Battery Pack Charger OpenStage WL 3 / OpenStage WL3 Plus. Installation Guide A31003-M2000-J

Similar documents
4 WAY WIRELESS REMOTE CONTROL SYSTEM. User Manual

V-D2425 and V-D2440 Digital Clock

7.5 FT PRE-LIT ENGLEWOOD PINE TREE


USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

LED Recessed Troffer Retrofit Kit

Zebra. Look & Play. Instructions

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

Instruction Manual 03

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

L

Back-Up Sensor System

Sylvania 9 Color Changing One Plug Tree Tree ID # T5, Item # V

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

HERCULES ITEM NO UNBREAKABLE HELICOPTER AGES CHANNEL GYRO RC HELICOPTER FEATURES

FOR INDOOR/SEASONAL USE ONLY

M1800.

Jungle Pal. Music Mirror Product Number: 73462

AirVolt - P User s Manual. 3CH Mini Indoor Helicopter w/ Gyro. Ages 14+ and up

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

Use and Care Guide. Item #

Lots of Action in the Jungle!

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

& Mattel and Smart Toy LLC. All Rights Reserved. and designate U.S. trademarks of Mattel, except as noted. DNV

USE AND CARE GUIDE 4 FT. LED WRAP LIGHT

30in Phoebe Round Crystal Chandelier Assembly Instructions

Assembled Parts. Terminal Base. Barn Roof. Air Track with Tabs. 2 Barn Walls. Barn Base. 4 Air Tracks with Connectors. Air Track with Support

User s Manual. Cruise & Learn CarTM VTech Printed in China US

BATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL

Apple, iphone and ipad are trademarks of Apple Inc., registered in the U.S. and other countries. Android is a trademark of Google Inc.

Use and Care Guide. Item #

Understanding the Transmitter NO.S107H -1- ON/OFF Button Left Rotation Trimming. Right rotation trimming

Bounce & Spin ZebraTM

Soothe n Play. Model Number: B0771

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

User Guide. Digital Shipping Scale S150

7.5' LED Silver Glitter with Pinecones One Plug Tree V INSTRUCTION MANUAL

Installer Guide smart connect

L

AS-RFK2315. User Guide. Two-Way FM LED Remote System. Available functionalities depend on vehicle. Consult your dealer for more information.

Hendrickson Fit Adapter Installation Instructions

Clanky the Garbage Truck. Melody Mini Van. Lifty the Loader

Command Center. Model Number Helicopter, Motorcycle, equipment packs and figures sold separately.

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

POWERWARE User s Guide VA.

K4562 L1345

Playful Puppy Gym. H8268 Instructions.

Use and Care Guide. Part # UC SV-D Model # UC SV-d UC SV-d

X0056. fisher-price.com

Tummy Time. Sit & Play. Lay & Play. L1664

Instructions.

Use and Care Guide.

K7116

Please read and understand all precautions prior to use.

Upton LED Chandelier 40in Assembly Instructions

Press the buttons for fun sounds and music! fisher-price.com

Radio-Control Raceway

K0400

PROJECTOR WITH REMOTE CONTROL

Pop n Twirl Building Table. C3969 Instructions

fisher-price.com BMH49 CHY39 BMD80 Lay & play Take-along

J6666. CalcuBot.


User s Manual. Wave to Me Magic Wand. Years. Disney. Visit DisneyJunior.com VTech Printed in China US F.P.

Motorized Big Top Train

Crawl & Slide Arcade. B2408 Instructions

Enchanted Motion Musical Gym

Stand-Up Ball Blast TM

SKU# LC54225 Please retain these instructions for future reference. Adult assembly required.

Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries for operation (included).

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Y9854. fisher-price.com

Cab Control Operators Manual

Drop & Roar Dinosaur H

User s Manual. Clementine s Kitchen & Ice Cream Cart VTech Printed in China US. 500 IM_US.indd 1 08/05/ :48:5

Step1: Battery and Speaker Assembly Step 2: Pump and Battery Installation Step 3: Setting Up Your Fountain 6 Troubleshooting and Maintenance

Aquarium Bouncer. Model Number: 79030

OWNER S MANUAL Please read and understand all precautions prior to use.

FOR AGES 8 AND UP. 2.4GHz 3.5CH REMOTE CONTROL HELICOPTER ITEM NO

CFM96. fisher-price.com

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

3D VIEWER. Model H4159

WIRELESS SMART CHARGING PAD OPERATING INSTRUCTIONS PLEASE READ BEFORE OPERATING THIS EQUIPMENT

P

Monnit Wireless Range Extender Product Use Guide

V9961 V9961

Learning Mower K7165.

CHG26 IMAGINEXT. Requires four AA (LR6) alkaline batteries (not included) for operation.

User s Manual. Deluxe Car Carrier TM VTech Printed in China

Go! Go! Smart Friends

K4074. Teaching Clock.

DOOR LIMITS A) ENGAGE CHAIN/BELT CONNECTOR TO CARRIAGE CAUTION B) CLOSE TRAVEL LIMIT

Trigger. Battery Cap. Radar Icon. Power Button

USE AND CARE GUIDE 7000 LUMEN TWIN HEAD LED WORKLIGHT WITH TRIPOD

CHG26 IMAGINEXT. Requires four AA (LR6) alkaline batteries (not included) for operation.

PerfectTilt RF Motorized Shutter User Manual


Discovery Village. C4284 Instructions

K4074. Teaching Clock.

integra trim ltd. Holiday Home: EASTER/SPRING Try Me Hang Tag - Children s Product I Play or I Sing Goes Here Name of Song TRY ME! Product Name 2 in.

Transcription:

Battery Pack Charger OpenStage WL 3 / OpenStage WL3 Plus Installation Guide A31003-M2000-J101-2-7631

Our Quality and Environmental Management Systems are implemented according to the requirements of the ISO9001 and ISO14001 standards and are certified by an external certification company. Unify Software and Solutions GmbH & Co. KG 12/2015 Mies-van-der-Rohe-Str. 6, 80807 Munich/Germany All rights reserved. Reference No.: A31003-M2000-J101-2-7631 The information provided in this document contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. Unify, OpenScape, OpenStage and HiPath are registered trademarks of UnifySoftware and Solutions GmbH & Co. KG. All other company, brand, product and service names are trademarks or registered trademarks of their respective holders. unify.com

Inhaltsverzeichnis 3 Inhaltsverzeichnis Introduction........................................ 4 Safety...................................................................... 5 Regulatory Compliance Statements (EU/EFTA only)................................. 5 Regulatory Compliance Statements (USA/Canada only)............................... 6 Installation......................................... 6 Mounting................................................................... 7 Remove the Top Cover......................................................7 Electrical Installation.......................................................... 8 Install Single Unit........................................................... 8 Install Multiple Units......................................................... 9 Operation......................................... 12 Charging.................................................................. 12 Battery Disconnection........................................................ 12 Troubleshooting.................................... 12

Introduction 4 Introduction This document describes how to install and operate the Battery Pack Charger. Each Battery Pack Charger charges six batteries simultaneously. Figure 1 The Battery Pack Charger Supply voltage: Building fuse for fixed installation: 100-240VAC/0.7A 50/60 Hz 10 A max. Single Unit The Battery Pack Charger can be installed as a single unit. Multiple Units A number of Battery Pack Chargers and Charging Racks may be connected together. Maximum five units may be connected. An installation with multiple units requires a fixed electrical installation. NOTE: In the USA and Canada the Battery Pack Charger must only be installed as a single unit. Connection of several units is not permitted.

Introduction 5 Safety It is not allowed to supply more than one unit by the power cord with the C14 connector. The safety covers on top of the supply voltage terminal blocks must be mounted to prevent hazardous situations, like electric shock. When servicing the unit, the power cord must be disconnected. For permanently connected equipment, a readily accessible disconnect device shall be incorporated in the building installation wiring. The disconnect device shall disconnect both poles. For pluggable equipment, the wall outlet shall be installed near the equipment and shall be easily accessible. In Sweden, Norway and Finland the unit must be connected to protective earth (safety grounding). For other countries it is recommended to use a protective earth connection. Suomi: Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan. Norge: Apparatet må tillkoples jordet stikkontakt. Sverige: Apparaten skall anslutas till jordat uttag. Regulatory Compliance Statements (EU/EFTA only) This equipment is intended to be used in the whole EU & EFTA. This equipment is in compliance with the essential requirements and other relevant provisions of R&TTE Directive 1999/5/EC and the EC Council Directive 2011/65/EU on the restriction of the use of certain hazardous substances (RoHS). The Declaration of Conformity may be consulted at: http://wiki.unify.com/wiki/openstage_wl3 The product is marked with.

6 Installation Regulatory Compliance Statements (USA/ Canada only) FCC Compliance Statements for USA This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. IC Requirements for Canada CAN ICES-3 (B)/NMB-3(B) Modifications Changes or modifications to the equipment not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. Installation A fixed electrical installation must be done by an authorized electrician. Maximum five units may be connected in a fixed electrical installation. The unit shall be placed in a dry environment with a temperature range from +5 C to + 40 C (41 F to 104 F). The unit shall be mounted to a vertical wall. The unit shall be mounted to concrete or plaster walls only. Avoid mounting the unit in a sunlit place. This can affect the charging capacity. Delivery Includes Battery Pack Charger Power cord including IEC C14 connector (male) Inlet accessory kit, including cable support holders and screws A suitable extension cord is needed to connect a single unit to a wall outlet, unless the C14 connector is replaced (by an electrician). The following item can be ordered: Item EU cord UK cord SWZ cord US cord Item Number L30280-Z600-F105 L30280-Z600-F102 L30280-Z600-F103 L30280-Z600-F101

Installation 7 Required Tools etc. Screwdrivers Cutting pliers Multimeter Screws and wall plugs for wall mounting. Make sure the screws and wall plugs have the correct length for the type of wall used. Wall material Plug length Screw diameter Single plasterboard Thorsman TP1 3.5 5 mm Double plasterboard Thorsman TP2 3.5 5 mm Concrete Thorsman TP2 3.5 5 mm Mounting 1. First, make an outline of how the units are to be placed. If several Battery Pack Chargers (or Charging Racks) are to be mounted close to each other, mount them so that there is enough space between them to be able to disconnect the batteries or the handsets (vertical distance) and to be able to open the top cover (horizontal distance). When you are planning the location of the units, start to mount them in a height that makes it easy to reach the batteries. 2. Measure and mark the drill holes by using the dimensions in <Blue>Figure 2. 3. Drill and fasten the unit to the wall with four screws. Figure 2 Mounting dimensions in mm - Charging Rack seen from back 400 70.5 290 Remove the Top Cover Remove the top cover by first pressing on the sides of the top cover, then lifting it upwards.

8 Installation Figure 3 Removing the top cover Electrical Installation Install Single Unit It is not allowed to supply more than one unit by the power cord with the C14 connector. Figure 4 IEC C14 connector and extension cord with IEC C13 connector

Installation 9 Test Installation 1. Connect the power cord to the wall outlet. 2. Place a battery in the charging slot. 3. A yellow LED indicates that charging starts while a green LED indicates a fully charged battery. Install Multiple Units NOTE: Maximum five units may be connected in a fixed electrical installation. Any of the two terminal blocks can be used for AC input. The other is then used to connect the next unit. Figure 5 Units mounted and connected in a fixed installation (example) To disconnect device To disconnect device Install First Unit To install the first unit: 1. Remove the C14 connector from the power cord. 2. Measure, cut and strip the power cord. 3. Connect the power cord to the disconnect device. The IEC color code is used in the power cord supplied. Wiring color codes: IEC US Old * Load Also called Brown Black Red Active Line, Hot Blue White Black Neutral Return, Cold, Grounded connector Gr/Ye ** Green Green Earth Ground, Safety Earth, Earth Ground, Grounding conductor *** * The Old standard was used in various countries (including Australia), and some wiring may still use these colours. ** Gr/Ye - Green with Yellow stripe - this is the standard world wide, although it is not common in the US or Canada at present. *** There is an important distinction between Grounding conductor (safety earth) and Grounded conductor (Neutral). These are US terms for the conductors and they are not interchangeable, despite the similarity of the names! Install Additional Unit 1. Mount the additional unit to the wall. 2. Remove the top cover from the previous unit. 3. Remove the safety cover from the unused terminal block.

10 Installation Figure 6 Remove safety cover 4. Mount the cable support holder at the unused opening on the previous unit. The cable support holder is provided in the parts bag. Figure 7 Remove safety cover 5. Remove the C14 connector from the additional unit. 6. Cut and strip the power cord to the length required. 7. Run the power cord through the cable support holder of the previous unit. 8. Connect the power cord of the additional unit to the unused terminal block in the previous unit. Note the embossed markings L, earth symbol and N.

Installation 11 Figure 8 Terminal block for power cord 9. Secure the power cord with two screws, which are provided in the parts bag. Figure 9 Securing the power cord 10.Mount the safety cover and fasten it with one screw. 11.Replace the top cover. 12.Fasten the power cord to the wall depending on local regulations. 13.Repeat the same steps to install additional units. Test Installation 1. When the fixed installation is completed, apply AC power by switching on the disconnect device. 2. Place a battery in the charging slot. 3. A yellow LED indicates that charging starts while a green LED indicates a fully charged battery.

12 Operation Operation When the charger is connected to external power supply, normal operation is done as follows: Charging 1. Connect the charger to the AC power supply. 2. Place a battery in the charging slot to start charging. Secure the battery by moving the lock switch. Battery Disconnection 1. Unlock the lock switch on the battery. 2. Remove the battery by lifting it. Troubleshooting Fault Charging does not start Solution Check that the battery is properly inserted in the charger. Check the AC power supply connection.