Quick Start Instructions For

Similar documents
User Manual Solar Charge Controller 3KW

SC SERIES SOLAR CONTROLLER USER MANUAL Ver 1.0

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

Manual Installation & Operation

User Manual. Solar Charge Controller 3KW

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

BPS-v4 Technical Reference S-CAB 11 volt, 1 amp battery power supply

SK-10. Features. Solar Charge Controller User Manual. Important Safety Information

RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION

Duo Battery Charge Controller

PowerSTAR PS-2024-D. Maximum Power Point Tracking Solar Regulator. w w w. r o c s o l i d. c o m. a u. Contents

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

Maximum Power Point Tracking (MPPT) KA1224MPPT20A KA1224MPPT40A. Solar Charge Controller. User Manual 20A

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

ML Maximum Power Point Tracking (MPPT) Series ML2420-ML2430-ML2440 Solar Charge and Discharge Controller

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

MA-4025 Solar Charger Patent pending

TRIPS AND FAULT FINDING

Sól Dual Voltage Buck Boost Solar Charge Controller Connection & Operation V1.00

I t n e t l e l l i l g i e g n e t n So S l o a l r a Ch C a h r a g r e g Co C n o t n r t o r l o l l e l r U e s r e s Man an al

MPPT75HV MAXIMUM POWER POINT TRACKING SOLAR BATTERY CHARGE CONTROLLER

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

Advanced Hybrid Wind / Solar Charge Controller. User Manual

OD10 10A Outdoor Solar Charge Controller

Installation and Operating Instructions. Solar System Controller ISC3030

SOLAR BOOST 3024i 30AMP 12/24VDC MAXIMUM POWER POINT TRACKING PHOTOVOLTAIC CHARGE CONTROLLER

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

Reference: Photovoltaic Systems, p References: Photovoltaic Systems, Chap. 7 National Electrical Code (NEC), Articles 110,

MX60 PV MPPT Charge Controller

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

Solar Controller / Battery Charger User s Manual

MPPT SOLAR CONTROLLER FOR MODELS: 20A baterai 12V 24V

Description Sets the priority for the AC source (AC1 or AC2) for qualification and transfer.

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

Dual Voltage Solar Power Charge Controller Board Connection & Operation V2.xx

Epic PWRgate Spring City Drive Waukesha, WI

FlexCharger Battery Chargers

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

PowerOhm Installation Manual for BM R Series Braking Modules

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

Solar Hybrid Inverter SP Brilliant Series

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

INSTALLATION & OPERATION MANUAL

Intelligent Solar Charge Controller. User's Manual. Please read this manual carefully before you use this product

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

PO Box 2484 Rowville Vic 3178

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS...

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

Super Brain 977. AC/DC Charger with Dual Output and Discharge Function. User s Manual. Model Rectifier Corporation

FlinSlim Lite Solar Hybrid Inverter 1KVA-5KVA USER MANUAL. Version: 1.3

Harness the Power of the Sun

AT EVO SERIES BATTERY CHARGER

USERS MANUAL MCD REMOTE OPERATOR

User Manual 3KVA-5KVA INVERTER / CHARGER. Version: 1.1

SSL-1500 (12V/24V/48V) / SSL-3000 (12V/24V/48V)

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

OPTI-Solar SC MPPT Series

EVO AT SERIES BATTERY CHARGER

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

PowerOhm Installation Manual for LG ATV Series Braking Modules

RVS-AX Instruction Manual

CM50 Solar Charge Controller

INSTRUCTION MANUAL CAUTION

Instruction of Solar Charge Controller. User s Manual

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

LIGHTNING PROTECTION UNIT (LPU)

Installation and Operating Instructions. Solar System Controller ISC3020

SC-10 MPPT User Manual

Solar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva. With integrated star point grounding* according to VDE AR-E 2510-

MAX712 Linear-Mode Evaluation Kit

ETA mA Fully Integrated Linear Charger for 1 Cell Li-ion Battery APPLICATIONS ORDERING INFORMATION TYPICAL APPLICATION

Power Distribution System User s Manual. Model: PDS-100

PV Charge Controller SBC-7108 / 7112 / 7120

400W Solar Charger Maximum Power Point Tracker

SOLAR OFF-GRID MPPT PCU ESM3K/48, ESM5K/96, ESM7K5/120, ESM10K/120

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

Super Brain 969 Pro AC/DC Delta Peak Charger with Dual Output and Discharge Function Instruction Manual Model Rectifier Corporation

User Manual 1KW-5KW SOLAR INVERTER / CHARGER. Version: 1.2

12 VOLT 30 AMP DIGITAL SOLAR CHARGE CONTROLLER

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

PWM Charge Controller with LCD Display 30A. User Manual

Solar Hybrid Inverter SP Initial Series

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

KC5 PV Charge Controller Instruction Manual

SDC,Inc. SCR-Regenerative Ac Drive

R & D SPECIALTIES ROTROL I USER'S MANUAL

BATTERY CHARGERS FAN COOLED HIGH FREQUENCY CHARGERS UP 30% ENERGY SAVINGS! HIGH FREQUENCY BUILT-IN CHARGER AQHF24-30FC G2 TECHNICAL PECIFICATIONS

USER S MANUAL SOLAR POWER INVERTER KW-6KW

200W Solar Charger Maximum Power Point Tracker

PHOTO VOLTAIC CHARGE MODULE MULTI POINT TRACKING

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

Transcription:

Quick Start Instructions For Power Management System DESCRIPTION Stevens is much more than just a solar charge controller and regulator. It is an intelligent power management system. performs the features of a charge controller, a power monitor, SDI-12 bus activity monitor, and a remote power controller all in a single compact package. The goal of is to keep your remote data collection platform operating smoothly year after year while avoiding data outages and costly site visits. 1

CHARGE CONTROLLER Stevens features a float charger that can be used with PV arrays or power supplies having power ratings as high as 40 watts (or larger under controlled conditions). Battery temperature is sensed by a sensor installed at the terminal labeled Temp Sensor on the controller. The float level of the changes by approximately 23 millivolt per degree C, colder temperatures causing a higher float level. If the battery is located far from or in an area with differing temperature, it is recommended to place the temperature sensor on the battery and extend using standard low voltage wire. The float threshold of is adjustable via an adjustment screw located on the top of labeled Float Adjust. The 20 degree C float threshold may be set to any level between 11 and 16 volts. The charge controller will charge a fully discharged battery at the full current output of the solar panel and will automatically taper the charging current to zero as the terminal voltage of the battery approaches the float level of the charger. The charger then supplies whatever trickle current is required by the battery to maintain the battery at the float level, assuming sufficient sunlight. Any additional current, due to the load on the battery, is automatically supplied as needed, so long as there is sufficient sunlight to produce the current. An LED indicator located on the top of the unit and labeled Charge indicates when the charger is charging or holding the battery at the float level. The main purpose of this LED is to give an indication that the charger and solar panel are functional. The LED is powered from the solar panel, and will not be illuminated if there is no sunlight. A dimly lit LED will occur with low sunlight levels insufficient for battery charging. POWER MONITOR Using SDI-12 commands, can be treated like a sensor, making measurements of Solar panel voltage, Battery voltage, and Load current. Both instantaneous and averaged measurements can be made. Measurement averaging sample rate and time period are adjustable with extended SDI-12 commands (see Appendix, SOLO SDI-12 Extended Commands for details). To request measurement data using the SDI-12 protocol send am! (where a is the address, default 0). responds with a0006 to indicate 6 parameters of data are available. These 6 parameters are Instantaneous Load Current, Instantaneous Input Voltage, Instantaneous Battery Voltage, Average Load Current, Average Input Voltage and Average Battery Voltage. Current is measured in amperes, voltage is measured in volts. All measurement are fixed point with two digits to the left of the decimal and 4 to the right. Instantaneous Measurements are returned in response to the command ad0!. Average measurements are returned in response to the commands ad1!. A typical response to adn! is in the format: 2

a+cc.cccc+vv.vvvv+vv.vvvv (e.g. 0+01.2714+12.9881+11.2222) where the first parameter is Load Current, the second is Input Voltage and the third is Battery Voltage. POWER MANAGER Power cycling is often the main solution to a troubled data collection station. allows for this to happen remotely and/or automatically, eliminating costly and unnecessary trips to the remote site. Load power can be turned off and on using a set of SDI-12 extended commands. A power cycle (with programmable delays) can also be initiated with a manual button on the side of or with a pulse input at the Pulse In terminal block. Both these inputs have the delay and off-time controlled by the relevant SDI-12 commands. Additionally, can be used as an SDI-12 bus activity monitor. An extended command sets the watchdog timeout period. If does not detect SDI-12 bus activity before the timer expires, then load power will be cycled. In this way, can automatically monitor whether your logger is issuing commands to your SDI-12 sensors. If the logger ceases to issue commands, for instance due to a software crash, then will automatically restart the system. See Appendix: SDI-12 Extended Commands for all commands relating to power management. 3

WIRING Refer to the nameplate label on the top of the unit for proper wiring. Terminal connections may be made to the solar panel, battery and load in any sequence. Be careful to connect the polarity correctly. Reverse connection of the solar panel and battery will not cause damage. Reverse connection to the load, however could damage the load equipment depending on what it is. SPECIFICATIONS Maximum input voltage: Not to exceed 28 volts including transients and spikes. Maximum charging current and/or power dissipation: Typically 4 amps. The controller will conservatively handle currents to 10 amps so long as the power dissipated by the controller doesn t exceed approximately 15 watts for longer than 5 seconds ( would in this case need to be properly heatsinked). For example, assume is driven by a solar panel or power supply that is supplying 4 amps at a terminal voltage of 16 volts. Assume also that the battery terminal voltage is 13 volts. The power dissipated by the controller may be calculated as follows: P = (16 13)(4) = 12watts Higher charging currents can be handled if the input voltage is closer to the charging voltage. The maximum allowable solar panel or power supply terminal voltage for a given charging current can be calculated as follows: where: V = (15/ I) = V bat V = Maximum allowable terminal voltage of solar panel or power supply. (In no case should V be allowed to exceed 28 volts). I = Charging current V bat = terminal voltage of battery As an example, 7.5 amps of charging current can be handled by terminal voltage doesn t exceed: Solar Panel Wattage: typically 40 Watts V = (15/7.5) + V bat = 2 + V bat if the solar panel or power supply 4

Current consumption: 4-7mA, unloaded. The LED requires approximately 3 ma, however this current is supplied from the solar panel. Temperature compensation: Approximately 23 millivolt/degree C. Operating Temperature: -50 degree C to +55 degree C. Storage Temperature: -55 degree C to +85 degree C. ADJUSTING FLOAT THRESHOLD This procedure assumes that the magnitude of the desired float level has been determined for the corresponding temperature of the temperature sensor. The float voltage can be determined as follows: Vfloat = V 20 + (20 Ts)(.0234) where: V 20 = The specified float voltage for the battery at 20 degrees C. Ts = actual ambient temperature of the temperature sensor in degrees C. Step 1 Disconnect the battery from the battery leads of. Step 2 Connect a voltmeter across the battery leads of. Step 3 If the adjustment is being made in the field, be sure that the solar panel is producing adequate voltage, (several volts higher than the float level desired for the battery). If the adjustment is being made in the shop, connect a power supply to the solar input terminals, (DO NOT SET THE POWER SUPPLY OUTPUT HIGHER THAN 28 VOLTS OR YOU MAY DAMAGE ). Step 4 Adjust the screwdriver adjustment control on the top of until the voltmeter reads the desired float voltage. Step 5 Remove the voltmeter and re-connect the battery to the battery terminals. NOTES If is used as a float regulator in conjunction with a power supply, be sure that the maximum output voltage from the supply never exceeds 28 volts. If the power supply is unfiltered, then the peaks of the rectified cycles must not exceed 28 volts. Keep in mind that a dc meter generally gives a reading that represents the average of the waveform, not the peak value. An oscilloscope should be used to accurately determine the peak value of the output waveform of a non-filtered power supply. Allow a 20% or more margin for high power line voltage. 5

There is no current limiting in, so be careful not to short the BATTERY leads when is being powered by a power supply. Shorting the battery leads from will reflect the short back onto the power supply, and may damage the power supply and/or. WILL NOT be damaged by shorts on the battery leads when supplied by a solar panel. DO NOT CHANGE THE BATTERY CHEMISTRY FLOAT LEVEL (USING THE SDI-12 EXTENDED COMMAND SHOWN BELOW) WHEN UNIT IS CONNECTED TO A BATTERY. Also, changing battery chemistry will require a readjustment of the float voltage level. settings default for use with standard lead-acid type batteries. An SDI-12 extended command can be issued to to change internal settings when using Gel-Cell type batteries. Setting the proper float level for the particular type of battery will optimize the charging voltage over temperature and extend the life of the battery 6

Appendix: SDI-12 Extended Commands for : a = SDI-12 device address ### = a 3-digit number value axj0! - Switch OFF load axj1! - Switch ON load axjr! - Initiate power cycle NOTE: am9! will also initiate a power cycle. This is provided as a convenience for data loggers that do not support extended commands. axjd###! - Set off-time in seconds [001 to 255]. Must enter all 3 digits. Note: Entering axjd! restores default value (10 seconds of off-time) axjz###! - Set restart delay time in minutes [000 to 255]. Must enter all 3 digits Note: Entering axjz! restores default value (0, turn-off delay disabled). axjw###! - Set SDI-12 bus monitor watchdog timeout in minutes [000 to 255]. Must enter all 3 digits Note: Entering axjw! restores default value of (0, disable SDI-12 bus monitor). axjt###! - Set the Time between measurements in seconds used for historical averaging [001 to 120]. Must enter all 3 digits. Note: Entering axjt! restores default value of 1 second. axjm###! - Set the number of sample measurements used in historical averaging [002 to 030]. Note: Entering axjm! restores default value of 002. axjb[l or G]! - Set the battery type ["L"= lead acid "G" = Gel Cell]. Default is "L". axfr!- Display all programmable values Response is of the form: axfr:s=s,a=a,d=ddd,z=zzz,w=www,t=ttt,m=mmm,b=b where: s - 0 flash has been erased, 1 flash has been programmed a - SDI address ddd power cycle off-time (in seconds) zzz power cycle delay time (in minutes) www SDI-12 bus monitor watchdog timeout period (in minutes) ttt - time between sensor measurements (in seconds) mmm - measurement samples to be averaged b - battery chemistry, G for gel cell, L for lead acid 7