FlexCharger Battery Chargers

Similar documents
Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

User s Manual. Automatic Switch-Mode Battery Charger

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

SBC / 2140 / Stage Battery Charger User Manual

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

8-STAGE AUTOMATIC BATTERY CHARGER MCU CONTROLLED - HIGH FREQUENCY SWITCHMODE MODELS: KACHG1207, KACHG1212, KACHG1220, KACHG2410. Instruction Manual

INTELLI-POWER BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE. P/No.s IC700, IC700W, IC1000, IC1500

O P E R A T I N G I N S T R U C T I O N S

Owner s Manual. Contents GP-PWM-10-SQ

QSSE, QSSEX INDUSTRIAL Battery Chargers

On-Board Battery Charger Kit

12V/25A BATTERY CHARGER MAINTAINER / JUMPSTARTER

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ

15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries

ST Charger. Industrial Battery Charger

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

LESTRONIC II BATTERY CHARGER MODEL 07210

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

EUROBAT EUROBAT GUIDE FOR MOTIVE POWER VRLA BATTERIES

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in

INTELLI-CHARGE BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE

GXSeries. User Guide DANGER

10 AMP ON BOARD BATTERY CHARGER

INTELLIGENT BATTERY CHARGER/MAINTAINER

INSTRUCTION MANUAL CAUTION

Sentry Battery Charger. Installation and Operations Manual Section 75

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

OBE, OBEXU, ON BOARD Battery Chargers

Installation and Operating Instructions (for chargers shown below)

OBAE, OBAEXU, ON BOARD Battery Chargers

Digital Mobile Charge Advanced Electronic In-Transit 4-Stage Battery to Battery Charger

BATTERY CHARGER OWNER S MANUAL POWER CHARGER Part # volt Amp

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

BatteryMINDer 1500* & BatteryMINDer Plus 1510*

SP6. Automatic Battery Charger. Model

Digital Intelligent Battery Charger OPERARATOR S MANUAL

2/10/50 AMP 12 VOLT BATTERY CHARGER/ ENGINE STARTER

BlueSolar charge controller MPPT 100/30

Marine Recreational Vehicle Batteries Made Simple

BC-1230P/ 1240P/ 1260P Multi-Stage Battery Chargers User Manual

BATTERY CHARGER Plus Battery maintainer & Rejuvenator

Models: SP3, SPSS3 Automatic Battery Charger

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

CBC-9130 / V 30A / 24V 15A Pro. Charger. Operation manual

BS20 BATTERY CHARGER For lead-acid batteries

Technical Note. Management of Sealed Lead Acid Batteries in Reliable Small DC Standby Power Supply Systems

Switch Mode, Automatic, Lead Acid Battery Charger Model: SEC A SEC A SEC A

Duo Battery Charge Controller

24 VOLT DUAL MODE WHEELCHAIR BATTERY CHARGER MODEL TYPE 24EL8 E&J PRODUCT NO

12 VOLT 30 AMP DIGITAL SOLAR CHARGE CONTROLLER

High Frequency SMT Golf Car Chargers Battery Tender Battery Charger Models: 12 Volt 20 Amp, 24 Volt 20 Amp, 36 Volt 15 Amp, 48 Volt 10 Amp

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

MPPT75HV MAXIMUM POWER POINT TRACKING SOLAR BATTERY CHARGE CONTROLLER

MODEL ELC-12/40-CVM-D BATTERY CHARGER

AC CONVERTER / BATTERY CHARGER

BATTERY CHARGERS FAN COOLED HIGH FREQUENCY CHARGERS UP 30% ENERGY SAVINGS! HIGH FREQUENCY BUILT-IN CHARGER AQHF24-30FC G2 TECHNICAL PECIFICATIONS

Microprocessor Controlled Multi-Stage 16V Automatic Battery Charger P/N User Guide

EASY CHARGE Waterproof portable Battery Charger

installation and operating instructions for the following xtreme Battery chargers:

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

Owner s Manual. Solar Controller GP-PWM-30

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

Installation and Operating Instructions (for chargers shown below)

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

12 VDC Power Sources For Your RV

SECTION DC POWER SUPPLY/BATTERY CHARGER

Car Battery Charger Instructions for Use

USER GUIDE 12 V Lead acid batteries Ah

Super PWRgate PG40S Spring City Drive Waukesha, WI

COLT CELL BATTERY CHARGER Installation and Operating Instructions

Eclipse Solar Suitcase

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Installation and Operating Instructions (for chargers shown below)

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer

Guardian Battery Charger Series. Installation and Operations Manual Section 75

12 Volt 1500 ma Convertible Charger - Maintainer - Desulfator*

A2P Single Phase Automatic Industrial Battery Charger

Turbo M Series onboard charger

Microprocessor Controlled Multi-Stage 12V/14V/16V Automatic Battery Charger P/N E. User Guide

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking.

Batteries and more. Powered by (CE, UL & ISO9001 APPROVAL)

Smart Charger SBC User s Manual

Part Number: DBDC10 / DBDC20 DC to DC Dual Battery Charger Manual

Caution Wear protective glasses and turn your face away when connecting or disconnecting from the battery.

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

OWNER S MANUAL. BatteryCharge FOR MODELS BC15 + BC25.

TECHNICAL BULLETIN Fig #1 - VRLA Battery Components. Intercell Welded Connection Strap joining neg. plates in parallel.

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

Powermaster IntelliCHARGER. Microprocessor Controlled Three-Stage 12V/16V Automatic Battery Charger P/N User Guide

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

MCC Automatic Start-Stop Microcomputer Charger Control

Instruction Manual. Automatic Battery Charger 12V 1000mA

IEEE IAS Atlanta Chapter

Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A

Transcription:

FlexCharger Battery Chargers Operating Instructions Definitions (as used in these instructions) Flooded Battery Lead-acid battery with liquid electrolyte that requires open-venting and regular water replacement. Sealed Battery Maintenance-free, lead-acid battery that uses an oxygen recombination technique to prevent water loss. VRLA (valve regulated lead-acid), Gel, AGM (absorption glass mat) or other technology. Sealed batteries do not require water replacement. 80% Charge Point Point during charge when the battery reaches 80% of full charge. 80% Charge Point Voltage Specific "on-charge" battery voltage the charger uses to determine when the battery is 80% charged. Initial Charge Charge up to the 80% charge point where cell voltage is 2.37 to 2.40 volts. Flooded batteries begin to emit gas (hydrogen & oxygen) after reaching the 80% charge point. Upon reaching the 80% charge point, sealed batteries are kept at a constant cell voltage to reduce or eliminate gassing. Finishing Charge Charge after Initial Charge up to the time the battery is fully charged. Equalize Charge An extended Finish Charge given periodically (once a week or every 5 to 7 charges) to ensure that each cell of the battery is fully charged. Flooded batteries only. Float Charge Low current charge that maintains the battery at full charge. It supplies enough current to replace amperes lost through internal discharge, but not enough to overcharge the battery. Batteries can be left on float charge indefinitely until needed. Soft Start When the charger is activated the current builds slowly, reducing shock and noise on the ac lines. Temperature Compensation Processor adjusts the charge profile according to the ambient temperature. For high temperatures,

the 80% charge point voltage is lowered, charge time shortened. For low temperatures, the 80% charge point voltage is raised, charge time lengthened. Interlock Optional feature of On-Board chargers. Allows lift operation using power from the charger, but prevents vehicle movement while the charger is connected to an ac source. Charger Overview Ferroresonant Chargers Traditional lead-acid battery chargers that use ferroresonant transformers. The transformer, itself, provides current limiting and voltage regulation during charge. These chargers work well with flooded batteries, but overcharge and damage more delicate modern sealed batteries. Do not use ferroresonant chargers on sealed batteries. SCR Chargers Chargers that use SCR (silicon controlled rectifiers) in conjunction with transformers. The output current and voltage are closely controlled by signals sent from the microprocessor to the SCRs. This close control suppresses gassing and prevents damage to sealed batteries, while still adequately charging flooded batteries. SCR chargers may or may not have several charge profiles for different manufacturer s batteries. FlexCharger Arrgh's standard SCR charger uses a single charge profile to safely and fully charging both sealed and flooded commercial batteries. When the Finish Charge ends, FlexCharger switches to Float Charge to maintain the battery at full charge and equalize the battery cells. For special needs, customized charge profiles are available through simple software changes. FlexCharger comes in two configurations -- "Portable" with handle and rubber feet, or "On- Board" with optional interlock and provision for a mounting bracket. Safety Do Ensure charger output voltage is the same as the battery voltage. Ensure battery and charger cables and connectors are intact, tight and clean. Charge in a ventilated area. Clean and dry the battery if wet or dirty. If flooded battery, check electrolyte level and add water before charge. Do not overfill. Use gloves and glasses when adding water. If on-board charger, disconnect from ac before using vehicle. Do Not Charge in the rain or allow water to get into the charger. Stand in water while connecting the battery to the charger. Leave flooded battery vent plugs off during charge. Smoke or cause sparks near batteries on or after charge.

Use charger for purposes other than to charge lead-acid batteries. Block the charger vent grill. Use charger near flammable materials or vapors. Move charger by pulling on charger cables. Open or attempt to repair the charger no serviceable parts inside. Operation 1. Connect the charger to a 110 or 220 volt, 15 amp, 50/60 hz, ac supply. FlexCharger will automatically adjust to either voltage and frequency. The charger will remain off until a battery is connected. 2. Connect the battery to the charger. 3. Charger will run an internal self-check and read the battery voltage. All 3 LEDs will flash in sequence one time -- Red/Yellow/Green. The numeric display will briefly show the ampere output rating of the charger. 4. If the charger will not turn on -- Red "Initial Charge" and Yellow "Finishing Charge" LEDs will alternate on and off. Problem is: A. Battery/charger mismatch -- battery voltage higher than the charger rating. (If the battery voltage is lower than the charger rating, the charger will charge the battery for 9 hours, then turn off because it was unable to reach the charger 80% charge point voltage within the 9 hour time limit). B. Short circuit. C. Battery voltage too low to power the processor and/or close the relay (8 volts dc +/- for 12 volt dc chargers; 16-20 volts dc for 24 volt dc or higher chargers). D. Charger malfunction. 5. If the charger does turn on, it will use a 10-15 second "soft start" -- charger fan speed will slowly increase to full speed and the ammeter needle will rise to the appropriate output reading. A. if the battery is below the 80% charge point voltage: 1. The Red "Initial Charge" LED will light and the charger will supply the maximum current the battery will accept up to the charger output rating. 2. Charger will charge the battery for a maximum of 9 hours or until the battery reaches the 80% charge point voltage. a. If the battery does not reach the 80% charge point voltage within 9 hours, the charger will turn off and the Red and Yellow LEDs will alternate on and off.

b. If the battery does reach the 80% charge point voltage within 9 hours, the charger will switch to "Finishing Charge", the Yellow LED will light and the charger output voltage will be held at 2.37 volts per cell. "Finishing Charge" time is based on the charge profile up to the 80% charge point, with a minimum of 1 hour and a maximum of 6 hours. c. At the end of the "Finishing Charge," the charger will switch to "Charge Complete" and the Green LED will light. If the battery is left connected to the charger, the charger will "Float Charge" the battery at 2.20 volts per cell and the Green LED will remain lit. d. When the battery is disconnected during or after charge, the charger and all LEDs will turn off. B. If the battery is above the 80% charge point voltage: 1. Charger will go to "Finishing Charge" for 20 minutes, the Yellow LED will light and the output voltage will be held at 2.37 volts per cell. 2. After 20 minutes, the charger will switch to "Charge Complete" and the Green LED will light. If the battery is left connected to the charger, the charger will "Float Charge" the battery at 2.20 volts per cell and the Green LED will remain lit. 6. Any time the battery is disconnected from the charger or the charger is disconnected from the ac power, the charger program is reset. 7. There is no ON /OFF switch. The charger turns on automatically when a battery and ac are connected, and turns off when the battery or ac is disconnected. 8. The numeric display normally shows the charging current. 9. If the charger is connected to the battery but not to an ac supply, the numeric display will briefly blink "ac" as a reminder it has no ac power. 10. If the charger is disconnected from the ac supply during charge, the numeric display will briefly show the software version installed. This is for factory use. 11. The label on the back of the charger lists the charger model, ac input, dc output, and serial number. 12. There are no user serviceable parts in the charger. If the charger does not function correctly, contact your dealer or the factory.

LEDs Red / Yellow / Green Flash in sequence one time -- battery & ac power connected, charger initiating internal self-check. Red Initial Charge Yellow Finishing Charge Green Charge Complete and Float Charge. Red / Yellow Alternating on & off -- indicate a Fault: Battery/charger mismatch Short circuit Battery did not reach 80% charge within 9 hours Charger malfunction