Xtender o Software vers. : and higher. RCC-02/-03 o Software vers. : and higher o RCC User level : EXPERT

Similar documents
Optimal solar backup. Application Note 002. General description. Minimal configuration. Features & advantages. Application Schematic

Anti-blackout system for grid connected solar installations (Solsafe concept)

Engineered power. Inverter-chargers. Inverters. MPPT solar charge controllers. Battery chargers. Battery monitoring.

Off-Grid solutions. solutions for rural electrification. swiss made power

Battery Status Processor BSP

Battery Status Processor BSP

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

User Manual. Remote control and programming unit. RCC-02 and RCC-03 for the Xtender

Remote control and programming unit RCC-02 and RCC-03 for the Xtender User manual

Solar inverter AX-series

Configuration Diagrams

Engineered power. Inverter-chargers. Inverters. MPPT solar charge controllers. Catalogue. Battery chargers. Battery monitoring.

Energy for a better life

Mini-Grids with Distributed Energy Generation and Frequency Control

HYBRID POWER FOR TELECOM SITES

Remote control and programming unit RCC-02 and RCC-03 for the Xtender User manual

Engineered power. Inverter/chargers. Inverters. MPPT solar charge controllers. Battery chargers. Battery monitoring.

Remote control and programming unit RCC-02 and RCC-03 for the Xtender User manual

Engineered power. Inverter-chargers. Inverters. MPPT solar charge controllers. Battery chargers. Battery monitoring.

Description Sets the priority for the AC source (AC1 or AC2) for qualification and transfer.

Application. Battery. Public Grid GS HYBRID INVERTER

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Photovoltaics. MPI Hybrid Series

How To Set Up SimpliPhi Batteries Using OutBack Chargers

IMEON 9.12 USER MANUAL

INVERTER/CHARGERS Off-Grid Power Solutions

User s and installer s Manual Sine wave Inverter, Battery charger, Transfersystem

Energy storage kits for residential and commercial customers. Ken Hobbs Technical Director, CCL Components Dean Kalek Technical Trainer, SMA Solar UK

The Intelligent Power Selector (IPS) converts any conventional Inverter into a Solar Inverter.

HYBRID S, OPEX REDUCTION & TOTAL ENERGY EFFICIENCY

Solar PCU/Inverter 1 KVA to 100 KVA

Schneider Electric Conext SW

Ningbo Star Solar Co.,Ltd Tel:(86) Fax:(86)

Using Inverter Input Modes for Smart Grid Management

Engineered power. Inverter-chargers. Inverters. Catalogue. Battery monitoring. Battery chargers. Battery splitters. Battery separators

User and installer Manual Combi Inverter, Battery charger and Transfersystem

VarioString. MPPT solar charge controller VS V- 120A. User manual

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

Energy Storage and Other Energy Control Solutions

Ag Features. Multi-Stage Charging. Solar Panel or DC Input. Maximum Power Point Tracking (MPPT) Very Low Power Consumption

K50. Technical Sheet

HOW TO USE H5000B TO RUN 5KW OF ENPHASE M250 OFF-GRID

Custom Power Solar Radian Battery Energy Storage System

DANGER. The Conext products below can utilize Load Shedding and Load Shifting:

Alphapower HTU UPS. Some key features include:

TROJAN BATTERY COMPANY Renewable Energy Warranty Claim Form

VarioString. MPPT solar charge controller VS V- 120A VS V- 70A. User manual

POWER. Inverters.

MPPT75HV MAXIMUM POWER POINT TRACKING SOLAR BATTERY CHARGE CONTROLLER

MED-Solar: Amélioration de la connexion des systèmes photovoltaïques au réseau électrique du Liban, Jordanie et Palestine

Using Inverter Input Modes for Smart Grid Management

OFF-GRID Hybrid (BI-DIRECTIONAL) SOLAR INVERTER SOLAR INVERTER SOLAR UPS

SMA Utility Power System

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

Tel: Whatsapp/Wechat: Skype:carrie.rong

Faster charging with solar power even during AC mains outage MPPT* controller to maximize solar energy harvest(3k/5k) Clear charging status on LCD

swissmango Solar Home Systems Power your Home with the Sun when the Electricity Supply Fails!

THE SELF USE SMART GRID INVERTER NEW GENERATION

The power to be independent. Grid Independence Outstanding Reliability Ultimate Flexibility

Combi Series Interactive Inverter-Chargers

ML Maximum Power Point Tracking (MPPT) Series ML2420-ML2430-ML2440 Solar Charge and Discharge Controller

INGECON SUN STORAGE 1PLAY

Power Generation. PowerStore Renewable microgrid stabilization

Power Conversion System The Best Technology for your photovoltaic and storage system

X600. Technical Sheet

Engineered power. Inverter-chargers. Inverters. Catalogue. Battery monitoring. Battery chargers. Battery splitters. Battery separators

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

PV System Components. EE 495/695 Spring 2011

VarioTrack VT /24/48V- 65A

Installation. Products for private- and business clients

BOOST POWER 1212 Product Description

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

:43 1/13 Victron & BYD B-Box

USER S MANUAL SOLAR POWER INVERTER KW-6KW

Where Space Design see the future of renewable energy in the home

SimpliPhi Power PHI Battery

Solar Inverter Manual

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

MODEL NUMBER: APS2424

LOW COST LIGHTING BRILLIANCE - A REVOLUTION IN SOLAR ENERGY. s o l a r s y s t e m s T H E S O L L AT E K A R E V O L U T I O N I N L I G H T I N G

MODEL NUMBER: APS2012

X400. Technical Sheet

Magellan Utility Scale Energy Storage

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

Building a DC Uninterruptible Power Supply for Your Ham Shack

DRAFT. Guidelines on Power quality & safety issues in usage of roof-top solar pv system CENTRAL ELECTRICITY AUTHORITY

Rugged MPPT Solar Energy Harvester

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

APPENDIX: APPROCIMATR BACK-UP TIME TABLE

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Demonstration PV rural microgrids project in Chad (Central Africa)

WEB ENABLE ONLINE DATA LOGGER AND REMOTE MONITORING FOR 66 KW ON GRID SOLAR PV SYSTEM

AIR CONDITIONING AND SOLAR ENERGY EQUIPMENT. Solar power generator

VarioTrack VT /24/48V- 65A

SimpliPhi Power PHI Battery

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

CBI All in One DC UPS Power Solutions

Duo Battery Charge Controller

Transcription:

Optimal solar backup General description This application note describes how, in a backup system, to use renewable energy even when the system is connected to a grid and the grid feeding is not possible. Features & advantages Ideal for backup system with renewables where there is no feed-in tariff or where grid feeding is not possible. Use all of the renewable energy available. Direct use of renewable energy without cycling energy in the battery(ies) to avoid their premature aging. Minimal configuration Range of inverters o All Xtender Series Xtender o Software vers. : 1.3.28 and higher RCC-02/-03 o Software vers. : 1.3.32 and higher o RCC User level : EXPERT Application Schematic (Figure 1) Backup system using renewable energy without grid feeding AN-002-V.1.8.3-10 STUDER INNOTEC SA Page 1 / 7

Detailed description Operation description In a backup system, the power to the end consumer is taken from the input (grid, generator ) or, in a blackout situation, from the DC side (battery(ies), renewables). Generally, in the case where grid feeding is not possible, the renewable energy is lost when the system is powered from input. This application note shows the possibility to use the renewable energy of the system even when the system is connected to a grid. This operation requires an inverter-charger from Xtender series with two special functions. The Smart-Boost i function which adds power to the AC source according to the input limit current. The solar priority function which adjusts the instantaneous power consumed from the source according to the battery(ies) voltage. The operation of the solar priority function is done with an automatic modification of the input limit current. The input limit current is decreased from the initial value (given by the user) if there is enough energy available at the DC side. The lower the input current, the more the load is provided with DC power by the Smart-Boost function. In this way, the power from the DC side is integrated in the system and the input consumption is limited. (Figure 2) Smart-Boost function Battery priority voltage, description and dimensioning The point where the input limit starts to decrease is the priority voltage of the battery(ies), parameter {1297} ii. This parameter sets two zones in a battery(ies) : A zone below this point, which ensure an energy reserve for a blackout situation. A zone above this point where the renewable energy in excess can be stored. When there is higher production of renewables than power consumed, it is possible to store this production in the battery(ies) s buffer zone for later use (see figure 4). (Figure 4) Load profile with renewable energy buffered An example to determine the value of the battery(ies) priority voltage considering a battery(ies) of 24Vdc (Full battery(ies) = 25.5Vdc, empty battery(ies) = 24Vdc) and a backup zone of 80% of the total capacity of the battery(ies) : -Full battery(ies) (Full bat ) = 25.5Vdc -Empty battery(ies) (Empty bat ) = 24.0Vdc Battery(ies) priority voltage is : Empty bat + 80% * (Full bat Empty bat ) = 24 + 0.8 * (25.5 24) = 25.2Vdc Note that even with the battery priority voltage, the battery charging proceeds normally and accepts the absorption and equalization phases. Thus, it is possible to program absorption and equalization phases to reduce the problem of stratification of the acid and the water decrease in the batteries. But to avoid cycling the batteries too often, it is necessary to adjust the parameter {1297} (Battery priority voltage) to a value higher than the parameter {1143} (Battery voltage level 1 to start a new cycle). (Figure 3) Battery priority voltage Page 2 / 7

Saving the renewable energy or the battery(ies) life? In such a system, there is the choice between storing or not the renewables in excess. If renewable energy is stored, energy in the battery(ies) will therefore be cycled, implying a decrease of the battery(ies) lifetime. If renewable energy is not stored, it will be lost but the energy in the battery(ies) will be stable, implying an extension of the battery(ies) lifetime. The question is whether to store the excess renewable energy not? Where the price of battery(ies) storage is cheaper than the cost of grid/generator energy, it is advisable to store the renewables in excess. Otherwise, if grid/generator energy is cheap, it is advisable not to store the renewables in excess. If the renewable energy production in excess is not buffered (Figure 5), the battery(ies) priority voltage should be set, for example, to 0.5Vdc below the floating voltage of the solar/wind regulator. The battery(ies) priority voltage should also be set to 0.5Vdc below the floating voltage of the solar/wind regulator to keep it loaded to a maximum. Operating example For example, if battery(ies) are higher than the priority voltage and if a solar panel is connected to the battery(ies) at the DC side, its regulator (MPPT or other) provides solar power to the DC-bus. At the same time, the Xtender will take away the solar power to maintain the DC-Bus at the priority voltage. This represents a direct use of the solar power in the final user load, without cycling energy in the battery(ies). If battery(ies) are lower than the priority voltage, solar power is used to recharge the battery(ies). Charging from the grid is now allowed because the objective is to keep the battery(ies) charged for backup time (generator is off, blackout, no more sun, ). For proper functioning of the system, the voltage target of the solar/wind regulator should therefore be above the battery(ies) priority voltage. Solar priority function s algorithm The solar priority function s algorithm maintains the battery(ies) at a proper level for long lifetime and always keeps a reserve of energy for backup. The input limit is reduced linearly over a working range as shown in the graphic below : (Figure 5) Load profile without renewable energy buffered Another case concerns the situation where there is no excess renewable energy (Figure 6). (Figure 4) Graph of Solar priority function. (Current taken on the AC source depending on the battery(ies)) (Figure 6) Load profile without excess of renewables Page 3 / 7

Parameters Four parameters iii allow controlling the energy management with different sources : 1. Battery(ies) priority as energy source {1296} 2. Smart-Boost allowed {1126} 3. Battery(ies) priority voltage {1297} 4. Maximum current of AC source (Input limit) {1107} Notes Associated application notes : AN001 AC source assistance (Smart Boost function) i ii iii More information about the Smart-Boost is available on the AN001 AC source assistance (Smart-Boost function) The voltage values for the battery(ies) priority voltage {1297} are available at the next page, item : Battery(ies) priority voltage More information about the source max AC current and the battery(ies) priority voltage are available at the next page Page 4 / 7

RCC -02 / -03 programming guide 1. User level to EXPERT 3. Batteries priority as energy source User level {5012} Press SET and insert the code : SYSTEM {1101} i The code is available in the user manual RCC -02 / -03 426468 Your level is EXPERT Press SET : Batteries priority as energy source {1296} Your batteries are the priority energy source Press SET, selection Yes with and press SET : 2. Smart-Boost allowed 4. Battery priority voltage Basic settings {1100} SYSTEM {1101} Smart-Boost allowed {1126} The Smart-Boost is allowed Press SET, selection Yes with and press SET : Battery priority voltage {1297} Your battery voltage is at the right value Press SET, adjust the desired value with and press SET : Page 5 / 7

5. Maximum current of AC source (Input limit) Basic settings {1100} Maximum current of AC source (Input limit) {1107} Press SET, adjust the desired value i with and press SET : Your input current is adjusted i The current value [Aac] must be set according to the size of the circuit breaker or the grid capacity Page 6 / 7

Notes Worldwide sales and service Switzerland Studer Innotec SA Rue des Casernes 57 1950 SION / Switzerland Tel :027 205 60 80 / Fax : 027 205 60 88 Email: info@studer-innotec.com Web : http://www.studer-innotec.com Limitation of responsibility The use of STUDER INNOTEC SA devices is the responsibility of the customer in all cases. STUDER INNOTEC SA reserves the right to make any modifications to the product without prior notification. Page 7 / 7