Limit switches Position product description Position Limit switches page 36 to 42 The position (rotary-angular) limit switch is used to control several handling system: sophisticated crane system: the unit controls power operating system (ex. PLC) and allows the crane to slow-down and/or to stop running. hoist: the unit is used to stop the hoist running whenever it reaches a limit position Different combinations available for all standard system. Customization available on request. How it works? moving device As an example, an FCR6 is typically used on a sophisticated crane system. Its function is to control the crane as it approaches operational limits in the following sequence: With the crane moving forward the end position, the FCR6 controls the crane s reducing the (first step) than stopping the crane (second step). In this position the forward command is no longer enabled. Only the reversing command is enabled for operation, in the first than in the second. Picture shows a FCR working on a crane system 36 Example FCR6 FORWARD 1 step reduce the 2 step stop the system REVERSE Go in first than, asap the FCR change pos., in the second Picture shows a FCP working on a hoist
Position - table of contents Line FCR FFH FCP Page 38 4 41 Picture X-ray view Characteristics Standards IEC/EN 6947/3 IEC/EN 6947/3 IEC/EN 6947/3, EN81-1 V UL94 self extinguishing cover V UL94 V UL94 IEC/EN 6529 enclosed thermal current[ithe] 16A 2A 4A Cam switch rated insulation voltage[ui] product ID 69V 69V 69V P16 PX2 CX4 contacts markings Cable entry N 1 dia. 22.5mm 1xM2 + 1xM16 M2 (max 8) -single or double motor configuration - 3,4 or 4 withmechanical stop positions single motor configuration two pole on-off switch fully adjustable aluminium rods 6x3mm with indicator - fully adjustable metallic rods 6x12mm -rubber covering wheel 37
Picture Position switch FCR contact open contact close FCR1 single -9 +9 X-ray view FCR2 single 7-8 5-6 -9 +9 Characteristics Cam switch Standards IEC/EN 6947/3 IEC/EN 6529 enclosed thermal current[ithe] rated insulation voltage[ui] product ID V UL94 16A 69V P16 FCR3 single FCR4 single 4 positions NO mechanical interlock 4 positions NO mechanical interlock 9 18 27 - empty 5-6 - empty 9 18 27 38 contacts markings Cable entry N 1 dia. 22.5mm -single or double motor configuration - 3,4 or 4 withmechanical stop positions fully adjustable aluminium rods 6x3mm with indicator Other versions available on request FCR5 single FCR6 two s 4 positions NO mechanical interlock 4 positions - empty 5-6 - empty 7-8 5-6 9 18 27-18 -9 +9 +18
Position switch FCR Dimensions Fixing holes Section view Rods adjusting guide ZERO indicator Reinforced mechanical stop insert I. Loosen the fourscews(1) II. Adjust the rods III. Tighten the four screws(1) 1 metallic stop insert metallic cam s control shaft 39
Picture Position switch FFH contact open contact close X-ray view FFH2C single automatic return to -65 +65 Characteristics Standards IEC/EN 6947/3 IEC/EN 6529 enclosed thermal current[ithe] V UL94 2A FFH2C-1 single automatic return to Other versions available on request Dimensions -65 +65 Cam switch rated insulation voltage[ui] product ID contacts markings 69V PX2 Cable entry 1xM2 + 1xM16 single motor configuration -fully adjustable metallic rods 6x12mm -rubber covering wheel Reinforced mechanical stop insert Section view Rod adjusting guide Fixing holes I. Loosen the four screws(1) 1 II. Adjust the rods 4 III. Tighten the four screws(1)
Picture Position switch FCP contact open contact close FCP245 single automatic return to -5 +5 X-ray view Characteristics Standards IEC/EN 6947/3 Other versions available on request Dimensions IEC/EN 6529 enclosed thermal current[ithe] V UL94 4A Cam switch rated insulation voltage[ui] product ID contacts markings 69V CX4 Cable entry M2 (max 8) two pole on-off switch Fixing holes Reinforced mechanical stop insert Section view metallic stop insert metallic cam s control shaft 41
Position switch Tecnical Data General characteristics FCR FFH FCP Markings Standards IEC/EN 6947/3 IEC/EN 6947/3 IEC/EN 6947/3 V UL94 V UL94 V UL94 IEC/EN 6529 Climate temperature Operating -25 C + 55 C Storage -3 C + 7 C Cable entry N 1 dia. 22.5mm 1xM2 + 1xM16 M2 (max 8) -single or double motor configuration - 3,4 or 4 withmechanical stop positions fully adjustable aluminium rods 6x3mm with indicator single motor configuration - fully adjustable metallic rods 6x12mm -rubber covering wheel two pole on-off switch Weight KG (approx).5.35.55 Electrical characteristics FCR FFH FCP Cam switch product ID P16 PX2 CX4 Standards IEC/EN 6947/3 UL58 IEC/EN 6947/3 UL58 IEC/EN 6947/3 UL58 Markings Enclosed thermal current[ithe] 16A 2A 4A Rated insulation voltage[ui] 69V 69V 69V Frequency 5/6 Hz 5/6 Hz 5/6 Hz Rated operating current AC21A-AC22A 16A - 69Vac 2A - 69Vac 4A - 69Vac AC23A3ph 23V 13A-4kW 16A-5kW 35A-11kW AC23A 3ph 4V 13A-7.5kW 16A-9kW 32A 18.5kW Rated short circuit withstand current(gg 2A -69V) 5kA 5kA 1kA Contacts caliber A3 (EN6947-1) A3 (EN6947-1) A5 (EN6947-1) Connections screw size M3.5 M3.5 M4 max torque.8 Nm(EN6947-1) 7.5 lb.in. (UL58).8 Nm(EN6947-1) 7.5 lb.in. (UL58) 1.2 Nm(EN6947-1) 1.6 lb.in. (UL58) 42 Connectable section flexible or solid min/max flexible or solid AWG 1x.75/4 2x.75/2.5 1x.75/4 2x.75/2.5 2x2.5/1 16-12 16-12 14-6