Waterfall Pumps Manufacturing

Similar documents
Bristol: A History & Future.

Centrifugal End Suction Fire Pumps

900 Series Split Case Fire Pump Systems

F-Series Fire Fighting Pumps

SUGGESTED SPECIFICATIONS

340 Series Double Suction Split Case Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

PRODUCING TRUST IN FIRE AND SAFETY FIRE PUMP SYSTEMS A PRODUCT OF COMPLIANT.

3312 Model. pumping Model Model AURORA Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS

University of Houston Master Construction Specifications Insert Project Name

PA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD.

PRODUCT OF FIRE PUMPS SYSTEMS

Contents. Identification

Goulds Small Capacity Double Suction Pump

Fire Protection. FP-XA End Suction

SM / SMI N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

Series 4600F. HSC Fire Pumps & Packaged Systems

Axially Split Case Pumps

DARTMOUTH COLLEGE DESIGN February 15, 2006 & CONSTRUCTION GUIDELINES

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

4500C Series Vortex Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CRP. Chemical Centrifugal Pump Acc. to DIN EN ISO 2858 & DIN EN ISO 5199

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

FIRE PUMPS & PACKAGED

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPP. Heavy Duty, Single Stage ANSI Chemical Process Pump

Fire Pump Systems. For the protection of life and property, A-C Fire Pump offers package systems that meet every fire protection need.

G&L Pumps. TECHNICAL Brochure BAC8100. Series A-C 8100 SPLIT CASE PUMPS

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

Bulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

FIRE PUMPS F AI LISTED R LISTED N K S MOR S E P U IT Y S Y S T E M CE R T IF IE D

Goulds 3181 High-temperature/Pressure Paper Stock/ Process Pumps

Goulds Double Suction Pumps

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

AURORA Series MODEL 3560 ASME/ANSI B73.1M INDUSTRIAL PROCESS PUMPS

Index - Section 14 End Suction Pump Semi-Open Impeller

Product Numbering System Typical Specifi cations, Models 4AC, 4AE, 6AC, 6AE, 8AC Pump Assembly, Types AC & AE

3800 Series. Single Stage End Suction Pumps. Capacities to 4200 G.P.M. (954 m 3 /hr) Heads to 520 Feet (180 Meters) Temperatures to 300 F (149 C)

Goulds 3186 High-temperature/Pressure Paper Stock/ Process Pumps

320 Series Vertical Sump Pumps

900 Series. 2000/2500 GPM High Head. Expanding our line to meet your needs. Model Latest Addition to the Aurora Fire Pump Line

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

High Temperature Chemical Process Inline Pumps

CLOSED COUPLED CENTRIFUGAL PUMPS

SJP Vertical Propeller Pumps

Data sheet. Customer item no.: Communication dated: Number: ES Doc. no.: Item no.: 100 Quantity: 1 Date: 19/03/2015 Page: 1 / 6

CLOSED COUPLED CENTRIFUGAL PUMPS

Basic Hydraulic Features. Basic Mechanical Features

PWD. PWD API 610 BB1 Single Stage Pump

TECHNICAL BROCHURE BAC2000. Series 2000 Closed Coupled. Series 2000 Frame Mounted. Series A-C 2000 SINGLE STAGE END SUCTION

PROCESS PUMPS MODEL V200 ANSI B73.2

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5

HORIZONTAL SPLIT CASE SINGLE STAGE DOUBLE SUCTION Type AE CHECKING LIST

High-Temperature and Pressure Paper Stock / Process Pump

MBN Medium Pressure Stage Casing Pump

PWA-IL B73.2 IN-LINE

Series HSC-S Pumps Technical Brochure

PROJ. NO SECTION HYDRONIC PUMPS

Goulds 3610 API 610/ISO Axially-Split, Between-Bearing, (BB1) Pump

One & Two Stage Turbine Type Pumps

OHV and OHVL Vertical Inline Pumps ISO (API 610)

Model 3550 ASME/ANSI B73.1M Industrial Process Pumps

EFQT/EFQU. EBARA Self Priming Trash Pump. Contents Project: Model: Chk d: Date:

Vertical Pumps for the Oil & Gas Industry

FLHC SERIES DATA BOOKLET

Goulds API th Edition / ISO nd Edition API BB2 Single-Stage, Between-Bearing, Radially Split

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

BBT/BBT-D Two Stage Radially Split Between Bearings Process Pump API 610, 9th Edition (ISO 13709)

AURORA 3500 SERIES MODEL 3550 ASME/ANSI B73.1 INDUSTRIAL PROCESS PUMPS

KSMK. Between-Bearings, Multistage, Radially Split Double Volute Pump. BB2 Type. API-610,10th edition ISO M A R E L L I

POWERFORCE PUMP POWERFORCE PUMP POWERFORCE PUMP GLOBAL SOLUTIONS DESIGNING, MANUFACTURING AND PACKAGING FOR THE OIL & GAS INDUSTRY

CENTRIFUGAL PROCESS PUMPS MODEL A100 ANSI B73.1

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

SCE Heavy Duty, Single Stage, Overhung, API 610 Process Pump (OH2)

PUMP TYPE Single stage, axially split volute casing pump with double entry radial impeller, for horizontal installation.

RS Series Multi-stage, Ring Section Pump For Pressures to 1,500 PSI

FIRE PUMP SYSTEMS. FIRE PUMP SINGAPORE PTE LTD No.8 Keng Chin Road #13-11 Cyan South Tower Singapore

ZPP and Z22 Double Suction Axially Split Single Stage Centrifugal Pumps

Goulds Lenntech. API th Edition / ISO nd Edition API BB2 Two-Stage, Between-Bearing, Radially Split

Corbrasion resistant, high performance slurry pumps Designed for solids laden waste water to aggressive slurries

Wilo CO-Helix Pressure Boosting Systems. Engineering Specification

barmesapumps.com WHAT IS AN ANSI PUMP

Goulds High-Pressure Multi-Stage Pumps

SINCE Double Suction Split Case. Series 4800 & (New Generation) cat-2016-dssc

TECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

1100 Series Multi-Stage Vertical Turbine Pumps

Fire Pump Capabilities N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

High Temperature Air-Cooled Hot Oil Pumps

PumPs. jacketed molten sulfur PumPs. Pumps Mixers Strainers Engineered Systems and Controls.

SJT/SJM CWP Vertical Pump

EN. 850 Filtrate Pumps. Technical Specification Pages

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Series 1510 Centrifugal Pumps

Goulds 3640 ISO nd Edition/API th Edition API BB2 Two-Stage, Between-Bearing, Radially Split

VSC /VSCS Pumps Technical Brochure

Goulds API th Edition/ISO nd Edition API OH3 Overhung. Vertical In-Line with Bearing Frame. An ITT Brand

Data sheet. Omega B GB G F Version no.: 1. Operating data. Design. Driver, accessories. Clean water. Actual developed head 57.

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

Transcription:

Waterfall Pumps Manufacturing Our Vision for the future to become the world s premier provider of fire protection pumps. Our ongoing mission is to be the customers first choice, a trusted provider and recognized global leader of fire protection pumps. Being a global leader enables us to provide valued solutions, quality products and service, in a cost effective manner to satisfy the needs of our clients.

Product Overview WATERFALL is an innovative and efficient centrifugal Pumps Manufacturer that offers operators of pumps systems a wide range of quality products. Our product line complies with the most demanding quality standards and industry specifications and built as per NFPA 20 and listed by Underwriters Laboratories. WF Horizontal Split Case Pumps offer higher efficiencies, more reliable operation and low maintenance, constructed with double inlets that practically eliminate and thrust while boosting operation efficiency. Their simplicity of design allows for inline service without disturbing piping and ensure long efficient unit life and minimum power consumption. Split case pumps can be driven by either an electric motor or diesel engine with a full range of options and accessories available to complete the NFPA-compliant fire pump. Heavy fabricated steel bases, are available to mount the pump and driver along with flexible coupling connects driver to pump. Split Case Fire Pumps are specified when the source of water is located above the surface of the ground and provide a positive suction pressure to the pump at any performance point. Intensive research and development ensures that the products of WF Pumps are continuously improved to meet the latest technical requirements. Instant availability of spare parts, together with first class service, assures customer that they have selected the right partner. A highly trained and experienced research team is backed by a fully equipped laboratory for conducting rigorous performance and endurance testing.

Selection Criteria According to NFPA20, the characteristic curve of fire pumps is defined by: 150 140 Shutoff Head capacity curve with steepest shape permissible Flat head capacity curve Shut-off head: The Shut-off head shall not exceed 140 percent of rated head for any type of pump. Rated Pressure / rated flow: pump characteristic curve must pass through or above the point where rated flow rate and rated pressure values intersect each other. Percent rated total head 100 65 50 0 Rated capacity Percent of reted capacity Rated total head 0 50 100 150 200 Overload: Pumps shall furnish not less than 150 percent of rated capacity at not less than 65 percent of the total rated head. As required by NFPA20, each pump is tested at our factory to provide detailed performance data to demonstrate its compliance with the required specifications. In compliance with NFPA20, hydrostatic tests are performed on the pump for a period of not less than 1 minute. Driver rated horse power shall be determined also for operational conditions, where flow rates which are at the order of 150% of the rated flow, are reached. Each pump shall have a label: rated pressure, rated flow, rotational speed and driver service factor being engraved on it. Each pump shall be equipped with pressure gauges that indicate suction and discharge pressure. Pressure relief valve shall be used only where a diesel engine fire pump is installed. Each pump shall be equipped with casing relief valve, to be used for cooling purposes at shut-off pressures. Pump-drive couplings and other movable components must be protected with guards.

Cross Section Details 1. CASING: The rugged heavy duty, two pieces casing is matched and split horizontally along the centerline of the shaft. 2. IMPELLER: Double suction, enclosed, dynamically and hydraulically balanced prior to the assembly. Impellers are firmly keyed and locked to an accurately finished oversized shaft to absorb all shock loads. 3. SHAFT: High strength steel, grounded and polished to a smooth surface, design to transmit full driver horsepower with a liberal safety factor and minimum deflection. 4. SHAFT SLEEVE: Easily replaceable centrifugally cast sleeves protect the shaft from packing wear, and are sealed to prevent leakage. Sleeves are accurately positioned and locked in place. 5. STUFFING BOX: Accommodate with square rings of packing with a lantern ring. Stuffing box is completely removable and replaceable with rotating assembly. 6. LANTERN RING: A perforated hollow ring that receives relatively cool, clean liquid. Distribute uniformly around the shaft to provide lubrication and cooling. 7. GLAND PACKING: flexibility allows the shaft to run freely as well as leak proof. 8. BEARING: single-row, cartridge mounting, maintains impeller in their central position, grease type lubrication standard. 9. BEARING HOUSE: both the inboard and outboard bearing are protected by lip seals to keep contaminants out of bearing. Completely replaced without disturbing any other part of the rotating assembly.

General Information FEATURES: Suction and discharge flanges are on a common center line. Easy access to all working parts. Rugged construction. Efficient operation. Self-venting design. Dynamic balanced Impeller. Performance and hydrostatic test. Space saving design. Available in 50 or 60 Hz. TECHNICAL DATA PUMP DESIGNATION Suction nozzle DN 125 DN 200 WF 5 3 10 HS Discharge Nozzle DN 80 DN 125 Operating Pressure 82 346 PSI Capacity Range 300 1500 GPM Pump Name Suction nozzle Discharge nozzle Impeller Diameter Pump Type

Pump Dimensions Front View Side View Pump - Table of Dimensions (mm) PUMP MODEL A B Ct Cs E F G Ds Dd J L C M N iø K WF-5X3X10 HS WF-6X4X12 HS WF-8X5X11 HS 300 300 270 140 410 170 70 125 80 346 441 315 320 135 35 10X10X78 300 330 345 170 480 200 80 150 100 346.3 453.5 355 320 135 35 10X10X78 370 370 310 200 530 225 80 200 125 365 516 400 390 170 45 14X14X108 WF-6X3X14 HS 370 340 310 180 460 190 80 150 80 366 468 333 350 135 35 10X10X78 WF-8X4X17 HS 450 405 362 225 580 240 100 200 100 553 403 425 400 160 45 14X14X108

Pump Dimensions Flange - Table of Dimensions (mm) PUMP MODEL SUCTION DISCHARGE ID OD dp ID OD dp WF-5X3X10 HS 125 280 8-holes Ø22 on 235 pcd 80 210 8-holes Ø22 on 168 PCD WF-6X4X12 HS 150 320 12-holes Ø22 on 270 PCD 100 255 8-holes Ø22 on 200 PCD WF-8X5X11 HS 200 380 12-holes Ø26 on 330 PCD 125 280 12-holes Ø26 on 235 PCD WF-6X3X14 HS 150 280 8-holes Ø23 on 241 PCD 80 210 8-holes Ø23 on 168 PCD WF-8X4X17 HS 200 380 12-holes Ø26 on 330 PCD 100 255 8-holes Ø26 on 200 PCD

Electric Driven Pump

Diesel Driven Pump

Commited to Success Waterfall pumps remains committed to designing & developing innovative products to serve the clients needs