about 30 bar by hydrogen from the electrolyzer while the compressor takes about 20 minutes to compress the hydrogen to 450 bar into the tube trailer tanks. The model was validated using measured data from the Proton C30 electrolyzer. Figure 17 shows the implementation of the compressor cycle model into the buffer tank model of the HES Simulink overall model. Figure 18 shows the results from the model which are compared to the measured data from the C30 Electrolyzer system database. Inside the block Figure 17: Compressor cycle model inside the buffer tank block

Figure 18: Simulated compressor cycle results compared with data from the Proton C30 electrolyzer Grid Power System Model: The grid power system model includes a dynamic frequency model with primarycontrolled power plant. Figure 19 shows the model of the grid power system in the Simulink environment. The main control objective of the grid power system model is to maintain the balance between the electric power produced by the generators and the power consumed by the loads, including the network losses, at all time instants. If this balance is not kept, this will lead to frequency deviations that if too large will have serious impacts on grid system operation. The dynamic frequency model (DFM) based on the swing equation [Δf= (f 0 /2HS B ) (P m P e )] for the set of synchronous machines (generators), is used to determine the change in average system frequency (Δf) and is defined as the center of inertia of the system. This algorithm is valid for reasonable frequency deviations due to imbalances between the instantaneous generation and consumption of electric power which has an accelerating or decelerating effect on the synchronous machines. The DFM also includes aggregated system loads (1/D F ) and large rotating motor loads (W 0 ) which are depending directly on the frequency. These loads are evidently present in a real power system and have a stabilizing effect on the system frequency.

Primary Controlled Power Plant Figure 19: Grid Power System Simulink block with dynamic frequency model with the primary controlled power plant. The values of W 0 and D F are obviously highly dependent on the structure of the load and can be variable over time. Especially, W 0 is only a factor in power systems with large industrial consumers running heavy rotating machines. The constant D F has typical values such that the variation of the load is equal to 0-2% per % of frequency variation. The primary controlled power plant is also part of the grid power system model as shown in Figure 19. This power plant model includes a primary frequency controller also known as the speed regulation of the governor or Speed Governor and Turbine Dynamics. The primary control refers to control actions that are done locally (on the power plant level) based on the set points for frequency and power. The actual values of these can be measured locally, and deviations from the set values result in a signal that will influence the valves, gates, servos, etc. The purpose of the speed governor is to bring the frequency back to acceptable values. However, since the controller is implemented on a local level, the controller cannot have an integral component, but only proportional control which will always have some unavoidable frequency control error. The turbine dynamics also play an important role in the overall dynamic response of the system. The delay between the different parts of the steam path in the turbine system is usually modeled by a number of first order filters depending on the number of turbines (high to intermediate to low pressure ones) and re-heaters used in the system. Typical values of the time constant of the delay between the control valves and the high-pressure turbine is 0.1 0.4 seconds. If a re-heater is installed, the time delay is larger typically 4 11 seconds. The time constant of the delay between the intermediate and low pressure turbines is in the order of about 0.3 0.6 second. For simplicity and for initial investigation, only one first order filter of Tt = 0.3 second is used in the grid power

system model. However, the model can be customized to different configurations of power systems (gas, hydro, etc.) used on the Island of Hawaii. To understand the behavior and dynamic characteristic of the grid power system model, different step changes in supply and load power signals were input into the model. The simulation was run for 300 seconds and the following parameters were used in the time domain simulation: Total System Rating, S B = 4000 MW Total system inertia constant, H.= 5 sec Nominal Frequency, f o = 60 Hz Frequency dependent load o constant, D F = (f o /S B ) = 0 Hz/MW (Zero for this investigation) Rotating Mass load o constant, W 0 = 0 MW/Hz (Zero for this investigation) Speed Governor (proportional control) o constant, R = (4/100)*(f o /S B ) = 6e -04 Hz/MW Turbine Time constant, T t = 0.3 sec Input Power Signals: o The plot below shows the step change in Solar Power, System Load and Electrolyzer Load. The generator power and wind power had no step change in power during the 300 second simulation:

1 0-1 Generator Power H2ES_Sim_170123/Signal Builder : PS Signals 400 Solar Power 200 0 1 0-1 400 200 0 200 100 0 Wind Power System Load Electroyzer Load 0 50 100 150 200 250 300 Time (sec) Sola r Pow Electrolyzer 100% ON Solar Power OFF System Load OFF System Load ON Electrolyzer 40% ON System Balanced Electrolyzer 40% ON Electrolyzer 40% ON System Load ON Solar Power Switching ON Turbine Power Compensating for switching loads ON & OFF Figure 20: Simulated results from the grid power system model for different step change input power signals

Figure 20 shows the frequency (top) and power (bottom) response of grid power system model to step changes in the system load, electrolyzer load and solar power over the 300 second simulation. For the first 30 sec the system is balanced and there is no change in frequency remaining constant at 60 Hz. After that the power system responds to the change in system and 40% electrolyzer loads. The effect of the primary frequency controller is also observed whereby the controller is increasing the turbine power to compensate for increase in load demand. When solar power is available at the 80 th second, the frequency increases to above 60 Hz and that would give an indication to our grid management control algorithm (yet to be designed) to ramp up the electrolyzer power to produce more hydrogen since there is excess power available. This action is done manually in this investigation, as the electrolyzer demand load is increased to 100%. Once the solar power is no longer available and the electrolyzer is ramped down (may be due to full storage tanks), the frequency returns to 60 Hz and the system is now in a balanced state once again as seen in Figure 20 after the 150 second time period. Next Steps The next steps in the development of the HES Simulation are the battery model, grid management control algorithm and the HES Simulation system studies using realistic load profiles under different operational and control strategies.