OPERATING MANUAL PLS HVR 505 PACIFIC LASER SYSTEM S. The Professional Standard

Similar documents
OPERATING MANUAL PLS HVR 505

OPERATING MANUAL PLS HLE 1000 PACIFIC LASER SYSTEMS. The Professional Standard

Automatic Self-Leveling Rotary Laser FRE-202. Operating Manual

Self-Leveling Rotary Laser Level with GreenBrite Technology Model No Instruction Manual

EAGL 1-Touch Laser Level

888-9-LEVELS

IMEX 66R ROTATING LASERS

PLS PACIFIC LASER SYSTEMS OUR WARRANTY & SERVICE ASK YOUR DEALER TO DEMONSTRATE A PLS LASER TOOL. The Professional Standard

LL400. Spectra Precision Division 8261 State Route 235 Dayton, Ohio U.S.A Phone

EAGL 2000 & EAGL 3000S Laser Levels

031266_Umschlag_HV_301.qxd :36 Uhr Seite 1 HV301

H2, HV2R, HV2G Rotary Laser Levels

SAFETY AND CERTIFICATIONS

Owner s Guide ca4054 ca4554

Laser Receiver Model MCR3. Operator's Manual

CONTENTS. User Safety 2 Introduction and CX440 Accessories 3 CX440 Diagram 4 CX440 Keypad and Remote Control 5 Operating Instructions 6

Owner s Guide CA 4555

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Owner s Guide. ca5354

CONTENTS. Calibration Self Check & Technical Specifications 13 Care & Maintenance, Trouble Shooting 15 Warranty 16

PLS SLD. Laser Detector PACIFIC LASER SYSTEMS. For use with your PLS pulsed laser alignment tool. The Professional Standard

Self-Leveling Cross Line Laser

Owner s Guide. ca5154

Bio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications

CA 5054 Owner s Guide

Twelve Unit Rapid Charger

INSTALLATION & OWNER'S MANUAL

Instruction Manual. OEM Frameless Rear View Replacement Mirror Monitor with 7.2" Dual Display RVS Reverse With Confidence 1

MEASUREMENT FOUNDATION. Operating manual Line laser level ADA CUBE 3D

will result in death or serious injury. could result in death or serious injury. Indicates a hazardous situation which, if not avoided,

Owner s Guide CA 5055

Operating manual Line laser level ADA PHANTOM 2D

Single Unit Rapid Charger FOR RECHARGEABLE TWO-WAY RADIO BATTERIES

HIGH VOLTAGE PROVING UNIT

Owner s Guide. ca6154

KIT CONSISTS OF: FEATURES. S-Digit mini

CAUTION CONTENTS 5.0 WARRANTY

User Guide. Model Insulation Tester / Megohmmeter. Introduction

The PROFESSIONAL STANDARD

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Owner s Guide CARS & CA4B5

INSTRUCTION MANUAL PET Fax: (503)

WARNING. Laser light is extremely bright and can potentially cause permanent eye damage or interfere with critical operations if improperly used.

ca1153 Owner s Guide

OWNER S MANUAL. 16 Stand Fan Model: SF-16T07

LED-6200T 144 LED VARIABLE COLOR ON-CAMERA LIGHT USER MANUAL

Owner s Guide PR1BZ PR1BZLR

Please read and understand all precautions prior to use.

4-Hour. Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

Owner s Guide CA 1155

This manual covers the following model:

OUTDOOR TABLE TENNIS TABLE ASSEMBLY INSTRUCTIONS

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

TABLE OF CONTENTS NOTES. 1.0 Operating principle... 02

LED-6200T 144 LED VARIABLE COLOR ON-CAMERA LIGHT USER MANUAL

VFL-280. Visible Fault Locator. Operating Manual

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

P OWER CUBE PLEASE READ BEFORE OPERATING THIS EQUIPMENT. Powerful Universal Portable Charger T M

flexible infrared thermometer

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

Tension your belts at the speed of light!

Installation Manual DIAPHRAGM WELL TANK

Magnetic Torpedo Laser Level with Base Model No Instruction Manual

Owner s Guide CA 1055

MLS KICK-OFF TABLETOP SOCCER TABLE ASSEMBLY INSTRUCTIONS

Operator s Manual. Automatic Electric Jack Leveling. The leveling system shall only be operated under the following conditions:

High Capacity Battery Charger

Patient Lift Scale Indicator Owner s Manual

Tissue Master. User Manual

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

6. Electrical. 7. Settings. 8. Quick

NEW GEN OWNER S MANUAL

CAUTION 7.0 WARRANTY CONTENTS. 1.0 Overview... 2

Deluxe Hitch 3-Bike Rack Instructions for Part # BC-3581

Cable Length Meter INSTRUCTION MANUAL

44xx Estes-Cox Corp H Street, PO Box 227 Penrose, CO Made In Shantou, Guangdong, China

OWNER S MANUAL Please read and understand all precautions prior to use.

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

CRD610 Automatic Fitting Inserter

Operator s Manual. Light & Laser Sight. GripSense

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS. Version 1.0

Scale Feeder Manifold Water Filtration System Instruction Manual

Electronic Water Timer Instructions

TABLE OF CONTENTS 11.0 WARRANTY

Memory Foam Massaging Bath Pillow with Wireless Remote Control

Coating Thickness Gauges

Universal 8-Bay Charger. for AA/AAA/C/D/9 NiMH & NiCd Rechargeable Batteries. Owner's Manual

RJH-4/6046. Wireless 3.5 Channel Mega Helicopter. (Instruction Manual)

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

CRD600 Automatic Fitting Inserter

For technical questions and replacement parts, please call

Hydro-Park High-end Four Post Parking Lift PROFESSIONAL PARKING SOLUTION PROVIDER!

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.2

AUTO-BLiP. User Manual Ford Mustang INTELLIGENT DOWNSHIFTS. Version 1.2

HANDY GATE ASSEMBLY, INSTALLATION AND OPERATING INSTRUCTIONS

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

Transcription:

OPERATING MANUAL PLS HVR 505 PACIFIC LASER SYSTEM S The Professional Standard

TABLE OF CONTENTS INTRODUCTION Introduction...Page 1 Safety Information...Page 2 Batteries...Page 3 Keypad...Page 4 Operation...Page 5 Functions...Page 6 Applications...Page 7 Remote Control...Page 8 Checking Calibration...Page 9 Specifications...Page 10 The PLS HVR 505 is a fully automatic, self-leveling laser used for height transfer and layout. The HVR 505 R is a traditional, visible red beam rotary laser used for both interior and exterior layout. The HVR 505 G is a highly visible, green beam rotary laser ideally used for interior layout. The HVR 505 G may also be used for exterior applications. The rechargeable PLS HVR 505 contains micro-controlled charging technology. CAUTION: DO NOT ATTEMPT TO CHARGE STANDARD ALKALINE BATTERIES OR WAR- RANTY WILL BE VOIDED. The PLS HVR 505 may be used in vertical and horizontal mode and has an up and down plumb beam. It also has an additional line marker (scanning) function and may be controlled by the PLS RC 505 remote control. The instrument is water resistant and may be used in the rain, if necessary. Unit may not be submerged in water. Warranty...Page 11 ROTATION HEAD UP BEAM EXIT WINDOWS PLS HVD Detector...Page 12 PLS HVD Operating Manual...Page 13 KEYBOARD DOWN BEAM RE-CHARGING PLUG HANDLE 1

SAFETY INSTRUCTIONS BATTERIES 2 Safety instructions Laser Safety The PLS HVR 505 R is a class II laser according to 21CFR1040. The PLS HVR 505 G is a Class IIIA laser. Follow the instructions on the warning labels which are shown in the following illustrations: CAUTION LASER RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS MAX OUTPUT POWER <1MW WAVELENGTH 635-670NM CLASS II LASER PRODUCT MAX OUTPUT POWER <1MW WAVELENGTH 635-670NM CLASS II LASER PRODUCT PLS HVR 505 R Laser Power: 635 nm <1mW Laser Class ll DANGER LASER RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS MAX OUTPUT POWER <1MW WAVELENGTH 635-670NM CLASS III A LASER PRODUCT PLS HVR 505 G LASER POWER: 532 NM <5MW LASER CLASS III PLS HVR 505 G Laser Power: 532 nm <5mW Laser Class lll Do not remove the attached warning labels. The manufacturer and its dealers are not liable for any defects and the consequences from this removal.! Attention! The internal laser sources comply with with laser classes II and III. Do not disassemble the instrument. In case of inappropriate repairs, laser radiation may arise in excess amounts of the marked labels and liability may be incurred if there is damage. In cases of inappropriate processing, malfunctions are possible without external visible damage. The unit charger should only be used indoors. DO NOT ATTEMPT TO CHARGE STANDARD ALKALINE BATTERIES. Attention: This instrument contains nickel-metal hydride batteries. Nickel-metal hydride batteries must be recycled or disposed of properly. WEEE-Reg.: DE23874031 The PLS HVR 505 uses rechargeable NIMH batteries. For on-board chargeable battery, insert the battery re-charger receptacle plug in the charging panel outlet of the battery cover pack. Insert converter's AC receptacle plug in an AC outlet and insert the converter's DC receptacle plug in the charging panel's DC outlet. When the charging lamp is on, charging is in process. ALKALINE BATTERY PACK NIMH RECHARGEABLE BATTERY PACK When the charging lamp is green, charging is completed. NOTE: The charging process takes approximately 7 hours to complete for rechargeable batteries. AC/DC converter's suitable power range: 50-60Hz; voltage 85V-265V. Purchase replacement NIMH battery pack from an authorized PLS dealer. Use PLS HVR 505 with caution in humid or wet weather conditions. Do not put the laser back into the case unless it is thoroughly dry. Condensation may corrode the battery connections and/or cause distortion of beams in lighthouse. 3

KEYPAD KEYPAD OPERATION - FUNCTIONS AND INDICATORS 4) MANUAL INDICATOR 7) MANUAL KEY 1) POWER SWITCH 2) POWER LIGHT 3) LOW POWER 12)AUTOMATIC (BLINK) DRIFT SYSTEM 1) Power switch: turn on or off unit. 2) Power light: red light, power on. 3) Low Battery lndicator: LED blinks, the battery should be charged or replaced. 4) Manual Indicator: green LED on in manual mode. 5) Accelerate key: variable speed, 0-60-120-600 r.p.m., press multiple times to adjust through a cycle. 6) Scanning key: variable angle, 0-10º-45º-90º-180º, press multiple times to adjust through a cycle. 7) Manual/automatic key: to change from automatic to manual leveling. 8) Counterclockwise rotation key: when rotation is stopped, press to start scanning of orientation. 9) Clockwise rotation key: when rotation is stopped, press to start scanning of orientation. 9) CLOCKWISE ROTATION 10) X AXIS CALIBRATION 5) ROTATIONAL SPEED ADJUSTMENT 10) Adjustment key in X slope direction: when the instrument is in the manual mode, press to adjust slope of X direction. 8) COUNTER CLOCKWISE ROTATION 11) Y AXIS CALIBRATION 6) DIRECTION SCANNING KEY 11) Adjustment key in Y slope direction: when the instrument is in the manual mode, press to adjust slope of Y direction. 12) Tilt or ADS (automatic drift system) blinks slowly when active, blinks quickly to warn user of a change in alignment from original set up. 4 5

FUNCTIONS APPLICATIONS Power switch Press 1 (See keypad chart) The unit is self-leveling and power light is lit. Press the key again and the unit will turn off. After laser has automatically leveled, the laser beam stops blinking. The laser will rotate up to 600 r.p.m. If the gradient exceeds ±5º, the manual indicator will blink. NOTE: If the unit does not level within 5 minutes, it will shut off. Rotation Mode The 5 key adjusts rotation speed. Adjust through a cycle. To stop rotation, press the 5 key. Rotation will be counter clockwise. When the 9 clockwise. Scanning Mode key is pressed, rotation will be Adjust rotation speed until the laser stops rotating. Press the 6 mode. Press the 6 scanning angle. key and the unit starts scanning key again to adjust Press 8 counter clockwise or 9 clockwise; key will move scanning laser line. Setting Slope The PLS HVR 505 can set slope on dual axes. Press the 7. The manual indicator is on. Setting slope of X direction: Aim X1 of the instrument in the direction necessary to set slope. Press 10. The laser beam moves upwards or downwards. Setting slope of Y direction. Aim Y1 of the instrument in the direction necessary to set slope. Press 11. The laser beam moves upwards or downwards. Automatic Drift System Press 12. Press the TILT key, the power indicator blinks slowly. After the instrument has leveled automatically for about 3 seconds, the ADS function is activated.the power indicator will blink quickley, and automatic leveling function shuts off when the instrument is disturbed by external circumstances. At the same time, the laser module will stop scanning and start blinking. 6 Y2 X2 Y1 X1 Height Transfer (Leveling) Turn the instrument on. The leveling LED is flashing and the instrument is self leveling. If the LED lights continuously the rotary head starts and the laser beam will be turned on. Attach the PLS HVD 505 Detector at this reference point on a rod and move this height to zero. Now the respective difference in levels to the reference height can be measured on the ground. It is useful to use a flexible rod to measure positive and negative values simply. Laying out Slope Using the PLS HVR 505 Fasten the PLS HVR 505 to a tripod and plumb up over the benchmark or hub. Make certain that the PLS HVR 505 is positioned on the tripod so that the X axis points toward where you need slope. Auto-level the PLS HVR 505 by depressing the top green button. Once the laser is level and rotating at 600 rpm, attach the detector to the grade rod. Take the grade rod with the detector attached to the end of the needed distance (end of pipe, footing or form board). Find level on the detector by a solid tone or by the solid line on the LCD. Next, depress the top center button on the remote (RC 505) to engage the manual mode on the PLS HVR 505. Then lower the detector by the correct distance based on the needed slope. Some examples are listed below. Depressing the right red button lowers the laser towards the detector. Hold down the right-pointing arrow key until the detector beeps that you are within range. Now fine-tune the laser adjustment by going up using the left-arrow key or down using the right-arrow key until the laser is locked on with a solid tone or by the solid line on the LCD. Examples -1% Slope @100' on the grade rod 12" from level -3% Slope @100' on the grade rod 36" from level -1% Slope @50' on the grade rod 6" from level... -3% Slope @50' on the grade rod 18" from level -1% Slope @25' on the grade rod 3" from level -3% Slope @25' on the grade rod 9" from level...... For a positive slope layout, reverse the above examples. 7

APPLICATIONS CHECKING CALIBRATION Caution! The automatic leveling is switched off in manual mode. If the instrument gets moved it will not turn off. In the semi-manual mode the tilt control is active only in X direction. We recommend using a second detector to control the sloped plane. Vertical Use REMOTE CONTROL... The PLS HVR 505 has third leveling axis (z-axis). Place the instrument as shown. The plumb beam will be leveled automatically. The turning rotor head projects an upright plane to the plumb beam at an angle of 90. To adjust the alignment line use the arrow keys to move the laser beam right and left. Right angles can then be measured simply and quickly. The PLS HVR 505 may be used with the PLS RC 505 infrared remote control. Point the remote in the direction of the PLS HVR 505 for remote operation. Remote distance is 70 feet indoors and 40 feet outdoors. There are 9 keys on the panel of the remote unit. The remote panel matches the keypad of the PLS HVR 505. Pressing any key will make the indicator lamp blink once indicating remote signal is being sent. CHECKING CALIBRATION The PLS HVR 505 should be checked, like all measuring instruments, before use. Set the PLS HVR 505 on a stable surface - Method A. Turn the laser on and let it level. Mount the PLS HVD 505 Detector at a fixed distance, e.g. at 90 feet, and move it onto the laser plane. Now turn the instrument around to each 90 point and let the instrument level. In each case, measure the difference to the first height. If the deviation is smaller than 1/8 inch, the instrument is within the specification. In the case of larger deviations the instrument has to be calibrated. A. Instrument Checking - Method B (1) Place the instrument at the point of 90 feet in front of wall (or set a scaleplate at the point of 90 feet away from the instrument), and then adjust the level of the base approximately to aim the X1 to the wall (or scaleplate) as depicted at right. (2) After switching on the power, use the detector measuring the h1 of X1- beam on the wall or scaleplate. (3) Loosen the screw of the tripod and then turn the instrument 180 O to measure the h2 of X2-beam on the wall or scaleplate. D-value between h1 and h2 ought to be less than 1/8 inch. (4) Check the Y-beam in the same way. B. Level Adjusting If the D-value between h1 and h2 is more than 1/8 inch, adjust the instruments according to the following steps: 1. Y-axis adjustment. (1) Press the Key ON/OFF when power indicator lights & automatic leveling of the instrument starts up. (2) Press the key and simultaneously for 3 seconds;when mode indicator blinks, the instrument enters mode of adjusting. (3) Press the key or of Y-axis repeatedly and check the position of laser beam when mode indicator is blinking until the D-value between h1 and h2 is less than 1/8 inch. (4) Press the Key and simultaneously to hold the adjustment until mode indicator goes out. If the instrument is set horizontally, Y-axis adjustment stands for Z-axis adjustment. C. X-axis Adjustment (1) Press the Key ON/OFF when power indicator lights & automatic leveling of instrument starts up. (2) Press the Key and simultaneously for 3 seconds. When undervoltage indicator blinks, the instrument enters mode of adjusting. (3) Press the Key or of X-axis repeatedly and check the position of laser beam while undervoltage indicator is blinking till D-value between h1 and h2 is less than 1/8 inch. (4) Press the Key and simultaneously to hold the adjustment until undervoltage indicator goes out. If canceling the adjustment, please shut off the instrument and then turn it on. If the adjusting range exceeds range permitted, the power indicator will flash. Notice: Once the D-value exceeds the error range that instrument permits, please contract the supplier to repair the instrument. D. Plumb Point Check (1) Place the instrument between two walls with distance of 90 feet. (2) Place the instrument on its side and then adjust. (3) Switch on the power, and then measure the middle point of the laser beam on the wall: ha, hb and ha, hb. (4) 1=hA-hA, 2=hB-hB. D-value between 1 and 2 ought to be less than 1/8 inch. E. Adjusting If-D value between 1 and 2 is more than 1/8 inch, adjust the instrument according to procedure described in B. 8 9

10 ROTARY SPECIFICATIONS PLS HVR 505: Accuracy: Down point accuracy: Up point accuracy: Leveling range: ± 5º Operation range: Rotation speed: Light source: Operating temperature: Storage temperature: Laser Class: Power supply: Operating time: Charging time: Protection grade: Size / Weight: PLS RC 505 Remote Control: Operating distance Charger LDG 2+2: Input: +/- 1/8 inch @100 feet 3m @ 30mm +/- 1/8 inch @10 feet 3mm @ 3mm +/- 1/8 inch @100 feet 3mm @ 30mm Radius 500 feet w/detector 150m 0-600 rpm laser diode, wavelength 635nm, <1mW (HVR 505 R) wavelength 532 nm, <5mW (HVR 505 G) 32º F (0ºC) to 104º F (40º C) -22º F(-30º C) to 140º F (60º C) II Caution (21CFR1040) (HVR505 R) III DANGER (HVR 505 G) 4 x C Size NIMH Batteries approximately 20 hours maximum 7 hours (NiMH ONLY) IP64 (Water- resistant), not submersable 7.5 inch x 8 inch x 6 inch 190.5 mm x 200 mm x 152 mm 4.9 lbs (unit only) 2.22 kg 70 feet Output: 12V / 1.25A 100-240V AC / 47-63Hz Use the charger indoors only! Do not attempt to charge Alkaline Batteries. Design and specifications are subject to change without prior notice. WARRANTY In the event of a claim please contact your PLS dealer or PLS. Attempts at repair or detectable improper treatment will void any warranty claim. Please use the original transport case for shipment. This product is warranted by PLS Pacific Laser Systems to the original purchaser to be free from defects in material and workmanship under normal use for a period of three years from the date of purchase. During the warranty period and upon proof of purchase, the product will be repaired or replaced (with the same or similar model at our option) without charge for either parts or labor through PLS. The purchaser shall bear all shipping, packing and insurance costs. Upon completion of the repair or replacement, the unit will be returned to the customer, freight prepaid. The warranty will not apply to this product if it has been abused or altered. Without limiting the foregoing, battery leakage, dents or gouges to the plastic housing, broken optic windows, damage to the switch/led membrane are presumed to result from misuse or abuse. Tampering with or removal of the caution or certifications labels voids this warranty. Neither this warranty nor any other warranty, express or implied, including implied warranties of merchantability, shall extend beyond the warranty period. No responsibility is assumed for any incidental or consequential damages. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. 11

PLS HVD 505 DETECTOR OPERATING MANUAL 1. SPECIFICATIONS Available Distance: From rotary PLS HVR 505 (2.0 in) Accuracy: Precise detecting: +_ 1mm ( +_ 0.04in) Rough detecting: +_ 2mm ( +_ 0.08in) Detecting Indication: Bi-surface LCD, buzzer Power: DC9V alkaline battery Automatic Power-off Time: Approx. 20 minutes Working Temperature: -20 C o to +50C o (-4 o F to +122 o F) Dimensions: 135 (L) X 65 (W) X 24.5 (H)mm 5-3/4" x 2-3/4" x 1" Weight: 0.15kg (0.44lbs) (with battery) 2. LCD Precise Detecting Reference Position Display: Higher than reference (high frequency beep) Rough Detecting Reference Position Display: 3. PANEL LCD (Both on Front Shell & Back Shell) Buzzer ON/OFF Once power on, default of buzzer is on) 36mm 5/12 Inches Mark Laser Receptor In reference line (long beep) Detecting Mode Lower than reference (high frequency beep) Poor Power: 12 Buzzer On: Buzzer Off: Buzzer Power Switch CAUTION: The HVD 505 R + G detectors are dedicated and unique to each HVR 505 R + G rotary laser and may not be used with other laser tools. 13

PACIFIC LASER SYSTEM S The Professional Standard PACIFIC LASER SYSTEMS 2550 KERNER BLVD. SAN RAFAEL, CA 94901 WWW.PLSLASER.COM 1 800 601 4500