User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

Similar documents
User s Manual Power Supply IM E. 5th Edition

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Hybex Microsample Incubator

Mini Multimeter with Non-Contact Voltage Detector (NCV)

System 3 ZB1PS Device Chassis. Operator s Manual

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition

CENTERING DEVICE. Model CE-1 OPERATOR S MANUAL

DC POWER SUPPLY ALIMENTATION C.C.

OPERATING INSTRUCTIONS

PY-11 Voltage & Continuity Tester

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

Autoranging Multimeter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Autoranging Industrial Multimeter

True RMS Autoranging Multimeter

Fiber Optic Illuminator. Model 21AC Model 21DC

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

USER S MANUAL TUBE SEALER. Model SE450. No. CAT.SE45010Ce

Register your instrument! HeatSealer S100. Operating manual

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

ION JET NOZZLE NIH-55

innovations in battery charging

362 Clamp Meter. Users Manual

58kHz AM Deactivator DB104 Instruction Manual V1.0

323/324/325 Clamp Meter

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Triple Output Power Supply

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

Mini Multimeter with Non-Contact Voltage Detector (NCV)

302+/303 Clamp Meter. Users Manual

362 Clamp Meter. Users Manual

Declaration of Conformity

EPM1510SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

i3000s/i2000 Flex AC Current Probe

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

FD Conveyor for FD 260 Tabber

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Lumitester PD-20 Control Kit


Safety design conforming to the following provisions

82V LITHIUM-ION BATTERY CHARGER GC 400

Go to to register your product and find more information.

Triple Output High Resolution Power Supply. User Manual

Models: EP EP EP EP EP EP USER MANUAL ENGLISH

Model 1672, 1673 Triple Output Power Supply

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

365 Detachable Jaw True-rms Clamp Meter

Installation Guide Thermal Conductivity Detector Accessory 19232E

Operation Manual for the Drummond Pipet-Aid XP

Sublite V INSTRUCTIONS FOR USE. 1. Safety information. Light curing sub-unit for dental laboratory INTRODUCTION WARNING AND CAUTION

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

OPERATION and MAINTENANCE INSTRUCTION MANUAL

Users Manual. Phase Rotation Indicator

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

i400s Calibration Information Introduction

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

Digital/Analog Megohmmeter Model 1026

Installation Guide NPD/ECD Chemical Filters Accessory 19199N

SZ2-ILA INSTRUCTIONS TRANSMITTED ILLUMINATION ATTACHMENT SZ-ADD SZ-POL-2 SZH-CLJ. Optional Modules

Operation Manual for the Drummond Pipet-Aid XL

LED Twister II. User manual UK Version 1.0

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

Lumitester PD-30. Instruction Manual. Table of Contents

LANCER EVOLUTION (2008 ) MUD FLAP MZ531356EX (Black with aluminum plate) MZ531357EX (Black standard) INSTALLATION AND HANDLING INSTRUCTIONS

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

ASSEMBLED BY HAND IN THE USA

USER S MANUAL TUBE SEALER. Model SE250. No. CAT.SE25010Ce

OPERATING INSTRUCTIONS

RECHARGEABLE POWER OUTAGE LED LIGHT INSTRUCTION MANUAL

WARNING WARNING WARNING. English Quick start guide CAUTION CAUTION. Installation Precautions

Visit us at

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

GENUINE REAR SPOILER

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

FlexChem Model 404 Rotating Oven

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Model 700 Microarray Oven

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

Remote Control Engine Starter System Owner s Manual

Transcription:

User s Manual 700938 Power Supply Yokogawa Electric Corporation 3rd Edition

Introduction Revisions Thank you for purchasing the 700938 Power Supply. This Instruction Manual contains useful information about the instrument s functions and operating procedures as well as precautions that should be observed during use. To ensure proper use of the instrument, please read this manual thoroughly before operating it. Keep the manual in a safe place for quick reference whenever a question arises. 1st Edition : May 1999 2nd Edition : January 2001 3rd Edition : November 2005 Disk No. OE12 3rd Edition : November 2005 (YK) All Rights Reserved, Copyright 1999 Yokogawa Electric Corporation 1

The following symbol marks are used to attract the operator s attention. Affixed to the instrument, indicating that for safety, the operator should refer to the User s Manual. WARNING CAUTION Describes precautions that should be observed to prevent the danger of injury or death to the user. Describes precautions that should be observed to prevent damage to the instrument. Note Provides information that is important for proper operation of the instrument. Checking the Contents of the Package If the worng instrument or accessories have been delivered, if some accessories are missing or if they appear abnormal, contact the dealer form which you purchased them. 700937 Current Probe Main Body Standard Accessorries Instruction manual 1 Power cord 1 Spare fuse (in the fuse holder) 1 V, 120 V : F1.0 AL/250 V, 20 mm 5 mm dia. 220 V, 240 V : F0.5 AL/250 V, 20 mm 5 mm dia. 2 IM700938-01E

Safety Precautions This instrument is an IEC safety class I instrument (provided with terminal for protective grounding). The following general safety precautions must be observed during all phases of operation, service and repair of this instrument. If this instrument is used in a manner not specified in this manual, the protection provided by this instrument may be impaired. Also, YOKOGAWA Electric Corporation assumes no liability for the customer's failure to comply with these requirements. The following symbols are used on this instrument. To avoid injury, death of personnel or damage to the instrument, the operator must refer to an explanation in the User's Manual or Service Manual. Functional grounding terminal (This terminal should not be used as a Protective grounding terminal.) Alternating current ON (power) OFF (power) 3

Precautions In order to ensure safe operation and to obtain maximum performance from the unit, observe the cautions listed below. WARNING This unit is designed to be grounded through the three-wire power cord provided. In order to prevent electric shock, etc., connect this power cord to a grounded three-prong power receptacle. CAUTION Do not subject the unit to vibrations or shocks during transport or handling. Be especially careful to avoid dropping the unit. Do not store the unit where it will be exposed to direct sunlight, high temperature, high humidity, or condensation. If exposed to such conditions, the unit may be damaged, the insulation may deteriorate, and the unit may no longer satisfy its specifications. Before using the unit, inspect it and check the operation to make sure that the unit was not damaged due to poor storage or transport conditions. If damage is found, contact your dealer or YOKOGAWA representative. When unplugging the power cord from the power receptacle or from the unit, grasp the plug, not the cord, in order to avoid damaging cable. This unit is not constructed to be waterproof or dustproof, so do not use it in a very dusty environment or in one where it will get wet. Gently wipe dirt from the surface of the unit with a soft cloth moistened with a small amount of water or mild detergent. Do not try to clean the unit using cleaners containing organic solvents such as benzine, alcohol, acetone, ether, ketones, thinners, or gasoline. They may cause discoloration or damage. 4 IM700938-01E

Contents Introduction... 1 Checking the Contents of the Package... 2 Safety Precautions... 3 Precautions... 4 Product Overview... 6 Names of Parts External view... 6 Measurement Procedure Preparations... 6 Measurement Procedure... 6 Description of Parts Power Supply Receptacle... 8 Fuse Replacement... 8 When Switching the Current Voltage... 9 When Replacing the Power Fuse... 9 Specifications Product Specifications... 10 Standards Applying... 10 Corrective Action to be Taken in the case of an Abnormality... 10 5

Product Overview This unit is a special-purpose power supply for the Probe. Two power supply receptacles are provided on the front panel, and this allows two probes to be used simultaneously. Names of Parts External view Power indicator Power supply connector Fuse holder POWER SUPPLY POWER Voltage viewing window ON PROBE 1 2 OFF Power switch Power supply receptacles MODEL NO. Made in Japan Grounding terminal Front view Rear view Measurement Procedure Preparations CAUTION Before turning on the power, make sure that the voltage of the power supply being used matches the supply voltage indicated on the rear panel of the unit. 1 Turn the power switch off and connect the power cord. 2 Insert the power supply plug for the DL Series wide band current probe that you are using into the power receptacle on this instrument. 3 Turn the power switch ON, and check that the front panel power indicator lights. Measurement Procedure See the 700937, 701930, 701931, 701932, or 701933 instructionmanual. Note When using the Current Prove (Model 701930, 701931, 701932 or 701933) together with this power supply, you may not be able to use a second current probe simultaneously depending on the value of the curernt being measured. The current consumption of the probe is dependent upon the value of the current being measured. Do not let the total current consumption of the probe exceed the rated output current of the 700938. See figure 1. 6 IM700938-01E

Current consumption (ma) Current consumption (ma) Current consumption (ma) Current consumption (ma) Current consumption (ma) 200 150 50 0-15 -10-5 5 10 15-50 - -150-200 Value of the current being measured (A) 700937 700 600 500 400 300 200 0-300 -200 - - 0 200 300-200 -300-400 -500-600 -700 Value of the current being measured (A) 701930 600 500 400 300 200 0-700-600-500-400-300-200-0 200 300 400 500 600 700-200 -300-400 -500-600 Value of the current being measured (A) 701931 600 500 400 300 200 0 0 - -200-300 -400-500 -600 Value of the current being measured (A) 701932 600 500 400 300 200 0-700-600-500 -400-300-200 0 200 300 400 500 600 700 - -200-300 -400-500 -600 Value of the current being measured (A) 701933 Figure 1 Current consumption* vs. current to be measured (typical) *Total of positive and negative power DC AC(f=50Hz) Positive current Negative current DC AC(f=50Hz) Positive current Negative current DC AC(f=50Hz) Positive current Negative current DC AC(f=50Hz) Positive current Negative current DC AC(f=50Hz) Positive current Negative current 7

Description of Parts Power Supply Receptacle The pin assignment of the receptacle is shown in the following. 4 1 3 2 1 Not used 2 +12V 3-12 V 4 GND Fuse Replacement If the fuse blows, replace it as shown in Figure. WARNING In order to prevent electric shock, always disconnect the power cord from the receptacle before replacing the fuse. Always replace the fuse with a new fuse of the specified rating. Never use a fuse of other than the specified rating, and never short circuit the fuse holder to prevent an accident resulting in injury or death. V, 120 V : F1.0 AL/250 V 20 mm x 5 mm dia. 220 V, 240 V : F0.5 AL/250 V 20 mm x 5 mm dia. 1 Turn OFF the power switch and unplug the power cord. 2 Insert a tool such as a flathead screwdriver into the fuse holder notch in the power supply inlet, and use it to pry out the fuse holder. 3 When Replacing the Power Fuse Replace the power fuse with another fuse of the specified rating. When Switching the Current Voltage (1) Remove the voltage selector box from the fuse holder, rotate the box so that the desired voltage can be seen through the viewing window, then reinsert it into the fuse holder. Confirm that the desired voltage setting appears in the viewing window. (The display will be upside down.) (2) Replace the power fuse with another fuse of the specified rating. 4 Reinsert the fuse holder into the power inlet. AC Inlet Screwdriver Use a tool such as a flathead screwdriver to pry out the fuse holder. Fuse holder 8 IM700938-01E

When Switching the Current Voltage Voltage selector box Fuse holder Viewing window 220 240 120 Remove the voltage selector box, rotate it so that the numbers visible through the viewing window match the line voltage that you are using, then reinsert the box into the fuse holder. When Replacing the Power Fuse Fuse 9

Specifications Product Specifications Compatible sensors 700937 Current Probe 700939 FET Probe 701920 Differencial Probe 701930 Current Probe 701931 Current Probe 701932 Current Probe 701933 Current Probe Number of power supply connectors 2 Output voltage ±12 V ±0.5 V Operating temperature and humidity range 0 to 40 C (32 to 104 F), 80% RH or less (no condensation) Storage temperature and humidity range -10 to 50 C (14 to 122 F), 80% RH or less (no condensation) Location for use Indoor, altitude up to 2000m (6562 feet) Rated output current Rated supply voltage Ripple supply voltage Rated supply frequency Maximum rated power External dimensions Mass Accessories 600 ma (the total value of both outputs) V AC (120, 220, and 240 V requires specification) (Voltage fluctuation of 10% from the rated supply voltage are taken into account.) 3 mvp-p (at the rated output current) 50/60 Hz 60 VA (at the rated output current) Approx. 73(W) 110(H) 186(D) mm Approx. 2.87"(W) 4.33"(H) 7.32"(D) Approx. 1.1 kg Approx. 38.8 oz. Power cord, Instruction manual, Spare fuse (in the fuse holder) V, 120 V : F1.0 AL/250 V, 20 mm 5 mm dia. 220 V, 240 V : F0.5 AL/250 V, 20 mm 5 mm dia. Standards Applying Safety EMC EN61010-1 Pollution Degree 2 EN61326 EN60-3-2 EN60-3-3 Corrective Action to be Taken in the case of an Abnormality If an message appears on the screen, refer to the following pages. If maintenance service is required, or if the instrument still does not operate properly even if the proper corrective action has been taken, contact your nearest YOKOGAWA representatives, listed on the back cover of this manual. Symptom Possible Cause Corrective Action The power cannot be turned ON. The fuse is blown. Replace the fuse. 10 IM700938-01E