Level Measurement Level Sensors with Reed Switch Chain Technology Model RMG Applications Level measurement for almost all liquid media Chemical industry, petrochemical industry, natural gas, ting equipment, power stations Process water and drinking water treatment, food and Special Features Operating limits: - Operating temperature: T = -80... +200 C - Limit S. G.: 3 connections and materials, Explosion-protected versions Description serve as measuring transducers for level measurement in transmission. potentiometer circuit. The measurement voltage generated the contact separation of the measuring chain and is thus virtually continuous. Depending on the requirements, contact separations from Level Sensors with Reed Switch Chain Technology, Model RMG, Connection Page 1 of 10 Data sheets showing similar products: Level Sensors, magnetostrictive measuring principle; Model FFG; see Data Sheet LM 20.01
Further special features Large scope of application due to the simple, proven functional principle For harsh operating conditions, long service life Continuous measurement of the liquid levels irrespective of physical or chemical changes of state of the measured media, such as: foaming, conductivity, dielectric constant, pressure, vacuum, temperature, Signal transmission over large distances - Volume-proportional or depth-proportional of the 3 Level sensors with reed switch chain technology qualify Options - on request) the limit values over the entire measuring range Product prograe Selection of process connection, material and design further information on the indicated pages. Process connection Material Explosion-protected Material Stainless steel version PVC / PP / PVDF - Page 5 Page 5 Page 2 of 10
Application examples Standard applications Connection to bus systems PLC or Power supply Control room PLC or Option: head-mounted or gate Option: head-mounted Product layer Applications for Ex-Zone 0 Applications for Ex-Zone 1, 2 PLC or PLC or not intrinsically safe not intrinsically safe PLC or PLC or not Ex Ex* Sensor Option: head-mounted not Ex Ex* not intrinsically safe from metal or anti-static plastic Option: head-mounted vessel *only for Ex- Measuring accuracy 10.0 % 1.0 % 0.1 % Measuring range in Legend Page 3 of 10
Standard version Connection M20x1.5 M20 x 1.5 SW 22 or SW 30 or Mounting (without terminal box) Electrical connection PVC grey Silicone Process connection upwards request) on request) downwards Option: Polypropylene, polyester, stainless steel 18 18 18 max. Float Max. working pressure 3000 3000 3000 Temperature range standard -20... +120 C Option: Option: Low temperature version: -80... -20 C Contact separation Overall resistance of the measuring chain Mounting position Vertical ± 30 Length and separation dependent
Explosion-protected version, intrinsically safe M20 x 1.5 M20 x 1.5 X SW 30 or Process temperature X 0 < 100 C Electrical connection Option: Polyester, stainless steel Process connection Float Max. working pressure downwards Temperature class Surface temperature Process temperature Max. 135 C 100 C 85 C Contact separation Overall resistance of the measuring chain Control circuit mitter Mounting position Vertical ± 30 Length and separation dependent Page 5 of 10
Plastic version Connection M20x1.5 M20 x 1.5 or SW 32 Mounting (without terminal box) Electrical connection PVC grey Silicone Process connection max., upwards on request), downwards Float Material PVC Polypropylene PVDF Max. working pressure Temperature range Polypropylene -10... +80 C PVDF -10... +100 C Contact separation Overall resistance of the measuring chain Mounting position Vertical ± 30 Length and separation dependent
Stainless steel version, E-CTFE coated M20 x 1.5 (Guide tube diameter 12 ) (Guide tube diameter 18 ) Electrical connection Option: Polypropylene, polyester, stainless steel Process connection 12 18 max. Float Max. working pressure Temperature range 2000 Depending on medium Contact separation Overall resistance of the measuring chain Mounting position Vertical ± 30 Length and separation dependent Option Coating electrically conductive
Ø C D E D = Limit S. G. of the medium, volume 85 % Material Suits guide tube Ø Ø A B Ø C Max. working pressure bar Max. operating temperature C Limit S. G. 85 % kg/m 3 Nominal S. G. 50 % kg/m 3 12 52 52 15 250 12 15 32 250 1015 12 83 81 15 25 250 18 80 23 25 250 18 23 25 250 18 105 103 23 25 250 520 18 120 23 25 250 18-30 120 38 25 250 12 52 52 15 25 250 12 52 52 15 250 12 52 52 15 80 250 12 15 25 250 820 12 83 81 15 25 250 583 18 80 23 25 250 18 23 25 250 18 105 103 23 25 250 18 120 23 25 250 315 535 18 81 22 25 depending on medium E-CTFE coated 18 22 25 depending on medium 1111 18 22 25 depending on medium 1011 18 121 118 22 3 depending on medium Page 8 of 10
Ø C D E D = Limit S. G. of the medium, volume 85 % Material Suits guide tube Ø Ø A B Ø C Max. working pressure bar Max. working temperature C Limit S. G. 85 % kg/m 3 Nominal S. G. 50 % kg/m 3 12 52 15 250 1258 12 52 15 250 PVC 16 55 22 3 805 20 55 80 3 20 80 25 3 Polypropylene 16 55 22 3 80 20 55 80 3 80 20 80 25 3 80 PVDF 16 55 22 3 100 20 55 80 3 100 20 80 25 3 100 1200
Determination of the max. guide tube length L for explosion-protected versions, intrinsically safe Version A: Fixed to the tank ceiling Version B: Fixed to the tank ceiling Illustration with the required dimensions for ordering L1... L... L... L... M... 0 % Guide tube Max. guide tube length L Version A Version B Ø 12 x 1 3500 5000 Ø 18 x 2 3000 Legend ) length of the sensor On ordering, the dimension L1 and the Ordering information Page 10 of 10 E-mail info@wika.de www.wika.de