STAPS Wireless Steam Trap Monitoring System

Similar documents
IBV Series C-LF2 Carbon Steel Inverted Bucket Vertical Steam Trap

ABV21i and ABV40i Air Actuated Boiler Blowdown Valves

MSC Manifolds - DIN for Steam Distribution and Condensate Collection Installation and Maintenance Instructions

VAD Variable Area Desuperheaters

Fig B34 Carbon Steel 'T' Type or Basket Type Strainers

BCV Blowdown Control Valves DN15 to DN50 (½" to 2")

FT47 SG Iron Ball Float Steam Traps (DN15 to DN50)

MSC-125 and MSC-160 Manifolds for Steam Distribution and Condensate Collection.

Spiratec ST14, ST16 and ST17 Sensor Chambers and Sensors

m-csg Ultra-compact Clean Steam Generation System

AEL6 Series Smart Electric Actuators for ½" to 4" Control Valves

AEL5 Series Electric Linear Actuators for DN15 to DN100 Control Valves

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

Ti200, Ti300, Ti400, Ti450, Ti480 Thermal Imagers

AEL6 Series Smart Electric Actuators for DN15 to DN100 Control Valves

Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO Thermal Imagers

DCV1, DCV2 and DCV3 Disc Check Valves Installation and Maintenance Instructions

PV4 and PV6 Piston Valves

2-Year Limited Warranty. See the Users Manual for the full warranty.

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

M Series Condensate Recovery Unit

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

Energy Storage System for Home

APT10-2 Automatic Pump Trap

S and SF Series Cast Iron Inverted Bucket Steam Traps

Energy Storage System for Home. High Efficiency - Peak efficiency 97.3% Bi-directional DC-DC converter

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

M21Fi ISO Reduced Bore Firesafe API607 Ball Valve DN15 to DN150 Flanged PN40

BBV Automatic or Manually Actuated Boiler Blowdown Valves DN15 to DN65

3-Year Limited Warranty. See the Users Manual for the full warranty.

DP163, DP163G and DP163Y Pilot Operated Pressure Reducing Valves with Stainless Steel Bodies

M21Fi ISO Ball Valve DN15 to DN150

M21Ti ISO Reduced Bore Ball Valve for the Tobacco Industry DN15 to DN150 Flanged PN40

½" to 4" (DN15 to DN100) LEA31 and LEA33 ANSI Control Valves Installation and Maintenance Instructions

Pilot Operated Pressure Reducing Valves with Stainless Steel Bodies

M21Hi ISO Reduced Bore Ball Valve DN15 to DN150 Flanged PN40

Remote Condition Monitoring

M10Si ISO Ball Valve DN¼" to DN2½"

Pilot Operated Pressure Surplussing Valve with Cast Steel Body

TFA Flowmeter for Saturated Steam Service Installation and Maintenance Instructions

ABB central inverters PVS to 2091 kva

Versatile and Rugged Industrial LIthium/LiPO Charger Series

3. Operating instructions: Minor 200

PF6 Stainless Steel Piston Actuated On/Off Valves

MFP14, MFP14S and MFP14SS Automatic Pumps

outdoor access point Multi Point Station Series

M10F Ball Valve DN¼" to DN2½"

Multi Point Station Series

The AEL6 series smart electric actuator

DP143, DP143G and DP143H. Pilot Operated Pressure Reducing Valves with Cast Steel Bodies

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment

SDP143 Pilot Operated Pressure Surplussing Valve with Cast Steel Body

T2111EN Technical Data Sheet Rev 04 Air Cooled Rectifier Bridge MVR : 690V, 1600Adc

ILED Aquarius Illuminated Windsock. User Manual

ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

LCU DX Efficient cooling with no loss of space

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

Pressure transmitter for industrial applications Type MBS 4510

SVL488 Stainless Steel Safety Valve for Clean Service Applications

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

MGE TM Galaxy TM 7000

PF6 Stainless Steel Piston Actuated On/ Off Valves

i RANGE HYDROPATH Technology The home of

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

Compact Scales. Software Revision V1.25 & above

596 Rectifier Retrofit

Direct Contact Desuperheaters

Power Conversion. Battery Chargers. Model

DP143, DP143G and DP143H. Pilot Operated Pressure Reducing Valves with Cast Steel Bodies

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

High Power Directional Coupler

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Pressure transmitter for industrial applications Type MBS 4500

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

Technical Information Liquiline System CAT810

PERISTALTIC DOSING PUMP OPERATING MANUAL. MODEL: FS SERIES Fixed Speed Peristaltic Pump

Express 100 DC Commercial Charging Stations

Function ECU, Wireless

PRELIMINARY COMPEX SYSTEMS

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

MGE TM Galaxy TM 7000 GFC

KSK Outdoor Parking Guidance System

QLM and QLD Series DN125 to DN200 Three Port Control Valves

Model Number Structure

Date received into service; / /.

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

SCA Series Steel Inverted Bucket Steam Traps

INSTALLATION AND USER INSTRUCTIONS

INFRESCO 2KW VARIABLE CONTROLLER Issue 3

Level Measurement Point level measurement - RF Capacitance switches

PowerFlex 6000 Medium Voltage AC Drives

Function ECU, Wireless

SonoSelect and SonoSafe energy meters

Transcription:

Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without notice. Copyright 2017 TI-P014-02 EMM Issue 4 STAPS Wireless Steam Trap Monitoring System Description The STAPS wireless steam trap monitoring system has been designed to efficiently monitor and evaluate steam trap operation. It surveys the operation of the steam trap at regular intervals and identifies poor performance that can cause reduced plant efficiency and increased energy consumption. It can diagnose both failed-open steam traps that leak live steam and those that have failed-closed or are blocked that result in waterlogging leading to plant damage, product spoilage and health and safety concerns. Using non-intrusive installation technology combined with a 2.4 GHz wireless network, it is an ideal solution for steam trap monitoring. It is suitable for use with all types of steam trap and can be connected to pipework up to 100 mm (4"), via an adjustable clamp. Benefits include: - Continuously monitoring of all steam traps. - Reduces energy and emissions loss significantly. - Immediate identification of failure location for quick response / action. - Ability to validate losses via integrated software. - Non-intrusive no need to break into the steam pipeline to install. - A range of clamps to suit pipework ranging up to 100 mm (4"). - No need for height access equipment to check trap operation. - Typically 3 years battery life. Certification and Approvals EMC Emissions and immunity:emissions class B and Industrial immunity. Complies with FCC - EN 61326-2-1: 2006 rules CFR 47 (1st October 2011). Safety to IEC / EN 61010-1 2001 - EN 61326-2-3: 2006 (second edition). CSA 22.2 Associated equipment: - Repeater. - Laptop / software. -. - Access to the company's LAN network is preferred, giving improved network coverage. - For stand alone systems, it is recommended that a network switch device is used between the and receiver. application: - Allows quick and easy viewing of whole steam trap population. - Alerts the user to any issues with traps. - Historical view of data and maintenance on each trap. Sizes and pipe connections The STAPS wireless monitoring system is suitable for connecting to pipework up to 100 mm (4"), via an adjustable clamp. The head can be directly mounted to the sensor or fitted remotely. Wireless steam trap monitoring system + wing nut clamp that is used on pipelines up to 32 mm. Wireless steam trap monitoring system + 'U' bolt and wing nuts for use on STS17 or STS17.2 compact pipeline steam trapping stations. Wireless steam trap monitoring system + jubilee clamp that is used on pipelines from 40 mm to 100 mm. Page 1 of 5

Materials Head casing PA12 glass filled Sensor housing Stainless steel 316 / 304 Sensor PZT Clamp Stainless steel 430 / 304 Winged nut Stainless steel 316 LED enclosure PA12 Sensor cable Probe FEP / PTFE insulation Stainless steel Mounting Bracket Stainless steel 430 Sensor guide Stainless steel 304 / Repeater Casing ABS Technical information Integral battery Maximum altitude Lithium Thionyl Chloride 3 000 m (0.7 bar atmospheric) Ambient temperature range -29 to +70 C Maximum pipe temperature 425 C Maximum relative humidity 95% : Available with post or tethered head mountings. Enclosure rating Output Display Operating modes IP65 Wireless 2.4 GHz (frequency range 2.405 GHz to 2.480 GHz) LED Trap monitoring unit - end device or repeater / end device Maximum output transmitting power Modulation type Channel space Antenna gain 6.3 mw QPSK 5 MHz 0 dbi System requirements Windows XP.NET 3.5 Windows 7.NET 4.5 Network switch or access to company LAN network / Repeater Power Current Connector Maximum altitude Mains powered 100 250 Vac, 50 60 Hz ac 0.5 A 100 Vac dc 1.5 A 12 V ac 2 pin IEC 320-C8 3 pin UK, US and European mains plug dc 2 pin IP65 connector 3 000 m (0.7 bar atmospheric) Ambient temperature range -29 to +70 C Maximum relative humidity 95% Enclosure rating Display Output Operating modes IP65 (Excluding external power supply) LED Wireless 2.4 GHz (frequency range 2.405 to 2.480 GHz), Ethernet. or repeater Page 2 of 5

How does it work? A head unit assembly mounted on the pipe upstream of the trap to be monitored 'listens' to the sound signature of the trap in operation. This sound signature is categorised and transmitted via 2.4 GHz wireless network to a central. The determines the trap condition and calculates any steam loss. Each STAPS head unit assembly is powered by a long life Lithium battery (typical battery life of over 3 years). It can communicate directly to a receiver that is connected to the software via a LAN connection or via another intelligent head or repeater. The software can be installed onto a on the sites internal network, or onto a standalone local. The STAPS head, repeater and receiver create a network and can communicate with each other, passing on the steam trap data to the supervisory. The illustration below illustrates a typical network. Building 2 Building 1 Intelligent head unit Steam trap Repeater Control room LAN Building 2 Building 1 Intelligent head unit Building 3 Steam trap Router / Repeater Control room Network switch Page 3 of 5

Dimensions / weights (approximate) in mm and kg Wireless steam trap monitoring system + wing-nut clamp B C 47 A E 90 97 D F G 125 145 Size A B C D E F G Weight DN15 - ½" 234 117 126 44-69 36 55 50 1 kg DN20 - ¾" 234 117 126 44-69 36 55 50 1 kg DN25-1" 234 117 126 44-69 36 55 50 1 kg DN32-1¼" 234 117 126 44-69 36 55 50 1 kg DN40-1½" 234 117 126 44-69 36 55 50 1 kg DN50-2" 234 117 126 50 30 1 kg DN65-2½" 234 117 126 50 30 1 kg DN80-3" 234 117 126 50 30 1 kg DN100-4" 234 117 126 50 30 1 kg Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions supplied with the product. Disposal: - The Lithium Thionyl Chloride battery must be disposed of in line with local legislation. It must be remembered that battery hazards remain even when the cells are discharged. - The Piezo sensor should be disposed of in line with local lead disposal guidelines. No other ecological hazard is anticipated with the disposal of this product. It should be disposed of within the local recycling procedures. How to order Please contact your local Spirax Sarco representative to arrange a site survey and installations. A preliminary site survey of the plant must be conducted by trained personnel, the survey will identify the optimum number of s and Repeaters together with their most effective location, to give the most robust wireless network. It will also establish the requirements for the IT network. Page 4 of 5

Spare parts Only the parts listed below are available for the STAPS system. No other parts are supplied as spares. Available spares Battery (SAFT LS 33600 3.6 V battery) 1 3 1 'O' ring spares kit 2 Head mounting bracket, 'U' bolt and wing nuts 8, 9, 10 and 19 10 Ethernet cable spares kit 15 Clamp 'T' bolt and wing nut 'U' bolt and wing nuts for STS17 or STS17.2 5, 6 and 7 20, 21 and 22 9 8 19 Power supply (UK) spares kit 11 and 14 (US) spares kit 12 and 14 (EU) spares kit 13 and 14 4 17 16 18 2 Front cover spares kit 3 and 4 Spare receiver mounting kit 6, 17 and 18 How to order spares Always order spare parts by using the description given in the column headed 'Available spares' and state the size and unit nomenclature that they are intended for. 5 6 Example: 1 off Battery spares kit (SAFT LS 33600 3.6 V battery) and 22 1 off Wall mounting spares kit or 21 1 off Clamp for use with an STS17.2 pipeline trapping station. These spares are for STAPS up to DN32 pipe size wireless steam trap monitoring system. 14 15 20 UK US 11 12 EU 13 Page 5 of 5