MODEL 8630-CRC-S, 8630-CRC-P PRESSURA CLEAN ROOM PRESSURE CONTROLLER

Similar documents
MODEL 8631-CRM/8631-CRC PRESSURA CLEAN ROOM PRESSURE MONITOR/CONTROLLER

MODEL 8631-HM(-BAC)/8631-HC(-BAC) PRESSURA ROOM PRESSURE MONITOR/CONTROLLER

MODEL 8636 / 8636-LN / 8636-BAC SUREFLOW ROOM PRESSURE CONTROLLER

MODEL 8630 PRESSURA ROOM PRESSURE MONITOR

MODEL 8635 SUREFLOW ROOM PRESSURE MONITOR

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER

MODEL RPM10/RPM20 (-LON)/RPM20-CC PRESSURA ROOM PRESSURE MONITOR

Model FHS5 Slimline Display Interface for FHC50/FHM10 P/N Installation Instructions

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

RPM1600 Series Room Pressure Monitors

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Laboratory Exhaust Air Terminal

MODEL ELC-12/40-CVM-D BATTERY CHARGER

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

WINDSHIELD WIPER SERVICE KIT

Blow Off Valve Retrofit Kit

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

TMS Series MP46x Flex Probes* Installation Instructions

Prodigy HDLV Manual System Installation Instructions

ATLAS TRANSFER CASES CABLE SHIFTER units built before 4/30/12

STANDARD TRAVERSE SYSTEMS FOR LDV, PDPA AND PIV

Installation and Start-Up Instructions

Volatile Organic Compounds Probe Maintenance Application Note TSI-149

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

ATP-2040 Electric Damper Actuator/Transmitter

Installation, Operation and Maintenance Manual

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Integra Pneumatically Operated Diaphragm Valves with Position Indication Option

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

TKS-5001, TKS , TKS-6001, TKS-7001

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

Item. Table 1. Circuit Breaker Replacement Kit 1. Item Part No. Description QTY. Remarks No. Includes. Items Items EE55781 WORK SAFELY!

ADVANCE ADAPTERS INC. P/N: JEEP TJ & (XJ 84-01) ATLAS 4 SPEED CABLE SHIFTER units built after 5/1/12

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

MA-5200 Series MA-5300 Series

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

LGT-311L Bumper LED Light Kit EZ-Go RXV Installation Instructions

Rosemount 485 Annubar Threaded Flo-Tap Assembly

MODEL ELC-12/60-D BATTERY CHARGER

Rosemount 585 Annubar Flanged Flo-Tap Assembly

Pro-Swirl Manifold Air Heater

Installation and Start Up Instructions

Installation, Operation, and Maintenance Instructions

M Remote Mounting Kit

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

R-317 Air Flow Controller

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

RA-2000 Airflow Measuring System

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

INSTALLATION INSTRUCTION

Master/Slave Actuators Spring Return Rotary 24 Vac - Modulating Control

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

Integra Pneumatically Operated Diaphragm Valves with Position Indication Option

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

LS Series. Remix Shaft Installation Instructions REQUIRED TOOLS PARTS WORK SAFELY! PREPARATION/SAFETY PROCEDURES

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

SWM Series Wall Mount

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

Rosemount 285 Annubar Pak-Lok Assembly

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Remove the rubber cover in order to expose the two studs. >>>>>> >>>>>> Screw the vibra-mount to the side of the strut tower mount.

JUL 17 Rev M

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

Snow Switch Models HSC 4 (P/N 24220) & HSC 5 (P/N 24221)

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

PIL0478 ISSUE 01/ 07/16

AD592/592-10K Non-Room Units with a Junction Box, Weatherproof (WP) or Weather Tight (EU) Enclosure

Technical Service Bulletin

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

Rosemount 485 Annubar Flanged Assembly

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc.

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A

DRAWING NO WI APPROVAL ISSUER: ENGINEERING: PRODUCTION/MATERIAL: QA APPROVAL: REV 2 DATE BAS BAS WRC

E.S.P. Embedded Sensing Probes for Motor Brushes

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

Sivoia QED roller 20TM. Installation Instructions

Detroit Speed, Inc. Subframe Connectors Camaro/Firebird P/N:

Sivoia QEDTM Installation Instructions

Service Bulletin DIS185SSI4F Air Compressor Multiple Component Update

Standard Installation Fire/Smoke Damper Models: FR1, FR2 Smoke Damper Models: SR1, SR2

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator.

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Transcription:

MODEL 8630-CRC-S, 8630-CRC-P PRESSURA CLEAN ROOM PRESSURE CONTROLLER INSTALLATION INSTRUCTIONS WARNING: The Model 8630-CRC Clean Room Pressure Controller must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause serious damage to the unit and void the warranty. The pressure sensor must be mounted through the wall between the controlled space (clean room) and referenced space (airlock / hallway). These installation instructions guide the installer through the installation of the TSI Model 8630-CRC PresSura Clean Room Pressure Controller. Please read these instructions thoroughly before beginning installation. Component List Figure 1: Typical Installation Part Number Qty Description 801915 1 8630-CRC Clean Room Pressure Controller 800420 1 Transformer 800414 1 Transformer cable 800199 1 Controller Output Cable and either 800xxx 1 Pressure Transducer 801913 1 Sensor Port Assembly 800420 1 Transformer 800414 2 Transformer Cable or 801912 1 Pressure Sensor Assembly 800248 1 Pressure Sensor Cable TSI and TSI logo are registered trademarks of TSI Incorporated. PresSura is a trademark of TSI Incorporated.

Pressure Sensor Installation Figure 2: Pressure Sensor Orientation and Mounting Template WARNING: 801912 pressure sensor must be mounted through the wall between the controlled space (clean room) and referenced space (hallway), exactly as shown in Figure 3 and 4. 1. Determine pressure sensor location (Figures 1, 2, and 3). Pressure sensor typically mounts in the reference space, and the plate mounts in the clean room. NOTE: Pressure sensor is not symmetrical. If sensor is to be centered over hallway door, measure one inch to the left of center for 2 ¼ hole. 2. The pressure sensor must be orientated on the wall as shown in Figure 2. Looking at the mounted sensor, sensor hole is on the left (2¼ ) and wire hole is on the right. 3. Drill a 2¼-inch hole through each side of the wall to accept the sensor tube. 4. Drill a 7/8-inch hole on the side of the wall that the pressure sensor will be mounted. This hole is for the six-conductor sensor cable. Refer to Figure 2 for a hole mounting pattern. 5. Slide sensor cover to right and remove screw that holds the sensor base to the pressure sensor (Figure 2). Remove pressure sensor and store in a safe place. 6. From the side of the wall the sensor will be mounted, slide the sensor tube through the wall. Mark the tube where it is flush with wall. Remove sensor tube and cut tube 1/8 inch shorter than flush marking. NOTE: If 12 sensor tube is not long enough add a 1 to 2 adapter and extend with 2" OD tube. Do not extend sensor tube with 1 tubing. 7. From the side of the wall the sensor will be mounted, slide the sensor tube through the wall. Slide the dummy plate over the end of the tube. Screw the pressure sensor base and dummy plate to the wall (Figure 3). 8. Wire the pressure sensor per Figure 10. Run sensor cable to the Clean Room Pressure Controller 4 x 4 electrical rough-in box. 9. Insert fire protection sealant (provided) into 7/8 wire hole to seal. 10. Install and screw the pressure sensor onto the base. Slide cover to the left to hide the sensor. Finished installation should look as shown in Figure 4. WARNING: Do not touch the sensor element in the pressure sensor. Do not run wires through the air passage. Doing so will damage the sensing element.

Figure 3: Cutaway View of Mounted Pressure Sensor Figure 4: Pressure Sensor Mounting Figure 5: Pressure Transducer Mounting

Pressure Transducer Installation WARNING: 801913 pressure plates must be mounted in the wall between the controlled space (clean room) and referenced space (hallway), exactly as shown in Figure 6 and 7. 1. Install pressure transducer in desired location (typically above ceiling). The transducer must be mounted on a wall in the correct position per Figure 5 (screws not provided). Do not mount pressure transducer to duct or other vibrating surface. 2. Wire the pressure transducer per Figure 11. Run sensor cable to the Clean Room Pressure Controller 4 x 4 electrical rough-in box. 3. Determine pressure sensor location (Figures 1, 6 and 7). Pressure sensor typically mounts in the reference space, and the plate mounts in the clean room. 4. Drill a 2¼-inch hole through each side of the wall to accept the sensor tube. 5. Run pneumatic tubing from transducer to sensor locations. For a positively pressurized space, the high port should be connected to the controlled space and the low port to the reference space. Similarly, for a negatively pressurized space, the low port should be connected to the controlled space and the high to the reference space. 6. Connect the pneumatic tubing to the nipple on the back side of the pressure plate. 7. Insert the pressure plate into the hole in the wall. Screw the pressure plate to the wall. The finished assembly should look like Figure 6. Figure 6: Cutaway View of Mounted Pressure Transducer Assembly Figure 7: Pressure Transducer Mounting

Transformer Installation WARNING Make sure no power is applied until all wiring is complete. Follow all applicable electrical codes, and have qualified personnel install the transformer. Figure 8: Transformer Installation Note: Each system must be installed with supplied transformer. If TSI transformer is discarded and a central transformer is installed, a separate clean transformer must be installed in line between the TSI system and central transformer. 1. Mount a standard 4 4 1½ electrical box at a convenient location within 20 feet of pressure Controller. 2. Run 115 Volt, single phase, 60-Hertz line voltage (115 VAC) to electrical box. Follow all applicable electrical codes. 3. Connect 115 VAC line voltage HOT wire to BLACK wire on transformer and NEUTRAL wire to WHITE wire on transformer (Figure 8). 4. Connect the RED wire on 800414 transformer cable to either YELLOW wire on the transformer and the BLACK wire to the remaining YELLOW wire. 5. Screw the transformer to the electrical box. 6. Run transformer cable from the transformer electrical box to the pressure Controller. Have at least 8 inches of cable coming out of the pressure Controller rough in electrical box before trimming cable to length. Pressure Controller Installation Pressure Controller Rough-in 1. Select the mounting location of the pressure Controller. The construction plans normally show the mounting location. If no location is specified, then the unit is typically installed as shown in Figure 1. 2. Install a standard double gang electrical box (4 4 ). 3. Slide the pressure Controller cover to the right and remove three screws holding the electronics to the base (Figure 9). Remove base. 4. Install the base to the 4 4 electrical box. The base s THIS SIDE UP arrow must be pointing towards the ceiling.

Note Two screws are hidden behind the cover when fully open. The cover will slide to the right approximately 2 inches until a stop is hit. Pull cover to completely remove from electronics and expose the screws. Figure 9: Pressure Controller Mounting Pressure Controller Wiring WARNING: Do not connect more than 24 VAC to any terminal. Do not apply voltage to the RS-485 output or analog output. Severe damage may occur to the unit if voltage is applied. 1. Remove the connectors from the back of the Pressure Controller. 2. Refer to the wiring diagram (Figure 10 or 11) for proper wiring installation. 3. If additional options need to be wired, refer to building prints for proper wiring diagram. 4. Plug the connectors back into the Pressure Controller. 5. Carefully push the wires into the electrical box and mount the Pressure Controller. Install three screws to hold Pressure Controller firmly to base. Install cover and slide left to hide display.

WARNING: Controller must be wired exactly as diagram shows. Making modifications to the wiring may severely damage the unit. Figure 10: Wiring Diagram with Electric Actuators and Pressure Transducer

WARNING: Controller must be wired exactly as diagram shows. Making modifications to the wiring may severely damage the unit. Figure 11: Wiring Diagram with Electric Actuators and Through-The-Wall Sensor

TSI Actuator/Damper Installation WARNING: Building prints normally determine damper location and mounting configuration. They supersede the guidelines below. 1. The actuators are shipped mounted to the damper. No adjustments are needed prior to mounting the assembly. 2. The damper must be installed with the damper shaft parallel to the ground (Figure 12). 3. Slip-fit dampers mount INSIDE the duct work. Flanged dampers bolt to the duct work. No ductwork can be inside of dampers, or interfere with damper rotation. 4. Screw slip-fit damper to duct work using 1-inch or shorter screws. Make sure screws do not interfere with damper blade rotation. Bolt flanged dampers securely to ductwork, but do not force damper to fit (deforms damper). Figure 12: Proper Damper Mounting If you need assistance installing the system, call TSI Customer Service at 651-490-2811 or 800-874-2811. TSI Incorporated Visit our website www.tsi.com for more information. USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 491 11 87 64 Germany Tel: +49 241 523030 India Tel: +91 80 67877200 China Tel: +86 10 8251 6588 Singapore Tel: +65 6595 6388 P/N 1980420 Rev F 2013 TSI Incorporated Printed in U.S.A.