Safety Precautions Product Contents Product PIN Diagram LED indicators Product Dimensions Installation of Panel with Casing Wire Legend Power Wiring

Similar documents
INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

Zodiac Max INSTALLATION MANUAL

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

USERS MANUAL MCD REMOTE OPERATOR

INTECH Micro 2300-RTD6

Connection. 1. Diagnostic socket 2. Adaptor 3. Main cable 4. PC-MAX main unit 5. PC 6. Wireless adaptor

CAN-Translator. User s guide

BYD Battery-Box HV User Manual Battery-Box H 5.1/6.4/7.7/9.0/10.2/11.5

Mobile Access, TimeTec Smart Tripod Turnstile TTS 2200B Installation Manual

BMS24. Thanks for your purchasing the BMS24 for your vehicle.

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

MAPNET II Transceiver Installation Instructions

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

ET9500 BEMS Interface Box Configuration Guide

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

SNMP dedicated to ORVALDI Solar Infini

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Expansion Signal (XSIG) Card Installation Instructions

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

MR16out Processor Installation and Specifications

SR8-Plus 2 Phase Step Motor Drive

PTZDECO241 Pan/Tilt/Zoom RS-485 receiver. Please read this manual carefully before use product!

GloboFleet. User Manual EAN / GTIN GloboFleet Downloadkey II

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

Invensys (Foxboro) IMV25 Multivariable Setup

BMS16. Thanks for your purchasing the BMS16 for your vehicle.

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

Model No. PS-2000 WARRANTY AND OPERATING INSTRUCTIONS

PKS-FD Servo System

Wind display type WSDI-2

User Manual. Solar Charge Controller 3KW

The Battery is a client module in the Cabinet Control. It is a backup/ups module which

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

CX-SERIES ADVANCED BATTERY CHARGER

SKC400U SLIDING GATE OPENER OWNER S MANUAL

KNC-PKS-FD S-AAK-DKH

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

KNC-SRV-FD123-CA-000 Series Servo Driver

DL300 FINGERPRINT LOCK

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

User Manual 1KVA-5KVA INVERTER / CHARGER

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

MagFlux Q 8200 Series

RS485 MODBUS Card. User Manual. Before you start to install this card, please read this User Manual carefully

User Manual Solar Charge Controller 3KW

GFX2000. Fuel Management System. User Guide

Installation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents

Ultrasonic Fuel Level Sensor

AX-LR904. Land Rover LR2 (with NAV, with M.O.S.T. 25 amplifier) Data Interface with SWC & Factory Display Retention

INSTALLATION USER MANUAL

Fingerprint/Card Terminal AC-6000 V2.0

Hi-Z USB Wireless. Introduction/Welcome

10KW Portable EV Charger

Lithium-Iron Phosphate Battery US2000B Product Manual

GLM SERIES CONTROL Users Manual Rev:

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use

UPS2000-G-(1 kva-3 kva) Quick Guide. Issue: 05 Date: HUAWEI TECHNOLOGIES CO., LTD.

Speed Dome 66 Installation Manual

MondoStep 7.8. High Performance Microstepping Driver. User s Manual. Version PROBOTIX All Rights Reserved

Dominion PX. Quick Setup Guide. Before You Begin. Mounting Zero U Models Using L-Bracket. Zero U Size. 1U and 2U Size

ZT-USB Series User Manual

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

Photovoltaics. MPI Hybrid Series

Wide Bank 28 DS3 QUICK START GUIDE

T H E K A n t r a k S E R I E S D I S P L A Y I N S T A L L A T I O N M A N U A L

6K-SSR-RACK08 Specifications

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

Induction Power Supplies

USER GUIDE KAS-840-DEN KAS-850-RDEN

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

Subject Underhood G System Error Codes and Symptoms System or Parts affected

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

SDOMEO51MV USER MANUAL. Portable Rugged PTZ Cameras

Operating Manual For Stepper Driver

ABB Component Drives ACS150, 0.5 to 5 Hp

Flex Amplifiers Installation Instructions

Uninterruptible Power System

MALLORY FIRESTORM CD MULTI COIL HARDWARE INSTALLATION - PN 69150C / 69150R

L300P Inverter Specifications

KNC-SRV-FD123-EA-000 Series Servo Driver

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

SentryGOLD Compact. for Bennett Electronic Dispenser INSTALLATION MANUAL. Fuel Management System

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

B-Box Pro 2.5~10.0 User Manual

MME/MOE Intelligent Electric Actuators About Ontrac

1 EX5. Technical Characteristics. Dimensions

QT CARTS PROGRAMMING AND TROUBLESHOOTING GUIDE FOR ELECTRONIC OR PROXIMITY LOCKS

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

USER GUIDE KAS-840-DEN KAS-850-RDEN

INSTALLATION MANUAL KAntrak 1700

Motorized Stainless 2-Way Valves

AX-LR903. Land Rover Range Rover Evoque (with M.O.S.T. 25 amplifier) Data Interface with SWC & Factory Display Retention

Transcription:

www.zkteco.com

Safety Precautions Product Contents Product PIN Diagram LED indicators Product Dimensions Installation of Panel with Casing Wire Legend Power Wiring Diagram FR1200 Connection Weigand Connection Exit button Connection Lock connection Door Sensor Connection Aux. Input Connection Aux. Output Connection Ethernet Connection RS485 Connection DIP switch settings Electrical Specifications Troubleshooting Specifications 1 02 04 06 06 07 08 09 10 11 12 12 13 13 15 15 16 17 18 19 20 21

1 Safety Precautions 2 The list below is to keep user s safety and prevent any loss. Please read carefully before installation. 01 02 03 Do not install the device in an area subject to direct sun light, Humidity or dust Do not place a magnet near the product. Magnetic objects such as magnet, CRT, TV, monitor or speaker may damage the device. Do not place the device next to heating equipments 04 05 06 Be careful not to let liquid like water, drinks or chemicals leak inside the device. Clean the device often to remove dust on it Do not let children touch the device without supervision.

Safety Precautions The list below is to keep user s safety and prevent any loss. Please read carefully before installation. 07 08 09 Do not drop the device. Do not disassemble, repair or alter the device. Do not use the device for any other purpose than specified. 10 11 12 Do not damage the device In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. 3 Contact your nearest dealer in case of a trouble or problem.

Product Contents Basic Contents Wall Mounting Screws 2 pcs. Wall Plugs 2 pcs. Surge Suppressing Diode 4 pcs. Screw Driver 2 pcs. Software CD InBio Installation Guide Inbio460 4

Product Contents 5 Optional accessories Weigand Card Reader Prox Card FR1200 FP Reader K1-1 Exit Button ZK4500 FP Enrollment reader Card Enroller Inbio Metal Case RS485 convertor

6 Product PIN Diagram SD Card Slot LED indicators LINK LED Ethernet Port ACT LED DIP Switch PC RS485 Port Aux Input 1 Aux Input 4 FR1200 Fingerprint Reader LINK (Green) ACT (Yellow) LED solid green indicates TCP/IP communication is normal Flashing LED indicates data communication is in progress Aux Output 1 Aux Output 4 #1 Door Sensor #1 Door Lock State Indictor #1 Door Exit Button #1 Door Card Reader #2 Door Exit Button #2 Door Card Reader EXT RS485 (Yellow & Green) PC RS485 (Yellow & Green) Flashing LED indicates data communication in progress Flashing LED indicates data communication is in progress #4 Door Sensor #4 Door Lock Lock Power Inbio Power #3 Door Exit Button #3 Door Card Reader #4 Door Exit Button #4 Door Card Reader POWER (Red) RUN (Green) Flashing LED indicates the panel is powered on. Flashing LED indicates that panel is in normal working mode CARD (Yellow) Flashing LED indicates that the card is read by the panel.

Product Dimension Inbio460 226mm (8.89in.) InBio-Casing 106mm (4.17in.) 106mm (4.17in.) 36mm (1.42in.) Dimensions(L*W*H):226 106 36(mm) 8.89 4.17 1.42(inches) 330mm (13.0in.) 330mm (13.0in.) 90.5mm (3.56in.) 400mm (15.7in.) 7 Dimensions(L*W*H): 400 *90.5*330(mm) 15.7 13.0 3.56(inches)

Installation of Panel & Case 8 Metal Case

Wire Legend Detector Infrared sensors FR1200 Inbio-Box #1Exit Button #1Card Reader #4 Exit Switch #4 Card Reader DC 12V DC Power 12V Network RS485 Convertor Floodlight Alarm 9 Normally Close Lock Normally Open Lock Power Supply

Power wiring diagram 10 Without Backup Battery AC 110-220V Inbio460 AC Switching power supply With Backup Battery AC 110-220V Inbio460 + Backup Battery - AC Switching power supply

FR1200 Connection 11 12V DC 12V DC #1 FR1200 #2 FR1200 #3 FR1200 #8 FR1200 DIP Switch Setting For FR1200 Device ID Important Notes 1. There are six DIP switches on the back of FR1200, Switches 1-4 is for RS485 address, switch 5 is reserved, switch 6 is for reducing noise on long RS485 cable. 2. Set the odd number for IN reader, and the even number for OUT reader(for eg. For two readers for one door- the RS485 address 1 is for IN reader, RS485 address 2 is for OUT reader ) 3. If FR1200 is powered from Inbio460 panel,the length of wire should be less than 100 meters or 330 ft. 4. The External RS485 interface can supply maximum 500mA current, The FR1200 s startup current is 240mA. So Inbio460 only can only power two FR1200s. 5. If the cable length is more than 200 meters or 600 ft, the number 6 switch should be ON as below Distance More than 200 meters

Weigand Connection 12 Beeper Green LED Weigand D1 Weigand D0 GND DC+(6-14V) Weigand Card Reader Exit Button Connection 12V DC Power Supply DV12V(+) DV12V(-) BUT GND NO COM NC ZK ABK Exit Button Notice: separate power supply K1-1 Exit Switch

Lock Connection 13 For Normally Open -Lock powered from panel power supply FR107 GND 12V DC Sensor Sensor GND 12V DC For Normally Closed -Lock powered from panel power supply FR107 12V DC GND Sensor Sensor GND 12V DC

Lock Connection Switching Wet Contact to Dry Contact Important Notes: Steps: InBio is set to supply lock power by default from built-in power supply, If you want to use external power supply, you must take the following steps 1. Take apart the cover of inbio460 2. Select the desired lock relay and find its jumpers 3. Take off the jumpers and change to 4. Connect the lock as shown in the diagram below. Inbio460 Detach from Rail Remove Top Cover Lock Relay 5 1 5 1 5 1 5 1 Changed Setting Jumpers Terminals Default Setting Connecting a Lock with External Power supply GND 12V DC FR107 14 SEN SEN GND 12V DC

Auxiliary Input/Output 15 Aux. Input Connection Smoke Detector 12V DC GND COM NO NC Aux. output Connection Alarm 12V DC GND COM NO NC

Ethernet Connection 16 Important Notes: ZK4500 Enrollment reader CR10 Card Issuer The CR10 and ZK4500 are connected to the server using USB connection. TCP/IP 1. Both 10Base-T and 100Base-T are supported 2. The cable length must be less than 100 meters or 330 ft. 3. For more than 100 meters, please use HUB to amplify the signal Direct connection To connect Inbio460 with a PC directly, connect both devices with a straight network cable. As the Inbio460 supports auto MDI/MDIX, it is not necessary to use a crossover type cable. ZK4500 Enrollment reader CR10 Card Issuer

RS485 Connection 17 #63 Inbio460 #1 Inbio460 RS485- RS485+ GND Important Notes Do's and Dont's for RS 485 connection 1. RS485 communication wires should be a shielded or twisted pair cable. RS485 communication wires should be connected in a bus cascade instead of a star form, to achieve a better shielding effect by reducing signal reflection during communications. 2. A single 485 bus can be connected with 63 access control panels at the most, but preferably less than 32 panels should be connected. 3. To eliminate signal attenuation in communication cables and suppress interference, if the bus is longer than 200 meters, set the number 8 DIP switch to the ON position. This is equivalent to a parallel connection of one 120ohm resistance between the 485+ and 485- lines. Distance More than 200 meters #1 Inbio460 #* Inbio460

DIP Switch Setting 18 Introduction RS485 Address 1. Number 1-6 are reserved to set the device number for RS485 communication. The code is binary, and the numbering starts from left to right. When the switch is set to ON position, it indicates 1 (on); when the switch is set downwards, it indicates 0 (off). For example, to set a device number 39=1+2+4+32, which corresponds to the binary code 111001, put number 1, 2, 3, and 6 to ON position, as illustrated below. 2. For more details, please check the table at the end of this document Restore factory setting Terminal Resistance 1. If you forget the inbio IP address or the device does not work normally, you can use the number 7 terminal to restore inbio460 to factory default settings. The parameters which gets reset are device IP address, communication password,gateway,subnet mask. 2. The switch is OFF by default. When it is moved upwards and downwards for three times within 10 seconds and finally returned to OFF position, the factory settings will be restored after the access control panel is restarted. 1 times 2 times 3 times OFF 1. Number 8 is for setting the RS485 termination resistance. Putting the switch to ON position is equivalent to parallel connection of a 120ohm termination resistance between 485+ and 485-2. As shown in diagram below, for more info please read RS485 connection important notes 120ohm

Electrical Specification 19 Min. Typ. Max. Notes Working power supply Voltage(V) 9.6 12 14.4 Use regulated DC power adaptor only Current(A) 2 Electronic lock relay output Switching voltage(v) 36V Use regulated DC power adaptor only Switching Current(A) 2 Auxiliary relay output Switching voltage(v) 36V Use regulated DC power adaptor only Switching Current(A) 1.25 Switch Aux. input VIH (V) VIL (V) TBD TBD Pull-up resistance (Ω) 4.7k The input ports are pulled up with 4.7k resistors WEIGAND Input Voltage(V) 10.8 12 13.5 Current(mA) 500 ZK Electronic lock Voltage(V) 10.8 12 13.2 Current(mA) 500

Troubleshooting 20 1. Fingerprint can not be read well or it takes too long. Check whether a finger or fingerprint sensor is stained with sweat, water, or dust Retry after cleaning the finger and fingerprint sensor with dry cloth. If a finger is way too dry, rub your finger on the palm and retry. Try to reset fingerprint sensor by pressing the reset button at the bottom of the reader Reset Button 2. Fingerprint is matched but authorization keeps failing. Check whether the user access is restricted. Inquire with administrator whether the enrolled fingerprint has been deleted from the device for some reason. 3. How Many kinds of WEIGAND format can be supported. The panel is set to read 26 bit by default. However there are 9 other bit formats which can be selected from the software. In addition you can also define your custom bit format. 4. How many verification modes can be support. Card Only Fingerprint Only Password Only Card plus fingerprint Card plus password Card or fingerprint

Specification 21 Communication RS485, Ethernet Baud Rate for RS485 9600-115200 baud Power Supply 12V DC, 3A Device Capacity Card capacity 30,000 ; Log events capacity 100,000 ; Finger capacity 3,000 LED Indicator Indication for communication, power, status and prox card Environment Operating Temp: 32-113 F (0-45 C) Operating Humidity: 20% to 80% Number of doors controlled four door one way or two door two way Number of card readers supported 4 Number of FR1200 supported 8 FR1200 Sensor Fingerprint sensor 500dpi Optical / Optical sensor Types of readers supported 26-bit Weigand, others upon request Number of Inputs 12 (4 Exit Device, 4 Door Status, 4 AUX) Number of Outputs 8 (4- Form C relay for lock and 4- Form C relay for Aux output) Weight 7.8lbs (3.55kg) Enclosure Stainless Steel Mounting Wall Mount Dimensions (Bundle Only) 15.7in. 3.56in. 13.0in. 400mm(L) X 90.5mm(W) X 330mm(H) Dimensions ( Board Only) 8.89in. 4.17in. 1.42in. 226mm(L) X 106mm(W) X 36mm(H) CPU 32 bit 400MHz RAM 32MB Flash 128MB Certified

PC485 Table 22 Switch Setting Switch Setting Place Address 1 2 3 4 5 6 Place Address 1 2 3 4 5 6 Address No. 1 2 4 8 16 32 01 ON OFF OFF OFF OFF OFF 02 OFF ON OFF OFF OFF OFF 03 ON ON OFF OFF OFF OFF 04 OFF OFF ON OFF OFF OFF 05 ON OFF ON OFF OFF OFF 06 OFF ON ON OFF OFF OFF 07 ON ON ON OFF OFF OFF 08 OFF OFF OFF ON OFF OFF 09 ON OFF OFF ON OFF OFF 10 OFF ON OFF ON OFF OFF 11 ON ON OFF ON OFF OFF 12 OFF OFF ON ON OFF OFF 13 ON OFF ON ON OFF OFF 14 OFF ON ON ON OFF OFF 15 ON ON ON ON OFF OFF 16 OFF OFF OFF OFF ON OFF 17 ON OFF OFF OFF ON OFF 18 OFF ON OFF OFF ON OFF 19 ON ON OFF OFF ON OFF 20 OFF OFF ON OFF ON OFF 21 ON OFF ON OFF ON OFF 22 OFF ON ON OFF ON OFF 23 ON ON ON OFF ON OFF 24 OFF OFF OFF ON ON OFF 25 ON OFF OFF ON ON OFF 26 OFF ON OFF ON ON OFF 27 ON ON OFF ON ON OFF 28 OFF OFF ON ON ON OFF 29 ON OFF ON ON ON OFF 30 OFF ON ON ON ON OFF 31 ON ON ON ON ON OFF 32 OFF OFF OFF OFF OFF ON Address No. 1 2 4 8 16 32 33 ON OFF OFF OFF OFF ON 34 OFF ON OFF OFF OFF ON 35 ON ON OFF OFF OFF ON 36 OFF OFF ON OFF OFF ON 37 ON OFF ON OFF OFF ON 38 OFF ON ON OFF OFF ON 39 ON ON ON OFF OFF ON 40 OFF OFF OFF ON OFF ON 41 ON OFF OFF ON OFF ON 42 OFF ON OFF ON OFF ON 43 ON ON OFF ON OFF ON 44 OFF OFF ON ON OFF ON 45 ON OFF ON ON OFF ON 46 OFF ON ON ON OFF ON 47 ON ON ON ON OFF ON 48 OFF OFF OFF OFF ON ON 49 ON OFF OFF OFF ON ON 50 OFF ON OFF OFF ON ON 51 ON ON OFF OFF ON ON 52 OFF OFF ON OFF ON ON 53 ON OFF ON OFF ON ON 54 OFF ON ON OFF ON ON 55 ON ON ON OFF ON ON 56 OFF OFF OFF ON ON ON 57 ON OFF OFF ON ON ON 58 OFF ON OFF ON ON ON 59 ON ON OFF ON ON ON 60 OFF OFF ON ON ON ON 61 ON OFF ON ON ON ON 62 OFF ON ON ON ON ON 63 ON ON ON ON ON ON

Functions and specifications of the product are subject to change without notice due to quality enhancement or function update. For any inquiry for the product, please contact ZKTeco Inc. Copyright 2013 ZKTeco Inc. All right reserved. ZKTeco May, at any time and without notice, Make changes or improvements to the product and services offered and/or cease producing or commercializing them. ZK China : ZK Building, Wuhe Road, Gangtou, Bantian, Buji Town, Longgang District, Shenzhen China. Tel.: +86 755-89602345 sales@zkteco.com zkteco.com