Voltage 220 to or 1800 RPM

Similar documents
220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

3412C Generator Set Electric Power. Specifications. Benefits and Features

220 to volts. Electronic unit injection

Specifications. 3406C Generator Set Electric Power

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Continuous, Prime, Standby, Mission Critical

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

400 to 11,000 Volts. Standby, Prime, Continuous

Voltage 220 to or 1800 RPM. Engine Specifications C32 TA, V-12, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in)

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

Specifications. C13 Generator Set Electric Power

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

including r installations. Backed by the worldwide l provide the reliabi Prime LEHE1073

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

Generator Set Specifications 100 ekw (125 kva)

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

like mission critical Backed by the worldwide l provide the reliabi Mission Critical LEHE1075

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENERATOR SET FEATURES

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

PRIME 225 ekw 281 kva

Generator Set Specifications 60 ekw (75 kva)

Aftercooler (Separate Circuit) N/A N/A

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 400 ekw 500 kva

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel. Compression Ratio 15.0:1 Turbocharged Aftercooled.

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

Cat C32 Diesel Generator Sets

C32 ACERT Generator Set Electric Power

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Cat C32 Diesel Generator Sets

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

DIESEL FEATURES GENERATOR SET

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

Cat 3516B Diesel Generator Sets

Generator Set Specifications Rating (ekw) Rating (kva) Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel

Enclosures. Options Caterpillar yellow or white paint Integral dual wall fuel tank base for total fluid containment (fuel, oil and coolant)

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

Bore mm 4.0 in Displacement 5.7 L 350 in³ Stroke 88.4 mm 3.48 in Compression Ratio 9.4:1

Cat C32 Diesel Generator Sets

Cat C Diesel Generator Sets

ESP 550 ekw 688 kva 60 Hz 1800 rpm 480 Volts

Cat 3516C Diesel Generator Sets

Cat 3412 Diesel Generator Sets

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

Cat C Diesel Generator Sets

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Cat 3512 Diesel Generator Sets

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Hydraulic electronic unit injection

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

3516B Generator Set Electric Power

Cat 3512 Diesel Generator Sets

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

Generator Set Specifications 480 ekw 600 KVA

Cat 3512B Diesel Generator Sets

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

Cat 3516B Diesel Generator Sets

Generator Set Specifications 320 ekw (400 kva)

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Transcription:

A TA Diesel Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications Generator Set Specifications Minimum Rating 1450 ekw (1600 kva) Maximum Rating 1750 ekw (2000 kva) Voltage 220 to 13800 Frequency 50 or 60 Hz Speed 1500 or 1800 RPM Generator Set Configurations Emissions/Fuel Strategy Low Fuel Consumption Engine Specifications Engine Model TA, V-16, 4-Stroke Water-Cooled Diesel Bore 170 mm 6.69 in Displacement 69 L 4210.64 in³ Stroke 190 mm 7.48 in Compression Ratio 13.0:1 Aspiration TA Governor Type Woodward Fuel System Mechanical unit injection SS-7355356-18316873-000 SS Page 1 of 7 Page: M-1 of M-4

A TA Diesel Generator Set Benefits And Features Cat Diesel Engine Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight Generator Matched to the performance and output characteristics of Cat engines Industry leading mechanical and electrical design Industry leading motor starting capabilities High Efficiency Cat EMCP Control Panel The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules. Design Criteria The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response. UL 2200 / CSA - Optional UL 2200 listed packages CSA Certified Certain restrictions may apply. Consult with your Cat Dealer. Single-Source Supplier Fully prototype tested with certified torsional vibration analysis available World Wide Product Support Cat Dealers provide extensive post sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Cat SOSSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products. SS-7355356-18316873-000 SS Page 2 of 7 Page: M-2 of M-4

A TA Diesel Generator Set Standard Equipment Air Inlet Air Cleaner Cooling Package mounted radiator Exhaust Exhaust flange outlet Fuel Primary fuel filter with integral water separator Secondary fuel filter Fuel priming pump Generator Matched to the performance and output characteristics of Cat engines IP23 Protection Power Termination Bus Bar Control Panel EMCP 4 Genset Controller General Paint - Caterpillar Yellow except rails and radiators gloss black Optional Equipment Exhaust Exhaust mufflers Generator Anti-condensation heater Internal excitation (IE) Permanent magnet excitation (PMG) Oversize and premium generators SS-7355356-18316873-000 SS Page 3 of 7 Page: M-3 of M-4

A TA Diesel Generator Set Power Termination Circuit breakers, UL listed Circuit breakers, IEC compliant Control Panels EMCP 4.2 EMCP 4.3 EMCP 4.4 Generator temperature monitoring & protection Load share module Digital I/O module Remote monitoring software Mounting Rubber anti-vibration mounts Spring-type vibration isolator IBC isolators Starting/Charging Battery chargers Oversize batteries Jacket water heater Heavy-duty starting system Charging alternator Air starting motor with control and silencer General The following options are based on regional and product configuration: Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007 UL 2200 package EU Certificate of Conformance (CE) CSA Certification EEC Declaration of Conformity Enclosures: sound attenuated, weather protective Automatic transfer switches (ATS) Integral & sub-base fuel tanks Integral & sub-base UL listed dual wall fuel tanks The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, ADEM, EUI, S O S, "Caterpillar Yellow" and the "Power Edge" trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. SS-7355356-18316873-000 SS Page 4 of 7 Page: M-4 of M-4

ELECTRIC POWER - Technical Spec Sheet STANDARD 1280 ekw/ 1600 kva/ 50 Hz/ 1500 rpm/ 400 V/ 0.8 Power Factor Rating Type: CONTINUOUS Fuel Strategy: LOW FUEL CONSUMPTION 1280 ekw/ 1600 kva 50 Hz/ 1500 rpm/ 400 V Image shown may not reflect actual configuration Metric English Package Performance Genset Power Rating with Fan @ 0.8 Power Factor 1280 ekw Genset Power Rating 1600 kva Aftercooler (Separate Circuit) 82.0 C 179.6 F Fuel Consumption 100% Load with Fan 337.2 L/hr 89.1 gal/hr 75% Load with Fan 260.4 L/hr 68.8 gal/hr 50% Load with Fan 188.3 L/hr 49.7 gal/hr 25% Load with Fan 112.6 L/hr 29.7 gal/hr Cooling System¹ Engine Coolant Capacity 233.0 L 61.6 gal Inlet Air Combustion Air Inlet Flow Rate 107.1 m³/min 3781.9 cfm Max. Allowable Combustion Air Inlet Temp 96 C 205 F Exhaust System Exhaust Stack Gas Temperature 478.2 C 892.8 F Exhaust Gas Flow Rate 272.3 m³/min 9616.3 cfm Exhaust System Backpressure (Maximum Allowable) 6.7 kpa 27.0 in. water SS-7355356-18316873-000 SS Page 5 of 7 TSS-DM8368-04-GS-EPG-7355356.pdf Page 1 of 3

ELECTRIC POWER - Technical Spec Sheet STANDARD 1280 ekw/ 1600 kva/ 50 Hz/ 1500 rpm/ 400 V/ 0.8 Power Factor Rating Type: CONTINUOUS Fuel Strategy: LOW FUEL CONSUMPTION Heat Rejection Heat Rejection to Jacket Water 832 kw 47319 Btu/min Heat Rejection to Exhaust (Total) 1222 kw 69503 Btu/min Heat Rejection to Aftercooler 136 kw 7750 Btu/min Heat Rejection to Atmosphere from Engine 146 kw 8285 Btu/min Heat Rejection to Atmosphere from Generator 69 kw 3913 Btu/min Alternator² Motor Starting Capability @ 30% Voltage Dip 4723 skva Current 2309 amps Frame Size 1645 Excitation PM Temperature Rise 105 C Emissions (Nominal)³ NOx 8115.8 mg/nm³ 15.2 g/hp-hr CO 354.8 mg/nm³ 0.7 g/hp-hr HC 74.6 mg/nm³ 0.2 g/hp-hr PM N/A N/A DEFINITIONS AND CONDITIONS 1. For ambient and altitude capabilities consult your Cat dealer. Air flow restriction (system) is added to existing restriction from factory. 2. UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics. Generator temperature rise is based on a 40 C ambient per NEMA MG1-32. 3. Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D & E and ISO8178-1 for measuring HC, CO, PM, NOx. Data shown is based on steady state operating conditions of 77 F, 28.42 in HG and number 2 diesel fuel with 35 API and LHV of 18,390 btu/lb. The nominal emissions data shown is subject to instrumentation, measurement, facility and engine to engine variations. Emissions data is based on 100% load and thus cannot be used to compare to EPA regulations which use values based on a weighted cycle. SS-7355356-18316873-000 SS Page 6 of 7 TSS-DM8368-04-GS-EPG-7355356.pdf Page 2 of 3

ELECTRIC POWER - Technical Spec Sheet STANDARD 1280 ekw/ 1600 kva/ 50 Hz/ 1500 rpm/ 400 V/ 0.8 Power Factor Rating Type: CONTINUOUS Fuel Strategy: LOW FUEL CONSUMPTION Applicable Codes and Standards: AS1359, CSA C22.2 No100-04, UL142,UL489, UL869, UL2200, NFPA37, NFPA70, NFPA99, NFPA110, IBC, IEC60034-1, ISO3046, ISO8528, NEMA MG1-22,NEMA MG1-33, 72/23/EEC, 98/37/EC, 2004/108/EC Note: Codes may not be available in all model configurations. Please consult your local Cat Dealer representative for availability. CONTINUOUS:Output available with non-varying load for an unlimited time. Average power output is 70-100% of the continuous power rating. Typical peak demand is 100% of continuous rated ekw for 100% of operating hours. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions Fuel Rates are based on fuel oil of 35º API [16º C (60º F)] gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C (85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional ratings may be available for specific customer requirements, contact your Cat representative for details. For information regarding Low Sulfur fuel and Biodiesel capability, please consult your Cat dealer. www.cat-electricpower.com Performance No.: DM8368-04 Feature Code: 516DE89 Generator Arrangement: 2523936 Date: 02/25/2015 Source Country: The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, ADEM, EUI, S O S, "Caterpillar Yellow" and the "Power Edge" trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. SS-7355356-18316873-000 SS Page 7 of 7 TSS-DM8368-04-GS-EPG-7355356.pdf Page 3 of 3