INSTRUCTION MANUAL TOP SETTING WADING RODS MODEL TSR

Similar documents
INSTRUCTION MANUAL OSS-B1 UNIVERSAL CURRENT METER

INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL HS305

HyQuest Solutions Pty Ltd

U U15-3 KUBOTA ZERO TAIL SWING COMPACT EXCAVATOR. Designed from the inside out to handle the tough jobs that larger machines can t even get to.

U17-3 KUBOTA ZERO TAIL SWING COMPACT EXCAVATOR

BHS1.com Battery & Charger Stands Battery Roller Stands

SYSTEM STANDS MODEL SERIES FEATURES & BENEFITS

MANUAL LIFTER TROLLEY INSTRUCTION MANUAL

KX KX91-3 SUPER SERIES MK 2

Vetlab CombiSpin Centrifuge

HOUSTON OILFIELD EQUIPMENT 9669 PORT ERROLL RD. HOUSTON, TX PHONE: (713) FAX: (713)

KX KX161-3 SUPER SERIES

KX KX121-3 SUPER SERIES

Setting Up & Operating Instructions

Performance Tech Support 1(800)

PLEASE READ THESE INSTRUCTIONSFULLY BEFORE STARTING TO ASSEMBLE YOUR DIDICAR PLEASE PAY SPECIAL ATTENTION TO THE NOTES AND HINTS

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS

SEATING INSTRUCTIONS. Trooper

SAFETY. Read and understand all safety precautions and instructions before installing this product.

ABSOLUTE EQUIPMENT PTY LTD

BHS1.com Battery & Charger Stands Battery Roller Stands

INSTALLATION INSTRUCTIONS

Torque Wrenches

OCTOPUS SERVICE PROCEDURE - SP007 REV NEW 15-FEB-2008

ABSOLUTE EQUIPMENT PTY LTD

POSITIVE DISPLACEMENT FLOWMETERS

1200W CaR PoliSheR en RS4900

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

KUBOTA ZERO TAIL SWING COMPACT EXCAVATOR U17-3

SERVICE MANUAL. Coolant Level - Sight Glass. Air Cleaner Restriction Indicator

SD Bendix ET-2 Electronic Treadle DESCRIPTION OPERATION

20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT

PROCESS ECONOMICS PROGRAM

SISU DP-330 DRIVE GEAR. Maintenance Manual

Oil Seal Catalogue. Ashley Power Ltd Ashley Road Parkstone Poole Dorset, BH14 0AQ. P1

SILI PUMP, Your reliable one-stop supplier of marine pumps.

POLARIS 4500 HD WINCH KIT

EXTERNAL DIMENSIONS. L Length W Width D Depth EXTERNAL DIMENSIONS. L Length W Width D Depth

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

LCD EWP /FAN DIGITAL CONTROLLER Installation Instructions

MC2500. Installation and Operation Manual

Inverted High Pressure Fluid Filters

Preventative Maintenance. The key to accuracy, reliability and longevity for your first-class analysers from MEP Instruments

BAC, BAF, BAH Central Station Air Handlers

Operation and Maintenance Manual

Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve

Kale Marketing, Inc. SPX Family. SPX3150 and SPX

Swirl Wheelbase and Interface Workshop Manual.doc

MAGNETO REPLACEMENT. Pre-Unit Twin Cylinder Motorcycles. ELECTRONIC IGNITION SYSTEM For 4 Stroke. With 12 VOLT Electrics, POS/ NEG Ground

FACF AUTOMATIC CAPSULE FILLER SERIES USER MANUAL

Rhino-Rack Rocky Mount Bike Carrier (RBC050)

HYDRAULIC BENCH PRESS 50,000kg

1. Single-speed bicycle (SSB) lower fork legs... Page 3 2. Multi-speed bicycle (MSB) lower fork legs... Page 4

Article number Last change Valid from REAL 9000 PLUS ADULT The custom built workingchair

MONOBLOCK VALVES CATALOGUE

Rhino-Rack Hybrid Bike Carrier (RBC050)

H Low Torque Impact Wrench

BRAKES. Section III REAR AXLE DATA AND SPECIFICATIONS HAND BRAKE CHRYSLER SERVICE MANUAL BRAKES 17

Introduction Date: October 2007 Pt No INSTRUCTION KIT JOINER RF 1 KIT COMPONENTS

PVC Casing Cutter - Single Cutting Wheel (SCW) Sizes & , Operators Manual

TECHNICAL INFORMATION

User Manual. Studio Rail. Size Version

UNIVERSAL SOLAR SYSTEM (USS) USER MANUAL. For Millennium Low Power Gas Detectors or other continuous loads less than 0.

VECTRIX VX-2 SERVICE MANUAL. Version 1.0/May 2011 VECTRIX, LLC

STAUFF. Local Solutions for Individual Customers Worldwide. Stauff Tube Clean System. Pipe, Tube & Hose Cleaning System

TANK RISER SUSPENSION SYSTEM CONCEPTUAL DESIGN (U)

Acoustic Door Closer Instructions

U U35-3 SUPER SERIES MK 2

INSTALLATION GUIDE 3G7047 & 3G7009A SELF SUPPORTING GUN RACK FOR FORD UTILITY INTERCEPTOR. pro-gard.com STRONG RELIABLE SECURE

SAFETY. Read and understand all safety precautions and instructions before installing this product.

Welker Probe Instrument Regulator with Liquid Eliminator Cartridge

50 TONNE HYDRAULIC PRESS MODEL NO: CSA50FP

Operation Instructions

INSTALLATION MANUAL. Thunderstone Manufacturing LLC 3400 West O Street Lincoln, NE (Fax)

THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions

PNEUMATIC 180 ANGULAR GRIPPER

AMIAD Automatic Filters

INSTRUCTION MANUAL. Handy Polaris

Your partner for highest precision. distributed by Tel

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

INSTALLATION AND SET-UP

FLP-2492/KLP-4492 Impeller Flowmeter

Probe Driver for Visual Plus 3. (c) , Saryna Technologies LLC/Advanced Inspection Technology

1008 thru 3030 sizes. C Hub Dia. Short No. Std. Hex Capacity. Key u. F Wrench D Steel Qty. Size Install.

DOOR KIT P/N , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

FitBike 1 DBT. Instructions / Manual / Maintenance

TA-2 RANGE OF THERMAL ANEMOMETERS

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

KST-A01 LINEAR ACTUATOR

FILLING MACHINES SINGLE HEAD

Simplifying Inspection MAGNETIC PARTICLE TESTING ACCESSORIES

Dial and Electronic. Indicators Gauges

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

PET UNIT DOSE CABINET

STRUT SPRING COMPRESSOR

Southwest Windpower Instruction Sheet AIR-X Circuit Replacement Kit

MP and MP Diaphragm and Seal Kits for MP8000 Series Actuators

Tri-roll External Thread Gage

2" (50MM) ROTARY HAMMER

Transcription:

INSTRUCTION MANUAL TOP SETTING WADING RODS MODEL TSR QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD 48-50 Scrivener St, Warwick Farm, NSW 2170, AUSTRALIA Phone: +61 2 9601 2022 Fax: +61 2 9602 6971 Email: sales@hyquestsolutions.com.au Web: www.hyquestsolutions.com.au TOP SET WADING RODS-MODEL TSR ISSUE 4:1/6/2016 1

CONTENTS I HYDROLOGICAL SERVICES STANDARD WARRANTY TERMS... ERROR! BOOKMARK NOT DEFINED. II INSTRUCTION FOR SEPARATION OF SPLIT TOP SET ROD... 3 III GENERAL... 5 VI UNPACKING... 5 V OPERATION... 6 Diagram 1... 6 IMPERIAL RODS... 8 METRIC RODS... 13 VI MAINTENANCE... 18 VII PART LIST... 18 VIII APPENDIX (A) OSS-B1 INSTALLATION TO TSR... 19 TOP SET WADING RODS-MODEL TSR ISSUE 4:1/6/2016 2

TOP SETTING WADING RODS MODEL TSR I INSTRUCTION FOR SEPARATION OF SPLIT TOP SET ROD STEP 1: ALIGN 19 WITH 0 FOR METRIC (ALIGN 4 WITH 0 FOR IMPERIAL) TOP SET WADING RODS-MODEL TSR ISSUE 4:1/6/2016 3

STEP 2: UNSCREW THE SUSPENSION ROD AS SHOWN STEP 3: UNSCREW THE HEX ROD AS SHOWN TOP SET WADING RODS-MODEL TSR ISSUE 4:1/6/2016 4

NOTE: To re-assemble reverse order from Step 3 to Step 1 II GENERAL The model TSR Top Setting Wading Rods were developed to simplify the task of the hydrographer while carrying out gauging of small streams. The TSR shall only be used in shallow streams, where it is safe for the hydrographer to carry out gaugings while wading. The TSR is available in Metric and Imperial models and each model is available in lengths of 4 feet (1200mm), 6 feet (1800mm) and 8 feet (2400mm) The device: ensures the stable placement of the rod on the stream bed. allows the depth of the stream to be measured. enables the hydrographer to precisely position the current meter at 0.2, 0.4, 0.6 and 0.8 of water depth without removing the rod from the stream bed. allows the direct connection of the current meter and pulse counter without external cables. The Top Setting Wading Rods are manufactured from durable materials selected to meet the environmental conditions in the field. III UNPACKING Remove the packing material from the TSR carry case This product has been inspected to ensure compliance with your purchase order and has been appropriately packed to ensure the safe transit to your warehouse, however a thorough inspection of the product should be carried out upon receipt to confirm compliance and to identify any damage that may have occurred during transit. Any short supply or damage should be reported to Hydrological Services Pty Ltd within seven days of receipt of the product. The Hydrological Services Model TSR Top Setting Wading Rods have been pre-assembled in the factory and are ready for service. This product does NOT include a pulse counter or current meter unless specifically requested in the purchase order. TOP SET WADING RODS-MODEL TSR ISSUE 4:1/6/2016 5

IV OPERATION Diagram 1 6

Preparation refer to Diagram 1 above HyQuest Solutions Pty Ltd Position the tail fin on the METER MOUNTING (Item 4) and secure with screw. Position the appropriate current meter, complete with fan on the METER MOUNTING (Item 4) and secure with screw. Connect CABLE (Item 8) to current meter. Position the pulse counter (current meter counter) on PIN (Item 9) and connect lead to CONTACT (Item 7). Depress TRIGGER (Item 6) the SUSPENSION ROD (Item 5), complete with the current meter, to slide within the HAND GRIP BODY (Item 3). Ensure that the suspension rod slides smoothly for its full length. Do not permit the current meter to fall to the foot as damage to the meter may occur. Power up the pulse counter (current meter counter) and carry out function test as per manufacturer s instructions. Rotate the current meter fan to generate pulses then check that the pulses are being received by the pulse counter. The device is now ready for operation. An appropriate stream cross section should have been previously selected and set up for gauging. Operation Place the Top Setting Wading Rod vertically in the stream at the appropriate point in the cross section, ensuring that the base plate is stable and that the meter is directed into the flow. Read off the depth of stream on the GRADUATED ROD (Item 2). Top Setting Wading Rods are available in both Metric and Imperial models. The following pages shows the use of both models in detail. Relationship between the GRADUATED ROD (Item 2) & the SUSPENSION ROD (Item 5) The GRADUATED ROD (Item 2) is designed for measurement of individual soundings across the stream section. This rod is graduated with markings every 0.1 feet for the imperial TSR and 20 millimetres for the metric TSR. NB: The graduations on the SUSPENSION ROD (Item 5) and VERNIER SCALE (Item 3) are NOT to be used for direct measurement of soundings. These graduations on these Items have been designed for accurate setting of the current meter to the required depth of observation. 7

Imperial Rods The GRADUATED ROD (Item 2) is graduated in 0.1 feet. To assist in the reading, the rod is marked with a triple groove at full feet graduations, double groove at half feet graduations and single groove at 0.1 feet graduations. With respect to the GRADUATED ROD (Item 2), the stream bed is the zero reference. The current meter can be readily set at 0.2, 0.4, 0.6 and 0.8 of the sounding by aligning the appropriate graduation on the SUSPENSION ROD (Item 5) with the appropriate graduation on the VERNIER SCALE (Item 3). When a multiplier is applied to the measured sounding (i.e. the reading taken from the GRADUATED ROD (Item 2), the correct depth of observation for a current meter velocity measurement is calculated. The table below summarises the various multipliers to be used for each required depth of observation: MULTIPLIER TABLE Depth of Observation 0.2d 0.4d 0.6d 0.8d Multiplier Used 2.0 1.5 1.0 0.5 Where d = sounding taken from GRADUATED ROD (Item 2) Refer to the following examples. 8

Example 1 - The sounding has been read at 2.0 feet on the GRADUATED ROD (Item 2 ). Setting at 0.2d 1. From the table above, the calculated reading is 4 (i.e. multiplier 2.0 * sounding 2 ) 2. To set the current meter at 0.2 of the 2.0 feet sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 4 on the suspension rod is in line with graduation 0 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 1.6 feet on the GRADUATED ROD (i.e.: 0.2 of sounding) Setting at 0.4d 1. From the table above, the calculated reading is 3 (i.e. multiplier 1.5 * sounding 2 ) 2. To set the current meter at 0.4 of the 2.0 feet sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 3 on the suspension rod is in line with graduation 0 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 1.2 feet on the GRADUATED ROD (0.4 of sounding) 9

Setting at 0.6d 1. From the table above, the calculated reading is 2 (i.e. multiplier 1.0 * sounding 2 ) 2. To set the current meter at 0.6 of the 2.0 feet sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 2 on the suspension rod is in line with graduation 0 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 0.8 feet on the GRADUATED ROD (0.6 of sounding) Setting at 0.8d 1. From the table above, the calculated reading is 1 (i.e. multiplier 0.5 * sounding 2 ) 2. To set the current meter at 0.8 of the 2.0 feet sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 2 on the suspension rod is in line with graduation 0 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 0.4 feet on the GRADUATED ROD (0.8 of sounding) 10

Example 2 The sounding has been read at 2.2 feet on the GRADUATION ROD (Item 2) Setting at 0.2d 1. From the table above, the calculated reading is 4.4 (i.e. multiplier 2.0 * sounding 2.2 ) 2. To set the current meter at 0.2 of the 2.2 feet sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 4 on the suspension rod is in line with graduation 4 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 1.76 feet on the GRADUATED ROD (0.2 of sounding) Setting at 0.4d 1. From the table above, the calculated reading is 3.3 (i.e. multiplier 1.5 * sounding 2.2 ) 2. To set the current meter at 0.4 of the 2.2 feet sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 3 on the suspension rod is in line with graduation 3 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 1.32 feet on the GRADUATED ROD (0.4 of sounding) 11

Setting at 0.6d 1. From the table above, the calculated reading is 2.2 (i.e. multiplier 1.0 * sounding 2.2 ) 2. To set the current meter at 0.6 of the 2.2 feet sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 2 on the suspension rod is in line with graduation 2 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 0.88 feet on the graduated rod (0.6 of sounding) Setting at 0.8d 1. From the table above, the calculated reading is 1.1 (i.e. multiplier 0.5 * sounding 2.2 ) 2. To set the current meter at 0.8 of the 2.2 feet sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 1 on the suspension rod is in line with graduation 1 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 0.44 feet on the GRADUATED ROD (0.8 of sounding) 12

Metric Rods The rod is graduated in 20 millimetres graduations. To assist in the reading, the rod is marked with a triple groove at 500 millimetre graduations, double groove at 100 millimetre graduations and single groove at 20 millimetre graduations. With respect to the GRADUATED ROD (Item 2), the stream bed is the zero reference. The current meter can be readily set at 0.2, 0.4, 0.6 and 0.8 of the sounding by aligning the appropriate graduation on the SUSPENSION ROD (Item5) with the appropriate graduation on the VERNIER SCALE (Item 3). The correct depth of observation for current meter velocity measurement, is based on a multiplier, which when applied to the measured sounding (i.e. that taken from the GRADUATED ROD (Item 2) requires the application of a multiplier to calculate the correct setting to be used on the SUSPENSION ROD (Item 5). The table below summarises the various multiplier to be used, based on required depth of observation: MULTIPLIER TABLE Depth of Observation 0.2d 0.4d 0.6d 0.8d Multiplier Used 2.0 1.5 1.0 0.5 Where d = sounding taken from GRADUATED ROD (Item 2) Refer to the following examples. 13

Example 1 The sounding has been read at 5 decimetres (500mm) on the GRADUATION ROD (Item 2). Setting at 0.2d 1. From the table above, the calculated reading is 10 (i.e. multiplier 2.0 * sounding 5 ) 2. To set the current meter at 0.2 of the 5 decimetre sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 10 on the suspension rod is in line with graduation 0 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 4.0 decimetres (i.e. 400mm) on the GRADUATED ROD (0.2 of sounding) Setting at 0.4d 1. From the table above, the calculated reading is 7.5 (i.e. multiplier 1.5 * sounding 5 ) 2. To set the current meter at 0.4 of the 5 decimetre sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 7 on the suspension rod is in line with graduation 5 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 3.0 decimetres (i.e. 300mm) on the GRADUATED ROD (0.4 of sounding) 14

Setting at 0.6d 1. From the table above, the calculated reading is 5 (i.e. multiplier 1.0 * sounding 5 ) 2. To set the current meter at 0.6 of the 5 decimetre sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 5 on the suspension rod is in line with graduation 0 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 2.0 decimetres (200mm) on the graduated rod (0.6 of sounding) Setting at 0.8d 1. From the table above, the calculated reading is 2.5 (i.e. multiplier 0.5 * sounding 5 ) 2. To set the current meter at 0.8 of the 5 decimetre sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 2 on the suspension rod is in line with graduation 5 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 1.0 decimetres (100mm) on the GRADUATED ROD (0.8 of sounding) 15

Example 2 The sounding has been read at 5.2 decimetres or 520mm on the GRADUATION ROD (Item 2) Setting at 0.2d 1. From the table above, the calculated reading is 10.4 (i.e. multiplier 2.0 * sounding 5.2 ) 2. To set the current meter at 0.2 of the 5.2 decimetre sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 10 on the suspension rod is in line with graduation 4 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 4.2 decimetres (420mm) on the GRADUATED ROD (0.2 of sounding) Setting at 0.4d 1. From the table above, the calculated reading is 7.8 (i.e. multiplier 1.5 * sounding 5.2 ) 2. To set the current meter at 0.4 of the 5.2 decimetre sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 7 on the suspension rod is in line with graduation 8 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 3.1 decimetres (310mm) on the GRADUATED ROD (0.4 of sounding) 16

Setting at 0.6d 1. From the table above, the calculated reading is 5.2 (i.e. multiplier 1.0 * sounding 5.2 ) 2. To set the current meter at 0.6 of the 5.2 decimetre sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 5 on the suspension rod is in line with graduation 2 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 2.1 decimetres (210mm) on the graduated rod (0.6 of sounding) Setting at 0.8d 1. From the table above, the calculated reading is 2.6 (i.e. multiplier 0.5 * sounding 5.2 ) 2. To set the current meter at 0.8 of the 5.2 decimetre sounding, depress the TRIGGER (Item 6) and slide the SUSPENSION ROD (Item 5) until the graduation mark 2 on the suspension rod is in line with graduation 6 on the VERNIER SCALE (Item 3). 4. This will position the current meter at 1.1 decimetres (110mm) on the GRADUATED ROD (0.8 of sounding) 17

V MAINTENANCE Because of the excellent durability of the Top Setting Wading Rods it is only necessary to clean and thoroughly dry the device after use prior to packing away. This is essential to remove any corrosive contaminants that may be present in the water being gauged. Periodically it may be necessary to remove oxidization from the electrical contact to ensure positive contact. This should be done with superfine emery paper or scotchbrite pad. VI PART LIST Refer to Diagram 1 ITEM NO. DESCRIPTION PART NO. 1 Foot Plate TSR07-02 2 Graduated Rod - 48 inch TSR07-01 Graduated Rod - 72 inch TSR07-02 Graduated Rod - 96 inch TSR07-03 Graduated Rod -1200 mm TSR07-04 Graduated Rod -1800 mm TSR07-05 Graduated Rod -2400 mm TSR07-06 3 Hand Grip Body - Imperial TSR01-01 Hand Grip Body - Metric TSR01-04 4 Meter Mounting Price TSR05-01 Meter Mounting - HS OSS-PC1 TSR05-03 5 Suspension Rod - 48 inch TSR08-01 Suspension Rod - 72 inch TSR08-02 Suspension Rod - 96 inch TSR08-03 Suspension Rod -1200 mm TSR08-04 Suspension Rod -1800 mm TSR08-05 Suspension Rod -2400 mm TSR08-06 6 Trigger TSR03-01 7 Contact SC043-43 8 Cable TSR09 9 Contact Block TSR02-01 10 Counter Suspension Pin TSR02-02 11 Contact Body TSR04-01 12 Insulating Sleeve 1 TSR01-02 13 Insulating Sleeve 2 TST01-03 14 Insulating Washer TSR05-02 15 Carry Case - 48 inch TSR10 Carry Case - 72 inch TSR11 Carry Case - 96 inch TSR12 18

VII Appendix (A) OSS-B1 Installation to TSR Figure 1: Initial State Figure 2: Unscrew the Foot Plate 19

Figure 3: Loosen the Tail of the OSS-B1 body as shown Figure 4: Loop the cable as shown 20

Figure 5: Locate the pin in the OSS-B1 body slot & tighten the tail to the rod as shown Figure 6: Plug the Angle Plug (AP01) in place by pushing down firmly & Secure Clamp in place 21

Figure 7: Screw the Foot Plate back on as shown 22