Model ES VA to VA SINGLE PHASE UNINTERRUPTIBLE POWER SYSTEM

Similar documents
Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

3 Uninterruptible Power Systems

SecureUPS On-Line 120V AC Output, 1300VA

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

Options & service. Additional 9355 options. Proven warranty and support services. Extensive service options for enhanced reliability.

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Onfiniti. 1 Phase UPS

3 Uninterruptible Power Systems

MKN-DSP SERIES - THREE PHASE

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Uninterruptible Power Systems

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Aurora Single Phase Emergency Lighting Inverters

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

TECHNICAL DATA SHEET KVA UPS Systemss

Series 120/120VAC Universal Tower/Rack Mount

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.0 GENERAL

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Liebert PowerSure PSI UPS

On-line, Single Phase, Double Conversion UPS

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

2033A Series. Where Reliability Breeds Confidence UNINTERRUPTIBLE POWER SUPPLY SYSTEMS ISO 9001 CERTIFIED

MINUTEMAN POWER TECHNOLOGIES Endeavor LCD Series Product Specifications 1000VA 3000VA Single-phase Uninterruptible Power Supply 1.

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

Eaton 9355 UPS. Scalable. Compact. Flexible.

Uninterruptible Power Systems

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

Liebert GXT4. Intelligent, Reliable UPS Solution 700VA - 3kVA

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

FN Series Scalable N+1 UPS 3kVA to 24kVA Rackmount

Illuminator Series CR NEMA 3R

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

D Series: UPS UPTO - 300KVA - Three / Three Phase

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

Technical Specification SENTINEL PRO

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Powerware series. Eaton 9155 UPS kva

Unity output power factor single-phase double-conversion, online UPS with advanced management features

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

Sola 3000 Guide Specifications

Smart UPS On Line 120/208 V

» Sophisticated» Reliable» Intelligent

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply

3 Uninterruptible Power Systems

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

Protection and conditioning against all forms of power anomalies.

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Smart-UPS On-Line 230 V

PowerValue 11/31 T kva

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Smart-UPS On-Line Lithium-ion UPS 230V

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

Features and Benefits

Uninterruptible Power Systems

POWERTRONIX QUASAR 5-40 KVA

TLE Series UPS 400/500 kw With eboost Technology

EFFEKTA Power Supplies

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

AT EVO SERIES BATTERY CHARGER

YOUR POWER IN SAFE HANDS. E Series UPS

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications

3 Uninterruptible Power Systems

Eaton 9PXM. 4-20kVA Split-Phase Rack-Tower UPS Guide Specification

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

Liebert GXT-MT 1-3kVA UPS. Power Protection for Business Critical Continuity

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Liebert GXT & 6000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Electric Power Marketing Spec Sheet Continuous Power Module CPM250

Security Plus Online Uninterruptible Power Supply

Transcription:

4500 VA to 15500 VA SINGLE PHASE Model ES UNINTERRUPTIBLE POWER SYSTEM True online double conversion design with a field-proven track record of protecting mission critical applications and preventing downtime. Applications: I.T. Network Server Rooms Small To Medium Data Centers Industrial Controls And Automation Healthcare I.T. Business Continuity Requiring Extended Runtimes Industry Leading 3-Year Warranty! UL 1778 C-UL Canadian National Standard C22.2, No. 107.1 M01 Product shown with standard casters and leveling feet.

PROVEN TECHNOLOGY + INNOVATION... Controlled Power Company engineers and manufactures the industry s highest quality uninterruptible power systems, capitalizing on 40 years of expertise. We have an enviable reputation for quality, which is reflected in the design, workmanship, and performance of our products. Our true online, double conversion UPS design is a field-proven Controlled Power Company standard, with a solid track record of protecting mission critical applications and preventing downtime. For you, this translates into trusted performance and reliability. From its aesthetically-pleasing innovative design... to its ease of installation and user-friendly operation, the Model ES UPS is the right choice to provide conditioned, continuous back-up power for today s mission critical applications. Product Snapshot Technology: True online, double conversion UPS, with automatic static bypass. Size Range: 4500 VA to 15500 VA single phase. *Input Voltage: 120, 208, 208/120, 220, 240, 240/120, 347, 480, or 600 *Output Voltage: 120, 208/120, 240/120, or 240/208/120 Output Performance: ±1.5% voltage regulation and zero transfer time to battery. Frequency: 60 Hz models, with input and output VAC listed above. 50 Hz models available. See Page 6 for input and output VAC configurations. Dimensions: UPS Cabinet Style S: 17 W x 36.5 D x 37.5 H UPS Cabinet Style T: 22.5 W x 36.5 D x 49 H Optional External Battery Cabinet: 22.5 W x 36.5 D x 49 H *Cabinet Style dependent on kva rating, battery run time desired, and input/output voltage configuration. *Battery Backup: Internal full-load runtimes from 5 to 70 minutes. Extended runtimes available from 1 to 5+ hours. *Output Distribution: Locking and non-locking receptacles and circuit breaker options. *See Pages 6, 7, and Back Cover for additional details. Choosing A New UPS? There are certainly a lot of choices. May we suggest a UPS that provides you with the following? Pq Extended battery backup time, without the need for additional cabinetry. Pq An internal computer-grade isolation transformer providing electrical noise attenuation and power conditioning. Pq Nominal input voltage options from 120 VAC to 600 VAC, with conversion to the exact nominal output voltage needed, even in bypass. Pq A secure maintenance bypass system that assures a fully in-sync transfer, and allows maintenance to be performed without shutdown. Pq An information-rich color monitor with an easy-to-use, high resolution touch-screen display. Pq Full network communications, including options for Ethernet TCP/IP, MODBUS TCP/IP, or MODBUS 485. Pq Output distribution options where you decide the exact receptacles and/or breakers supplied. If some or all of these features are on your must include UPS checklist... don t compromise! Choose the Model ES Uninterruptible Power System... the complete, integrated back-up power solution! 2 March 2011. Controlled Power Company. Intellistat TSTM and NetMinder TM are trademarks of Controlled Power Company.

= THE INTEGRATED, ONE-BOX UPS SOLUTION The Model ES UPS Information At Your Fingertips! Advanced Digital Monitoring --- The Intellistat TS TM The full-featured, user-friendly Intellistat TS TM monitor provides quick and easy access to the Model ES UPS s electrical parameters, system status, and event logs. The monitor displays operational conditions including system normal, percent battery capacity remaining, and battery test in progress. Alarm conditions are displayed on the screen, together with an audible alarm. A color, high resolution, LCD touchscreen display allows the entry of date / time values, system setpoints, alarm threshold settings, and password information into the monitor. The Intellistat TS provides complete system diagnostics, including user-programmable automatic battery testing and date / time stamped logging of the results. The Intellistat TS is an industry-leading UPS monitor and display that is information-rich, easy to use, and a welcome departure from mechanical pushbuttons, and traditional 2-row LED displays. Standard Communications For standard communications, the Model ES includes a hardwired terminal strip interface for remote indication of UPS on battery, low battery warning, on static bypass, and general alarm conditions. Relay contacts are potential-free, normally open, and rated for 120 VAC, 0.5 amps. These status and alarm contacts may be wired to a factory-provided Remote Annunciator panel with status LEDs and an audible alarm. Additionally, standard RS232 communications (via a USB port) allow access to electrical parameters, system status, alarms, system setpoint programming, and the test / alarm logs. The Intellistat TS s main status screen displays the power flow through the Model ES. Status bar graphs indicate the percent load and battery charge levels. Alarm indicators will be red in the event of overload or user-programmable low-battery conditions. A battery status indicator turns yellow when the UPS is on battery, or red if a weak battery condition is detected. A screen banner displays the UPS status. When the UPS is on battery, this screen banner also displays the elapsed time on battery. Optional NetMinder TM Communications NetMinder Slot Card The NetMinder Slot Card integrates the Model ES into an Ethernet TCP/IP, MODBUS TCP, or MODBUS RS485 network with a specific IP address. The NetMinder offers you remote monitoring of the UPS status, battery test pass/fail results, alarm conditions, and electrical measurements via a web browser, without the need for any external software. Remote notification of alarms and status are available to you via SNMP, e-mail, and network broadcast messaging. Temperature and humidity sensing interface are also available. NetMinder RCCMD Shutdown Software The NetMinder RCCMD is a client-side application that performs the orderly, unattended shutdown of your critical computers or servers. NetMinder UNMS II UPS Network Management System The NetMinder UNMS II is a Windows-based, server-side application that allows you to view and manage multiple, network-connected UPS s from a single computer. Using the Basic Version, you can monitor up to (9) UPS s... the Enterprise Version monitors even more UPS s, as well as environmental sensors or alarm contacts, and features a customizable graphical interface. Note: The NetMinder RCCMD and UNMS II both require using the NetMinder Slot Card option. The UNMS II option will monitor the status of not only Controlled Power Company s UPS s, but also those of other manufacturers. 3

total Power Security True Online Double Conversion With Static Bypass The Model ES is a true on-line double conversion ups. AC input power is converted to DC power to keep system batteries charged, then converted back to AC power to feed your mission critical equipment. Because the double conversion system reproduces its own regulated sinewave output, your equipment is no longer at the mercy of the input voltage distortions, frequency variations, voltage sags, surges, under-voltages, over-voltages, and power failures. This UPS topology assures a true no-break transfer to and from battery operation, eliminating the concern about transfer times and the reliability of standby circuits. In the event of an overload condition or a detected problem within the UPS, a static bypass switch automatically activates to maintain power to protected equipment. Adaptive Input Range Adaptive Input Range technology is used to automatically broaden the input operating range as a function of load. This feature provides added security during deep brownout conditions, without battery consumption. Dependent on the percentage of load, the input voltage can drop as low as 50% of nominal before resorting to battery power, thus increasing battery life. In addition, Adaptive Input Range assures that the batteries will be at full capacity for a real emergency... a power outage. Internal Shielded Computer-Grade Isolation Transformer A specially-designed internal shielded computer-grade isolation transformer is available to protect your mission critical equipment from voltage spikes, transients, and the detrimental effects of common mode noise. The transformer generates a new ground for your system; maintaining the integrity of a clean, noise-free reference for your critical loads, even in bypass. Internal transformer options are available to step line voltage up or down, and to convert 3-wire and 4-wire input configurations to match the exact needs of your protected equipment and satisfy output distribution requirements. An isolated output option of 240/208/120 VAC is available throughout the kva range of the product line. Also note that a single 120 VAC, 2-wire plus ground output can supply up to 11000 VA of uninterruptible power! Refer to the Voltage Configuration Charts on Page 6 for a complete list of options. Input Power Factor Correction With Less Than 5% THD The Model ES goes beyond a traditional double conversion UPS. The advanced bi-directional input power factor correction circuitry and independently-generated sinewave reference, guarantee that the input current is free of harmonics regardless of non-linear load currents or input voltage distortion. Secure Maintenance Bypass System Maintenance bypass systems ensure that critical loads are never disrupted during maintenance or in an emergency. Traditionally, maintenance bypass switches are activated manually; connecting the critical load directly to an alternate power source without synchronization. Activating an out-of-sync bypass may drop or damage the load, and may cause damage to the UPS. 4 The secure maintenance bypass system, exclusive to the Model ES, automatically invokes a synchronization command that forces the UPS to activate the static bypass first, before continuing to maintenance bypass mode. This system bypasses around the UPS electronics and controls, allowing for maintenance to be performed without shutdown or disruption of power to the load. If an internal isolation transformer is provided, the transformer is kept in the power circuit so that system isolation, voltage transformation, and power conditioning are maintained. The Model ES secure maintenance bypass system brings large system UPS features to mid-sized applications.

Specifications Power Ratings (VA) 4500, 5500, 6500, 7500, 8300, 9000, 10000, 11000, 12000, 13500, 14500, 15500 at 0.9 power factor Topology Electrical Input Nominal Voltage Voltage Range Operating Frequency Power Factor Current Distortion Electrical Output Nominal Voltage Voltage Regulation Frequency Overload Voltage Distortion Efficiency Battery Type Testing True online double-conversion UPS 120V to 600V available at 60Hz 220V to 415V available at 50Hz See Voltage Configuration Charts for options (Page 6) +12%, -15% at full load +12%, -40% at 53% load (without battery usage) +/-5% from nominal frequency online Corrected to >.98 typical < 5% THD 120V to 240 available at 60Hz 120V to 240V available at 50Hz See Voltage Configuration Charts for options (Page 6) +/-1.5% from nominal typical +/-0.5% while in battery operation mode 125% for 2 minutes, 150% for 30 seconds 3% maximum THD with a linear load 87% typical Valve-regulated, sealed lead calcium, maintenance-free Manual: Password-protected Automatic: User-programmable Runtime See Battery Runtime Chart (Page 7) Extended runtimes from 1 to 5+ hours available Nominal Voltage Charger 120 VDC 4-stage, temperature compensated 5 amp for battery options A and B 10 amp for battery options C through J Communications LCD Display High resolution, color touchscreen display for monitoring system status and parameters, and to access programmable UPS and battery testing Communication Port Serial communications via USB Network / Web Interface Relay Interface Emergency Shutdown Computer Shutdown Environmental Operating Temperature Optional slot card for remote monitoring and reporting via Ethernet TCP/IP, MODBUS TCP, or MODBUS RS485. Includes notification of alarms via SNMP, e-mail, and network broadcast messaging. Potential-free isolated status and alarm contacts via hardwired terminal strip. Contacts are normally open and rated for 120V, 0.5A Hardwired terminal connection for Remote Emergency Power Off (REPO) contact. Optional software for unattended graceful shutdown of critical servers 0 C (32 F) to 40 C (104 F) without derating Optimum battery performance and life at 25 C (77 F) Storage Temperature -20 C (-4 F) to 50 C (122 F) Battery storage at 25 C for 6 months. For each 9 C rise, reduce storage time by half. Relative Humidity Altitude Audible Noise Certifications 0 to 95% non-condensing 5000 feet (1500 meters) without derating 52 to 54 db, size and model dependent Safety UL 1778 C-UL Canadian National Standard C22.2, No. 107.1 M01 EMI Compliance Quality ISO 9001:2008 Markings FCC Part 15, Subpart J, Class A UL, C-UL General Diagnostics Static Bypass Maintenance Bypass Optional Isolation Transformer Output Distribution Continuous system self-check, including battery health Automatic bypass on overload or UPS failure Integral, wrap around, make-before-break switch with a secure push-to-turn function (Page 4) Internal shielded transformer available on all models provided in UPS Cabinet Style T (Page 6) Optional output circuit breakers and receptacles (Photo at right) See Output Distribution options (Back Cover) Dimensions / Weights See Page 6 for model dimensions. Weights are included in the Voltage Configuration Charts. See Back Cover for Output Distribution Options. Note: Standard casters not visible in photograph. 5

Voltage configurations Extensive Voltage Configurations The Model ES offers an extensive range of input voltages, providing an exact voltage to match your site and application. Whether on the plant floor, in the computer room, or at a remote location, the Model ES is capable of connecting to whatever voltage is available. It is not necessary to spend time and money to reconfigure your existing electrical system. The Model ES is capable of 60 Hz input voltage from 120 VAC to 600 VAC, or 50 Hz input voltages from 220 VAC to 415 VAC. Standard voltage configurations for 60 Hz models (both with and without an internal isolation transformer), and 50 Hz models are provided below. UPS Cabinet Style S: 17 W x 36.5 D x 37.5 H UPS Cabinet Style T: 22.5 W x 36.5 D x 49 H Optional External Battery Cabinet: 22.5 W x 36.5 D x 49 H For a thorough understanding of the following Voltage Configuration matrices, first consider your Input and Output VAC requirements. Then refer to the column of Output VA ranges to view the available sizes for your specific input and output voltages. Model ES Voltage Configurations 60 Hz Models without Internal Isolation Transformer Output VA 1 Input VAC Output VAC Weight UPS Cabinet Style w/o Batteries w/ Internal Battery 4500-5500 120 120 266 S or T 2 4500-11000 208/120 208/120 276 S or T 2 4500-11000 240/120 240/120 276 S or T 2 12000-15500 208/120 208/120 490 T 12000-15500 240/120 240/120 490 T 1 Output VA Sizes Available: 4500, 5500, 6500, 7500, 8300, 9000, 10000, 11000, 12000, 13500, 14500, 15500 2 UPS Cabinet Style T is optional to accommodate longer battery run times. Add 214 lbs if Cabinet Style T is selected. See Battery Run Time chart for options and battery weights (Page 7). Model ES Voltage Configurations 60 Hz Models with Internal Isolation Transformer(s) Output VA 3 Input VAC Output VAC Weight UPS Cabinet Style w/o Batteries w/ Internal Battery 4500-5500 120 240/208/120 4 600 T 4500-5500 208, 220, 240, 347, 480, or 600 120 625 T 6500-7500 208, 220, 240, 347, 480, or 600 240/208/120 4 755 T 6500-7500 610 8300-11000 208/120 or 240/120 240/208/120 4 650 T 12000-15500 208/120 or 240/120 240/208/120 690 T 4500-7500 635 8300-11000 208, 220, 240, 347, 480, or 600 240/120 650 T 12000-15500 690 3 Output VA Sizes Available: 4500, 5500, 6500, 7500, 8300, 9000, 10000, 11000, 12000, 13500, 14500, 15500 4 120V @ 100% rated load, 2-wire plus ground. See note in the Model Number Guide on the Back Cover. Model ES Voltage Configurations 50 Hz Models with Internal Isolation Transformer(s) Output VA 5 Input VAC Output VAC Weight UPS Cabinet Style w/o Batteries w/ Internal Battery 4500-5500 645 220, 230, 240, 380, 400, or 415 120 6500-7500 790 T 4500-7500 655 8300-11000 220, 230, 240, 380, 400, or 415 240/120 675 T 12000-15500 720 4500-5500 780 6500-7500 220 or 380 220 790 T 4500-5500 780 6500-7500 230 or 400 230 790 T 4500-5500 780 240 or 415 240 6500-7500 790 T 5 Output VA Sizes Available: 4500, 5500, 6500, 7500, 8300, 9000, 10000, 11000, 12000, 13500, 14500, 15500 6

Battery intelligence & Reliability Battery Management System --- We Do It Smarter! Batteries are the life-line of a UPS, and the key to the uptime of your networks and systems. Getting the greatest performance from your batteries requires knowing when to use the batteries, how low to discharge, and how to properly charge the batteries to quickly regain the stored energy for the next emergency. The Model ES battery management system meets these critical requirements by using a 4-stage, temperature-compensated battery charger for optimum control. Model ES Battery Run Times Options (In Minutes) Output Power UPS Cabinet Style S UPS Cabinet Style T UPS Cabinet Style T w/internal Battery w/ Internal Battery w/external Battery Cabinet VA Watt A B A B C D E F G H J 4500 4050 7 27 7 27 42 50 70 120 190 210 300 5500 4950 5 19 5 19 29 35 50 90 180 195 235 6500 5850 14 14 19 29 48 70 105 120 180 7500 6750 12 12 17 25 38 60 90 105 170 8300 7470 10 10 15 19 36 55 80 90 150 9000 8100 8 8 12 18 28 50 70 80 135 10000 9000 6 6 11 17 24 45 60 70 105 11000 9900 4 8 13 21 35 55 60 90 12000 10800 7 12 19 30 45 55 80 13500 12150 6 10 15 28 40 50 70 14500 13050 6 14 25 30 45 65 15500 13950 12 20 27 42 60 Battery Weights (See battery option letter; Indicator in the above matrix) A = 218 lbs B = 277 lbs C = 318 lbs D = 451 lbs E = 616 lbs F = 1297 lbs G = 1627 lbs H = 1743 lbs J = 2238 lbs Notes: For total UPS system weight: Add the selected battery option weight above, to the UPS unit weight w/o batteries (Page 6). Battery options F through J require an external battery cabinet, together with UPS Cabinet Style T. The external battery cabinet matches the dimensions of the UPS Cabinet Style T (22.5 W x 36.5 D x 49 H). To account for total shipping weight, add 60 lbs to options A - E above, and add 120 lbs. to options F - J. Longer battery run times are available other than those listed above. Battery options are also available for in computer room installations. Consult factory for details. Product Snapshot Heavy-duty casters and adjustable leveling feet are provided for ease of installation and placement. UPS Cabinet Style T and matching external battery cabinets are designed with slide-out battery trays for ease of maintenance. Side access is not required for system installation, operation, or service. Note: UPS Cabinet Style S requires right side access for normal service and battery replacement. UPS Cabinet Style T shown with one (1) matching, external battery cabinet. This configuration accommodates battery options F through J in the above matrix. For illustration purposes, battery cabinet is shown with front panel removed and bottom battery tray partially slid out. 7

Model Selection guide OUTPUT DISTRIBUTION & MODEL NUMBER GUIDE Model ES Output Distribution Options Receptacle Breaker / Pole Voltage Phase 5-15R2 6 15A / 1P 120V 1 5-20R2 6 20A / 1P 120V 1 L5-20R 7 20A / 1P 120V 1 L5-30R 7 30A / 1P 120V 1 L6-20R 7 20A / 2P 208 or 240V 2 L6-30R 7 30A / 2P 208 or 240V 2 L14-20R 7 20A / 2P 240/120V or 208/120V 2 L14-30R 7 30A / 2P 240/120V or 208/120V 2 6 Non-Locking Type, Duplex (2 outlets per receptacle) 7 Locking Type Available on UPS Cabinet Style S Breaker with Receptacle: Maximum of 3 Non-Locking Receptacles and 4 Locking Receptacles Breaker Only Option for Hardwire Connection: Maximum of 8 Poles Available on UPS Cabinet Style T Breaker with Receptacle: Maximum of 4 Non-Locking Receptacles and 6 Locking Receptacles Breaker Only Option for Hardwire Connection: Maximum of 16 Poles Note: IEC 320 outlets and 50 amp receptacle options are available. Consult factory. The following Model Number Guide is for Model ES product offerings. Refer to the Voltage Configuration Charts on Page 6, for the appropriate input and output voltage combinations. Model ES 4500 VA - 15500 VA UPS Model Number Guide Product Input Voltage Output Voltage Freq VA UPS Cabinet Style Battery Option ES A = 120 A = 120 X = 60Hz 4500 S A B = 208 L = 208/120 W = 50 Hz 5500 T B L = 208/120 I = 220 6500 C I = 220 U = 230 7500 D U = 230 C = 240 8300 E C = 240 G = 240/120 9000 F G = 240/120 Z = 240/208/120* 10000 G V = 347 11000 H Q = 380 * On models rated 11000 VA and below, Z output 12000 J R = 400 configurations are 13500 F = 415 designed for full load at 120 VAC, 14500 D = 480 2 Wire + Ground. 15500 E = 600 Example: ES-DGX-12000-TE Model ES UPS with a 480 VAC input, 240/120 VAC output, 60 Hz, 12000 VA output power rating, Cabinet Style T, with 19 minutes of battery (internal) run time at full load. Warranty: Controlled Power Company guarantees the UPS electronics and controls to be free from defects in material and workmanship for a period of (3) years following shipment from the factory. Battery warranty is 2-year full replacement. On-site labor for warranty repair in the United States and Canada is covered for 90 days following shipment from the factory. Contact Factory for Statement of Warranty details, and ask about our Start Up Plus service and Warranty Upgrades! Represented by: 1955 Stephenson Hwy., Troy MI 48083 www.controlledpwr.com email: info@controlledpwr.com Phone: (800) 521-4792 Fax: (248) 528-0411 All information and data within this brochure is subject to change without notice. ES-001-0311