Installer s Manual. PCO/UV N-Duct Model

Similar documents
Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

MINISTICK TM UV Germicidal Ultraviolet Light

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

21", 33", 45", & 61" Installation & Operation Manual

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

Safety, Installation and Service Manual Models 1952, 1953 & 1972

HARDWARE KIT INSTALLATION GLOVES

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

WARRANTY. Air flow. (Please note standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

Installation & Maintenance of the Fresh-Aire UV Tubular Rack System for Commercial Air Handler Systems

UV-AIRE AIR PURIFYING SYSTEM

INSTALLATION TEMPLATE

INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

LUNA Air for life. Featuring: NASA Developed Technology. Owner s Manual. Photocatalytic Oxidation Induct Air Purification System.

APCO Rack System. A unique solution for the elimination of viruses, bacteria and VOC s. and saving energy FRESH-AIRE UV

MCI. SynAIRgPURE. Owner s Manual

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

INSTALLATION, MAINTENANCE & OPERATION GUIDE. MODEL Sanuvair S300 WHOLE HOUSE HEPA/UV AIR PURIFIER. ITEM # Sanuvair S V EN

UV-AIRE AIR PURIFYING SYSTEM

PHOTO-CATALYTIC AIR PURIFIER SYSTEMS

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Ultraviolet Systems RXIU-A02A, RXIU-A03A TREATMENT SYSTEMS

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

COILCARE PM. Installation Instructions and Operating Manual. CoilCare Series BioZone Scientific International, Inc.

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

Automatic Emergency Light

CAUTION: Read manual carefully for proper procedures and operation.

Document No D1 Revised December Atlantic Ultraviolet Corporation

gamma uv Aquarium Ultraviolet Sterilizers

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Further information: Berriman Associates Model 850P.2 Owners Manual

CRD610 Automatic Fitting Inserter

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

CRD400 Fitting Inserter OPERATIONS MANUAL

MODEL 950C-NP-UV Installation and Owners Manual

PUSH BUTTON KEY CABINET

User s Manual and Operating Instructions

SPH-400 i Series General Manual

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

Remove packaging and place your SunTouch Plus on a level surface.

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

INSTALLATION & OWNER'S MANUAL

Level One Electric Vehicle Charging Station Wall Mount Product Guide

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

CRD600 Automatic Fitting Inserter

HQUA. UV Water Sterilizer Instruction Manual. Contents

Source Capture Air Purification System

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

VH03 SAVE THESE INSTRUCTIONS

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Users Guide for Ac-sync

Owner s Guide ca4054 ca4554

Microscope light manual

Installation / Operation Instructions Sunnex ORION Series Exam Lights

4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Use and Care Guide.

UNPACKING THE UNIT. Alcohol cleaning pad

Swing Arm Magnifying Lamp

Roller Door Operator

Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System For PTAC & ETAC Units

For Mini Split Units. Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System

IMPORTANT: SAFETY INSTRUCTIONS

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

IMPROVED BUTTON CONTROLS NEW TOMAHAWK USER MANUAL

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

LIBERATOR USER MANUAL

CLEAN POWER TM CPS Series Operator s Manual

ULTRAVIOLET WATER DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL

Submersible Pond Pump with UV 800 Gallons Per Hour

RF6 / RF10 / RF18 Installation Instructions

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information

NANOpure Infinity UV Module Upgrade

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

E24-E28 M88 & S38 Mass Air Flow Conversion System Instruction Manual

INSTALLATION INSTRUCTION & OWNER S MANUAL

6 OFF ROAD LIGHT BAR

SunMaster Shadow. Care and Use Guide. Important! Read this manual before installing, operating or servicing this product.

Portable Sanitizing Wand. Model: VH03. The CleanWave Portable Sanitizing Wand kills up to 99.9% of germs and odorcausing. surfaces.

"WHERE TUBING AND FITTINGS COME TOGETHER"

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

USER S MANUAL & WARRANTY INFORMATION

UV Flood Curing System

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

Model P-40 & Model P-25 POWER PUSHER

SUBMERSIBLE MINI-PUMP

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

UV100A Ultraviolet Systems UV100A1000 AND UV100A1018 AIR TREATMENT SYSTEMS UV100A1059 AND UV100A2008 SURFACE TREATMENT SYSTEMS

Escort Stair Lift. Owner's Manual

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

Transcription:

Installer s Manual PCO/UV N-Duct Model

FACTS ABOUT THE PCO/UV N-DUCT UNIT AirGorilla combines the power of two highly regarded contaminant fighting technologies - ultraviolet light and PCO (photocatalytic oxidation). The PCO/UV N-Duct utilizes two, Dual-Radiant germicidal ultraviolet lamps that produce a total of 210 microwatts of contaminant killing power (measured at 1 mtr.). In addition, the UV lamps illuminate a unique photocatalytic filter of nano-technology titanium dioxide that provides higher levels of destruction and on a broader range of contaminants. As air circulates through the air duct system and passes the PCO/UV N-Duct unit, these powerful technologies destroy airborne bacteria, mold, fungi, viruses, volatile organic compounds (VOC's) & odors. IMPORTANT POINTS FOR THE INSTALLER AirGorilla s PCO/UV N-Duct unit is designed for ease of installation and service. Cut just one hole and install. The unit never needs to be un-installed to replace the UV lamps. Simply open the door and change them out. And thanks to the innovative Display Panel and micro-circuitry, there is no guesswork if the UV lamps are working or if they need to be replaced. INCLUDED IN THIS BOX PCO/UV N-Duct System with PCO Filter Attached 2 Dual-Radiant Ultraviolet Lamps Mounting Template Installation Manual Owner s Guide TOOLS/SUPPLIES REQUIRED FOR INSTALLATION Installation into Metal Duct or Plenum Installation into Ductboard Metal Cutting Snips Ductboard Knife Electric Drill Duct Tape (or screws/nuts if using Sheet Metal Screws metal mounting brackets) Wire Cutters Wire Cutters UV Eye Protection UV Eye Protection BEFORE INSTALLING Read all instructions carefully Be attentive to all warnings and cautions Installation should only be performed by a qualified installer 1

OVERVIEW OF THE PCO/UV N-DUCT Photocatalytic Oxidation (PCO) Filter 187 square inches of nano-technology titanium dioxide mesh produces maximum destruction of airborne contaminants with negligible air resistance. It never needs cleaning or replacing. Replace #1 UV Lamp top UV lamp needs to be replaced #1 UV Lamp On top UV lamp is lit and operational POWER ON indicates the unit is receiving electrical power #2 UV Lamp On bottom UV lamp is lit and operational Two, 36 watt, Dual-Radiant Lamps Provides over 5 times the killing power of the typical, ultraviolet systems. Replace #2 UV Lamp bottom UV lamp needs to be replaced AUDIBLE ALERT the PCO/UV N-Duct unit is often installed in areas not readily visible to the owner and therefore the Replace Lamp LED may not be seen when lit. When the UV lamps need to be replaced, an audible alert will also be sounded (a continuous beep) to notify the owner of the need to replace the lamps. Lamp Retaining Swivel Clamp Lamp Insertion Portal Cover for Ballast and PCBs 2

SPECIFICATIONS Dimensions Mounting Plate: 7 x 13 PCO Filter: 11 x 17 UV Lamp: 1.75 x 16.25 Duct mounting hole: 5 x 11 Weight Complete Unit: 4 lbs. Electrical 120V-277V, 50/60Hz Powercord - 9 ft., 3 prong, rated to 240V UL Listed Electronic Ballast UV Lamp 36 watt, 105 w/cm 2 @1 mtr. Material Mounting Plate and Enclosure - Fire Retardant ABS INSTALLATION IMPORTANT This unit must be installed in compliance and in accordance with all national, state, and local electrical and mechanical codes. Failure to do so will void all expressed or implied warranty representations. The PCO/UV N-Duct unit is designed for air disinfection and installs into the air handling system or ductwork. Select a mounting location that offers sufficient space for the mounting plate 7 x 13 and enough internal space for the UV lamps and PCO filter 11 H x 17 D. In addition, allow for sufficient space for removal (pulling out) of an 18 UV lamp. Installation also requires access to 120 277 VAC electrical power. Do not install where UV lamp is visible Do not install in outdoor applications Do not expose wiring or plastic to UV light Do not install beneath a humidifier If installed near an air filter, check with the filter manufacturer for UV properties & safety. 3

The unit should be installed perpendicular to the airflow so that air passes the UV lamps first. Airflow Airflow While the unit can be installed in either the return or supply air side, it may be more effective in removing airborne contaminants if installed on the supply side. Once a mounting location is selected, use the included Mounting Template to mark the location of the mounting plate screw holes and Lamps/PCO Filter insertion hole (center this hole in the duct if possible). Drill screw holes and cut insertion hole (make sure surfaces are flat and burr free). Install unit into duct securing with sheet metal screws. Open Display Panel door and insert UV lamps into UV lamp portals (swivel lamp retaining clamps out of the way then return when lamps are inserted). Attach white lamp socket to 4 pins on lamp base (the lamp socket is asymmetrical and can only be attached one way rotate socket so holes align with base pins). (If installing into ductboard, the unit can be secured with duct tape or by making 2 sheetmetal brackets 1 x 10 and securing the unit to the brackets with screws/nuts another work hole must be cut in the duct to allow access to attach the brackets to the mounting plate.) CONNECT POWER The PCO/UV N-Duct unit is a variable voltage device and is designed for use with 120 277 VAC. The unit can be plugged into any 110 VAC electrical outlet, or by cutting the plug off the powercord can be wired into any AC source so that the unit is ON continually; or wired directly into the HVAC control panel so that it operates when the HVAC system is running. CHECK UNIT OPERATION Once the unit is connected to an electrical power source it should be fully operational. The PCO/UV N-Duct unit has a kill switch activated by the Display Panel door. If the door is open, power to the electrical functions of the unit are shut off. The Display Panel door must be closed for the unit to operate. If the unit is receiving power and the Display Panel door is closed, the Power On LED should be lit as well as the 2 LEDs indicating the UV lamps are lit. 4

TROUBLESHOOTING 1) Power On light is not lit - Ensure the unit is receiving power (unit is wired correctly or plugged into an active AC outlet) - If wired into the HVAC control panel, HVAC unit must be running - Ensure Display Panel door is closed completely 2) UV Lamp On light is not lit - Check that the lamp socket is firmly attached to the lamp base pins - Ensure the wires to the lamp socket have not become dislodged - Ensure the UV lamp is operational (open the Display Panel door; pull the UV lamp out slightly so that the lamp glass can be seen; deactivate the kill switch by depressing the kill switch button; if UV lamp does not light, replace lamp UV resistant safety glasses should be worn for this test) WARNINGS WARNING Electrical Shock The PCO/UV N-Duct system is to be wired or plugged into 110 240 VAC electrical power. Ultraviolet Light is Harmful Never look at a lit ultraviolet lamp without UV protective glasses and skin coverings. Unplug the lamp before servicing. Ultraviolet Lamp May Cause Injury Ultraviolet lamps are made of glass and therefore somewhat fragile. Safety glasses and gloves should be worn when handling a UV lamp. In addition, UV lamps can be very hot and cause skin burns. Allow lamp to cool before handling. ULTRAVIOLET LAMP LIFE Like all light bulbs, UV lamps have a life span. Unlike regular light bulbs, however, UV lamps loose their effectiveness over time. Typically, after 9000 hours of use (approximately 1 yr.), the lamps do not produce enough ultraviolet germicidal irradiation to be effective. However, even after this time, the lamps usually do not burn out, but stay lit. This is often confusing to owners, but the lamps simply no longer produce the intensity necessary to be effective in improving or maintaining indoor air quality and must be replaced. It should also be noted that some ultraviolet lamps burn out prematurely and do not last the full 9000 guaranteed hours. AirGorilla s visual and audible reminders of when the UV lamps need to be replaced (or if they have burned out) help ensure you are receiving the full benefit and effectiveness of the PCO/UV N-Duct s advanced air cleaning technologies. 5

INSTALLING OR REPLACING THE ULTRAVIOLET LAMPS Steps for Replacing the Ultraviolet Lamps: 1. READ THE WARNINGS ABOVE. 2. If the unit is plugged into an AC outlet, simply unplug it before servicing the UV lamps. 3. Open the Display Panel door. The Display Panel door is connected to a kill switch that disables power inside the unit when the door is opened. 4. The unit contains 2 UV lamps. The base of the UV lamps (white in color) are visible on the left side of the enclosure. Attached to each lamp base is a white socket with wires leading to the power supplies that are housed to the right (separately enclosed). Pull the lamp socket off the UV lamp base. 5. Each lamp base is held in a cavity by two swivel clamps. Simply swivel them out of the way. Grab the lamp base and pull it toward you gently. The lamps are held snug so a little force may be necessary to pull them out. The lamps are 16 long. 6. Install new, replacement lamps (AirGorilla #DR36-1). a. Make sure lamp is clean use alcohol wipe to remove dirt and fingerprints. b. Insert UV lamp into UV lamp portal. c. Turn swivel clamps over lamp base to hold secure. d. Attach lamp socket (align holes in socket to lamp base pins). 7. Push the Reset button next to the lamp (there is a reset button for each lamp) that restarts the 9000 hour timer that alerts you when the lamp reaches the end of its effective life. 8. Close the Display Panel door. Plug in the power cord if applicable. Within a few seconds, the LED lights that indicate POWER ON and AIR PURIFYING should be lit (not the REPLACE LAMP LED). 9. If the correct LEDs are not lit, reopen the Display Panel door and make sure the lamp socket is attached fully to the lamp base pins, then make sure the Display Panel door is closed completely. If the LED lights are still not lit, consult the TROULESHOOTING SECTION ABOVE. 6

LIMITED LIFETIME WARRANTY AirGorilla Corporation warrants this unit to be free from defects in material and workmanship under normal use and service, for as long as it is owned by the original purchaser. This warranty does not cover expendable components with limited life such as the UV lamps (1 yr. warranty, prorated replacement cost) and ballasts (3 yr. warranty, prorated replacement cost). This warranty does not cover damage caused by handling, shipment, negligence, misuse, cosmetic damage, acts of God, connection to improper voltage, improper maintenance, or abuse. AirGorilla Corporation is not responsible for the installation of this product. This warranty does not cover faulty installation or damage to personal property resulting from incorrect or faulty installation. The warranty does not cover the cost of removal or reinstallation of the unit or the cost of return shipping to the manufacturer. AirGorilla Corporation s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any covered component that is found to be defective within the parameters defined herein. AirGorilla Corporation reserves the right to replace or repair the defective part or component. AirGorilla Corporation shall not be liable for any loss or damage of any kind, including any incidental or consequential damages resulting, directly or indirectly, from any breach of warranty, express or implied, or any other failure of this product. The manufacturer s maximum liability shall not exceed the actual purchase price paid for the product. The warranties set forth herein are exclusive and AirGorilla Corporation expressly disclaims all other warranties, whether written or oral, implied or statutory, including but not limited to any warranties of merchantability, workmanship, or fitness for a particular use. This warranty does not obligate AirGorilla Corporation for any labor costs and shall not apply to defects in workmanship or materials furnished by the installer. If you have a warranty claim, contact the company from which you purchased the product. Proof of original purchase and proof of identity as to being the original purchaser is required. Product or parts are not to be returned without factory issued Return Authorization number issued by AirGorilla Corporation.