Safety Guard Switching Unit G9SX-GS

Similar documents
A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions. Ordering Information

A4EG CSM_A4EG_DS_E_6_1

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Clicks for Three Easily Discernable Positions

2NC (slow-action) Direct. Model. opening

D4BS CSM_D4BS_DS_E_8_4

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

D4GS-N CSM_D4GS-N_DS_E_7_2

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

Multiple Limit Switch

A165E CSM_A165E_DS_E_11_2

A22LK CSM_A22LK_DS_E_6_2

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

2NC (slow-action) Direct. Model. opening

Safety Switches & Operator Controls

Safety Limit Switch

D4NH CSM_D4NH_DS_E_7_1

Safety Interlock Switches

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

D4BL. Guard Lock Safety-door Switch

Digital display Pressure range ON/OFF output Linear output Model

D4BL. Guard Lock Safety-door Switch

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

CSM_D4N-_R_DS_E_6_1

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

G3PE-Single-phase. Solid State Relays for Heaters

D4NS/D4NS-SK. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Nextgeneration. Model Number Structure. Model Number Legend

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

A22TK Key-type Selector Switch with Direct Opening Mechanism

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

D4NL. Guard Lock Safety-door Switch. Best-selling Guard Lock Safety-door Switch Available in Several Compact, Multi-contact Models

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Safety Limit Switch

A22E. Emergency Stop Switch (22-dia./25-dia.) Install in 22-dia. or 25-dia. Panel Cutout. Model Number Structure L M 24A 01

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

Model Number Structure

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

D4JL. Guard Lock Safety-door Switch. World's Top * Holding Force of 3,000 N. Features

A22TK Key-type Selector Switch with Direct Opening Mechanism

DIN Track Terminal Blocks with Screw Terminals XW5T

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

Better Productivity by Standstill and Low-speed Monitoring

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

EStrong-series Emergency Stop

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

D4GL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key

D4NL CSM_D4NL_DS_E_9_2

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Smile 11 RA/-B Smile 12 RF/-G Reset button

S8JX-N/S8JX-G Series Replacement Brackets

DIN Track Terminal Blocks with Screw Terminals XW5T

Safety-door Switch. Ordering Information

Sense7-series Non-contact coded safety switch

DIN Track Terminal Blocks with Screw Terminals

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

Smile 41 Push-button box with/without emergency stop

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

Manual Reset Limit Switch

Hinged Safety Door Switch

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

Tina 11A Connection block

D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Small Limit Switch D4V

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Tina 4A Connection block

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22E/A22NE-P

Dimension A. Dimension B

Tina 10A/B/C Adaptor unit

D4DL. Guard Lock Safety-door Switch. Model Number Structure

A22NK. Key-type Selector Switches

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

D4NS. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Safety-door Switch. Model Number Structure

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

F3S-TGR-KM15/-KM16/-KH16

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

FMC-1/2 Tina Muting unit

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

MKey9-series Safety Interlock Switch with Guard Locking

D4DL. Locking Safety-Door Switch. Compact, Locking Safety Door Switch with Dual Key Entry. H Two types in the series: Mechanical-lock

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Transcription:

Enabling Grip Switch CSM DS_E_5_1 Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions The difficult task of configuring safety circuits is now easily achieved by combining the with the G9SX-GS. In addition to the standard models, the lineup also includes models with an emergency stop switch and models with a momentary operation switch. An optional Holding Key (sold separately) provides a versatile method for selecting modes. Equipped with conduit connector. Be sure to read the Safety Precautions on page 11. Features Positive Operating Feel Original Double Snap Action switch mechanism lets the operator precisely confirm the enable position. Safety Circuits Are Easy to Configure Safety circuits can be easily configured by combining the with the G9SX-GS Safety Guard Switching Unit. Click! Click! Press the top part... Press the bottom part... Safety Door Switch D4NS or others Enable Grip Switch Knob-type Selector Switch A22K Single-press design ensures a positive click feel when only one part of the switch is pressed, to enable positive confirmation. Selection Based on Application In addition to the standard models, the lineup also includes models with an emergency stop switch and models with a momentary operation switch. Safety Guard Switching Unit G9SX-GS The Selector Switch can be used to switch between normal operating mode (using the Door Switch) and maintenance mode (using the Enabling Grip Switch). Note: Refer to page 8 for information on connecting to the G9SX-GS. A holding key can be used to change modes rather than a key-type selector switch. -C000041 -BM2B041 Equipped with a Momentary Operation Switch Wall-mounted with Bracket -BE2R041 Equipped with an Emergency Stop Switch Safety Door Switch D4NS Normal operating mode Maintenance mode 1

Ordering Information Enabling Grip Switches Appearance Contact form Monitor switch switch Model Two contacts 1NC (grip output) None -C000041 Two contacts None Emergency stop switch (2NC) -BE2R041 Two contacts None Momentary operation switch (2NO) -BM2B041 Accessories (Order Separately) Appearance Item Model Rubber Cover (replacement part) -OP1 Mounting Bracket (for securing the ) -OP2 Holding Key -OP3 2

Specifications Standards and EC Directives Compliance with EC Directives and International Standards Low Voltage Directive GS-ET-22 Certified Standards Certifying body Standard File No. TÜV SÜD * Certification for CSA C22.2 No. 14 by UL is indicated by the. Certified Standard Ratings (Enabling Switch Section) TÜV (EN 60947-5-1) Note: Use a 10-A fuse type gi or gg that conforms to IEC 60269 as the short-circuit protection device. The fuse is not built into the Switch. UL/CSA (UL 508, CSA C22.2 No.14), CCC (GB 140.5) 24 VDC, 0.3 A (inductive load) 125 VAC, 1 A (resistive load) Ratings EN 60947-5-1 (certified direct opening) Ask your OMRON representative. UL * UL 508, CSA C22.2 No.14 E76675 CQC (CCC) GB 140.5 2008010305297698 KOSHA EN60947-5-1 2008-115 Item Utilization category AC-15 DC-13 Rated operating current (Ie) 0.75 A 0.55 A Rated operating voltage (Ue) 240 V 125 V Section Emergency stop switch Item (-BE2R041 only) (-BM2B041 only) Rated insulation voltage 250 V --- Rated ON current 2.5 A 5 A 0.1 A Rated load 24 VDC, 0.3 A (inductive load) 125 VAC, 1 A (resistive load) EN certification rating: AC-15 0.75 A/240 V DC-13 0.55 A/125 V General rating: 125 VAC, 5 A (resistive load) 250 VAC, 3 A (resistive load) 30 VDC, 3 A (resistive load) UL and cul rating: 125 VAC, 5A (inductive load, power factor: 0.75 to 0.8) 250 VAC, 3 A (inductive load, power factor: 0.75 to 0.8) 30 VDC, 3 A (resistive load) EN certification rating: AC-12 3 A/250 V DC-12 3 A/30 V General rating: 125 VAC, 0.1 A (resistive load) 8 VDC, 0.1 A (resistive load) 14 VDC, 0.1 A (resistive load) 30 VDC, 0.1 A (resistive load) UL and cul rating: 125 VAC, 0.1 A (resistive load) 30 VDC, 0.1 A (resistive load) EN certification rating: AC-12 0.1 A/125 V DC-12 0.1 A/30 V Minimum applicable load 24 VDC, 4 ma 5 VDC, 1 ma 3

Characteristics Item Degree of protection Section Operating section strength Cable pull strength Allowable operating frequency Electrical Mechanical Electrical durability Mechanical durability Dielectric strength Between terminals of the same polarity Between terminals of the different polarity Between each terminal and non-current carrying metallic parts Emergency stop switch (-BE2R041 only) IP66 (-C000041), IP65 (-BE2R041, -BM2B041) Operating direction: 200 N, 1 min 30 N, 1 min 20 operations/minute max. 20 operations/minute max. 100,000 operations min. (rated load) OFF-ON-OFF (direct opening): 100,000 operations min. OFF-ON: 1,000,000 operations min. 2,500 VAC, 50/60 Hz, 1 minute (impulse voltage) 2,500 VAC, 50/60 Hz, 1 minute (impulse voltage) 2,500 VAC, 50/60 Hz, 1 minute (impulse voltage) Insulation resistance 100 MΩ min. (at 500 VDC) Vibration resistance Malfunction 1.5 mm double amplitude, 10 to 55 Hz Shock resistance Malfunction 150 m/s2 max. Ambient operating temperature 10 to 55 C (with no icing or condensation) Ambient operating humidity 35% to 85% Ambient storage temperature 25 to 65 C (with no icing or condensation) Protection against electric shock Class II (double insulation) Pollution degree (operating environment) 3 (EN 60947-5-1) Conditional short-circuit current 100 A (EN 60947-5-1) Operating direction: 367 N, 1 min Rotating direction: 0.49 N m, 1 min 10 operations/minute max. (set/reset for one operation) 10 operations/minute max. (set/reset for one operation) 100,000 operations min. (set/reset for one operation) (rated load) 100,000 operations min. (set/reset for one operation) Note: The timing of contact outputs for two or more circuits is not synchronized. Confirm performance before application. (-BM2B041 only) Operating direction: 50 N, 1 min 60 operations/minute max. 120 operations/minute max. 100,000 operations min. (rated load) 2,000,000 operations min. 1,000 VAC, 50/60 Hz, 1 minute 1,000 VAC, 50/60 Hz, 1 minute 2,000 VAC, 50/60 Hz, 1 minute 2,000 VAC, 50/60 Hz, 1 minute 2,000 VAC, 50/60 Hz, 1 minute 2,000 VAC, 50/60 Hz, 1 minute 4

Structure and Nomenclature Structure -C000041 -BE2R041 -BM2B041 Three Positions: OFF - ON - OFF Position 1 Not Gripped Gripped to Middle Position Position 2 Position 3 Gripped past Middle Position Enabling Switch Section Emergency Stop Switch Section/ Switch Section OFF Gripped lightly Released ON Gripped Farther OFF Terminal 2 Terminal 3 Terminal 2 Terminal 3 Released Terminal 1 Terminal 4 Terminal 1 Terminal 4 Contact Configuration Enabling Switch Emergency Stop Switch Switch Terminal 5 Terminal 6 Terminal 5 Terminal 6 Terminal 8 Terminal 7 (2) (4) (6)* (5) (6) (5) (7) (6) (8) (1) (3) (5)* (7) (8) * (5), (6): -C000041 only Contact Forms Operating Patterns -C000041 Operation Enable output -BE2R041 -BM2B041 1 to 2 3 to 4 Grip output 5 to 6 Operation Enable output switch Emergency stop switch output Operation Enable output switch switch output 1 to 2 3 to 4 Position 1 Position 1 Position 2 Position 2 Position 3 Position 3 Operation Contact 5 to 6 7 to 8 1 to 2 3 to 4 Position 1 Operation (push) Reset (turn reset) Position 2 ON OFF OFF ON Position 3 Operation Contact 5 to 6 (pushbutton switch A) * 7 to 8 (pushbutton switch B) * Push Push OFF ON OFF ON * Refer to Dimensions on page 6 for information on the positions of pushbutton switches A and B. OPEN ON: CLOSED CLOSED OFF: OPEN Note: 1. The contact ON/OFF timing is not synchronized. Confirm performance before application. 2. Direct opening only during grip. Operating Characteristics Chart (Enabling Switch Section) Operating force OF2 OF1 HF Enable output (1-2, 3-4) Grip output (5-6) PT1 PT2 TT1 PT3 PT4 TT2 Operating stroke Operating Stroke (Enabling Switch Section) Operating characteristics Specified value Enable output (ON) PT2 max. 3.6 mm Max. enable holding position TT1 Approx. 4.2 mm Enable direct opening position PT3 max. 6.0 mm Max. stroke TT2 Approx. 6.7 mm Operating Force (Enabling Switch Section: Reference Values) Operating characteristics Specified value Enable operating force OF1 max. 14 N Enable holding force HF * Approx. 8 N Grip operating force OF2 max. 40 N * HF: Holding force Operating Force (Emergency Stop Switch Section: Reference Values) Operating characteristics Specified value Operating force OF max. 14.7 N Reset force RF max. 0.1 N m Operating Force ( Switch Section: Reference Value) Operating characteristics Specified value Operating force OF max. 4 N 5

Dimensions (Unit: mm) Enabling Grip Switches -C000041 Holding Key Mounted 60 (50) (34) 60 (50) (34) 174 174 (262) (277) 47.6 102.6 38 44 Conduit connector MG20A-P-13B Flexible Super Gland Manufactured by AVC Corporation of Japan (included) -OP3 Holding Key (order separately) 54.2 76.2 D4NS (order separately) 44 -BE2R041 Holding Key Mounted 63 (50) Emergency stop switch (34) 63 (50) Emergency stop switch (34) (191) 174 (191) 174 (279) (294) 47.6 102.6 38 44 Conduit connector MG20A-P-13B Flexible Super Gland Manufactured by AVC Corporation of Japan (included) -OP3 Holding Key (order separately) 54.2 76.2 D4NS (order separately) 44 6

-BM2B041 switch A (34) switch B 60 (50) (34) Holding Key Mounted 60 (50) (34) (189) 174 (189) 174 (277) (292) 47.6 102.6 44 38 44 -OP3 Holding Key (order separately) Conduit connector MG20A-P-13B Flexible Super Gland Manufactured by AVC Corporation of Japan (included) 54.2 76.2 44 D4NS (order separately) Accessories (Order Separately) Rubber Cover (Replacement Part) -OP1 Mounting Bracket (for Securing the ) -OP2 50 Two, 5.3-dia. holes (44) (88) (82) t3 Mounting surface Enabling Grip Switch Mounted 83.2 43.3 Holding Key -OP3 235.9 Note: The screws are not included. 7

Application Examples Application Examples Machining Equipment Maintenance Mode Switching between normal operation mode and maintenance mode is performed manually. In normal operation mode, the Safety Door Switch is enabled, and in maintenance mode, the Enabling Grip Switch is enabled. 2. Door 1. Emergency Stop Switch 2. Door 3. Enabling Grip Switch 4. Mode Selector 1. Emergency Stop Switch Emergency Stop Switch, e.g., A22E Guard Lock Safety-door Switch, e.g., D4NL Enabling Grip Switch Key-type Selector Switch A22K 4. Mode Selector 3. Enabling Grip Switch Basic Unit G9SX-BC Logical AND connection Safety Guard Switching Unit G9SX-GS Contactor Normal Operation Mode Emergency Stop Switch Door Enabling Grip Switch Maintenance Mode Emergency Stop Switch Door When pressed, processing will stop. When the door is opened, processing will stop. The Enabling Grip Switch will be disabled. When pressed, processing will stop. The Door Switch will be disabled. Conveyor Enabling Grip Switch Processing will be possible only when the operator is gripping the Enabling Grip Switch. Note: For information on the G9SX-GS, refer to G9SX-GS and G9SX User s Guide (Cat. No. Z255). 8

Wiring Example Settings (For details, refer to section 3 of the G9SX User s Guide (Cat. No. Z255).) G9SX-BC: Manual reset, cross fault detection: ON (category 4 wiring) G9SX-GS: Manual reset, cross fault detection: ON (category 4 wiring), logical AND connection setting: AND ON-delay time setting: Time is set. Switching mode: Manual External indicator diagnosis: Enabled Wiring Example Feedback loop S1 11 21 12 22 KM1 KM2 +24 V S2 +24 V Open A1 T11 T12 T21 T22 T31 T32 T33 Y1 G9SX-BC202 Control circuit KM1 KM2 M1 S1: Emergency Stop Switch S2, S7: Reset switches S3: Enabling Grip Switch S4: Guard lock Safety-door Switch S5: Lock release switch S6: Safety limit switch KM1 to KM4: Contactors M1 to M2: 3-phase motors A2 S14 S24 L1 L2 X1 X2 KM1 KM2 PLC etc. GND Lock release signal KM3 KM4 S5 S4 42 41 12 11 34 33 54 53 Door To PLC To PLC OPEN S6 Feedback loop Enabling Grip Switch S3 Mode selector Stop signal +24 V S7 KM3 KM4 +24 V Open Open A1 T11 T12 T21 T22 Y1 Y3 G9SX-GS226-T15 Control circuit Open Open +24 V M1 M2 T61 T62 T71 T72 Y2 Y4 T31 T32 T33 T41 T42 AND OFF Manual Auto KM3 KM4 A2 S14 S24 S44 S54 L1 X1 X2 X3 X4 UA UB M2 KM3 KM4 PLC etc. GND Indicator Indicator (Diagnostic check enabled) (Diagnostic check enabled) Note: For this circuit example, the category is equivalent to 4. 9

Timing Chart G9SX-BC202 (Upper Unit) Emergency stop switch S1 (10) Reset switch S2 KM1, KM2 NC contact KM1, KM2 NO contact Logical AND output L1 G9SX-GS226-T15 (Lower Unit) Logical AND input T41 Guard lock safety-door switch S4 (3) (8) Enabling grip switch S3 (4) (6) Reset switch S7 Mode selection input M1 (1) (2) (5) (7) (9) Mode selection input M2 KM3, KM4 NC contact KM5, KM6 NC contact KM3, KM4 NO contact KM5, KM6 NO contact OFF-delay time OFF-delay time OFF-delay time OFF-delay time (1) The lower unit starts in operation mode. (2) The mode switches to maintenance mode. (3) The operator opens the door and performs maintenance work. (4) The Enabling Grip Switch is gripped to the middle position. (5) The lower unit starts in maintenance mode. (6) The lower unit will stop when the Enabling Grip Switch is released or gripped. (7) The lower unit will start again after the door is closed and the mode is switched to operation mode. (8) The lower unit will stop when the door is open while in operation mode. (9) The door is closed and the lower unit starts again. (10) The upper unit and lower unit will stop if the emergency stop is pressed. 10

Safety Precautions!WARNING Always verify the operation of the safety functions before starting the system. Not doing so may result in the safety functions not performing as expected if the wiring or settings are incorrect or the switches have failed. Do not drop the switch. Doing so may damage the switch and the system may continue to operate, possibly causing injury or death. Do not contact the enabling switch section to the mounting bracket in Fig.2. Doing so may resoult in malfunction. Fig. 2 section Mounting bracket -OP2 (sold separately) Precautions for Safe Use This product is a switch for teaching the machine such as robot in hazardous area. The machine is allowed to operate only when operating the switch continuously. Configure the system so that the machine can be operated only at position 2. Apply load current not to exceed the rated value. Do not use the switch submerged in oil or water or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering the switch. Do not use the switch in locations where explosive or flammable gasses may be present. Mount the switch securely to prevent it from falling. Otherwise, injuries may occur. The durability of the switch is greatly influenced by the switching conditions. Always test the switch under actual conditions before application and use it in a switching circuit for which there are no problems with performance. Always attach the cover after completing wiring and before using the switch. Electric shock may occur if the switch is used without the cover attached. The user must not maintain or repair equipment incorporating the switch. Contact the manufacturer of the equipment for any maintenance or repairs required. Do not disassemble or remodel the switch in any case, or the switch will not operate normally. Do not override by inserting the Holding Key itself in the door switch. Configure the circuit so that the machine does not operate when operating the Enabling Switch while the Holding Key is being inserted in the door switch. Do not impose excessive vibration or shock on the Door Switch while the Holding Key is inserted. Excessive vibration or shock may cause the Switch to fail or break. Do not incline and pull the switch body or do not impose shock on the switch body in the directions shown with the arrows in Fig.1. Otherwise, the switch may be damaged and may not operate properly. Refer to the D4NS Safety-door Switch Datasheet and Instruction Sheet about the storage, ambient conditions, the details and handling of the Switch. Fig. 1 Insertion-pull direction (Perpendicular direction) Top position Precautions for Correct Use Do not hold the Enabling Switch Device at Position 2 by any other methods except for handling. Otherwise, the original function of the Enabling Switch Device is not worked. Operating Environment This switch is designed for use indoors. Using the switch outdoors may damage it. The switch contacts can be used with either standard loads or microloads. Once the contact be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced. Do not use the switch in the following locations. Locations where the interior of the Protective Door may into direct contact with cutting chips, metal filings, oil chemicals Locations subject to detergents, thinners, or other solvents Locations subject to sudden temperature changes Locations subject to high humidity and condensation Locations subject to severe vibration Do not use the switch where corrosive gasses (e.g., H2S, SO2, NH3, HNO3, or Cl2) are present or in locations subject to high temperature and humidity. Doing so may result in damage to the switch as a result of contact failure or corrosion. Do not store the switch where corrosive gasses (e.g., H2S, SO2, NH3, HNO3, or Cl2) or dust are present or in high temperature and humidity. If the switch is not turned ON and OFF for a long period of time, contact resistance may be increased or continuity failure may occur due to contact oxidation. Mounting Method Specified Tightening Torque Loose screws may result in malfunction. Tighten the screws at the specified torques. Item Cover mounting screw Terminal screw Holding Key mounting screw Conduit Connector mounting (Conforming spanner 27 mm (width across flats)) Mounting Bracket Specified torque 1.1 to 1.3 N m 0.4 to 0.5 N m 0.5 to 0.7 N m 2.0 to 2.4 N m 2.4 to 2.8 N m No operation No operation No operation No operation Arrow indicates insertion-pull direction. Cover Mounting Dislocation of the seal rubber or foreign substance on the seal rubber reduces seal performance of the switch. Mount the cover after confirming that there is no abnormality on the seal rubber. If the seal rubber cracks or breaks, replace the Cover with a new one (-OP1 Rubber Cover, separately sold). Do not touch the rubber boot with sharp objects. Otherwise, the rubber boot may break and the operating characteristics and the seal performance may not be satisfied. Holding Key -OP3 (sold separately) D4NS (sold separately) Magnified View Mounting surface Seal Cover, -OP1 (sold separately) Rubber boot Seal rubber 11

Installing Mounting Bracket Securely install the Mounting Bracket using M5 screws and washers and tighten them to a torque of 2.4 to 2.8 N m. Holding Key Type (sold separately) Use the -OP3 Holding Key when using the combining with the door switch. Use the D4NS Safety-door Switch. Loose screws may result in malfunction. Tighten the screws at the specified torques. Adhesive is recommended to prevent screws from being loose. The specified torque: 0.5 to 0.7 N m (Mounting screw, 2pcs.) Do not impose excessive force on the tip of the Holding Key or do not drop the switch body when the Holding Key is mounted on the switch body. Otherwise the Holding Key may deform or break. Stop using in case that deformation or breakage of the Holding Key occurs. Use the provide Spring washers and Mounting screws when mounting the Holding Key. Fit a tip of a slotted-screw driver on the head of the Mounting screw as shown in the following figure when tightening Mounting screws. The Mounting screws cannot be released once tightened. Holding Key -OP3 (sold separately) Spring washer, 2 pcs. (provided) Mounting screw, 2 pcs. (provided) As shown in figure 1 in Precautions for Safe Use, install the D4NS so that its mounting surface is above the highest part of the. As shown in figure 1 in the Precautions for Safe Use, use the Holding Key inserted vertically to the insert hole. Using the -BE2R041 (Enabling Grip Switch Equipped with an Emergency Stop Button) If the is installed in a machine, do not use the alone as an emergency stop switch or as an emergency shutoff switch as specified by SEMI-S2. SEMI-S2 specifies the installation of emergency shutoff switches at specified intervals on equipment. The can be removed from the equipment, and so may not satisfy the requirements of SEMI. Use the in combination with emergency stop switches or emergency shutoff switches that are installed at fixed positions. Wiring Confirm that safety is satisfied on the operation of the equipment to wire. Do not put the electric power when wiring. Otherwise electric shock may occur. Use an adequate diameter of cable. The seal performance is reduced when the diameter is smaller than the adequate diameter. Use the conforming sizes of lead wires to the apply voltage and current. Conforming cable size Recommended multi-wire cable size: AWG20 to 18 (0.5 to 0.75 mm 2 ) Recommended cable diameter: 8.0 to 13 mm (used with provided Conduit Connector) Do not pull the lead wires with excessive force. Doing so may disconnect them. Do not pull the cable when the Enabling Switch Device is hung on the Bracket. Use crimp terminals with insulator tube for wiring. Recommended crimp terminal (Ring tongue terminal, Nyloninsulated): J.S.T. Mfg Co. FN1.25-3.7 (F Type)/ N1.25-3.7 (Straight Type) t: 0.8 mm dz dia.: 3.7 mm D dia.4.0 mm B: 5.5 mm L: 15.7 mm F: 4.0 mm I: 9.0 mm Cut and crimp the lead wires in length as shown in the following table. Otherwise, excess length may cause the cover to rise and not fit properly. L2 D dia. Lead Wire Lengths L1 L F Bracket -OP2 (sold separately) Length of lead wires 1-4 5-8 L1/L2 40±2 mm 25±2 mm (Length to the centers of crimp terminals) Do not let particles such as small piece of lead wire in the switch body when wiring. and Circuit Configuration Model Circuit -C000041 Enable output 1-2, 3-4 Grip output 5-6 Enable output 1-2, 3-4 -BE2R041 Emergency Stop Switch output 5-6, 7-8 -BM2B041 Enable output 1-2, 3-4 Switch output 5-6, 7-8 Assemble all of the parts without leaving any parts as shown in the following figure when mounting Conduit Connector. Mount Rubber packing, Conduit part, Cable Seal part and Spiral Nut part in order. Both of the switches is ON when pushing the two push buttons simultaneously. Confirm that safety is satisfied on the operation of the equipment to wire. (-BM2B041) Perform maintenance inspections periodically. l dz dia. Terminal Arrangement Terminal 2 Terminal 3 Terminal 1 Terminal 4 Terminal 5 Terminal 6 Terminal 7 Terminal 8 B Rubber packing Cable seal part Spiral nut part Conduit part 12

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company 2009.11 In the interest of product improvement, specifications are subject to change without notice. AUDIN - http://www.ia.omron.com/ 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr (c)copyright OMRON Corporation 2009 All Right Reserved.