Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

Similar documents
CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

Item 1: Contents of the complete training & CV of the lecturer

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

A List of Standards Often Used for Designing Electrical Systems and for Specifying Equipment

j Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Independent Testing Laboratory for High Voltage Equipment

SWITCHBOARDS (LV and MV)

INTERNATIONAL STANDARD

HMI, APRIL, Test Laboratories in Ratingen

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

power cable accessories

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

GB/T Translated English of Chinese Standard: GB/T

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

NPS/001/017 Technical Specification for Low Voltage and High Voltage Current Limiting Fuse Links

Metal Clad Switchgears

Documents and Addresses

INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

SUBSTATION DESIGN TRAINING

Pretest Module 29 High Voltage Unit 1

The Deutsche Akkreditierungsstelle GmbH attests that the testing laboratory

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

3TM Vacuum Contactors

STANDARDS SOUTH AFRICA. Amendment No. 5 : May SANS :2006 (Ed 1.5) THE WIRING OF PREMISES PART 1: LOW-VOLTAGE INSTALLATIONS

The comprehensive portfolio of the testing laboratories at Schaltwerk Berlin siemens.com/energy/psw

Nexans Network Solutions Div. Euromold

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

High Voltage and Extra High Voltage Cables

NXPLUS C Single busbar. Maintenance-free for lifetime


Prüffeld der Schaltwerke

List of Mandatory Commercial Documents ITEM DESCRIPTION REQUIRED ITEM DRAWING DOCUMENTS NAME REQUIRED ITEM TEST DOCUMENTS NAME

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Air-insulated switchgear UniGear type ZS1

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Unified requirements for systems with voltages above 1 kv up to 15 kv

Zinc Oxide Surge Arrester EXLIM R

SOUTH AFRICAN NATIONAL STANDARD

Distribution transformers Efficiency over life-cycle

Collection of standards in electronic format (PDF) 1. Copyright

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

Medium Voltage. Joints & Terminations

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

a Nexans company Catalogue 2009

3 TM Cold Applied Barrier Boot System

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Zinc-Oxide Surge Arrester TEXLIM Q-C

Steve Summers Region Sales Manager

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

PRE-AMBLE TO THE STANDARD SPECIFICATION FOR MEDIUM AND LOW VOLTAGE ELECTRICITY DISTRIBUTION WORKS

S.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not

MOBILE SUBSTATION GUIDE

Modular Substation Technical Data. Modular Substation. Technical Data TGOOD

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

DRAFT: SOUTH AFRICAN NATIONAL STANDARD

FAQ S. Main Switchboard Design Criteria. ENGINEERED SOLUTIONS FOR ALL YOUR SWITCHBOARD NEEDS

Sharda Electronics & Co. An ISO 9001:2015 Certified Company

MEDIUM VOLTAGE SWITCHGEAR

Power distribution. General remarks

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

a Nexans company Medium voltage symmetrical separable connectors - Interface C -

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

List of Malaysian Standard (MS) for Cables. Prepared by MCMA SWO. Cable - Armoured. Cable - Armoured

Effective discrimination of protective devices

Gas Insulated Metal-clad Switchgear, HMGS!

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY

Ref No: Date: February 8, 1995 INDUSTRIAL CONTROL EQUIPMENT NO. 2

Unitole UP kv Primary substations Motor control centres

132/11 kv, 25 MVA MOBILE SUBSTATION

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

THORNE & DERRICK UK TEL FAX TEL FAX

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

Unitole UP kv Primary substations Motor control centres

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

DC in the LV network: cable challenges. Antonios Tzimas Dimitris Antoniou Simon Rowland

Transforming Energy.. For Advanced Technology

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

a Nexans company Catalogue 2007

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Technical Specification

Transcription:

Page 1 of 6 Site(s) applicable to the recognition: Central Power Research Institute Prof Sir C.V. Raman Road P.B. No. 8066 Sadashivanagar Sub-P.O. Bangalore 560 080 India Central Power Research Institute Switchgear Testing & Development Station Govindpura Bhopal 462 023 India Scope of recognition (generic products): All Low Voltage Switchgear, Circuit-Breakers, Switches, Disconnectors, Contactors, Fuse Combinations, Fuses, Fuse-Links, Switchgear and Controlgear Assemblies, Busbar Trunking, Motor Starters, Control Circuit Devices, Switching Elements, Transformers and Reactors, Low Voltage, Medium Voltage and High Voltage Power Cables, Cable Joints and Terminations, High Voltage Power Transformers, Alternating Circuit-breakers and A.C. Metal Enclosed Switchgear and Controlgear. Conditions applicable to the recognition: The recognition of the Laboratory is subject to the NABL Accreditation No. T-0010 and T-0011 remaining valid for the above product types.

Page 2 of 6 CENTRAL POWER RESEARCH INSTITUTE, BANGALORE (SHORT-CIRCUIT LABORATORY) Circuit breakers IEC 60947 (: 2011 & : 2013) Switches IEC 60947 (: 2011 & : 2012) Disconnectors Switch Disconnector & fuse combination units Contactors & Motor Starters IEC 60947 (: 2011 & Part 4-1: 2012) IEC 60947-4-2: 2011 Control circuit devices & switching elements IEC 60947 (: 2011 & Part 5-1: 2009) Low voltage switchgear & control gear assemblies General Rules IEC 61439-1: 2011 Power Switchgear & Controlgear Assemblies Distribution Boards Intended To Be Operated By Ordinary Persons (DBO) Particular Requirements For Assemblies For Construction Sites (Acs) Assemblies For Power Distribution In Public Networks IEC 61439-2: 2011 IEC 61439-3: 2012 IEC 61439-4: 2012 IEC 61439-5: 2010 Busbar Trunking Systems (Busways) IEC 61439-6: 2012 except clauses 10.101 & 10.102 Electrical Accessories-circuit breakers for over current IEC 60898-1: 2003 protection for household and similar installations IEC 60898-2: 2003 Circuit breakers for equipment (CBE) IEC 60934: 2000 Residual current operated circuit breaker IEC 60755: 1983 IEC 61008-1: 2012 IEC 61008-2-1: 1990 IEC 61008-2-2: 1990 IEC 61009-1: 2013 IEC 61009-2-1(1991) IEC 61009-2-2 (1991) Power transformers up to 1000 kva, 11kV Part 4 Part 5 General Temperature rise Insulation levels, dielectric tests and external clearances in air Guide to the lightning impulse and switching impulse testing Ability to withstand short circuit IEC 60076-1: 2011 IEC 60076-2: 2011 IEC 60076-3: 2000 IEC 60076-4: 2002 IEC 60076-5: 2006

Page 3 of 6 CENTRAL POWER RESEARCH INSTITUTE, BANGALORE (CABLES LABORATORY DCCD) Instrument transformers : : General Requirements Additional Requirements For Current Transformers IEC 61869-1: 2007 IEC 61869-2: 2012 Power Cables & Cable accessories Power cables with Extruded Insulation and accessories for voltages 1 kv and 3 kv Power cables with Extruded Insulation and accessories for voltages from 6 kv up to 30 kv Part 4 Power cables with Extruded Insulation and accessories for voltages from 6 kv up to 30 kv Test Requirements on accessories for cables with rated voltages from 6 kv Power cables with Extruded Insulation and their accessories for rated voltages above 30 kv up to 150 kv Test Methods and Requirements Power cables with Extruded Insulation and their accessories for rated voltages above 150 kv up to 500 kv Test Methods and Requirements Paper Insulated Metal Sheathed Cables for rated Voltages up to18/30 kv Tests on cables and accessories IEC 60502-1: 2009 IEC 60502-2: 2005 IEC 60502-4: 2010 IEC 60840: 2011 IEC 62067: 2011 IEC 60055-1:1997 Am1 2005 Partial discharge Measurement Instrument transformers- Current transformers (up to 132 kv) IEC 61869-2: 2012 IEC 61869-1: 2007 Metal Oxide surge Arrestors with out gaps for a.c Systems ( Up to 132 kv) IEC 60099-4 -2009 BS Specifications Cables with Extruded XLPE or EPR insulation for rated voltages from 3800/6600 V up to 19000/33000 V BS 6622: 2007 600/1000 V and 1900/3300 V armoured electric Cables having PVC insulation 600/1000 V and 1900/3300 V armoured electric Cables having thermosetting insulation Test Methods and Requirements for accessories for use on distribution Cables of rated voltages 0.6/1.0 (1.2) kv Test Requirements on accessories for use on Power Cables of rated voltages from 3.6/6 (7.2) kv up to 20.8/36 (42) kv BS 6346: 2012 BS 5467: 2008 BS EN 50393: 2006 CENELEC HD 629.1 S2-2006

Page 4 of 6 CENTRAL POWER RESEARCH INSTITUTE, STDS, BHOPAL Low voltage fuses Part 4 General requirements Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) Examples of standardized systems of fuses A to I Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) Examples of standardized systems of fuses A to F Supplementary requirements for fuse links for protection of semi conductor devices IEC 60269-1: 2009 IEC 60269-2: 2010 IEC 60269-3: 2013 IEC 60269-4: 2012 Low voltage switchgear & control gear Part-4-1 Part 4-2 Circuit breakers Switches, Dis-connectors, Switch dis-connectors & fuse combination units Contactors and motor starters-electromechanical contactors and motor starters Contactors and motor starters-ac semi conductor motor controllers and starters IEC 60947-1: 2011 IEC 60947-2: 2013 IEC 60947-3: 2012 IEC 60947-4-1: 2012 IEC 60947-4-2: 2011 Electrical accessories-circuit breakers for over current protection for household and similar installations Circuit breakers for AC operation IEC 60898-1: 2003

Page 5 of 6 CENTRAL POWER RESEARCH INSTITUTE, STDS, BHOPAL (CONTINUED) Low voltage switchgear and control gear assemblies Power Switchgear And Controlgear Assemblies Distribution Boards Intended To Be Operated By Ordinary Persons (DBO) Particular Requirements For Assemblies For Construction Sites (Acs) Assemblies For Power Distribution In Public Networks IEC 61439-1: 2011 IEC 61439-2: 2011 IEC 61439-3: 2012 IEC 61439-4: 2012 IEC 61439-5: 2010 Busbar Trunking Systems (Busways) Residual current operated circuit breakers without integral Over-current protection for household and similar uses (RCCBs) -1 Applicability of the general rules to RCCBs functionally independent of line voltage -2 Applicability of the general rules to RCCBs functionally dependent on line voltage IEC 61439-6: 2012 except clauses 10.101 & 10.102 IEC 61008-1: 2012 IEC 61008-2-1: 1990 IEC 61008-2-2: 1990 Residual current operated circuit breakers with integral Over-current protection for household and similar uses (RCBOs) -1-2 Applicability of the general rules to RCBOs functionally independent of line voltage Applicability of the general rules to RCBOs functionally dependent on line voltage IEC 61009-1: 2012 IEC 61009-2-1: 1991 IEC 61009-2-2: 1991

Page 6 of 6 CENTRAL POWER RESEARCH INSTITUTE, STDS, BHOPAL (CONTINUED) High voltage switchgear and control gear 00 00 High voltage alternating current circuit breakers AC metal enclosed switchgear & control gear for rated voltages above 1 kv and up to and including 52 kv IEC 62271-100: 2012 IEC 62271-200: 2011 High voltage fuses Current limiting fuses Expulsion fuses IEC 60282-1: 2009 IEC 60282-2: 2008 Power transformers Part 4 Part 5 General Temperature rise Insulation levels, dielectric tests and external clearances in air Guide to the lightning impulse and switching impulse testing Ability to withstand short circuit IEC 60076-1: 2011 IEC 60076-2: 2011 IEC 60076-3: 2000 IEC 60076-4: 2002 IEC 60076-5: 2006 Instrument transformers : : General Requirements Additional Requirements For Current Transformers IEC 61869-1: 2007 IEC 61869-2: 2012